RedJET RJ330 User manual

Type
User manual
1 / 9
2 / 9
Thank you for using our company's production moving heads, for your safety and convenience, please use
the lamp before you read this manual carefully.
1. THE CONTENTS OF THE SECURITY
Installation
Before lighting installation, to ensure the stability of the installation site. When reverse hanging
installation, use two sets of M10 bolt professional large hooks screwed into the bottom of the computer
lights hanging screw holes, you must make sure not to drop the lamp down on the support frame, with a
safety rope through the support bracket and lamps handle, to prevent the lamp falling and sliding. Lamps
during installation, prohibit pedestrians below. Regularly check the safety rope for wear, whether linked
to loosen. Rigging thus instability occurs, leading all the consequences arising from the lamp falling,
manufacturers do not bear any responsibility.
Minimum distance to the target object:
When the lamp during positioning, the distance between the object and the lighting lens beam irradiation
at least to keep 1.5m away.
The minimum distance from combustible body
When the lamp during the installation location, the minimum distance from any point to any combustible
material is two meters on a light surface.
Maximum ambient temperature
Highest ensure stable operation of the lamp ambient temperature does not exceed 40 , the minimum
should not exceed -20 .
Important Notice
This instruction manual contains important information regarding the installation and use of
products of this fixture. Please strictly follow these instructions related to installation and use.
Before opening this fixture products or want to repair, replace light bulbs, etc., make sure the
power is off.
A: Please read the entire contents of this manual carefully. (This specification please save with
light.)
B: To ensure that this product is correct, safe installation, use and maintenance, must understand
and comply with the contents of this manual operation.
C: for failing to carry out the installation, use and maintenance in accordance with the
requirements of this specification, which led lamps, property or personal injury, the manufacturer
does not assume any responsibility.
Note: Based on our ongoing product improvement, the data contained in this manual likely will
change in the future, but will be without notice to change matters. The Company reserves the
change in the product specification improvements related powers.
3 / 9
Static protection and against electric shock
The lighting design in accordance with the type of protection against electric shock. To connect with
ground lighting power system. And ground lighting must be turned on and the ground power system,
lighting metal ground mark the port to securely connected to the mounting lighthouse.
Connect the power mains
Connected to the power mains must be performed by a qualified electrical professional to complete.
Check Fixtures power supply line voltage, frequency and other electrical data, whether marked with lamp
voltage, frequency parameters consistent, avoid high-voltage lamps burning ring. Please refer to the lamp
power fixtures use multiplied by 1.5 times, you can figure out all the lights when connected, the maximum
power supply parameter values.
Care and Maintenance
Before carrying out maintenance disassembly lighting products, to disconnect the power supply, can not
live action, after disconnecting the power supply, any part of the lamp within 10 minutes is not removable.
If you need to replace the lamp, you need to wait 15 minutes for the lamp to be operated completely
cooled.
Any lamp bulbs have life, this lamp is recommended to use foam cups 330W bulbs, light bulbs average
life of 750 hours. Computer light bulb usage time do not exceed its rated life, otherwise it may cause the
bulb bursts, the shock wave generated when the lamp exploded inside the lamp will damage the
condenser system, there are likely to generate high voltage breakdown of electronic components. Hot
lamp debris may also burn people, objects, and may even lead to a fire.
Lamp lenses or lenses and other rotating parts must be checked regularly to keep it stable, if there is
obvious damage or loose, it must be replaced promptly reinforced, to prevent accidents.
Lighting products using strong winds refrigeration, easy to dust must be cleaned at least once a week,
especially the cooling air inlet.
Luminaire housing temperature
In the heat stable working conditions, the maximum surface temperature of the lamp housing can reach
70 .
Lamps
15R lamps built with a foam cup, high internal temperature, do not directly touch. If you install a new
lamp, please read the manufacturer's instructions carefully. If the lamp is damaged or thermally deformed,
should be replaced immediately.
Unpacking
Open the box, remove all accessories from the box and open the packaging, remove the fixture from the
box and place it on a level platform to facilitate related operations.
4 / 9
Package Contents
In addition to lighting, the package is also equipped with the following items:
Accessory Optional
1: cable a.lamps
2: signal line b.rack
3: Instructions:
4: Warranty Card:
2.LAMP INSTALLATION
Loosen the beam lamp head plastic cover, open the inlet side of the fan, you can replace the lamp. When
installing the bulb, the bulb should be noted seated, otherwise easily lead to poor contact due to a short
circuit high voltage discharge, the impact of lamp life, damage to the circuit board components.
5R Cup bubble series products as high-pressure lamp bulb with external trigger, so when these lamps
operate, need to be careful. Before the operation, you should read the notes on these lamp manufacturers
to provide, by the operation of accidents caused by improper manufacturer does not assume any
responsibility.
Warning 1: lamp bulb is not installed, do not turn on the power to the computer lights, otherwise it will
burn fixtures.
Warning 2: bulb during installation, you must first disconnect the power.
Warning 3: The physical characteristics of the lamp work will reach a very high temperature, and gas
discharge bulbs can not continue to supply it, it must after every power failure, after 15 minutes to cool
completely before it can be anything. Doing so can cause high voltage discharge, short circuit, and even
burn computer control components on the board.
3.POWER SUPPLY AND SIGNAL CABLE
Main power connector
Using a dedicated plug to connecte computer lamp and power supply. It should be noted fixtures voltage
with frequency and power supply are the same signs on. Recommended that each lamp has a separate
power switch, so you can freely make each computer lights turned on or off . This fixture selection of input
voltage and frequency parameters are:
Voltage
90v/240v
Frequency
50-60Hz
Signal cable
Connecting the output of the host fixture and the terminal of the fixture between,put The host computer
DIGITAL OUT socket is connected to the vice computer IN socket. Then OUT jack is connected to the next
fixtures IN socket, and so on until all the sub scanners are connected together. As shown below:
5 / 9
If you need to extend the communication cable connection, the male and female 3-pin XLR plugs at both
ends of a corresponding 1,2 corresponding 2,3 corresponding 3, otherwise easily lead to a communication
break. (Note: Each cables with a core diameter should be at least 0.5mm, best to use dual-core shielded
cable).
When the computer lights signal line access or take out, you should use a cylindrical 3-pin XLR plugs and
fixtures be provided. Note that all 3-pin XLR internal wires should not touch each other or come into
contact with the plug body.
The fixtures can accept DMX512 digital control signal format, the control signal socket connected to
labeled "IN" panel, and then mark it from there "OUT" socket connected to the next fixtures "IN" socket .
When installation is recommended to use DMX signal terminator. It is possible to avoid the damage
caused by electrical noise digital control signal. In simple terms, DMX terminator is a XLR connector,
between its 2 pin and 3 pin have a 1W and 120
ohm resistor, connect it to the computer lights chain last computer lights OUT socket.
The lamp is turned on methods
After completing all of the above operations and ensure that the corresponding model bulbs installed,
press the power switch to check whether everything is normal. After the switch is turned on before the
computer is lit lamp. The fixtures start after a few seconds mechanically reset setting operation, since after
the inspection, the LCD shows the DMX signal the start-coded values.
Menu Structure
Front cover-- Set up ---Run mode
DMX location
Channel Mode
X Reversion
Y Reversion
Y Reversion
XY Encoder
Not DMX Signal
Screen Saver
Boot then lamp comes on
Color wheel linear change
Manual Restore Default Settings
Options
Explanation
Run mode
DMX
From the machine Status receive DMX signals from a control
station or host
Self-propelled1
host hospital switch StatusSelf-propelled and sends a DMX
signal to the slave
Self-propelled2
Self-propelled3
Self-propelled4
Painting 8
Painting ago 0
6 / 9
Manual control
This interface is used to control the current lighting and automatically enter the host state (does not
receive DMX signals emitted DMX signal to the slave from the mainline).
Manual menu will be Standard 16CH and Expand 20CH, the corresponding display 16 channels or 20
channels.
Before painting the
vertical 8
To sleep before
painting 8
Random self-
propelled
Sound Control
DMX
Address
1~512
Press the "OK" button to enter the edit mode. At this point is
to select one hundred, press "up" "down" key to change the
address code. Press the "OK" button to select ten editing. Press
the "OK" button to select the bit editing. Press again to exit
edit mode
Channel
Mode
Standard 16CH
Standard 16 Channel Mode17~20CH Invalid channel
Expand 20CH
Expand 20CH mode17~20CHChannel Control Speed See
channel table
X Reversion
off
on
Y Reversion
off
on
XY Exchange
off
on
XY axis exchange channels (including trim)
XY Encoder
on
Use encoder ( optocoupler ) judge out of step and
automatically correct position
off
Do not use the encoder (optocoupler) to correct position
Not DMX
Signal
Maintain
Original state continues to run
Cleared
Motor back position, stop running
Screen Saver
on
The idle 30 seconds after turning off the backlight
off
Backlight always on
Boot light
bulb
off
Directly after power-on reset, not bright bulbs (need to use the
menu or the console to manually bulbs on)
on
Automatically after power-on bulbs on and to wait until the
lamp is lit successfully reset
Color wheel
linear
change
on
Color wheel linear change
off
Nonlinear changes color wheel, half color change
Restore
Default
Settings
Press the "OK" button to see a confirmation dialog box, press
the "OK" key to restore the default settings
7 / 9
Explanation
0~25
5
Press the "OK" button to enter the edit mode. At this point is
to select one hundred, press "up", "down" key to change the
channel value. Press the "OK" button to select ten editing.
Press the "OK" button to select the bit editing. Press again to
exit edit mode
0~25
5
0~25
5
Press "OK button" after seeing the confirmation dialog box,
click "OK" button, enter the reset interface, all motor reset
again
on
200-205
off
100-105
4. TECHNICAL PARAMETERS
Voltage: AC90V-240V 50Hz -60 Hz
Power: 400W
Lamps: 16R 330W
Color Temperature: 6000°K
Service life: 500h
Color: one color wheel14 color+white,Variable continuously rotating color wheel can produce
a rainbow effect in any direction. a rotating 16 prism(can customized 8 or 24 prism), can reverse
positive and negative direction and with prism positioning function . With two pieces
magnifying glasses. And one piece atomization glass.
Zoom, with a rotating touch display screen. Optics, combination lens and the zoom 0-3.9 degrees,
electronic zooming at 20 meters
Strobe: Fast action strobe can be quickly interrupted beams light and can achieve 1-10 times per
second strobe effect. Fast action can be quickly interrupted beams shoot strobe, and can achieve
1-10 times per second strobe effect. It also has the effect of dimming.
The zoom: Electronic linear zoom system.
The motor: By built-in microprocessor-controlled precision stepper motor components.
Control: Microprocessor: high stability and strong anti-interference ability CPU
o Digital Control: DMX512
Light body: By a combination of engineering plastic shell molding, streamline design, elegant
appearance.
Fan: Using DC12-24V fan, air-cooled natural speed. Cooling fan and overheat protection
Adjustable strobe rate
540 ° horizontal rotation 270 ° Vertical Tilt Unobstructed
Standard DMX512 control signal
18CH and LCD display
Work Environment: Indoor -20 to 50.
Shell: Temperature and high-strength plastic shell using metal powder coating technology,
streamlined design.
Lamp Size: 410mm*360mm*570mm
Packing size: 490mm*470mm*580mm
N.W.:21KG
N.W: 24KG
8 / 9
5. 330W MOVING HEAD BEAM LIGHTS WORKING CHANNEL
Channel
Channel mode
1
Color Wheel
0-255
2
Switching / Strobe
0-255
3
Dimming
0-255
4
Pattern plate
0-255
5
Pattern of rotation
0-255
6
Prism
0-255
7
Prism of rotation
0-255
8
Focusing
0-255
9
Enlarge 1
0-255
10
Enlarge 2
0-255
11
Atomization
0-255
12
X
0-255
13
X Fine tuning
0-255
14
Y
0-255
15
Y Fine tuning
0-255
16
X Y Speed
0-255
17
RESET
0-255
18
Lamp control
100-105 light off 200-205 light on
6. The cleaning and maintenance
To ensure stable operation fixtures should keep it clean. Cleaning is recommended every 15 days once
the body and fan. For lenses and color separation filter should be cleaned regularly to ensure the best
light period. Be careful not to use any soluble detergent when cleaning the optical separating filter, so as
not to cause damage to the lamp.
9 / 9
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

RedJET RJ330 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI