Summers Heat 25-CBPAH Owner's manual

  • Hello! I've reviewed the Installation & Operation Manual for the England's Stove Works pellet stoves, including models 25-CBPAH, 55-SHPCBPAH, and 55-TRPCBPAH. This manual provides important details on installation, safety, and maintenance, including using outside air and proper fuel. I'm ready to answer your questions about these pellet stoves and their operation.
  • What type of fuel should I use?
    Is outside air mandatory for this unit?
    What should I do before my first fire?
    How do I start the stove?

CAUTION
PLEASEREADTHISENTIREMANUALBEFOREINSTALLATIONANDUSEOFTHISPELLETFUELBURNING
APPLIANCE.KEEPCHILDREN,FURNITURE,ANDALLCOMBUSTIBLESAWAYFROMANYHEATINGAPPLIANCE.
SAFETYNOTICE
FAILURETOFOLLOWTHESEINSTRUCTIONSCANRESULTINPROPERTYDAMAGE,BODILYINJURYOREVEN
DEATH.FORYOURSAFETYANDPROTECTION,FOLLOWTHEINSTALLATIONINSTRUCTIONSOUTLINEDIN
THISMANUAL.CONTACTYOURLOCALBUILDINGORFIREOFFICIALSABOUTRESTRICTIONSAND
INSTALLATIONINSPECTIONREQUIREMENTS(INCLUDINGPERMITS)INYOURAREA.
ManufacturedBy:
England’sStoveWorks,Inc.
POBox206
Monroe,VA24574
Rev.1/2022
SAVETHESEINSTRUCTIONS
INSTALLATION&OPERATION
MANUAL
25CBPAH
55SHPCBPAH
55TRPCBPAH
THISWOODHEATERNEEDSPERIODICINSPECTIONANDREPAIRFORPROPEROPERATION.CONSULTTHE
OWNER’SMANUALFORFURTHERINFORMATION.ITISAGAINSTFEDERALREGULATIONSTOOPERATETHIS
WOODHEATERINAMANNERINCONSISTENTWITHTHEOPERATINGINSTRUCTIONSINTHEOWNER’S
MANUAL.
Laversionfrançaisedecemanuelsuitlaversionanglaise.
www.heatredefined.com
Parts:(800)5163636
Support:(800)2456489
2
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
IMPORTANT:IFYOUHAVEAPROBLEMWITHTHISUNIT,DONOTRETURNITTO
THEDEALER.CONTACTTECHNICALSUPPORT@18002456489
TamperWarning:
Thiswoodheaterhasamanufacturersetminimumlowburnratethatmustnotbe
altered.Itisagainstfederalregulationstoalterthissettingorotherwiseoperate
thiswoodheaterinamannerinconsistentwithoperatinginstructionsinthis
manual.
MobileHomeUse:
Thisfreestandingpelletunitisapprovedformobilehomeordoublewide
installationwiththeoutsidecombustionairhookupSeethe“Installation”section
ofthismanualfordetailspertainingtomobilehomeinstallations.Mobilehome
installationmustbeinaccordancewiththeManufacturedHomeandSafety
Standard(HUD),CFR3280,Part24.
WARNING:
USEOFOUTSIDECOMBUSTIONAIRISMANDATORYWITHTHISUNIT.
DONOTOPERATEWITHTHEHOPPEROPEN;LIDMUSTBESHUTANDTIGHTLY
LATCHEDDURINGOPERATION.DONOTOVERFIREYOURUNIT.
Note:England’sStoveWorksdoesnotrecommendusingapelletstoveasyour
onlysourceofheat.
Retainforyourfiles
ModelNumber
DateofPurchase
DateofManufacture
SerialNumber

3
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
Welcome!
Introduction
ThankYou.........................................5
Specifications
HeatingSpecifications.......................6
Dimensions........................................6
EPACompliance.................................6
Installation
InstallationOverview...................7
ClearancestoCombustibles.........8
VentingIntroduction...................9
VentingGuidelines.......................9
AdditionalVentingInformation...10
ApprovedVentingMethods
ThroughtheWall...........11
ThroughtheCeiling........12
ExistingChimney............13
MobileHomeInstallation............14
VentTerminationClearances......15
OutsideAirHookup.....................16
FloorProtection...........................17
DailyOperation
GettingStarted............................18
LightingaFire..............................18
DailyOperationNotes………………19
ControlBoard
ControlBoardSettings................20
ErrorCodes..................................21
PowerFailure……..……………………22
Maintenance
Daily
ImportantNotes..............23
DailyAshRemoval...........23
CleaningtheBurnPot......24
Weekly
BaffleRemoval...........25
CleanOutCovers.............25
Monthly
ImportantNotes…………….26
VentingPipeCleaning…….27
Yearly
ImportantNotes..............28
ExhaustBlower................29
ConvectionBlower...........29
HopperFines....................30
CheckingGaskets.............30
BasicTroubleshooting.......................31
ReplacingComponents
AugerMotor.......................................33
ConvectionBlower.............................34
CombustionBlower............................35
VacuumSwitch...................................36
Igniter.................................................37
Gaskets...............................................38
Glass...................................................39
ControlBoard.....................................40
WiringDiagram..................................41
HopperLidHinges..............................42
HopperLidHandle..............................42
Panels………………………………………………43
Finish……………………………………………….43
IllustratedPartsDetail
ExplodedPartsDiagram……………………44
PartsList……………………………………..…..45
Warranty
SerialTagSample…………………….………..47
WarrantyDetails……………………………....48
ImportantNotice………….…….....…………50
WarrantyReg.Form………………………….51
AIR WASH BAR PLACEMENT
CAUTION:TheAirWashBarmaybecomejarredlooseduringshipping.
BESUREthattheAirWashBarisinstalledproperlybeforeeachfire,
includingaftercleaningandmaintenance.
TheAirWashBarshouldfitintothetwoinstallationholesand‘lean
forward’onthefrontwallofthestove.
Thebendinthebarshouldbendtowardthefrontdooropening,andnot
backwardtowardtheburnpot.

InstallationHoles
AirWashChannels
FireBox
InstalltheAirWashBartabsintotheholes
andnotintotheairwashchannels
Thebendoftheairwashbar
shouldfaceTOWARDthefront
door
FrontDoorO
p
enin
g
AirWashBar
(installed)
AirWashBar
5
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
INTRODUCTION
ThankyouforpurchasingthisfineproductfromEngland’sStoveWorks!
England’sStoveWorkswasstarted,andisstillownedby,afamilythatbelieves
stronglyina“DoItYourself”spirit;that’sonereasonyoufoundthisproductat
yourfavorite“DoItYourself”store.
Weintentionallydesignandbuildourstovessothatanyhomeownercanmaintain
theirstovewithbasictools,andwe’realwaysmorethanhappytohelpyoudothe
jobaseasilyandasinexpensivelyaspossible.However,whileremainingsimple,
ourstovesaredesignedtoperformextremelyefficiently,helpingdelivermore
heatfromlessfuel.
PleaselookattheextensiveHelpsectiononourwebsiteandcallourTechnical
SupportDepartmentat(800)2456489ifyouneedanyhelpwithyourstove.We
arenearlyalwaysableto“walkyouthrough”anyinstallationissues,repairs,
problemsorotherquestionsthatyoumayhave.
Wishingyouyearsofefficient,qualityand“comfy”heating,
EveryoneatEngland’sStoveWorks
PleaseNote:Whileinformationobtainedfromourwebsiteandthroughour
TechnicalSupportlineisalwaysfreeofcharge,therewillbeaservicecharge
incurredwithany“onsite”repairsormaintenancethatwemayarrange.
Thismanualencompassesallversionsofthe25CBPAH,includingthe55SHPCBPAHandthe55TRPCBPAH.
However,forsimplicityofdescription,thestovewillbereferredtobythegeneric25CBPAHdesignation.

This manual is available for free download on the manufacturer’s web site. It is a copyrighted document and resale
is strictly prohibited. The manufacturer may update this manual occasionally and cannot be responsible for
problems including injuries or damages resulting from the use of information found in any manual from
unauthorized sources.
CAUTION:Stoveisheavy.
Inaddition,whenhandlinganysheetmetalproducts,beawarethattheremaybesharpedgesorburrs.
Althoughwemakeeveryefforttoeliminateanysharpedges,pleaseusecautionwhenhandlinganymetalparts.
Remembertodisconnect(unplug)thestovefromthepowersourceandallowittocompletelycooldown
beforeperforminganymaintenance.
6
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
SPECIFICATIONS
HeatingSpecifications
ApproximatePelletBurnRate**………….………………0.9to2kg/hr(2to4.4lbs/hr)
MaximumBurnTime**………………………………………………………………………..76hours
HeatOutput**…………………………………………………………11,09825,122BTU/hr.
ApproximateSquareFootageHeated***…….………………………….upto2,200sq.ft.
HopperCapacity………………………………………………………………………….…..120pounds
Dimensions

EPAandSafetyComplianceSpecifications
EPAComplianceStatus…….........................................Certifiedtocomplywith2020particulate
emissionstandardsusingpelletfuel.
U.S.TestStandard……………………………………………………..EPA40CFRPart602015
ParticulateEmissions…………………………………………………………………1.47grams/hr.
COEmissions………………………………………………………………………….0.000grams/min.
Efficiency………………………………………………………….……………………………67.6%(HHV)
CertifiedTo…….…………………………...UL148211,ASTME150912,&ULCS62700
Notesforthisunit:Productmayvaryslightlyfromdiagram.Clearancesaretheminimumforthisunit
andmayneedtobeincreasedinthereartohaveproperventclearances.Followallventingmanufacturer
clearancesandlocalcodes.
*‐AstestedperASTM277910
**‐Heatoutput,burnrateandmaximumburntimeareheavilydependentonthetypeofpelletsburnedinthestove;assuch,thesenumbersmayvary.
***‐Themaximumheatingcapacityofthisunitcanvarygreatlybasedonclimate,constructionstyle,insulationandamyriadofotherfactors.Usethisinformation
inconjunctionwithaBTUlosscalculationforyourhometodetermineifthisunitwillbesufficientforyourneeds.
7
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
INSTALLATION
InstallationOverview
Whenchoosingalocationforyournewstove,thereareamultitudeoffactorsthat
shouldbetakenintoaccountbeforebeginningtheinstallation.
1. TrafficPatternsTohelppreventaccidents,thestoveshouldbeplacedinalocation
whereitisoutofthewayofnormaltravelthroughthehome.
2. HeatFlowandEfficiencyWhendecidingonalocationforthestove,considertheway
heatmovesthroughoutyourhome.Installthestovewhereyouneedtheheat;
basementinstallationsoftendonotallowsufficientheattoflowtotheupperfloorsand
atopfloorinstallationwillnotallowanyheattoreachthefloorsbelow.Always
considerthatheatrisesandwilltakethepathofleastresistancewhileitisstillhot.
3. ExhaustLocationOutsidewallsaregenerallythebestplacetoinstallastove,since
theyalloweasyexhaustandintakeairinstallation(usingourDuraVentAC3000Kit,AC
33000ifCanada).Ifthereisnotafeasiblewaytoinstallthestoveonanoutsidewall,
therearemethodsforventingthestoveupthroughtheroof,buttheytendtobemore
costlybecausetheyinvolvetheuseofmorepelletventpipeandcanoftenmakeoutside
airinstallationmoredifficult.
4. WallConstructionLocatingthestovesothattheexhaustsystemcanpassbetween
studswillsimplifytheinstallationandeliminatetheneedtoreframeanysectionsofthe
walltoaccommodatethewallthimble.
Warning
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
Do Not Over fire – If any external part starts to glow, you are over firing. Reduce feed rate.
Over firing will void your warranty.
Comply with all minimum clearances to combustibles as specified. Failure to comply may
result in a house fire.
Tested and approved for wood pellets only. Burning any other fuel will void your warranty.
For use with Premium grade wood pellets only.
8
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
INSTALLATION
ClearancestoCombustibles

CAUTION
UnitcanbeveryHOTwhileinoperation.Keepchildrenaway.
Supervisechildreninthesameroomasthisappliance.
Alertchildrenandadultstothehazardsofhightemperatures.
DoNOToperatewithprotectivebarriersopenorremoved.
Keepclothing,furniture,draperiesandothercombustiblesaway.
InstallationMUSTcomplywithlocal,regional,stateandnationalcodesandregulations.
Consultlocalbuilding,fireofficialsorauthoritieshavingjurisdictionaboutrestrictions,installationinspection,and
permits.
DONOTCONNECTTOANYAIRDISTRIBUTIONDUCTORSYSTEM
UnittoRear
Wall(A)
UnittoSide
Wall(B)
UnittoCorner
(C)
0in.8in.6in.
0mm203mm152mm
9
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
INSTALLATION
VentingIntroduction
Thispelletstoveoperatesonanegativedraftsystem,whichpullscombustionairthroughthe
burnpotandpushestheexhaustairthroughtheventpipeandoutofthebuilding.Thisunitmustbe
installedinaccordancewiththefollowingdetaileddescriptionsofventingtechniques;notinstalling
thestoveinaccordancewiththedetailslistedherecanresultinpoorstoveperformance,property
damage,bodilyinjuryordeath.England’sStoveWorksisnotresponsibleforanydamageincurred
duetoapoororunsafeinstallation.
Ifquestionsarisepertainingtothesafeinstallationofthestove,ourTechnicalSupportline
(8002456489)isavailable.Contactyourlocalcodeofficialtobecertainyourinstallationmeetslocal
andnationalfirecodesandifyou’reuncertainabouthowtosafelyinstallthestove,westrongly
recommendcontactingalocalNFIcertifiedinstallertoperformtheinstallation.
VentingGuidelines
WARNING‐INSTALLVENTATCLEARANCESSPECIFIEDBYTHEVENTMANUFACTURER.
ALWAYSinstallventpipeinstrictadherencewiththeinstructionsandclearancesincludedwith
yourventingsystem.
DONOTCONNECTTHISPELLETSTOVETOACHIMNEYFLUEWHICHALSOSERVESANOTHER
APPLIANCE.
DONOTinstallafluepipedamperoranyotherrestrictivedeviceintheexhaustventingsystem
ofthisunit.
USEanapprovedwallthimblewhenpassingthroughawallandaceilingsupport/firestop
whenpassingthroughaceiling.
ONLYuse3.0”or4.0”TypeLorTypePLpipeapprovedforpelletstoveventing;DONOTuse
galvanizedorBVentpipe.
SEALeachjointofpelletventwithhightemperaturesilicone(Part#ACRTV3)toprevent
smokespillageintothehome.
AVOIDexcessivehorizontalrunsandelbows,asbothwillreducethedraftoftheventing
systemandwillresultinpoorstoveperformance.
INCLUDEasmuchverticalpipeaspossibletopreventsmokefromtheunitfromenteringyour
homeintheeventofapoweroutage.
INSPECTyourventingsystemoften,tobecertainitisclearofflyashandotherrestrictions.
CLEANtheventingsystemasdetailedinthemaintenancesectionofthismanual.
WARNING
INSTALLVENTATCLEARANCESSPECIFIEDBYTHEVENTMANUFACTURER.
HOT!Donottouch!Severeburnsorclothingignitionmayresult.
Glassandothersurfacesarehotduringoperation.
Donotattempttotouchoropenthefrontorsidepanelsduringoperation.Thiscouldresultinsevere
burnsorinjury.
10
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
INSTALLATION
AdditionalVentingInformation
Donotmixandmatchcomponentsfromdifferentpipemanufacturerswhenassemblingyour
ventingsystem(i.e.DoNOTuseventingpipefromonemanufacturerandathimblefrom
another).
Werequireaminimumverticalriseof36in.(3ft.)ofpipetocreatenaturaldraftinthesystem.
Thishelpsevacuatesmokefromthestoveintheeventofapowerfailureorcombustion
blowerfailure.
Ventingsystems15.0ft.orshortermaybecomposedentirelyof3.0in.pelletpipe;toreduce
frictionallosses,ventingsystemslongerthan15.0ft.shouldbecomposedof4.0in.pelletpipe.
Donotterminatetheventingsystemdirectlybeneathanycombustiblestructuresuchasa
porchordeck.
FollowNFPA211ruleslistedbelowforventingsystemterminationlocationrelativeto
windowsandotheropeningsinthedwelling.
o NFPA211(2006ed.)Section10.4Termination:10.4.5
(1)Theexitterminalofamechanicaldraftsystemotherthandirectventappliances
(sealedcombustionsystemappliances)shallbelocatedinaccordancewiththe
following:
(a)Notlessthan3ft.(.91m)aboveanyforcedairinletlocatedwithin10ft.
(3.0m).
(b)Notlessthan4ft.(1.2m)below,4ft.(1.2m)horizontallyfromor1ft.(305
mm)aboveanydoor,windoworgravityairinletintoanybuilding.
(c)Notlessthan2ft.(0.61m)fromanadjacentbuildingandnotlessthan7ft.
(2.1m)abovegradewhenlocatedadjacenttopublicwalkways.
Distancebetweentheterminationopeningandgradeshouldbeaminimumof2ft.(24in.)
contingentonthegradesurfacebelowthetermination.Whendeterminingthetermination
heightabovegrade,considersnowdriftlinesandcombustiblessuchasgrassorleaf
accumulation.Inareaswheresignificantsnowfallispossible,theterminationheightmustbe
sufficientlyhightokeeptheterminationfreeofsnowaccumulation.
Donotusemakeshiftcompromisesduringinstallationorinstallanycomponentoftheunitor
ventingsysteminsuchamannerthatcouldresultinahazardousinstallation.
Achimneyconnectorshallnotpassthroughanatticorroofspace,closetorsimilarconcealed
space,orafloor,orceiling.
Wherepassagethroughawallorpartitionofcombustiblematerialisdesired,theinstallation
shallconformtoCAN/CSAB365.
WARNING:
VentingsystemsurfacesgetHOT,andcancauseburnsiftouched.
Noncombustibleshieldingorguardsmayberequired.
11
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
INSTALLATION
ApprovedVentingMethod1:ThroughtheWall
Generallythesimplestinstallationmethod,venting
throughthewallusingourAC3000kit,AC33000ifCanada
(orsimilarventingsystem)isalsothepreferredventing
method.Itminimizeshorizontalpipe,allowsthestoveto
beinstalledclosetothewallandkeepsthecleanouttee
ontheoutsideofthehouse,foreaseofcleaning.
Wheninstallinganyventingsystem,TypeLorTypePL
pipemustbeusedandallclearancestocombustibles
(listedbythepipemanufacturer)mustbestrictlyadhered
to.
Usethepipemanufacturer’sapprovedthimblefor
passingthroughacombustiblewall,andmaintainatleast
theminimumclearancestocombustibles.
Useanappliancecollarwherethepelletventconnects
totheexhaustoutputofthepelletstoveandattachthe
appliancecollartotheexhaustbloweroutputusingthree
sheetmetalscrews.
Securethepelletventtotheoutsideofthehouseusingawallstrapjustbelowthe90degree
elbow.
SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemisleak
free(Checkwiththespecificventingsystemmanufacturer’sinstructionsbeforedoingso).
Ifthepelletventpipebeingusedisnota“TwistLock”system,three(3)sheetmetalscrewsare
requiredateachpipejoint.
Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyourstoveorusing
analternativemethod,asdescribedinthe“OutsideAir”section,onpage16.
Thisinstallationtypecanbemodifiedforbasement(Basementinstallationsshouldalwaysbe
performedbyaprofessionalinstaller)orotherinstallationswhereintheteeandverticalsectionof
thepipewouldbeinsidethehomeandtheventingsystemwouldsimplypasshorizontallythrough
thethimbleandthenterminate.
PleaseNote:
Installationdiagramsareforreferencepurposesonlyandarenotdrawntoscale,normeanttobeusedasplansforeach
individualinstallation.Pleasefollowallventingsystemrequirements,maintaintherequiredclearancestocombustibles,
andfollowalllocalcodes.
Forhighaltitudeinstallations
(above4,000ft.),theventpipe
shouldbeincreasedfrom3inch
(3”)tofourinch(4”).
12
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
INSTALLATION
ApprovedVentingMethod2:ThroughtheCeiling
Ventingthroughtheceiling/roofmaybetheonlyfeasible
ventingoptioninsomecasesandisafactoryrecommended
installation.
Wheninstallinganyventingsystem,TypeLorTypePLpipe
mustbeusedandallclearancestocombustibleslistedbythe
pipemanufacturermustbestrictlyadheredto.
Usethepipemanufacturer’sapprovedceilingsupportfor
passingthroughacombustibleceiling,aswellastherequired
firestops,radiationshields,flashingandstormcollar.
Becertaintofollowthemanufacturer’srequiredheightof
terminationabovetheroofline,andmaintainatleastthe
minimumclearancestocombustibles.
Useanappliancecollarwherethepelletventconnectstothe
exhaustoutputofthepelletstoveandattachtheappliance
collartotheexhaustbloweroutputusingthreesheetmetal
screws.
SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemisleak
free(Checkwiththespecificpipemanufacturer’sinstructionsbeforedoingso).
Ifthepelletventpipebeingusedisnota“TwistLock”system,three(3)sheetmetalscrewsare
requiredateachpipejoint.
Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyourstoveorusing
analternativemethod,asdescribedinthe“OutsideAir”section,onpage16.
Thisventingmethodcanalsobemodifiedsothattheventingsystemrunshorizontallythroughthe
wallfromthestove,thentransitionstoverticalandterminatesabovetheroofline.Whenusing
thismodifiedversionofthisinstallationbecertaintocarefullyfollowtheventingsystem
manufacturer’sinstructionsdiligently.
PleaseNote:
Installationdiagramsareforreferencepurposesonlyandarenotdrawntoscale,normeanttobeusedasplansforeach
individualinstallation.Pleasefollowallventingsystemrequirements,maintaintherequiredclearancestocombustibles,and
followalllocalcodes.

Forhighaltitudeinstallations
(above4,000ft.),theventpipe
shouldbeincreasedfrom3inch
(3”)tofourinch(4”).
13
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
INSTALLATION
ApprovedVentingMethod3:ExistingChimneySystem
Usinganexistingmasonryorfactorybuiltchimneyforventingistheonlyotheracceptablemethod
forventingthispelletunit.
UseTypeLorTypePLventingpipeuntilenteringthe
existingchimney.Usetheappropriatelysizedadapterwhen
transitioningfromthepelletventpipetothemasonryor
factorybuiltthimbleandbecertainthattheadapteris
sealedtightlytoboththepelletventingsystemandthe
existingchimney.
Beforeusinganexistingchimney,becertainitisingood
condition(Achimneysweepinspectionishighly
recommended).Also,makesurethechimneymeetsthe
minimumstandardslistedinNFPA211(Achimney
professionalcanconfirmthisuponinspection).
Ifconnectingthisstovetoafactorybuiltchimney,itmay
ONLYbea6”flue,UL103HTventingsystem(ULCS629if
Canada).Connectiontoanyotherfactorybuiltchimneymay
resultinapoorlyoperatingordangerousstoveinstallation.
Whenconnectingtoanexistingmasonrychimney,thecrosssectionalareaofthefluemustbe
considered.Achimneywithafluelargerthan6”round(28.27sq.in.)mayrequirereliningwithan
approvedpelletstovechimneyliningsystem.
Useanappliancecollarwherethepelletventconnectstotheexhaustoutputofthepelletstove
andattachtheappliancecollartotheexhaustbloweroutputusingthreesheetmetalscrews.
SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemisleak
free(Checkwiththespecificpipemanufacturer’sinstructionsbeforedoingso).
Ifthepelletventpipebeingusedisnota“TwistLock”system,three(3)sheetmetalscrewsare
requiredateachpipejoint.
Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyourstoveorusing
analternativemethod,asdescribedinthe“OutsideAir”section,onpage16.
PleaseNote:
Installationdiagramsareforreferencepurposesonlyandarenotdrawntoscale,normeanttobeusedasplansforeachindividual
installation.Pleasefollowallventingsystemrequirements,maintaintherequiredclearancestocombustibles,andfollowalllocal
codes.
Forhighaltitudeinstallations
(above4,000ft.),theventpipe
shouldbeincreasedfrom3inch
(3”)tofourinch(4”).
14
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
INSTALLATION
MobileHomeInstallation
TheEngland’sStoveWorks,Inc.outsideairkitMUSTbeusedforinstallationofthisunitina
mobilehome.Pleaseseethe“OutsideAir”sectiononpage16formoreinformationregarding
outsideairconnections.
Theoutsideairinletmustbekeptclearofleaves,iceandotherdebris.Keepingtheoutsideair
inletfreeofrestrictioniscrucialtopreventingairstarvationandsmokespillage.
ThepelletstoveMUSTbesecuredtothefloorofthemobilehomeusinglagboltsandtheholes
providedinthebottomofthebaseforthispurpose.Outdoorairedspaceheatersmustbe
attachedtothestructure.
ThepelletstoveMUSTbegroundedwith#8solidcoppergroundingwire(orequivalent),
terminatedateachendwithanNECapprovedgroundeddevice.
CarefullyfollowallclearanceslistedintheappropriatesectionofthismanualANDfollowthe
ventingmanufacturer’sminimumclearancerequirements.Similarly,becertaintheventing
systemusedisapprovedformobilehomeuse.
InstallationmustbeinaccordancewithManufacturersHome&SafetyStandard(HUD)CFR3280,
Part24aswellasanyapplicablelocalcodes.
Usesiliconetocreateaneffectivevaporbarrieratthelocationwherethechimneyoroutsideair
ductingpassesthroughtotheexteriorofthestructure.
CAUTION
THESTRUCTURALINTEGRITYOFTHEMANUFACTUREDHOMEFLOOR,WALLANDCEILING/ROOFMUSTBE
MAINTAINED.DONOTCUTTHROUGHFLOORJOISTS,WALLSTUDS,CEILINGTRUSSESORANYOTHER
SUPPORTINGMATERIALWHICHCOULDBEDETRIMENTALTOTHESTRUCTURALINTEGRITYOFTHEHOME.
WARNING:DONOTINSTALLINASLEEPINGROOM.
JoistShield/FirestopMobileHomeApproved
TypeLorTypePLPellet
VentPipe
ChimneyCap/SparkArrestorRoofFlashingandStorm
Collar
Forhighaltitudeinstallations
(above4,000ft.),theventpipe
shouldbeincreasedfrom3inch
(3”)tofourinch(4”).
15
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
VENTTERMINATIONCLEARANCES
A)Min.4ftclearancebeloworbesideanydoororwindowthatopens.
B)Min.1ftclearanceaboveanydoororwindowthatopens.
C)Min.2ftclearancefromanyadjacentbuilding.
D)Min.7ftclearancefromanygradewhenadjacenttopublicwalkways.
E)Min.2ftclearanceaboveanygrass,plants,orothercombustiblematerials.
F)Min.3ftclearancefromaforcedairintakeofanyappliance.
G)Min.2ftclearancebeloweavesoroverhang.
H)Min.1ftclearancehorizontallyfromcombustiblewall.
I)Ventsinstalledwithmechanicalexhaustersshallterminatenotlessthan12in.(305mm)abovethe
highestpointwheretheypassthroughtheroofsurface.

NotesonterminationofPelletVentPipefromNFPA211(2006ed.)Section10.4Termination:10.4.5
(Seealso“INSTALLATION”sectionofmanualANDadditionalnotesabove):
Notlessthanthree(3)feetaboveanyforcedairinletlocatedwithinten(10)feet.
Notlessthanfour(4)feetbelow,four(4)feethorizontallyfrom,orone(1)footaboveanydoor,
windoworgravityairinletintoanybuilding.
Notlessthantwo(2)feetfromanadjacentbuilding,andnotlessthanseven(7)feetabovegrade
wherelocatedadjacenttopublicwalkways.
Theexhaustexitshallbearrangedsothatthefluegasesarenotdirectedsothatitwillaffectpeople,overheat
combustiblestructures,orenterbuildings.Forceddraftsystemsandallpartsofinduceddraftsystemsunderpositive
pressureduringoperationshallbeinstalledgastightortopreventleakageofcombustionproductsintoabuilding.
Throughthewallventsshallnotterminateoverpublicwalkways,orwherecondensateorvaporcouldcreatehazards
oranuisance.
Besuretofollowlocalcodesandallmanufacturer’sinstructions(includingexhaustpipe).
Consultaprofessionalinstallerand/orcallTechnicalSupportifyouhaveanyquestions.
16
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
OUTSIDEAIRHOOKUP
Theuseofoutsidecombustionairismandatoryonthispelletstove.
Theoutsideairconnectionpipeprotrudesfromthelowerrearcenterofthe
stove;usetheincludedoutsideairkittoattachyourstovetooutside
combustionair.Instructionsandallthepartsneededtomaketheoutsideair
connectiontoyourpelletstoveareincludedwiththeoutsideairkit.
Ifitisnotfeasibletousetheincludedoutsideairhookupkitinyourstove
installation,othermaterialsmaybeused,providedthefollowingrulesare
followed:
Thepipeusedforoutsideairhookupmustbemetal,withaminimum
thicknessof.0209in.(25gaugemildsteel)orgreaterandaninside
diameterofapproximately2.0in.
Allpipejointsandconnectionsshouldbesealedwithpipeclampsorother
mechanicalmeans,toinsurealeakfreeoutsideairconnection.
Longrunsofpipeandexcessiveelbowsforoutsideairshouldbeavoided.
Duetofrictionalresistanceinpipe,anyexcessiveoutsideairpipingcan
resultinpoorstoveperformance.
Ascreenorotherprotectiondevicemustbefittedovertheoutsideair
terminationpointtopreventrain,debrisandnuisanceanimalsfrom
enteringthepipingsystem.
Increasetheoutsideairpipesizeto3.0in.diameterpipeiftheoutsideair
connectionismorethan6ft.inlength,morethantwo(2)elbowsareused
orifthestoveisinstalledinabasement.
Theoutsideairconnectionsystemshouldbeinspectedatleastannuallytobe
certainitisfreefromblockage.
Caution
NEVERdrawoutsidecombustionairfrom:
1.Wall,floororceilingcavity.
2.Enclosedspacesuchasanattic,garageorcrawlspace.
17
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
FLOORPROTECTION
Thispelletstoverequiresanoncombustiblefloorprotectorifthestoveistobeinstalledonacombustible
floor.Ifthefloorthestoveistobeinstalledonisalreadynoncombustible(i.e.aconcretefloorina
basement)andhasanRvalueequaltoorhigherthan.2,nofloorprotectionisneeded(althougha
decorativefloorprotectorcanstillbeusedforaestheticreasons).
PrefabricatedfloorprotectorswhichareULlisted(ULCifCanada)orequivalentcanbepurchasedorafloor
protectorcanbebuiltfromstandardmaterials:twosheetsof.5”thickcementboardcoveredwithceramic
tilewouldbeasuitablefloorprotectorwhichmeetsthe.2Rvaluerequirement.
Whenusinganyfloorprotector,considerthatthisstoveisnotonlyheavybutwillinduceheatingand
coolingcyclesonthefloorprotectorwhichcandamagetileandloosenmortarandgroutjoints.Ahearth
rugisNOTanapprovedsubstituteforaproperhearthpad.
FortheUSandCanada:Thefloorprotectormustextendatleast6in.(152mm)fromthefront&sides.
InCanada,itisrequiredthatthenoncombustiblefloorprotectorisunderneathandextends2in.(50.8
mm.)oneithersideofanyhorizontalventingrunsAND/ORisdirectlyunderneathanyverticalventing
pipe.

18
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
DAILYOPERATION
GettingStarted
Checktoseethatthehopperiscleanandfreefromforeignmaterials.Besuretoconnectthisunittoa
workingoutlet;werecommendusingasurgeprotectortohelpprotecttheelectroniccomponentsfrom
damage.
BEFOREyourfirstfire,dryrunyourunit(nopelletfuelinthehopper)fortwentyminutes;pressingthe
“ON”buttonwiththeunitpluggedinwillinitiatethedryrun.
Oncethe“ON”buttonispressed,youshouldimmediatelyheartheexhaustblowerstartand
operatecontinuously.
Afteraboutthreetofiveminutes,lookfortheredglowoftheigniterintheigniterportoftheburn
pottobecertainitisoperatingnormally.
Holdthehopperlidswitch(See“IllustratedPartsDiagram”pg.44)downwithyourfingerandcheck
toseethattheaugeristurning.Releasethehopperlidswitchandbecertainthattheaugerstops
turning.DONOTPUTYOURFINGERSINTHEHOPPERORNEARTHEROTATINGAUGER.
Afterabouttwentyminutes,thecontrolboardshoulddisplay“E2”inthetwodisplaywindows(More
informationonErrorCodescanbefoundintheErrorCodesectionofthismanual).
Atthispoint,thedryruniscompleteandyourpelletheatingapplianceisreadyfornormaloperation.
LightingaFire
Inorderforthisstovetooperate,thehoppermustfirstbefilledwithpelletfuel.Liftthehopperlidusing
theflushmounthandleandpourthepelletfueldirectlyintothehopper.
WerecommendusingonlypelletsmanufacturedbyPFICertifiedfacilities,sincepelletsbearing
thePFIstampofapprovalwillbelowinashandmoisture,highinBTU’s,anduniforminsizeand
quality.
Thispelletstovewillperformequallywellusingsoftwoodandhardwoodpellets,andalthoughtheashmay
differslightlyinappearanceortexture,bothtypesofpelletswillburncleanlyandefficientlyinthisstove.
Thispelletstoveisequippedwithanautomaticpelletignitionsystem;theonlyuserinputrequiredtolight
thestoveisasimplepressofthe“On”button.
Shortlyafterpressingthe“On”button,thelettersSUwillappearintheheatrangeandblowerspeed
windowsofthecontrolboard.Thisindicatesthestovehasenteredthestartupsequenceandisoperating
normally.
Thefuelfeedrateandcombustionairduringstartupisdeterminedbythecontrolboard,sothestovemay
bestartedonanyheatrange.
Afterapproximatelyfifteenminutes,thefireshouldbeburningbrightlyandtheSUshoulddisappear
fromthecontrolboard.Atthispoint,thestovehasbegunnormaloperationandthedisplaywindowson
thecontrolboardwillremainempty,unlesstheHeatRangeorBlowerSpeedisadjusted.
19
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
Itisnormalfortheunittosmokeduringthefirstfire,aspaintsandoilscure.Thisshoulddissipatewithin
thefirsthour.Openadoorand/orwindowduringthefirstfiretoventilatethearea.

DailyOperationNotes
Onlyhighquality,PremiumGrade¼”(.25in.)diameterwoodpelletsshouldbeusedinthisstove.Using
lowgradewoodpelletswithhighashcontentORwoodpelletswithahighmoisturecontentcancausethe
burnpottofillwithashatamorerapidpaceandcancauseintervalsbetweenperiodicmaintenanceto
becomesignificantlyshorter.Pleasereadthe“Maintenance”sectionofthismanualthoroughlyto
understandhowfuelselectionaffectsstoveoperation,maintenanceandcleaning.
Variationintheflameheightisnormal;notallwoodpelletfuelisuniforminsize,whichcanaffecttheway
pelletsarefedintotheburnpot.Althoughtheflameheightmayincreaseanddecreaseduringoperation,
thereisnolossofefficiency.
Alwaysstorewoodpelletfuelinadrylocation;storingwoodpelletfuelinadrylocationensuresthefuel
willremainpelletizedandlowinmoisturecontent.Also,becertainthatallwoodpelletfuelisstoredata
safedistancefromthepelletheater;storingfuelincloseproximitytothestovecanresultinafire.Donot
installoroperatethisunitoutside,inagreenhouse,orinanyareathatishighinmoisture.
Thispelletburningroomheaterisequippedwithaspeciallydesignedburnpotwhichcomespreinstalled
fromthefactory.Thisburnpotelevatestheburningpelletsanddeliversairatthepreciselyrequired
locations.Pelletsmustonlybeburnedinthefactoryburnpot;nomodificationsshouldbemadetothis
burnpotandnoadditionalgratesorotherfireelevatorsshouldbeused.
CAUTION
NEVERUSEGASOLINE,GASOLINETYPELANTERNFUEL,KEROSENE,CHARCOALLIGHTERFLUID,OR
SIMILARLIQUIDSTOSTARTOR“FRESHENUP”AFIREINTHISHEATER.KEEPALLSUCHLIQUIDS
WELLAWAYFROMTHEHEATERWHILEINUSE.ADDITIONALLY,NEVERAPPLYFIRESTARTERTO
ANYHOTSURFACEOREMBERSINTHESTOVE.DONOTUSECHEMICALSORFLUIDS
TOSTARTTHEFIRE.
DONOTBURNFLAMMABLEFLUIDSSUCHASGASOLINE,NAPHTHAORENGINEOIL.
DONOTBURNGARBAGE;LAWNCLIPPINGSORYARDWASTE;MATERIALSCONTAININGRUBBER,
INCLUDINGTIRES;MATERIALSCONTAININGPLASTIC;WASTEPETROLEUMPRODUCTS,PAINTOR
PAINTTHINNERS,ORASPHALTPRODUCTS;MATERIALSCONTAININGASBESTOS;CONSTRUCTION
ORDEMOLITIONDEBRIS;RAILROADTIESORPRESSURETREATEDWOOD;MANUREORANIMAL
REMAINS;PAPERPRODUCTS,CARDBOARD,PLYWOODORPARTICLEBOARD.THEPROHIBITION
AGAINSTBURNINGTHESEMATERIALSDOESNOTPROHIBITTHEUSEOFFIRESTARTERSMADEFROM
PAPER,CARDBOARD,SAWDUST,WAXANDSIMILARSUBSTANCESFORTHEPURPOSEOFSTARTING
AFIREINANAFFECTEDWOODHEATER.BURNINGTHESEMATERIALSMAYRESULTINRELEASEOF
TOXICFUMESORRENDERTHEHEATERINEFFECTIVEANDCAUSESMOKE.
20
IMPORTANT!READANDFOLLOWALLINSTALLATIONANDMAINTENANCEINSTRUCTIONS,INCLUDINGCLEANINGTHEUNITASSPECIFIED,AND
REPLACINGGASKETSANNUALLY,ANDPARTSASNEEDED.
ENGLAND’SSTOVEWORKSISNOTRESPONSIBLEFORANYDAMAGEORINJURYINCURREDDUETONEGLECT,ORDUETOUNSAFEINSTALLATIONOR
USAGEOFTHISPRODUCT.CALLTECHNICALSUPPORTWITHANYQUESTIONS.
CONTROLBOARDSETTINGS
Thecontrolboardonthisstoveallowstheusertoadjusttheheatoutputandconvectionblowerspeed,turn
theunitonandoff,andtestcomponentsforfunction(moreondiagnosticmodelater).
Thelowerbuttonsonthecontrolboard(LowFuelFeed,LowBurnAir,andAironTemp)arenotmeantto
beadjustedduringnormaloperationoftheunit.Thesebuttonsarefactorypresetandcannotbeadjusted
bytheuser.
Toenergizetheunitandinitiateafire,pressthe“On”button.TheLEDabovethebuttonshouldturngreen
andthecontrolboardshoulddisplay“SU”shortlyafterpressingthebutton.
Toshuttheunitdown,pressthe“Off”button.TheLEDabovethebuttonshouldturnredandtheboard
shoulddisplay“Sd”shortlyafterpressingthebutton.Thisinitiatestheshutdownsequence,andthe
stovewillremaininshutdownmodeuntilithascooleddown.
Toincreasetheheatoutputofthestove,pressthe“Up”heatrangebutton.Thenumberintheheatrange
displaywindowwillincrease,signifyingthatthecontrolboardisnowadjustingtheheatoutputtoyour
desiredlevel.Theblowerspeedwillincreasethesameamountastheheatrange,becausethestoveis
designedtooperatewiththeblowerspeedgreaterthanorequaltotheheatrange.Pressingthe“Down”
arrowwilldecreasetheheatrangeandblowerspeed.
Toincreasetheblowerspeedwithoutincreasingtheheatrange,presstheBlowerSpeed“Up”arrowuntil
thedesiredblowerspeedisshowninthedisplaywindow.Pressingthe“Down”arrowwilldecreasethe
blowerspeed;however,thecontrolboardwillnotallowtheblowerspeedtobesetlowerthantheheat
range.
Caution
Thisunitismeanttooperateonlywiththemainviewingdoorclosed.Smoke
spillageandaninefficient,lazyburnwillresultfromattemptingtooperatethe
stovewiththedooropen.
Inaddition,usingfuelotherthanwoodpelletscancreateanunsafesituationand
canalsogenerateexcesscarbonmonoxide.Carbonmonoxideisanodorless,
colorlessgaswhichcanbedeadly.
BurnONLYwoodpellets.
CarbonMonoxideDetector
England’sStoveWorks,Inc.highlyrecommendstheuseofacarbonmonoxide
detectorintheproximityofthestoveandoneperfloorofthehome.
Acertainamountofcarbonmonoxideisproducedwithinthestoveasabyproductofcombustion.
AllexhaustventconnectionsmustbesealedwithRTVSiliconetoassureatightseal.Anyleaksinto
aconfinedareacausedbyfaultyinstallationorimproperoperationofthestovecouldproduce
dizziness,nauseaandinextremecases,death.TheCOconcentrationduringtestingwasfoundto
be0.013g/min.
/