Ancona AN-1157 User manual

Category
Cooker hoods
Type
User manual
®
Range Hood
WRP430 & WRP436
User Manual
&
Installation Instructions
IMPORTANT SAFETY INSTRUCTIONS
Carefully read the important information
regarding installation, safety and maintenance.
Keep these instructions for future reference.
MAAN-1156-01
— 2 —
INSTALLERS - Start Here
Safety Instructions are on pages 4 and 5 and
Installation Instructions are on pages 9 to 15.
Please perform these steps:
1. Read the safety instructions.
2. Read all instructions in the Installation section of
this manual BEFORE installing the range hood.
3. Remove all packing materials.
4. When nished, make sure to leave these instructions with the consumer.
5. Installation is to be done by a qualied technician only. However, the
ultimate responsibility for proper installation falls to the owner.
6.
Product failure due to improper installation is not covered under the Warranty.
CONSUMERS - Start Here
Safety Instructions are on pages 4 and 5 and Operating Instructions are
on pages 16 and 17.
Please perform these steps:
1. Read the safety instructions.
2. Read all instructions in the manual BEFORE operating the range hood.
3. Remove all packing materials.
4. Installation is to be done by a qualied technician only. However, the
ultimate responsibility for proper installation falls to the owner.
5.
Product failure due to improper installation is not covered under the Warranty.
Before You Begin
Hardware Note: For safety reasons, range hood mounting screws and anchors will not be
included due to the variation of cabinetry constructions and wall material. Please consult your
installation specialist regarding the optimal type of mounting screws and wall anchors to suit your
home’s construction.
— 3 —
Before You Begin ............................................................................................................................... 2
Table of Contents .............................................................................................................................. 3
Important Safety Information ............................................................................................................ 4
Included Parts ................................................................................................................................... 6
Range Hood Dimensions .................................................................................................................. 7
Specications .................................................................................................................................... 7
Mounting Brackets ............................................................................................................................ 8
Installation ......................................................................................................................................... 9
Step 1 - Read the Safety Instructions ............................................................................................ 9
Step 2 - Unpack Range Hood and Prepare Tools .......................................................................... 9
Step 3 - Plan Desired Location ...................................................................................................... 9
Step 4 - Test Unit Functions .......................................................................................................... 9
Step 5 - Venting Installation Guidelines ....................................................................................... 10
Step 6 - Preparations ................................................................................................................... 12
Step 7 - Installing the hood mounting bracket ............................................................................ 12
Step 8 - Installing the upper chimney bracket ............................................................................. 12
Step 9 - Venting ........................................................................................................................... 13
Step 10 - Mount Range Hood Onto Wall ..................................................................................... 13
Step 11 - Install Chimney ............................................................................................................. 13
Step 12 - Connect Ductwork ....................................................................................................... 14
Step 13 - Connect to AC.............................................................................................................. 14
Step 14 - Install Filters ................................................................................................................. 15
Operation ........................................................................................................................................ 16
Time/Delay (Double Function Button) .......................................................................................... 16
Lighting ........................................................................................................................................ 16
Blower .......................................................................................................................................... 16
Maintenance.................................................................................................................................... 17
Replacing the Light Bulbs ............................................................................................................ 17
Range Hood Assembly ................................................................................................................... 18
Assembly ......................................................................................................................................... 19
Circuit Diagram ............................................................................................................................ 19
Blower Assembly ......................................................................................................................... 19
Electrical Assembly ...................................................................................................................... 19
Use and Care Information ............................................................................................................... 20
Table of Contents
— 4 —
Important Safety Information
• Theinstallationinthismanualisintended
for qualied installers, service technicians or
persons with a similar qualied background.
Installation must be done by qualied
professionals and in accordance with all
applicable codes and standards, including
re-rated construction.
•
The range hood may have very sharp
edges; please wear protective gloves if it is
necessary to remove any parts for installing,
cleaning or servicing.
•
Activating any switch to ON position before
completing installation may cause damage or
electric shock.
• Duetothesizeofthisrangehood,atwo
person installation is recommended.
To reduce the risk of re, electric shock, or
injury to persons:
• Forgeneralventilatinguseonly.DO NOT use
toexhausthazardousorexplosivematerials
and vapors.
• WARNING: To Reduce The Risk Of Fire Or
Electric Shock, Do Not Use This Fan With Any
Solid-State Speed Control Device.
• Thecombustionairowneededforsafe
operation of fuel-burning equipment may be
affected by this unit’s operation. Follow the
heating equipment manufacturer’s guideline
and safety standards such as those published
by the National Fire Protection Association
(NFPA), and the American Society of Heating,
Refrigeration and Air Conditioning Engineers
(ASHRAE), and other local code authorities.
• Beforeservicingorcleaningtheunit,switch
power off at service panel and lock the service
disconnecting means to prevent power from
being switched on accidentally. When the
service disconnecting means cannot be
locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
• Cleangrease-ladensurfacesfrequently.To
optimizeperformanceandtodisperseair
properly, make sure to vent air outside. DO
NOT vent exhaust into spaces between walls,
crawl spaces, ceilings, attics or garages.
•
Ducted fans MUST always be vented to
the outdoors.
• ThisunitMUSTbegroundedandusedwith
metal ductwork only.
• Sufcientairisneededforpropercombustion
and exhausting of gases through the duct to
prevent back drafting.
• Whencuttingordrillingintowallorceiling,be
careful not to damage electrical wiring or other
hidden utilities.
• Allelectricalwiringmustbeproperlyinstalled,
insulated and grounded.
•
Old ductwork should be cleaned or replaced
if necessary to avoid the possibility of a
grease re.
•
Check all joints on ductwork to ensure
proper connection; all joints should be
properly taped using a certied aluminum
or foil tape.
• Usethisunitonlyinthemannerintended
by the manufacturer. If you have questions,
contact the vendor.
READ AND SAVE THESE
INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
Read and follow all instructions before using the range hood to prevent the risk of re, electric shock,
personal injury, or damage when using the range hood or appliances with the range hood. This guide
does not cover all possible conditions that may occur. Always contact your service technician or
manufacturer about problems that you do not understand.
— 5 —
Important Safety Information
WARNING: TO REDUCE RISK OF A RANGE
TOP GREASE FIRE:
a) Never leave surface units unattended at high
settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils slowly on
low or medium settings.
b) Always turn range hood ON when cooking at
highheatorwhenambéingfood(i.e.Crepes
Suzette,CherriesJubilee,etc.).
c)
Clean ventilating fans frequently. Grease should
not be allowed to accumulate on fan or lter.
Before servicing or cleaning unit, unplug and
disconnect the hood from the power supply.
d)Useproperpansize.Alwaysusecookware
appropriateforthesizeofthesurfaceelement.
WARNING: TO REDUCE RISK OF INJURY TO
PERSONS IN THE EVENT OF A RANGE TOP
GREASE FIRE, OBSERVE THE FOLLOWING *
a) S
MOTHER FLAMES with a close-tting
lid, cookie sheet, or metal tray, then turn
off the burner. BE CAREFUL TO PREVENT
BURNS.Iftheamesdonotgoout
immediately, EVACUATE AND CALL THE
FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - You may
be burned.
c) DO NOT USE WATER, including wet dishcloths
or towels - a violent steam explosion will result.
d) Use an extinguisher ONLY if:
1) You know you have a Class A, B, C
extinguisher, and you already know how to
operate it.
2) The re is small and contained in the area
where it is started.
3) The re department is being called.
4)
You can ght the re with your back to an exit.
* Based on “Kitchen Fire Safety Tips”
published by NFPA
To reduce the risk of injury to persons in the
event of a gas leaks:
• Extinguishanyopename.
•
DO NOT turn on the lights or any type of appliance.
• Openalldoorsandwindowstodispersethe
gas. If you still smell gas, call the gas company
and re department.
Your safety and the safety of others is very
important. We have provided many important
safety messages in this manual and on your
appliance. Always read and obey all safety
messages. All safety messages outline any
potentialhazards,howtoreducethechanceof
injury, and possible risks if the instructions are not
followed.
READ AND SAVE THESE
INSTRUCTIONS
— 6 —
Included Parts
Main Housing
Upper Chimney
Lower Chimney
Upper Chimney Bracket
Hardware Note: For safety reasons, range hood mounting screws and anchors will not be included due to
the variation of cabinetry constructions and wall material. Please consult your installation specialist regarding
the optimal type of mounting screws and wall anchors to suit your home’s construction.
Lower Chimney Bracket
Hood Mounting Bracket
30” Filters (x2)
36” Filters (x3)
4 x Damper Screws (A)
4 x Chimney Screws (B)
— 7 —
Range Hood Dimensions
Specications
Body Design Stainless Steel
Power Rating 120V/60Hz(cETLusCertied)
Total Input Power 215 W (210W+2*2.5W)
Motor Input Power 210 W
Amperage 1.8 A
Speed Control Levels 3 Speeds
Interference Protection Radio Frequency Interference Protected
Noise Level (50db)/(55db)/(60db)
Motors Single Motor
Control LCD touch control panel
Filtration Aluminum lter, stainless steel surface
Illumination 2x2.5W LED 4V maximum
Fan Type Centrifugal squirrel cage
VentingSize Top, 6 inches round
30” (76.2 cm) or 36” (91.4 cm)
— 8 —
Mounting Brackets
— 9 —
STEP 1
Read the Safety Instructions
• It is very important to read the safety instructions on pages 4 and 5.
IMPORTANT: It is the installer’s responsibility to comply with installation clearances.
STEP 2
Unpack Range Hood and Prepare Tools
• Carefully unpack the range hood and parts. Make sure all parts are included as shown on page 6.
• DO NOT remove the protective lm covering the appliance until the installation is fully completed.
• Consult a qualied and trained installer or check local codes for makeup air requirement, if any.
STEP 3
Plan Desired Location
• Plan a desirable location that ts all requirements in the Safety and Installation sections of this manual. Plan where
and how the ductwork will be installed.
• A straight or short duct run will allow the unit to perform most efciently. Long duct runs, elbows and transitions
willreducetheperformanceoftheunit.Eachelbowisequivalentto5to10feetofstraightrun.Propersizeduct
work should be 7” (178 mm) in diameter.
• To reach a 9 foot ceiling make sure hood is installed 30 inches from cooking surface. If you have a ceiling
greater than 9ft, please visit anconahome.com to order a chimney extension.
• If ductwork is already installed: ensure ductwork is free from debris and measures 7”
(178 mm)
(1” reducers may be
used but more than 1” will overwork the motor and the unit will not function properly).
STEP 4
Test Unit Functions
• Plug the unit in and test all of the functions before installing.
• Placetherangehoodonaat,stablesurface.Connecttherangehoodtoadesignatedstandardoutlet(120-Volt,60Hz,
AC only) and turn on the range hood. Verify all operations of the range hood by referring to
Range Hood Operations.
• Turn power On in control panel.
• Check all lights and fan operations.
WARNINGS:
• PleasemakesuretoreadALLsafetyinstuctionsonpages4and5.
• Usetwoormorepeopletomoveandinstallrangehood.
• Failuretofollowtheseinstructionscanresultinseriousinjury.
Installation
— 10 —
Installation
STEP 5
Venting Installation Guidelines
• The following steps are for exterior ventilation.
• If you require a ductless installation, please visit anconahome.com to purchase a recirculation kit.
Height and Clearance
IMPORTANT:
•
Vent system must terminate to the outside (roof or side wall).
• DONOT
terminate the vent system in an attic or other
enclosed area.
• DONOTuse4”(10.2cm)laundry-typewallcaps.
• Usemetal/aluminumventonly.Arigidmetal/aluminum
vent is recommended.
• DONOTuseaplasticvent.
• Alwayskeeptheductcleantoensureproperairflow.
• Calculatethefollowingfiguresbeforeinstallation:
1. Distance from the floor to the ceiling
2. Distance between the floor and the countertop/stove
3.
A distance of 24” to 30” is recommended between
stove top and the bottom of range hood. 30” minimum
is required for gas stove tops.
4. Height of hood and duct cover.
For the most efficient & quiet operation:
• Itisrecommendedthattherangehoodbevented
vertically through the roof through 10” (15.3 cm) or
bigger round metal/aluminum vent work.
• Thesizeoftheventshouldbeuniform.
• Usenomorethanthree90°elbows.
•
Make sure there is a minimum of 24” (61 cm) of
straight vent between the elbows if more than one
elbow is used.
• DONOTinstalltwoelbowstogether.
•
The length of vent system and number of elbows should be
kept to a minimum to provide efficient performance.
• Theventsystemmusthaveadamper.Ifrooforwall
cap has a damper, you may remove damper flaps from
damper to increase air flow.
• Onlyoneflangeisneededintheaireductsystem,
either on top of the motor or outside.
•
Use silver tape or duct tape to seal all joints in the
vent system.
•
Use caulking to seal exterior wall or roof opening
around the cap.
24” (610 mm) Min / 30(762 mm) Max
To reach 9 ft ceiling, make sure
range hood is installed at least
30” (762 mm) from cooking surface.
— 11 —
IMPORTANT:
•
A minimum of 6” round or 3-1/4 x 10” rectangular duct
(purchased separately) must be used to maintain maximum
airflow efficiency.
• Alwaysuserigidtypemetal/aluminumductsifavailableto
maximizeairflowwhenconnectingtoprovidedduct.
• PleaseuseDuctRunCalculationbelowtocompute
total available duct run when using elbows, transitions
and caps.
• ALWAYS,whenpossible,reducethenumberor
transitions and turns. If long duct run is required,
increaseductsizefrom6”to7”or8”.Ifareducer
is used, install a long reducer instead of a pancake
reducer.Reducingductsizewillrestrictairflowand
decreaseairflow,thusreduceductsizeasfaraway
from opening as possible.
• Ifturnsortransitionsarerequired,installasfaraway
from opening and as far apart, between two (2), as
possible.
• Minimummountheightbetweenstovetoptohood
bottom should be no less than 24-inch for electric cook
tops and minimum of 30-inch for gas stove tops and no
higher than 30-inch for electric cook tops.
• Itisimportanttoinstallthehoodatthepropermounting
height. Hoods mounted too low could result in heat
damageandfirehazard;whilehoodsmountedtoohigh
may be hard to reach and will lose its performance and
efficiency.
• Ifavailable,alsorefertostovetopmanufacturer’s
height clearance requirements and recommended
hood mounting height above range.
Installation
• This range hood is factory set for venting through the roof or wall.
• Ventworkcanterminateeitherthroughtherooforwall.Toventthroughawall,a90°elbowisneeded.
IMPORTANT:
• NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or
garages. All exhaust must be ducted to the outside.
• Use metal/aluminum duct work only.
• Fasten all connections with sheet metal screws and tape all joints with certied Silver Tape or Duct Tape.
• Use caulking to seal exterior wall or roof opening around the cap.
— 12 —
Installation
STEP 6
Preparations:
NOTE: To avoid damage to your hood, prevent debris from entering the vent opening.
• Determine and mark the center line on the ceiling or wall where the range hood will be installed.
• Make sure there is proper clearance within the ceiling or wall for exhaust vent.
• Duetotheweightandsizeofthisunit,pleasemakesurethatthesupportsystemorframeworkbeingusedisstableand
secure in the ceiling or wall.
• Put a thick, protective covering over counter top, cook top or range to protect from damage or dirt.
• Removeanyhazardousobjectsaroundtheareawheninstalling.
CAUTION
If moving the cooking range is necessary to install the hood, turn OFF the power on an electric range at the main
electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE
STEP 7
Installing the hood mounting bracket
• Use a pencil to mark on the wall the desired placement of the range hood mounting screws.
• The range hood will be installed on top of this bracket (See Figure # 1).
• Using references in Height & Clearance on Page 10 and Measurements and Diagrams on Page 7, drill 3 holes that will
be used to x the lower mounting bracket.
STEP 8
Installing the upper chimney bracket
• Drill2holesaccordingtothesizeoftheuppermountingbracket.Theuppermountingbracketshouldbepositioned
ushwiththetopoftheoutsidechimney(SeeFigure1)
• Screw upper and hood mounting brackets in tightly.
190
115
115
Fig #1
Flush to the ceiling
— 13 —
Installation
STEP 10
Mount Range Hood Onto Wall
• Hang the range hood on the hooks of the lower
mounting bracket. (See Figure # 3)
• Screw the range hood to the wall.
CAUTION - Make sure the range hood is secure
before releasing!
STEP 9
Venting
• Fix the damper on the top vent of hood with 4 screws (A).
• If ventilation system is equipped with an external
air duct with a different diameter, apply a reduction
tting. However, for maximum performance and
safety, a 6” round ducting is recommended.
STEP 11
Install Chimney
• Place chimney on top of the main housing.
• Remove the protective coating from the upper chimney. Carefully slide the upper chimney down into the lower chimney.
• Use 2 screws (B) to x the two chimneys together with the lower chimney bracket, make sure upper chimney is moving
freely. (See Figure # 4)
• Screw the upper chimney to the upper mounting bracket (B). (See Figure # 5)
Fig #2
Fig #3
Fig #4
Fig #5
— 14 —
STEP 12
Connect Ductwork
• Attach ductwork to damper. Secure the ductwork with duct tape to make sure joints are secure and air- tight.
• Donotinstalltheducttapetootightlyasthismaypreventthedamperapsfromopeningwhichwilloverworkthemotor
and cause improper functioning of the unit.
• Fasten all connections with sheet metal screws and tape all joints with certied aluminum or foil tape. Use caulking to
seal exterior wall or roof opening around the cap.
STEP 13
Connect to AC
• Connect AC plug into a grounded AC outlet
having120V,60Hz.Placetheoutletatamaximum
distance of 33-1/2” (851 mm) from where the cord
exits on the hood.
3-Pronged Plug
Ground Plug
3-Prong Receptacle
IMPORTANT:
• Observeallgoverningcodesandordinances.
• It is the customer’s responsibility to contact a qualified electrical installer.
• Ifcodespermitandaseparategroundwireisused,itisrecommendedthataqualifiedelectriciandeterminethat
thegroundpathisadequate.A120-Volt,60Hz,AC-only,fusedelectricalsupplyisrequiredonaseparate15-amp
circuit, fused on both sides of the line.
• DONOTgroundtoagaspipe.
• Checkwithaqualifiedelectricianifyouarenotsurethattherangehoodisproperlygrounded.
• DONOThaveafuseintheneutralorgroundcircuit.
IMPORTANT: Save this Installation Guide for electrical inspector’s use.
GROUNDING INSTRUCTIONS:
• Thisappliancemustbegrounded.Intheeventofanelectricalshort-circuit,groundingreducestheriskofelectric
shock by providing an escape wire for the electric current.
• Thisapplianceisequippedwithacordhavingagroundingwirewithagroundingplug.Theplugmustbeplugged
into an outlet that is properly installed and grounded.
WARNING: Improper grounding can result in a risk of electric shock.
• Consultaqualifiedelectricianifthegroundinginstructionsarenotcompletelyunderstood,orifdoubtexistsasto
whether the appliance is properly grounded. DO NOT use an extension cord. If the power supply cord is too short,
have a qualified electrician install an outlet near the appliance.
• Therangehoodmustbeconnectedwithcopperwire/plugonly.Therangehoodshouldbeconnecteddirectlyto
the fused disconnect (or circuit breaker) box through flexible armored or non-metallic sheathed copper cable. UL/
CSA listed strain relief must be provided at each end of the power supply cable.
Installation
— 15 —
Installation
STEP 14
Install Filters
To install lters for the following four steps (See Figure # 6):
• Angle the lter into slots at the back of the hood.
• Push the button on handle of the lter.
• Release the handle once the lter ts into a resting position.
• Repeat to install all lters.
Cleaning Filters
IMPORTANT: Drain oil from bafes, spacers, lters, oil tunnels, oil containers before oil and residue overow!
• Removeallbafes,spacers,lters,greasetray,andoilcontainersanddiscardoilandresidue.
• Washwithwarmsoapywater.NOTE:Stainlesssteelbafes,spacersandoiltunnelaretoprackdishwashersafe.
• Dry thoroughly before replacing and follow directions for installation in reverse.
• Filters should be cleaned after every 30 hours of use.
• Should lters wear out due to age and prolonged use, replace with a new lter.
Fig #6
— 16 —
Operation
Time/Delay (Double Function Button)
Time Setting: This button is used to set time when lighting
and blower are not in use. Time is displayed in 24 hour
cycle. To set time;
u
Press the button (1) for 4 seconds. The rst two digits
willash.
v
Use the blower button (3) to increase and the lighting
button (2) to decrease.
w
Press the time/delay button (1) again, the last two
digitswillash.Usetheblowerbutton(3)toincrease
and the lighting button (2) to decrease.
x
Press the time/delay button (1) again to conrm and
exit time setting mode.
Delay Setting: When blower is in use, this button is the
delay setting button. To set delay;
u
Press the button (1). The delay is factory set at 5
minutes, but can be set from 1 up to 60 minutes.
v
Use blower button (3) to increase and lighting button
(2) to decrease. Countdown will be displayed on the
LCD screen and blower symbol will be activated.
Blower will continue to operate for the programmed
minutes and then will stop automatically (delay
setting mode does not affect lighting as it works
independently).Thelasttimeusedwillbememorized.
w
To cancel delay function, press time/delay button (1)
again, the blower will continue to operate and won’t
stop until ON/OFF button (4) is pressed.
x
To turn delay function and blower OFF at once, press
ON/OFF button (4).
Lighting
u
Pressing the lighting button (2) once will turn the
LCD screen on.
v
To turn the lights on, press the lighting button (2)
once more. Press it again to turn the lights OFF.
The LCD screen will turn automatically off after 15
seconds of inactivity (blower and/or lights).
Blower
The blower button (3) turns the blower on to three speed
settings: LOW, MEDIUM or HIGH.
u
Press the blower (3) or ON/OFF (4) button once to
turn the LCD screen on. Pressing the blower (3) or
ON/OFF (4) button once more will turn the blower on
at the last selected speed and blower symbol will be
activated.
v
To change the blower speed, press the blower
button (3) until the desired speed is obtained.
w
Press the ON/OFF button (4) to turn the blower OFF.
Thelastspeedusedwillbememorized.
— 17 —
u
Make sure the range hood is unplugged or turn OFF
breaker.
v
Open the lter and nd the spring of the light.
w
Push the spring and the lights will slip out.
CAUTION: BULB MAY BE HOT, PLEASE TAKE OUT
THE BULB WHEN THE BULB IS COMPLETELY
COOL!
x
Replace with a 4 Volt, 2.5Watt max, LED lights. Do
not touch replacement bulb with bare hands!
y
Turn ON breaker and range hood to test for
operation.
Maintenance
Replacing the Light Bulbs
IMPORTANT:
ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY AT THE MAIN PANEL BEFORE CARRYING OUT ANY OPERATION
ON THE APPLIANCE.
— 18 —
Range Hood Assembly
Number Part Quantity
1 Recirculation Kit (Not
Included)
1
2 Duct Tube (Not
Included)
1
3 Upper chimney 1
4 Lower chimney 1
5 Bracket for Upper
chimney
1
6 Bracket for Lower
chimney
1
7 Vent/damper 1
8 Mounting bracket 1
9 Power cord 1
10 Housing assembly 1
11 Control panel
assembly
1
12 Electronic box 1
13 PCB board 1
14 Capacitor 1
15 Base of electronic
box
1
16 Transformer 1
17 Transformer box 1
18 Light panel assembly 1
19 LED Lights 2
20 Blower assembly 1
21 Charcoal support 2
22 Charcoal lter (Not
included)
1
23 Bracket for control
panel
1
24 Control panel 1
25 Filters 30”
Filters 36”
2
3
26 Screw bag 1
— 19 —
Assembly
Circuit Diagram
Blower Assembly
Electrical Assembly
Number Part
1 Grid
2 Blower
3 Impeller
4 Motor
Number Part
1 Electrical Box Base
2 PCB
3 Electrical Cover
4 Capacitor
5 Screw (ST3*10)
6 Screw (ST3*6)
— 20 —
Use and Care Information
Operations
• Read and understand all instructions and warnings in this manual before operating the appliance. Save these
instructions for future reference.
• Always leave safety grills and lters in place. Without these components, operating fans could catch on to hair, ngers
and loose clothing.
• NEVER dispose cigarette ashes, ignitable substances, or any foreign objects into fans.
• NEVER leave cooking unattended. When frying, oil in the pan can easily overheat and catch re. The risk of self
combustion is higher when the oil has been used several times.
• NEVERcookon“open”amesundertherangehood.Checkdeep-fryersduringuse;superheatedoilmaybe
ammable.
Cleaning
• Thesaturationofgreasyresidueinthefanandltersmaycauseincreasedinammability.Keepunitcleanandfreeof
grease and residue build-up at all times to prevent possible res.
• Filters must be cleaned periodically and free from accumulation of cooking residue (see Cleaning Instructions below).
Old and worn lters must be replaced immediately.
• DO NOT operate fans when lters are removed. Never disassemble parts to clean without proper instructions.
Disassembly is recommended to be performed by qualied personnel only. Read and understand all instructions and
warnings in this manual before proceeding.
SAFETY WARNING: Never put your hand into area housing the fan while the fan is operating!
For optimal operation, clean range hood and all bafe/spacer/lter/grease tray/oil container regularly. Regular care
will help preserve the appearance of the range hood.
Cleaning Exterior Surfaces:
• Clean periodically with hot soapy water and clean cotton cloth. DO NOT use corrosive or abrasive detergent (e.g. Comet
Power Scrub®, EZ-Off® oven cleaner), or steel wool/scoring pads, which will scratch and damage the stainless steel
surface. For heavier soil use liquid degrease such as “Formula 409®” or “Fantastic®” brand cleaner.
• If hood looks splotchy (stainless steel hood), use a stainless steel cleaner to clean the surface of the hood. Avoid getting
cleaning solution onto or into the control panel. Follow directions of the stainless steel cleaner. CAUTION: DO NOT
leave on too long as this may cause damage to hood nish. Use soft towel to wipe off the cleaning solution, gently
rub off any stubborn spots. Use dry soft towel to dry the hood.
• After cleaning, you may use non abrasive stainless steel polish such as 3M® or ZEP®, to polish and buff out the
stainless luster and grain. Always scrub lightly, with clean cotton cloth, and with the grain.
• DO NOT allow deposits to accumulate or remain on the hood.
• DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface and cause rusting.
• DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel
for extended periods. Many of these compounds contain chemicals, which
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21

Ancona AN-1157 User manual

Category
Cooker hoods
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI