Elation FUZE PAR Z175 User manual

  • Hello! I am an AI chatbot trained to assist you with the Elation FUZE PAR Z175 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
FUZEPARZ175™
usermanual

ELATION
|
FUZE PAR Z175
|
user manual
www.elationlighting.com
FUZE PAR Z175™ User Manual
2
©2017 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images,
and instructions herein are subject to change without notice.ELATION PROFESSIONAL logo and
identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL.
Copyright protection claimed includes all forms and matters of copyrightable materials and
informationnowallowedbystatutoryorjudiciallaworhereinaftergranted.Productnamesusedin
thisdocumentmaybetrademarksorregisteredtrademarksoftheirrespectivecompaniesandare
hereby acknowledged. All nonELATION brands and product names are trademarks or registered
trademarksoftheirrespectivecompanies.
ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for
property,equipment,building,andelectricaldamages,injuriestoanypersons,anddirectorindirect
economic loss associated with the use or reliance of any information contained within this
document, and/or as a result of the improper, unsafe, insufficient and negligent assembly,
installation,rigging,andoperationofthisproduct.
ElationProfessionalUSA|6122S.EasternAve.|LosAngeles,CA.90040
3235823322|3238329142fax|www.elationlighting.com|info@elationlighting.com
ElationProfessionalB.V.|Junos traat2|6468EWKerkrade,TheNetherlands
+31455468566|+31455468596fax|www.elationlighting.eu|[email protected]
DOCUMENT VERSION
Pleasecheckwww.elationligh ting.comforthelat estr evision/updateofthismanual.
Date
Document
Version
Software
Version≥
DMX
ChannelModes
Notes
04/06/17 1 1.02 6/7/8/12 Initialrelease.
06/12/17 1.2 N/C N/C Updatedtechnicalspecpage.
01/04/21 1.4 1.07
4/5/52/6/7/8/82/83/
9/10/102/11/112/
113/12/13/14/15
UpdatedSoftwaretoV1.06

www.elationlighting.com
FUZE PAR Z175™ User Manual
3
CONTENTS
General Information 4
Warranty 6
SafetyInstructionsandGuidelines 7
Overview 9
Installation 10
SystemMenu 12
DMXChannelFunctionsAndValues 16
CleaningandMaintenance 20
TechnicalSpecifications 21
OptionalAccessories 23
www.elationlighting.com
FUZE PAR Z175™ User Manual
4
GENERAL INFORMATION
INTRODUCTION
Congratulations, you have just purchased one of the most innovative and reliable IP65 rated
lighting fixtures on the market today! This fixture has been designed to perform reliably for
years when the guidelines in this booklet are followed. Please read and understand the
instructions in this manual carefully and thoroughly before attempting to operate this unit.
Theseinstructionscontainimportantinformationregardingsafetyduringuseandmaintenance.
UNPACKING
Everyfixturehasbeenthoroughlytested andhasbeen shippedinperfectoperating condition.
Carefullychecktheshippingcarton fordamagethat mayhaveoccurredduring shipping.Ifthe
carton appears to be damaged, carefully inspect your unit for damage and be sure all
accessories necessary to operate the unit have arrived intact. In the event damage has been
foundorparts aremissing, please contactour customersupport teamforfurtherinstructions.
Please do not return this unit to your dealer without first contactingcustomer support at the
number liste d below. Please do not discard the shipping carton in the trash. Please recycle
wheneverpossible.
BOXCONTENTS
(1)GelFrame(attached)
(1)GelFrame/BarnDoorHolder(attached)
(1)BarnDoor(attached)
(1)powerCONCable

www.elationlighting.com
FUZE PAR Z175™ User Manual
5
CUSTOMERSUPPORT
ElationProfessional
®
providesacustomersupportline,toprovidesetuphelpandtoanswerany
questionshould you encounte r problemsduring your set up orinitial operation.You mayalso
visit us on the web at www.elationlighting.com for any comments or sug gestions. For service
relatedissuepleasecontactElationProfessional®.
ELATIONSERVICEUSAMondayFriday8:00amto5:00pmPST
Voice:3235823322 Fax:3238329142
Email:[email protected]om
ELATIONSERVICEEUROPEMondayFriday08:30to17:00CET
Voice:+31455468530 Fax:+31455468596
Email:[email protected]
WARRANTYRETURNS
All returned service items whether under warranty or not, must be freight prepaid and
accompany a return authorization (R.A.) number. The R.A. number mustbe clearly written on
theoutside ofthereturnpackage.Abriefdescription oftheproblemaswellastheR.A.number
mustalsobewrittendownonapieceofpaperandincludedintheshippingcontainer.Iftheunit
is under warranty, you mustprovide a copy of your proof of purchase invoice. Items returned
without a R.A. number clearly marke d on the outside of the package will be refused and
returnedatcustomersexpense.YoumayobtainaR.A.numberbycontactingcustomersupport.
IMPORTANT NOTICE!
Therearenouserserviceablepartsinsidethisunit.Donotattemptanyrepairsyourself;doing
sowillvoidyourmanufactureswarranty.Damagesresultingfrommodificationstothisfixture
and/orthedisregardofsafetyandgeneraluserinstructionsfoundinthisusermanualvoidthe
manufactures warrantyandarenotsubjecttoanywarrantyclaimsand/orrepairs.
www.elationlighting.com
FUZE PAR Z175™ User Manual
6
LIMITED WARRANTY
A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to be free of
manufacturingdefectsinmaterialandworkmanshipforaperiodoftwoyears(730days),andElationProfessional®
productrechargeablebatteriestobefreeof manufacturingdefectsinmaterialandworkmanshipforaperiodofsix
months (180 days), from the original date of purchase. This warranty excludes discharge lamps and all product
accessories. This warranty shall be valid only if the product is purchased within the United States of America,
includingpossessionsandterritories.Itistheownersresponsibilitytoestablishthedateandplace
ofpurchaseby
acceptableevidence,atthetimeserviceissought.
B. For warranty service, send the product only to the Elation Professional® factory . All shipping charges must be
prepaid. If the requested repairs or service (including parts replacement) are within the terms of this warranty,
Elation Professional® will pay
return shipping charges only to a designated point within the United States. If any
productissent,itmustbeshippedinitsoriginalpackageandpackagingmaterial.Noaccessoriesshouldbeshipped
withtheproduct.Ifanyaccessoriesareshippedwiththeproduct,ElationProfessional®shallhavenoliability
what
soeverforlossand/orordamagetoanysuchaccessories,norforthesafereturnthereof.
C. Thiswarrantyisvoidiftheproductserialnumberand/orlabelsarealteredorremoved;iftheproductismodifiedin
any manner which Elation Professional® concludes, after inspection, affects the reliability
of the product; if the
producthasbeenrepairedorservicedbyanyoneotherthantheElationProfessional®factoryunlesspriorwritten
authorization was issued to purchaser by Elation Professional®; if the product is damaged because not properly
maintainedassetforthintheproductinstructions,guidelinesand/orusermanual.
D. Thisisnot aservicecontract,andthiswarrantydoesnotincludeanymaintenance,cleaningorperiodiccheckup.
During the periods as specified above, Elation Professional® will replace defective parts at its expense, and will
absorb all expenses forwarrantyservice and repair laborby reason ofdefectsin
materialorworkmanship.The
sole responsibility of Elation Professional® under this warranty shall be limited to the repair of the product, or
replacement thereof, including parts, at the sole discretion of Elation Professional®. All products covered by this
warrantyweremanufacturedafterJanuary1,1990,andbareidentifyingmarksto
thateffect.
E. Elation Professional® reserves the right to make changes in design and/or performance improvements upon its
productswithoutanyobligationtoincludethesechangesinanyproductstheretoforemanufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with the
products
describedabove.Excepttotheextentprohibitedbyapplicablelaw,allimpliedwarrantiesmadebyElation
Professional® in connection with this product, including warranties of merchantability or fitness, are limited in
duration to the warranty periods set forth above. And no warranties, whether expressed or implied, including
warrantiesofmerchantability
orfitness,shallapplytothisproductaftersaidperiodshaveexpired.Theconsumers
and/or dealers sole remedy shall be such repair or replacement as is expressly provided above; and under no
circumstancesshallElationProfessional®beliableforanylossand/ordamage,directand/orconsequential,arising
outoftheuse
of,and/ortheinabilitytouse,thisproduct.
G. This warranty is the only written warranty applicable to Elation Professional® products and supersedes all prior
warrantiesandwrittendescriptionsofwarrantytermsandconditionsheretoforepublished.

www.elationlighting.com
FUZE PAR Z175™ User Manual
7
SAFETYINSTRUCTIONSANDGUIDELINES
This fixture is an extremely sophisticated piece of electronic equipment. To guarantee a smooth
operation,itisimportanttofollowallinstructionsandguidelinesinthismanual.Themanufacturer
ofthisdeviceisnotresponsibleforinjuryand/ordamagesresultingfromthemisuseofthisfixture
due to the disregard of the information printed in this manual. Only qualified and/or certified
personnel should perform installation of this fixture and only the original rigging parts (omega
brackets)includedwiththisfixtureshouldbeusedforinstallation. Anymodificationstothefixture
and/orthemountinghardwareincluded willvoidtheoriginalmanufactureswarrantyandincrease
theriskofdamageand/orpersonalinjury.
PROTECTIONCLASS1‐FIXTUREMUSTBEPROPERLYGROUNDED
DONOTPLUGFIXTUREINTOADIMMERPACK!
NEVEROPENTHISFIXTUREWHILEINUSE!
UNPLUGPOWERBEFORESERVICINGFIXTURE!
NEVERTOUCHFIXTUREDURINGOPERATION, ASITMAYBEHOT!
KEEPFLAMMABLEMATERIALSAWAYFROMFIXTURE!
INDOOR/DRYLOCATIONSUSEONLY!
DO
NOTEXPOSEFIXTURETORAINANDMOISTURE!
NEVERLOOKDIRECTLYINTOTHELIGHTSOURCE!
RETINAINJURYRISK‐MAYINDUCEBLINDNESS!
SENSITIVEPERSONSMAYSUFFERANEPILEPTICSHOCK!

www.elationlighting.com
FUZE PAR Z175™ User Manual
8
SAFETYINSTRUCTIONSANDGUIDELINES
DO NOT TOUCH the fixture housing during operation. Turn OFF the power and allow
approximately15minutesforthefixturetocooldownbeforeserving.
DONOTshakefixture,avoidbruteforcewheninstallingand/oroperatingfixture.
DONOToperatefixtureifthepowercordhasbecomefrayed,crimpedand/ordamaged.Ifthe
powercordisdamaged,replaceitimmediatelywithanewoneofsimilarpowerrating.
DO NOT block any air ventilation slots. All fan and air inlets must remain clean and never
blocked. Allow approx. 6” (15cm) between fixture and other devices or a wall for proper
cooling.
Wheninstallingfixturein a suspendedenvironment, alwaysuse mountinghardwarethatis no
lessthanM10x25mm,andalwaysinstallfixturewithanappropriatelyratedsafetycable.
Always disconnect fixture from main power source before performing any type of service
and/orcleaningprocedure.Onlyhandlethepowercordbytheplugend,neverpullouttheplug
bytuggingthewireportionofthecord.
Duringtheinitialoperationofthisfixture,alightsmokeor smellmayemitfromtheinteriorof
the fixture.This is a normalprocessandiscaused by excess paintin theinteriorofthe casing
burningofffromtheheatassociatedwiththelampandwilldecreasegraduallyovertime.
Consistent operational breaks will ensure the fixture will function properly for many years to
come.
Usetheoriginalpackagingandmaterialstotransportthe fixtureinforservice.
www.elationlighting.com
FUZE PAR Z175™ User Manual
9
OVERVIEW
1.LCDMenuDisplay
2.MENU,UP,DOWN,ENTERButtons
3.3pinDMXIN/OUT
4.5pinDMXIN/OUT
5.PowerIN
6.Fuse
7.powerOUT
www.elationlighting.com
FUZE PAR Z175™ User Manual
10
INSTALLATION
FLAMMABLE MATERIAL WARNING
Keep fixture at least 5.0 ft (1.5m) aw ay from any flammable
materials,decorations,pyrotechnics,etc.
ELECTRICAL CONNECTIONS
A qualified electrician should be used for all
electrical connections and/or installations.
CAUTIONS
For added protection, mount the fixture in areas outside walking paths, seating areas, or in
areaswhereunauthorizedpersonnelmightreachthefixture.
Ambientoperatingtemperaturerangeforthisfixtureisto113°F.(15°to45°C)
Donotusethefixtureunderorabovethistemperature.
Beforemountingthefixturetoanysurface,makesuretheinstallationareacanholdaminimum
pointloadof10timestheweightofthefixture.
Fixture installation must always be secured with a secondary safety attachment, such as an
appropriatesafetycable.
Neverstanddirectlybelowthedevicewhenmounting,removing,orservicing.
POWERLINKING
MaxnumberofFUZEPARZ175™unitspowerlinkedtogether:
5units@120V|10units@240V
NOTE:USECAUTIONWHENPOWERLINKINGOTHERFIXTURESTOFUZEPARZ175™!
POWERCONSUMPTIONOFOTHERLIGHTINGFIXTURESWILLVARY!
ALWAYSCHECKMAXAMPOUTRATINGPRINTEDONTHEREARCONNECTIONPANEL!

www.elationlighting.com
FUZE PAR Z175™ User Manual
11
CLAMPINSTALLATION
The fixture provides an integrated mounting dual bracket / yoke. When mounting this fixture to
trussbe suretosecureanappropriatelyratedclampto themountingbracket/ yokeusinga M10
screwfittedthroughthecenterhole.BesuretoattachanappropriateSafetyCable(notincluded)
tothefixtureusingthesafetycableriggingpointintegratedintothebackofthefixture.
RIGGING
Overheadriggingrequiresextensiveexperience,includingamongstotherscalculatingworkingload
limits,installationmaterialbeingused,andperiodicsafetyinspectionofallinstallationmaterialand
the fixture. If you lack these qualifications, do not attempt the installation yourself. Improper
installationcanresultinbodilyinjury.Fixture isfullyoperationalinthespecificmountingpositions
illustratedbelow.
SAFETY CABLE
ALWAYSATTACHASAFETYCABLETOTHE
FIXTUREWHENEVERINSTALLINGINA
SUSPENDEDENVIRONMENTTOENSURETHE
FIXTURE WILL NOT DROP IF
CLAMP FAILS
.
www.elationlighting.com
FUZE PAR Z175™ User Manual
12
FIXTUREMENU
The fixture comes with an easy to navigate system menu. The control panel (see image below)
located on the back of the fixture provides access to the main system menu and is where all
necessary system adjustments are made to the fixture. During normal operation, pressing MODE
buttononcewillaccessthefixture’smainmenu.Onceinthemainmenuyoucannavigatethrough
thedifferentfunctionsandaccessthesubmenuswiththeUPandDOWNbuttons.Onceyoureach
a field that requires adjusting, press the ENTER button to activate that field and use the UP and
DOWNbuttonstoadjustthefield.PressingtheENTERbuttononcemorewillconfirmyoursetting.
You may exit the main menu at any time without making any adjustments by pressing the
MODE/ESCbutton.
LCDCONTROLPANELLOCK OUT
WhentheKeyLock menu issettoON,theLCD displaywill turnOFFafter30 seconds andthe(4)
buttonControlPanelwillbe LOCKED.Tounlockthe(4)buttonLCDcontrolpanel,pressandholdthe
MODEbutton.
Red 000255
Green 000255
Blue 000255
White 000255
Zoom 000255
INFORMATIONDISPLAYEDDURINGINITIALPOWERON
Whenthefixtureis poweredON,thedisplayshowsthefollowinginformation:
Update
Wait...
ZOOM
Reset
ELATION
V102
FuzePar
Z175
FixtureSoftwareVersion
(Greaterthanorequalto)
www.elationlighting.com
FUZE PAR Z175™ User Manual
13
ELATION©FUZEPARZ175™
SYSTEM MENU
MENU OPTIONS/VALUES(DefaultSettingsinBOLD) DESCRIPTION
SetADDR 001~XXX DMXAddressSetting
UserMode
CH:04RGBW,CH05HSI,CH:05HSI+,CH:07RGBW,CH:08
sRGBWI,CH:08RGBW,CH:09RGBW,CH:10RGBW,CH:11
16Bit,CH:11HSI,13sRGBWI,CH:14RGBW
SetDMXChannel
Function
DimCurve
Standard,Stage,TV,Architectur,
Theatre
SetDimmerCurveMode
NoDMX Hold/Blackout/Program FunctionIfNODMXDetected
ZOOM 000‐255 ManualZoomControl
AUTORUN FQN:01‐99
Setthenumberoftimeseachinternal
macrowillrepeatbeforemovingtothe
nextmacro.
01.STATIC
CL:R
R/G/B/RG/GB/RB/RGB/BLAC
F00
SetSta ticColorPr ogramMacro
02.CHANG
SP01F00
SP0199F0099 SetColorChangeProgramMacro
03.FADE
SP01F00
SP0199F0099 SetColorFadeProgramMacro
Macros
0063 SelectColorMacro
Zoom:000‐255 SetZoom
LCD.Set
Backligh
0560
LCDBacklightShutOffTime(mins)
KeyLock
OFF/ON
ControlFrontPanelButtonsKeyLock
DispFlash
ON/OFF
DisplayflasheswhenNODMX
DFSE
T
OFF/ON ResetFixtureBackFactoryDefaults
TEMP Fahren/Celsius TemperatureSwitchBetweenCº/Fº
FANSE
T
Silent/Auto/High SetFan
Calibrat
Red 000255
Green 000255
Blue 000255
White 000255
Zoom 000255
Calibrate
LEDFreq 0.925KHz(1200Hz) LEDFrequency
Info
TimeInfo|Current XXXX(Hours) FixtureRunTimeFromPowerON
TimeInfo|TotalTim XXXX(Hours) FixtureTotalRunTime
TimeInfo|LastClea XXXX(Hours) ClearFixtureLastRunTime
TimeInfo|TimePIN PIN=050 EnterPINtoAccessClearLast.Menu
TempInfo XXX/ TemperatureinFixtureHead
ModelInf
FuzePar
Z175
DisplayFixtureModelName
SoftwareVersion
1UV106B
SoftwareVersions
(greaterthanorequalto)
2UV106B

www.elationlighting.com
FUZE PAR Z175™ User Manual
14
ELATION©FUZEPARZ175™
SYSTEM MENU
MENU OPTIONS/VALUES(DefaultSettingsinBOLD) DESCRIPTION
ZoomRset Reset.M SetDMXChannel
Secondary Secondry SetSecondaryMode
Manual
ManCtrl
ZOOM
000‐255
ManualControl
ManCtrl
Dimmer
000‐255
ManCtrl
Red
000‐255
ManCtrl
Green
000‐255
ManCtrl
Blue
000‐255
ManCtrl
White
000‐255
ManCtrl
Strobe
000‐255

www.elationlighting.com
FUZE PAR Z175™ User Manual
15
DIMMINGCURVES
The DimCurve menu allows you to select one of the following preset dimming curves: Standard,
Stage,TV,Architec,orTheatre.
www.elationlighting.com
FUZE PAR Z175™ User Manual
16
DMXCHANNELFUNCTIONSANDVALUES
ELATION©FUZEPARZ175™
DMXChannelValues/FunctionsVersion(15DMXChannels)
SupportsSoftwareVersions:≥1.06
Featuresaresubjecttochangewithoutanypriorwrittennotice
MODE/CHANNEL VALUE FUNCTION
4CH
RGBW
5CH
RGBW
5CH2
HSI
6CH
HIS+
7CH
RGBW
8CH
sRGBWI
8CH2
RGBW
8CH3
RGBW
9CH
RGBW
10CH
RGBW
10CH2
RGBW
11CH
RGBW
11CH2
16bit
11CH3
HSI
12CH
16bIT
13CH
sRGBWI
14CH
RGBW
15CH
RGBW

1 1 1 2 1 1 1 1 1 1 11 2 1 1 0255
Red
0100%
  22 0255
RedFine
0100%
2 2 2 3 2 2 2 2 2 2 33 3 2 2 0255
Green
0100%
  44 0255
GreenFine
0100%
3 3 3 4 3 3 3 3 3 3 55 4 3 3 0255
Blue
0100%
  66 0255
BlueFine
0100%
4 4 4 5 4 4 4 4 4 4 77 5 4 4 0255
White
0100%
  88 0255
WhiteFine
0100%
1 5 5 5 5 11 6 6 0255 Strobe
1 1  20255
Hue
0100%
2 2  3 10255
Saturation
0100%
55 5 6 6 6 6 7 7 0255
Dimmer
0100%
 67 7 7 7 8 8 0255
DimmerFine
0‐100%
3 3 6 46 Intensity
  57 5 5 Macros
4 4 6 7 7 6 8 8 8 8 9 6 9 8 9 9 Zoom
  1010 ZoomFine
  79 10 10
0
0120
2140
4160
6180
81100
101120
121140
141160
161180
181200
201220
221240
241250
251255
AutoPrograms
Off
AutoProgram1
AutoProgram2
AutoProgram3
AutoProgram4
AutoProgram5
AutoProgram6
AutoProgram7
AutoProgram8
AutoProgram9
AutoProgram10
AutoProgram11
AutoProgram12
AutoProgram13
Fade
  810 11 11 0255 Programs Speed
  911 12 12 0255 Programs Fade
5 991012 13 13 DimmerCurve
5 6 7 8 8 7 9 10 9 10 11 11 11 13 14 14
079
8084
85255
Special
Normal
ZoomReset
NoFunction

www.elationlighting.com
FUZE PAR Z175™ User Manual
17
ELATION©FUZEPARZ175™
DMXChannelValues/FunctionsVersion(15DMXChannels)
SupportsSoftwareVersions:≥1.06
Featuresaresubjecttochangewithoutanypriorwrittennotice
MODE/CHANNEL VALUE FUNCTION
5 8 10 11 12 15
03
46
79
1012
1315
1618
1921
2224
2527
2830
3133
3436
3739
4042
4345
4648
4951
5254
5557
5860
6163
6466
6769
7072
7375
7678
7981
8284
8587
8890
9193
9496
9799
100102
103105
106108
109111
112114
115117
118120
121123
124126
127129
128130
131133
134136
137139
140
142
143145
146148
149151
152154
155157
158160
161163
164166
167169
170172
173175
NoFunction
1200Hz
900Hz
910Hz
920Hz
930Hz
940Hz
950Hz
960Hz
970Hz
980Hz
990Hz
1000Hz
1010
Hz
1020Hz
1030Hz
1040Hz
1050Hz
1060Hz
1070Hz
1080Hz
1090Hz
1100Hz
1110Hz
1120Hz
1130Hz
1140Hz
1150Hz
1160Hz
1170Hz
1180Hz
1190Hz
1210Hz
1220Hz
1230Hz
1240Hz
1250Hz
1260Hz
1270Hz
1280Hz
1290Hz
1300Hz
1310Hz
1320Hz
1330Hz
1340Hz
1350Hz
1360Hz
1370Hz
1380Hz
1390Hz
1400Hz
1410Hz
1420Hz
1430Hz
1440Hz
1450Hz
1460Hz
1470Hz

www.elationlighting.com
FUZE PAR Z175™ User Manual
18
ELATION©FUZEPARZ175™
DMXChannelValues/FunctionsVersion(15DMXChannels)
SupportsSoftwareVersions:≥1.06
Featuresaresubjecttochangewithoutanypriorwrittennotice
MODE/CHANNEL VALUE FUNCTION
5 8 10 11 12 15
176178
179181
182184
185187
188190
191193
194196
197199
200202
203205
206208
209255
1480Hz
1490Hz
1500Hz
2500Hz
4000Hz
5000Hz
6000Hz
10,000Hz
15,000Hz
20,000Hz
25,000Hz
NoFunction

www.elationlighting.com
FUZE PAR Z175™ User Manual
19
CLEANINGANDMAINTENANCE
CAUTION
Disconnectpowerbeforecleaningormaintenance.
CLEANING
Frequent cleaning is recommended to insure proper function, optimized light output, and an
extendedlife.Thefrequencyofcleaningdependsontheenvironmentinwhichthefixtureoperates:
damp, smoky or particularly dirty environments can cause greater accumulation of dirt on the
fixture’soptics.
Clean the external lens surface at least every 20 days with a soft cloth to avoid dirt/debris
accumulation.
Neverusealcohol,solvents,orammoniabasedcleaners.
MAINTENANCE
Regularinspectionsarerecommendedtoinsureproperfunctionandextendedlife.
There are no user serviceable parts inside this fixture, please refer all other service issues to an
authorizedElationservicetechnician.Shouldyouneedany spareparts,pleaseordergenuineparts
fromyourlocalElationdealer.
Pleaserefertothefollowingpointsduringroutineinspections:
Adetailedelectriccheckbyanapprovedelectricalengineer everythreemonths,tomakesurethe
circuitcontactsareingoodconditionandpreventoverheating.
Besureallscrewsandfastenersaresecurelytightenedatalltimes.Losescrewsmayfalloutduring
normaloperationresultin gindamageorinjuryaslarger partscouldfall.
Check for any deformations on the housing, color lenses, rigging hardware and rigging points
(ceiling, suspension, trussing). Deformations in the housing could allow for dust to enter into
the fixture. Damaged rigging points or unsecured rigging could cause the fixture to fall and
seriouslyinjureaperson(s).
Electricpowersupplycablesmustnotshowanydamage,materialfatigueorsediments.Never
removethegroundprongfromthepowercable.
www.elationlighting.com
FUZE PAR Z175™ User Manual
20
TECHNICAL SPECIFICATIONS
SOURCE
175WRGBWCOBLED
50,000HourAverageLEDLife*
*Mayvarydependingonseveralfactorsincludingbutnotlimitedto:
EnvironmentalConditions,Power/Voltage,UsagePatterns(OnOffCycling),Control,andDimming.
EFFECTS
‐35°MotorizedZoom
ElectronicStrobe
ColorandChaseMacros
ElectronicDimming:0%‐100%
16bitDimmingandVariableDimmingCurveModes
CONTROL/CONNECTIONS
(12)DMXChannelModes(14TotalChannels)
(4)ButtonTouchControlPanel
LCDMenuDisplay
3pin/5pinDMXIn/Out
powerCONIn/Out
SIZE/WEIGHT(withbarndoorsattached)
Length:18.2”(463mm)
Width:16.2”(411mm)
VerticalHeight:17.0”(431mm)
Weight:20.0lbs.(9.07kg)
ELECTRICAL/THERMAL
AC100250V‐50/60Hz
220WMaxPowerConsumption
5°Fto113°F(15°Cto45°C)
APPROVALS/RATINGS
CE|IP30
PleaseNote:Specificationsandimprovementsinthedesignofthisunitandthismanualaresubjecttochangewithoutanypriorwrittennotice.

/