Newland FM420 Quick start guide

Category
Bar code readers
Type
Quick start guide

Newland FM420 is a versatile barcode scanner equipped with advanced imaging technology, allowing you to capture 1D and 2D barcodes with ease. It features multiple connectivity options, including USB and RS232, providing flexible integration with various systems. The user-friendly design, with intuitive indicators and a compact form factor, makes it suitable for both retail and industrial environments.

Newland FM420 is a versatile barcode scanner equipped with advanced imaging technology, allowing you to capture 1D and 2D barcodes with ease. It features multiple connectivity options, including USB and RS232, providing flexible integration with various systems. The user-friendly design, with intuitive indicators and a compact form factor, makes it suitable for both retail and industrial environments.

V1.0
FM420
Fixed Mount Barcode Scanner
Quick Start
Version Description Date
V 1.0 Support as from FM420 rmware V 3.06.021 and
higher. 19-10-2010
Revisions
Getting to Start
Unpacking.......................................... E-01
Main Unit........................................... E-01
Accessories ........................................ E-02
Outline and Function ......................... E-03
Data Interface Denition ................... E-04
Specication ...................................... E-05
Distance of Field................................ E-06
Dimentions of FM420 Unit ............... E-07
Connect FM420 to the Host .............. E-08
Programming Code
Query ................................................ E-09
Factory Default .................................. E-10
Reading Mode ................................... E-11
RS232 Programming ......................... E-12
USB Programming ............................ E-15
USB HID-KBW Programming .......... E-16
Beeper ................................................ E-19
Line Feed and Carriage Return.......... E-20
1D Symbols ....................................... E-21
2D Symbols ....................................... E-26
Appendix
A. Testing Codes................................ E-28
B. Digit Code and Save ..................... E-29
C. Troubleshooting ............................ E-30
Content
E-01
请更换节标题
Getting to Start
FM420 »
Unpacking
Unpack and check the main unit and accessories.In case there is any problem, please
contact with your dealer.
Main Unit
E-02
Getting to Start
Accessories
USB Cable »
Accessories
RS232 Cable + Power Adapter »
E-03
Getting to Start
Outline and Function
Indicator
Sensor Light
Illumination/Aiming Light
Lens
Note:
The scan window must be kept clean. Improper maintenance will breach the »
limited warranty.
Avoid rough objects not to damage or scratch the window.
»
Use brush to remove the stain. »
Use soft cloth (cloth for glasses) to clean. »
Prohibit spraying towards the window. »
Only use clean water as a cleanser. »
E-04
Getting to Start
Data Interface Denition
PIN 1
PIN 10
Cable Slot
Pin Function Type Name
1 NC Null
2 NC Null
3 VCC P Power DC5V
4 TXD O Serial Port OutputRS232
5 RXD I Serial Port InputRS232
6 NC Null
7 NC Null
8 GND P Ground
9 D- IO USB Data Signal
10 D+ IO
E-05
Getting to Start
Specication
Pin Function Type Name
1 NC Null
2 NC Null
3 VCC P Power DC5V
4 TXD O Serial Port OutputRS232
5 RXD I Serial Port InputRS232
6 NC Null
7 NC Null
8 GND P Ground
9 D- IO USB Data Signal
10 D+ IO
Image Capture Specications
Image Sensor CMOS
Resolution 752*480
Interface RS232, USB
Barcode Scan Specications
Symbols
2D PDF417, QR Code(Model 1/2), DataMatrix(ECC200, ECC000, 050,
080, 100,140),Aztec, Maxicode, etc.
1D Code128, EAN-13, EAN-8, Code39, UPC-A, UPC-E, Codabar,
Interleaved 2 of 5, ISBN, Code 93, UCC/EAN-128, GS1 Databar, etc
Precision 5mil
Depth of Scan Field 35mm-210mm
Print Contrast Ratio 30%
Sensitivity**
Roll 360°@ 0°Pitch and 0° Skew
Yaw (skew) ±60°@ 0°Roll and 0° Pitch
Pitch ±60°@ 0°Roll and 0° Skew
Illumination Specications
Light Source LED (622 nm - 628 nm)
Light Intensity 330 LUX (130 mm )
Electrical and Mechanical Specications
Power Consumption 2W
Voltage DC 5V (4.5-5.5)
Current
Working 400mA
Idle 78mA
Standby 18mA
Deep Sleep 800uA
Dimensions(L*W*H) 60.0 *50.0*26.0mm
Weight 70g
Environment Specications
Operating Temperature -5 - +45
Storage Temperature -40 - +60
Humidity 5% - 95% (non-condensing)
Ambient Illumination 0 ~ 100,000 LUX
Certicates
FCC Part15 Class B, CE EMC Class B
**Test Condition:
Code39: 4 Bytes ; Resolution = 10mil; W:N = 3:1 ; PCS = 1.0 ;
Barcode Height = 12mm; Distance = 100mm; T=23°C; Illumination= 200 LUX
E-06
Getting to Start
Distance of Field
36°
0 50 100 150 200 250
55mm PDF417(10mil) 175mm
45mm Data Matrix(10mil 145mm
45mm QR Code(10mil 140mm
35mm Code39(10mil) 170mm
55mm Code39(15mil) 210mm
45mm Data Matrix(15mil 175mm
60mm PDF417(15mil) 205mm
50mm QR Code(15mil 175mm
E-07
Getting to Start
Dimentions of FM420 Unit
50mm
60mm
26mm
12mm 10mm
9mm
36mm
11 7mm.
M3 machine skew
E-08
Getting to Start
Connect FM420 to the Host
Connecting with USB Cable
Insert USB Cable (RJ45 male head) into 1
FM420 cable slot;
Insert USB Cable (USB male head) into 2
Hosts (female) USB connector;
Connecting with RS232 Cable
Insert RS232 cable (RJ45 male head) into 1
FM420 cable slot;
Insert RS232 cable (RS232 male head) 2
into Hosts (female) RS232 connector;
Connect RS232 cable and the mains with 3
power adapter;
E-09
请更换节标题
Programming Code
Code Programming ON
Code Programming OFF
Query
Send Product Info, the engine sends product information to the
Host immediately.Send Sys Info when Power ON, the engine sends
product information through RS232(only) to the Host after Power ON.
The system information is provided as follows:
Title Remarks
Firmware Ver Device Firmware Version
Build Time Device Firmware Version Establishing Time
Device ID Device Type
App Ver Device Application Version
uIMG Ver Device uIMG Version
Date Device Manufacture Date
S/N Device serial number
ESN User-defined device serial number
Manufacture ID Device Name
Interface 1 types of communication interfaces:
RS232, baud rate, parity check, data bits, stop bit
1D Indicate that reading 1D is allowed.
2D Indicate that reading 2D is allowed.
Scan Mode Auto Scan
Send Product Info
Send Sys Info when Power ON Do not Send Product Info when Power ON
(Factory Default)
E-10
Programming Code
Code Programming ON
Code Programming OFF
Factory Default
Part of Factory Default
Subject Factory Default
Interface
RS232 and USB Self-adaption The default value is as below
RS232Baud Rate: 9600bit/s,Parity Check:No Check,Data / Stop
Bit:8 bits/1 bit); USB(HID-KBW)
Beep On
Scan Mode Auto Mode
1D 1D SymbolsEnable
Code128, EAN-13, EAN-8, Code39, UPC-A, UPC-E, Codabar,
China post 25,Interleaved 2 of 5, ISBN/ISSN, Code 93, GS1
Databar, Code 11,etc
2D 1D SymbolsEnablePDF417, QR Code(Model 1/2), DataMatrix (ECC200, ECC000,
050, 080,100,140), Aztec, Maxicode, LP Code, etc.
Load All Factory Default
E-11
Programming Code
Code Programming ON
Code Programming OFF
Reading Mode
Auto Mode: The ambient luminance change in front of the »
engine automatically initiates reading. After completion of reading,
the engine goes to idle. Both luminance change and the Trigger can
initiate reading when idle.
Auto Mode
(Factory Default)
E-12
Code Programming ON
Code Programming OFF
Programming Code
RS232 Programming
Baud Rate
Under RS232 connection, the engine and the Host should set
communication baud rate to the same to keep normal communication.
Baud rate is the bits transmitted per second (8 bits per bytes). The engine
and the Host must communicate at the same baud rate.
The scanner supports baud rate as the following:
9600
Factory Default
2400
14400
38400
115200
1200
4800
19200
57600
E-13
Programming Code
Code Programming ON
Code Programming OFF
RS232 Programming
Parity Check
NO Check
(Factory Default)
Even Check
Odd Check
1 Stop Bit
(Factory Default)
2 Stop Bits
Stop Bits
E-14
Programming Code
Code Programming ON
Code Programming OFF
RS232 Programming
Data Bits Transmitted
8 Data Bits
(Factory Default)
7 Data Bits
6 Data Bits
5 Data Bits
E-15
Programming Code
Code Programming ON
Code Programming OFF
USB Programming
Select USB HID-KBW
Select USB DataPipe
Select USB COM Port Emulation
Select USB HID-POS
Note A driver has to be installed before using USB DataPipe and USB COM Port Emulation.
E-16
Programming Code
Code Programming ON
Code Programming OFF
USB HID-KBW Programming
The keyboard arrangements and country codes vary in different
countries. Refer country codes to the table USB Country Keyboard
Types. Follow the steps mentioned below to program.
1.Code Programming ON
2.Select Country Code
3. Read digit codes (See country code and appendix for digit
code)
4.Save
5.Code Programming OFF
Select Country Code
Keyboard Coutry
Country/Language Code Country/Language Code
U.S.(Factory Default) 0 Netherlands(Dutch) 14
Belgium 1 Norway 15
Brazil 2 Poland 16
Canada(French) 3 Portugal 17
Czechoslovakia 4 Romania 18
Denmark 5 Russia 19
Finland(Swedish) 6 Slovakia 21
France 7 Spain 22
Germany/Austria 8 Sweden 23
Greece 9 Switzerland(German) 24
Hungary 10 Turkey F 25
Israel(Hebrew) 11 Turkey Q 26
Italy 12 U.K 27
Latin-American 13 Japan 28
Country Code
E-17
Programming Code
Code Programming ON
Code Programming OFF
USB HID-KBW Programming
Keystroke Delay
This parameter sets the delay, in milliseconds, between emulated key-
strokes. Scan programming code below to increase the delay when the Host
require a slower transmission of data.
Short Delay(Continuous keystroke
Factory Default)
Medium Delay(20ms)
Long Delay(40ms)
Caps Lock Override
The case of the data is inverted regardless of the state of the Caps Lock key on the Host. Lower
case and upper case are converted correspondingly.
No Caps Lock Override
(Factory Default)
Caps Lock Override
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34

Newland FM420 Quick start guide

Category
Bar code readers
Type
Quick start guide

Newland FM420 is a versatile barcode scanner equipped with advanced imaging technology, allowing you to capture 1D and 2D barcodes with ease. It features multiple connectivity options, including USB and RS232, providing flexible integration with various systems. The user-friendly design, with intuitive indicators and a compact form factor, makes it suitable for both retail and industrial environments.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI