CyberData 011416 Owner's manual

Type
Owner's manual
Quick Reference 931352B © 2020, CyberData Corporation, ALL RIGHTS RESERVED© 2020, CyberData Corporation, ALL RIGHTS RESERVED 931352B Quick Reference
Getting Started
Take the following into consideration before you install this product:
When this secure phone case is used, the touch screen capability of the DX phone is disabled.
Due to the size and mass of this product, it is important that the Backbox is safely installed according to these installation
instructions.
Make sure that the type of wall is capable of supporting the system and use screws that are suitable for that type of wall.
The system must be installed by qualified personnel in accordance with state and local building regulations.
Also see the Install the DX80 Phone to Enclosure (on the other page).
Locate the provided Security Torx Driver Bit (usually taped right next to the Hookswitch on the Faceplate).
Tool required to remove Security Torx Screws (an Electric Hand Drill or Powered Screwdriver)
WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation
instructions.
WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.
WARNING: This enclosure is not rated for any AC voltages!
Hookswitch Wires to USB to Analog Audio Module Connections
Contacting CyberData
USB - B Plug
on DX80
USB - A to B Cable
10
8
7
6
4
3
2
Plug in to Connector Panel
Plug in to (J1)
USB - A Plug
1
J4
J1
FACTORY DISCONNECTED
RE-CONNECT BEFORE FASTEN
FACEPLATE TO BACKBOX
***
ASSEMBLY
HOOKSWITCH
9
5
WIRES TO SOCKET
SOCKET
PLUG
FACTORY PRE-INSTALLED
WIRES TO SOCKET
Sales: 831-373-2601 ext. 334
Support: 831-373-2601 ext. 333
Support Website: http://support.cyberdata.net/
RMA Department: 831-373-2601 ext. 136
RMA Status: http://support.cyberdata.net/
Warranty Information: http://support.cyberdata.net/
Corporate Headquarters
CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA
Phone: 831-373-2601
Fax: 831-373-4193
http://www.cyberdata.net/
Backbox Mounting
Armored Cord Handset to USB to Analog Audio Module
Tool Required for Knock Out Removal:
1) Hammer
2) Blade Screwdriver
One Inch EMT Fitting
Knock Out
Conduit Hole Fits
Knock Out
Knock Out
Knock Out
Ø0.63 [Ø16.0]
Ø0.41 [Ø10.5]
Ø0.41 [Ø10.5]
Ø1.30 [Ø33.0]
View Shown with Hole Plug Installed.
Open Faceplate then Remove Nut from the Inside.
1/4"- 20 Thread Size
Keyholes & Holes Fits Up to
Stud Anchor/Screw/Bolt
(Optional) SPAR II - RTFM Access Hole
with Handsfree Kit (P/N: 081136A)
Replaceable Coverplate
(Sold Separate) for Handsfree Operation
T15H Security Torx Screw Installed from the Inside
1.969 [50.00]
5.118 [130.00]
5.118 [130.00]
2.047 [52.00]
4.016 [102.00]
1.969 [50.00]
19.685 [500.00]
9.843 [250.00]
3.602 [91.50]
3.602 [91.50]
15.748 [400.00]
4.016 [102.00]
9.114 [231.50]
3.937 [100.00]
12.567 [319.19]
13.780 [350.00]
9.114 [231.50]
Electro-Galvanized Steel Constructed Backbox with
1.6 mm Thick
Silver Hammertone Polyester PowderCoat
11/32" or 9mm Socket & Socket Wrench
Tool Required to Remove Hole Plug:
Last Updated 08/04/2020
Red Wire to J4 (Position 1)
Green Wire to J4 (Position 3)
Black Wire to J4 (Position 4)
Yellow Wire to J4 (Position 2)
J4
1) #00 size Phillips Screw Driver
Tool Provided for Terminal Block Screw:
Armored Cord Wires End
6
7
5
8
9
10
4
3
2
1
The IP Endpoint Company
Installation Quick Reference
DX80 Secure Phone
011416
Quick Reference 931352B © 2020, CyberData Corporation, ALL RIGHTS RESERVED© 2020, CyberData Corporation, ALL RIGHTS RESERVED 931352B Quick Reference
© 2020, CyberData Corporation, ALL RIGHTS RESERVED 931352B Quick Reference Quick Reference 931352B © 2020, CyberData Corporation, ALL RIGHTS RESERVED
Install the DX80 Phone to Enclosure
Connections
Label
2) Screw Driver
1) Hammer
Tool Required to Remove Knock Outs (KO):
3) Plier
KO
1/4" Self-Tapping Screw
Up to 1/4" Square Neck Carriage Bolt
Knock Outs (KO) & Keyhole Fit:
or 10 Millimeter Machine Screw
KO
KO
KO
KO
KO
Use Provided Security Torx
Driver Bit to Fasten Screws
Place Phone
Power Supply
inside Holder
Use Clean Damp Cloth to Wipe Surface Clean
Screen Cleaning Instruction:
Plexiglass Cleaning Instruction:
Plexiglass Cleaner to Wipe Surface Clean
ASSEMBLY
FACEPLATE
ASSEMBLY
BACKBOX
Phone Mounting Instruction:
Plug Power Plug
in to Power Jack
on the Connector Panel
to Backbox
To Remove Phone from Backbox:
See Hookswitch to
USB to Analog Audio Module Diagram
for Detail Connections
IEC Power Cord
the Other Through Any Available
Conduit Hole Exit to Power Source
Fits Size #8 or M4 Ring Terminal
Connector Cover
Turn to Open Lens Cover
Sightly Push Downward to Engage Locking
5) Place Strain Relief Bar on Top of CLAMP
Camera
Holder
on DX80 Phone
Foot Stand
CLAMP
Strain Relief Bar
1) Lift Connector Cover Up
Plate
3) Place Foot Stand Behind Plate
4) Place Microphone on to Stand
Microphone
Microphone
Stand
Stand
Use a Paper Clip Through Hole
to Access Power Button
Camera
2) Plug in All Neccessary Cables,
Cables Must be Placed Behind Strain Relief Bar
Front
Behind
1) Lift Phone Up in Slow Motion then Disconnect
All Cable from Connector Panel
CLAMP
Ground Lug
Torx Sec. Bit & Spare Screw Kit
#6-32x5/8"Flat Head
Pin Torx Machine Screw
(Spare - 2 Pieces)
Cable Management Kit
T-15 Pin Torx
6" Wire Tie (2x)
Wire Tie Mounting
1.5" Square
Base (2x)
Accessory Kit
#00 Screw Driver Kit
Cable Management Kit
#8 Hex Nut
Security Driver Bit
#6-32 x 3/16”
Button Head Torx
Machine Screw
(Spare)
(GND Lug)
Jumper Shunt
1/16” Hex L-Key
Acrylic Bezel Remove Kit
Acrylite AR - Anti-Scratch
Resistance Coating on the Outside
JP2
Shunt
Install a Shunt on JP2 to
Enable Auto Answer Mode
  • Page 1 1
  • Page 2 2
  • Page 3 3

CyberData 011416 Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI