LED IMPORTANT SAFETY INSTRUCTIONS
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and
other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
Installation and service of luminaires should be performed by a qualified licensed electrician.
Maintenance of the luminaires should be performed by person(s) familiar with the luminairesconstruction and operation
and any hazards involved. Regular fixture maintenance programs are recommended.
It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient
dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm
water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly
become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been
damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency
to meet in connection with installation, operation, or maintenance. Should further information be desired or should
particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be
referred to Acuity Brands Lighting, Inc.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
Disconnect or turn off power before
installation or servicing.
Verify that supply voltage is correct by
comparing it with the luminaire label
information.
Make all electrical and grounded
connections in accordance with the National
Electrical Code (NEC) and any applicable
local code requirements.
All wiring connections should be capped
with UL approved recognized wire
connectors.
WARNING
RISK OF ELECTRIC SHOCK
Allow lamp/fixture to cool before handling.
Do not touch enclosure or light source.
Do not exceed maximum wattage marked on
luminaire label.
Follow all manufacturer’s warnings,
recommendations and restrictions for: driver
type, burning position, mounting
locations/methods, replacement and
recycling.
WARNING
RISK OF BURN
Wear gloves and safety glasses at all times
when removing luminaire from carton,
installing, servicing or performing
maintenance.
Avoid direct eye exposure to the light source
while it is on.
CAUTION
RISK OF INJURY
Keep combustible and other materials that
can burn, away from lamp/lens.
Do not operate in close proximity to persons,
combustible materials or substances
affected by heat or drying.
CAUTION
RISK OF FIRE
DISCONTINUED
IM-396
Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory
statements.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and
Conditions, please visit www.acuitybrands.com.
Our Brands Indoor/Outdoor Indoor Lighting Outdoor Lighting Controls
Lithonia Lighting Gotham American Electric Lighting DARK TO LIGHT
Carandini Mark Architectural Lighting Antique Street Lamps Lighting Control & Design
Holophane Peerless Hydrel ROAM
RELOC Renaissance Lighting Tersen Sensor Switch
Winona Lighting Synergy
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2011 Acuity Brands Lighting, Inc. All rights reserved. 04/18/11
Never connect components under load.
Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire
insulation.
Unless individual product specifications deem otherwise: Never connect an LED product directly to a
dimmer packs, occupancy sensors, timing devices, or other related control devices. LED fixtures must be
powered directly off a switched circuit.
Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for
some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other
material that will prevent convection or conduction cooling.
Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient
temperature.
Only use fixture in its intended location.
LED products are Polarity Sensitive. Ensure proper Polarity before installation.
Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be
worn during all installation or servicing of the unit.
Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter
performance.
Some components inside the fixture may not be serviceable. In the unlikely event your unit may require
service, stop using the unit immediately and contact an ABL representative for assistance.
Always read the fixtures complete installation instructions prior to installation for any additional fixture
specific warnings.
CAUTION: RISK OF PRODUCT DAMAGE
DISCONTINUED
HOLOPHANE® Installation and
Tear Drop Utility LED Luminaire Series Maintenance
(ESL3 & MPL3) Manual
IM-396
AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER
GR2419
IMPORTANT SAFETY INSTRUCTIONS
WARNING READ THESE INSTRUCTIONS
CAREFULLY BEFORE ATTEMPTING TO INSTALL OR
MAINTAIN THIS FIXTURE. WORK MUST BE DONE BY
QUALIFIED PERSONNEL.
WARNINGBE CERTAIN THAT ALL ELECTRICAL
POWER IS DISCONNECTED FROM THE FIXTURE
BEFORE INSTALLING OR MAINTAINING THE FIXTURE.
WARNINGFOLLOW LAMP MANUFACTURER’S
OPERATING AND MAINTENANCE INSTRUCTIONS.
FAILURE TO FOLLOW THESE WARNINGS
MAY RESULT IN DEATH, INJURY OR SIGNIFICANT
PROPERTY DAMAGE.
1 INTRODUCTION
1.1 Product Description.
This fixture is designed to operate an LED light source at up to
245 watts.
This fixture must be serviced by trained electrical personnel.
This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept
any interference received, including interference that may
cause undesired operation.
1.2 Alternate Information Sources.
Holophane
Field Service Department
P.O. Box 3004
Newark, OH 43058-3004
(740) 349-4182
ESL3
MPL3
DISCONTINUED
IM-396
2 INSTALLATION
2.1 Tools and Materials Required
DESCRIPTION USE
Flat blade screwdriver Terminal block connections
Pendant Mount:
3/16” Allen wrench Setscrew
Pipe Thread Sealant Mounting pipe threads
Stem Mount:
1/8" Allen wrench Setscrew
3/16” Allen wrench Setscrew
1/4” Allen wrench Setscrew
9/16” Socket Nuts
3/8” Socket Screws
2.2 Fixture Installation.
2.2.1 Remove the mounting assembly from the electrical housing
by releasing the latch and then swinging it open until the hinge
disengages. See Figure 1.
2.2.2 Loosen the wire chamber cover screws and remove the
wiring chamber cover. Allow it to hang by the electrical wires
attached to the terminal block. See Figure 1.
Figure 1
GR1492
2.2.3 Pendant mount
This unit must be mounted to a 1-1/2 NPT male threaded pendant.
Verify that the set screw, located in the mounting assembly, is
backed out enough that it will not interfere with the mounting
threads. See Figure 1. Thoroughly inspect threads for damage.
DO NOT attempt to assemble with another part if any thread
damage is found on either part. Apply pipe thread sealant
completely around the first 4 male threads on the mounting
pendant. Force the sealant into the threads, see Figure 2.
Thread the mounting assembly onto the pipe threads. Tighten by
hand at least 5 full turns to ensure the end of the conduit goes past
the setscrew hole.
Figure 2
GR1060
CAUTION
FIELD APPLICATION OF PIPE THREAD SEALANT IS
REQUIRED. FAILURE TO PROPERLY APPLY PIPE THREAD
SEALANT COULD CAUSE THIS UNIT TO LEAK OR CAUSE
INADEQUATE THREAD ENGAGEMENT.
PIPE THREAD SEALANT MUST BE APPLIED TO MALE
THREAD ASSEMBLY TO ENSURE PROPER INSTALLATION
2.2.4 Rigid Pendant mounting - Thread the mounting assembly
onto the pipe threads. Tighten by hand at least 5 full turns to insure
the end of the conduit goes past the setscrew hole. Continue to
tighten with wrench until the threads tighten completely and the
street side of luminaire is pointed in proper direction. Reflector
assembly and refractor are marked "street side."
2.2.5 Tighten the set screw to 12-15 ft-lbs.
2.2.6 Quick Stem Mount
Refer to Installation Manual provided with the swivel fitter (IM-347)
Attach the luminaire to the fitter by removing fitter door and inserting
stem of luminaire into the fitter. (Fig 3) Do not damage the electrical
supply wires during attachment of the luminaire. Feed the electrical
supply wires through the center of the stem grommet and make final
connection per section 2.2.7. Replace the fitter door by engaging
the lip of the door inside the fitter. Tighten the door screws to 5-6 Ft-
lbs. Tighten the nuts on the U-bolts to 30-40 Ft-lbs. Allow luminaire
to self-level and tighten the set screws to 12-15 Ft-lbs. If necessary,
adjust the leveling set screws so that the fitter is installed level.
Install shaft collar on stem in upmost position, flush with fitter.
Figure 3
GR2185
DISCONTINUED
IM-396
2.2.7 Remove wire chamber cover and connect the electrical
supply wires to the terminal block in the back of the electrical
chamber. The terminals are marked "L1" (Line 1). "G" (Ground),
and "L2" (Line 2). If one of the supply lines is electrically neutral, it
should be connected to terminal "L2". (Fig 1) Replace wire
chamber cover.
2.2.8 DM Option For units equipped with 0-10V dimming,
locate the gray and purple leads from the driver module. These are
to be used with a Holophane approved control circuit.
CAUTION
LEADS USED FOR DIMMING CONTROLS ARE TO BE
SEPARATED FROM MAIN POWER CONDUCTORS IN A
MANNER TO SATISFY STATE AND LOCAL CODES.
2.2.9 Hang the electrical assembly on the mounting assembly
hinge and plug in the electrical connector. See Figure 4.
If equipped with a photocontrol receptacle, insert photocell and
position eye towards lens. Swing the electrical assembly closed
and engage the latch to the catch to securely close unit.
2.2.10 Hang the refractor assembly on the door hinge. Swing the
refractor assembly closed, engage the closure bolt and tighten the
wing nut securely. See Figure 5.
2.2.11 If using Flat Glass (FG) Option, REMOVE BLUE FILM
FROM GLASS.
OPTICS ORIENTATION NOTE
The product has a molded-in “STREET SIDE” marking. Insure that
this side is aimed toward the street.
2.2.11 Electrically energize the fixture and check for proper
operation.
Figure 4
GR 2420
Figure 5
GR396
3 MAINTENANCE
3.1 Relamping and Cleaning.
3.1.1 Wipe off exterior dirt and debris.
3.1.2 Loosen the wing nut securing the refractor assembly and
disengage the closure bolt, swinging the refractor open slowly. See
Figure 5.
3.1.3 Inspect the LED board and reflector assembly. These are
maintenance free items and should never be touched, adjusted or
wiped with any cleaner.
3.1.4 Wipe off the refractor and reflector with a dry cloth. If the
refractor needs to be washed, use water and detergent.
CAUTION
DO NOT USE ABRASIVE CLEANSERS ON OPTICAL SURFACES.
THEIR USE MAY RESULT IN THE LOSS OF OPTICAL
PERFORMANCE.
3.1.5 Swing the refractor assembly closed, engage the closure bolt
and tighten the wing nut securely. See Figure 5.
3.2 Electrical Component Replacement.
NOTE
The entire fixture below the mounting assembly (Fig 1.) may be
removed in the field to allow further maintenance of the module to
be performed in the shop.
The fixture contains a surge protection module (Shown in Fig 4) that
is meant to fail in case of electrical spikes or over voltage
conditions. Remove this and replace to see if this restores power to
the circuit.
3.2.1 Disengage the latch securing the fixture to the mounting
assembly and swing the fixture open slowly.
3.2.2 Disconnect the electrical connector and then remove the
fixture from the mounting assembly by swinging the fixture open on
the hinge far enough to disengage the hinge pin from the hinge
hook. See Figure 1.
3.2.3 Remove the electrical module by loosening the two
attachment screws and disengaging the module from the screw
heads and lift the module from the electrical housing. See Figure 1.
3.2.4 Carefully note the position and attachment means for all
components and wiring and tag all wiring that will be disconnected.
Remove the screws, straps and brackets securing the component(s)
and save all mounting hardware for reuse.
DISCONTINUED
IM-396
3.2.5 Replace with Holophane supplied electrical components,
positioning the new component exactly as was the old. Secure with
the original hardware and tighten all fasteners securely.
3.2.6 Rewire based on the tags applied earlier and according to
industry accepted wiring techniques. Reposition all wiring and
secure it as it was originally.
3.2.7 Carefully reinstall the electrical module into the electrical
housing; tighten all screws securely. See Figure 4.
3.2.8 Hang the fixture on the hinge hook of the mounting
assembly and plug in the electrical connector. Swing the electrical
assembly closed and engage the latch to the catch to securely
close unit. See Figure 1.
3.2.9 Electrically energize the fixture and check for proper
operation.
4 Limited Warranty and Limitation of Liability
The Holophane limited warranty and limitation of liability is
published in the "Terms and Conditions" section of the current
Holophane buyer's guide, and is available from your local
Holophane sales representative.
4.1 Failure to properly install this Unit will void all warranties.
5. LIMITED WARRANTY AND
LIMITATION OF LIABILITY
Complete warranty terms located at: www.acuitybrands.com/
support/warranty/terms-and-conditions
6. ADJUSTABLE OUTPUT (AO) TABLES
Field Adjustable Output Module
The Field Adjustable Output (AO) module is an onboard device
that adjusts the light output and input wattage to meet site specific
requirements, allowing a single fixture configuration to be flexibly
applied in many different applications.
P10S: MVOLT and HVOLT
AO Position
% Lumens
% Wattage
8
100%
100%
7
94%
94%
6
80%
80%
5
68%
68%
4
55%
55%
3
41%
42%
2
28%
29%
1
37%
41%
P15S: MVOLT and HVOLT
AO Position
% Lumens
% Wattage
8
100%
100%
7
94%
94%
6
80%
80%
5
68%
68%
4
55%
55%
3
42%
42%
2
28%
29%
1
14%
15%
P20S: MVOLT and HVOLT
AO Position
% Lumens
% Wattage
8
100%
100%
7
94%
94%
6
81%
80%
5
69%
68%
4
56%
54%
3
42%
41%
2
29%
29%
1
14%
15%
P20U: MVOLT and HVOLT
AO Position
% Lumens
% Wattage
8
100%
100%
7
94%
94%
6
81%
80%
5
69%
68%
4
56%
55%
3
43%
42%
2
29%
29%
1
15%
15%
DISCONTINUED
IM-396
P25S: MVOLT and HVOLT
AO Position
% Lumens
% Wattage
8
100%
100%
7
94%
94%
6
81%
80%
5
69%
67%
4
56%
54%
3
43%
41%
2
29%
28%
1
15%
15%
P25U: MVOLT and HVOLT
AO Position
% Lumens
% Wattage
8
100%
100%
7
94%
94%
6
81%
80%
5
69%
68%
4
56%
54%
3
43%
41%
2
30%
29%
1
15%
15%
P30S: MVOLT and HVOLT
AO Position
% Lumens
% Wattage
8
100%
100%
7
94%
94%
6
81%
80%
5
69%
67%
4
56%
54%
3
43%
41%
2
30%
28%
1
15%
15%
P30U: MVOLT and HVOLT
AO Position
% Lumens
% Wattage
8
100%
100%
7
94%
94%
6
81%
80%
5
70%
67%
4
57%
54%
3
44%
41%
2
30%
29%
1
15%
15%
P35S: MVOLT and HVOLT
AO Position
% Lumens
% Wattage
8
100%
100%
7
94%
94%
6
81%
79%
5
70%
67%
4
57%
54%
3
44%
41%
2
30%
28%
1
15%
15%
P40S: MVOLT and HVOLT
AO Position
% Lumens
% Wattage
8
100%
100%
7
95%
94%
6
82%
79%
5
70%
67%
4
57%
54%
3
44%
41%
2
31%
28%
1
16%
15%
P45S: MVOLT and HVOLT
AO Position
% Lumens
% Wattage
8
100%
100%
7
95%
94%
6
82%
79%
5
71%
67%
4
58%
54%
3
45%
41%
2
31%
28%
1
16%
14%
P50S: MVOLT and HVOLT
AO Position
% Lumens
% Wattage
8
100%
100%
7
95%
94%
6
82%
79%
5
71%
67%
4
59%
54%
3
45%
41%
2
32%
28%
1
16%
14%
DISCONTINUED
IM-396
P55S: MVOLT and HVOLT
AO Position
% Lumens
% Wattage
8
100%
100%
7
95%
94%
6
83%
79%
5
72%
67%
4
59%
54%
3
46%
41%
2
32%
28%
1
17%
14%
P60S: MVOLT and HVOLT
AO Position
% Lumens
% Wattage
8
100%
100%
7
95%
94%
6
83%
79%
5
72%
67%
4
60%
54%
3
47%
41%
2
33%
28%
1
17%
14%
P65S: MVOLT and HVOLT
AO Position
% Lumens
% Wattage
8
100%
100%
7
95%
94%
6
84%
79%
5
73%
67%
4
61%
53%
3
48%
40%
2
33%
28%
1
18%
14%
®
Acuity Lighting Group, Inc.
3825 Columbus Rd. S.W. Granville, OH 43023
IM-396 12/1 ©2021 Acuity Lighting Group Inc.
ALL RIGHTS RESERVED.
Visit our web site at www.holophane.com
Printed in USA
DISCONTINUED
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

AcuityBrands ESL2 User manual

Type
User manual

AcuityBrands ESL2 is a versatile and efficient LED luminaire designed for various indoor and outdoor lighting applications. With its durable construction and advanced features, it offers reliable illumination for a range of needs.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI