Heartland PRESTWICK Assembly Manual

Type
Assembly Manual

This manual is also suitable for

16660
STOP!
STOP!
Call Us First!
DO NOT RETURN TO STORE.
For immediate help with assembly or product information
call our toll free number:
1-800-577-9663
or email:
customerservice@backyardproductsllc.com
Our staff is ready to provide assistance
April through October M-F 8:00 AM to 6:00 PM EST
Saturday 8:30 AM to 4:30 PM EST
November through March M - F 8:00 AM to 5:00 PM EST
(This page intentionally left blank.)
01/13/2016
KEEP THIS MANUAL FOR FUTURE REFERENCE
ASSEMBLY MANUAL
BEFORE YOU BEGIN
IMPORTANT!
READ INSTRUCTIONS THOROUGHLY PRIOR TO BEGINNING ASSEMBLY.
- CUSTOMER SERVICE -
Call: 1- 800-577-9663 email: customerservice@backyardproductsllc.com
ACTUAL FLOOR SIZE IS: 96" x 120" (243,8 x 304,8 cm)
PRESTWICK 8' x 10' (244 x 304,8 cm)
ARCHITECTURAL SERIES
16660
A Backyard Products Company
• BUILDING RESTRICTIONS AND APPROVALS
Be sure to check with local building department and homeowners association for speci c restrictions and/ or requirements before building.
• ENGINEERED DRAWINGS
Contact our Customer Service Team if engineered drawings are needed to pull local permits.
• SURFACE PREPARATION
To ensure proper assembly you must build your shed on a level surface. Recommended methods and materials to level your shed are
listed on page 8.
• CHECK ALL PARTS
Inventory all parts listed on pages 3 - 4. Contact our Customer Service Team if any parts are missing or damaged.
• ADDITIONAL MATERIALS
You will need additional materials to complete your shed. See page 5 for required and optional materials and quantities.
2
TOOLS
Safety! Always use approved safety glasses during assembly.
OptionalRequired
HELPFUL REMINDER SYMBOLS
Look for these symbols for helpful reminders throughout this manual.
ORIENT LUMBER AND TRIM FOR BEST APPEARANCE
= Assistance Required; two or more people.
= Ensure squareness.
= Important required step or operation.
= Helpful assembly hint.
= Mark part with pencil.
= Beginning of steps for assembly or installation.
= You have  nished the assembly or installation.
= Level
Gloves
Framing lumber is graded for structural strength and not appearance. Exterior trim is graded for one good side.
Always install the material leaving the best edge and best surface visible. Please remember that these blemishes in no way
negatively affect the strength or integrity of our product. (See Fig. A, B, C.)
A
Safety Glasses
Tape Measure
Paint Tools
Ladder
Wood Glue
Caulk Gun
Hammer
Level
FINISH
BEGIN
Pencil
Phillips
Screwdriver
Drill / Driver
5/16" Drill Bit
1/8" Drill Bit
#2 Philips Drive Bit
Tool Belt/
Nail Pouch
Chalk Line
Nail Gun
• gun nails
Tin Snips
(for drip edge)
Square
or
Utility Knife
Shingle Blades
B C
x3
PLA
2 x 2 x 10-3/8" (5,1 x 5,1 x 26,4 cm)
PARTS LIST
INVENTORY YOUR PARTS before you begin.
We suggest sorting parts by the category they are listed in.
PARTS IDENTIFICATION AND SIZES
WOOD SIZE CONVERSION CHART
Nominal Board Size Actual Size
1" x 4".................3/4" x 3-1/2" (1,9 x 8,9 cm)
2" x 4"..............1-1/2" x 3-1/2" (3,8 x 8,9 cm)
2" x 3"..............1-1/2" x 2-1/2" (3,8 x 6,3 cm)
1" x 3".................3/4" x 2-1/2" (3,8 x 6,3 cm)
RS
RS
Part identication
letters are stamped on some parts.
Check these locations for
part stamp.
WALLS
RAFTERSDOOR
TRIM
1 x 3 x 5" (2,5 x 7,6 x 12,7 cm) Gauge Block for 3/4" (1,9 cm) measurement
x1
GAA
3/4"
(1,9 cm)
3
x1
YG
2 x 4 x 17-1/2" (2,5 x 10,2 x 44,5 cm)
2 x 4 x 72" (5,1 x 10,2 x 182,9 cm)
x16
TM
2 x 4 x 73-1/2" (5,1 x 10,2 x 186,7 cm)
x3
THA
2 x 4 x 21" (5,1 x 10,2 x 53,3 cm)
SBA
x1
3/8 x 4-3/4 x 61-1/2" (1 x 12,1 x 156,2 cm)
x2
2 x 4 x 48" (5,1 x 10,2 x 122 cm)
SP
x4
2 x 4 x 56" (5,1 x 10,2 x 142,2 cm)
QU
x1
x2
SZ
2 x 4 x 89" (5,1 x 10,2 x 226,1 cm)
x2
LV
2 x 3 x 22-1/2" (5,1 x 7,6 x 57,1 cm)
x4
QHA
2 x 4 x 59-7/8" (5,1 x 10,2 x 152,1 cm)
x1
3/8 x 2-1/2 x 61" (1 x 6,4 x 154,9 cm)
x1
3/8 x 2-1/2 x 61" (1 x 6,4 x 154,9 cm)
x2
3/8 x 4-3/4 x 61" (1 x 12,1 x 154,9 cm)
x2
3/8 x 4-3/4 x 61" (1 x 12,1 x 154,9 cm)
x2
FDA
19/32 x 2-1/2 x 55-1/8" (1,5 x 6,3 x 140 cm)
19/32 x 2-1/2 x 63" (1,5 x 6,4 x 160 cm)
x1
WR
OO
x2
1-1/4 x 2-1/2 x 69" (3,2 x 6,3 x 175,3 cm)
x2
GI
19/32 x 2-1/2 x 23" (1,5 x 6,3 x 58,4 cm)
x9
6 x 24" (15,2 x 61 cm)
x1
JF
1 x 4 x 60" (2,5 x 10,2 x 152,4 cm)
x10
2 x 4 x 59-7/8" (5,1 x 10,2 x 152,1 cm)
QJA
x6
GCA
1 x 3 x 9-1/2" (2,5 x 7,6 x 24,17 cm)
x8
RCO
2 x 4 x 8-7/8" (5,1 x 10,2 x 22,5 cm)
x3
PKA
2 x 2 x 12" (5,1 x 5,1 x 30,5 cm)
x3
PRO
2 x 2 x 10-3/8" (5,1 x 5,1 x 26,4 cm)
x4
NGO
1 x 3 x 11-7/8" (2,5 x 7,6 x 30,2 cm)
x2
FJ
1 x 4 x 11-7/8" (2,5 x 10,2 x 30,2 cm)
x4
PVA
2 x 4 x 5-7/8" (5,1 x 10,2 x 14,9 cm)
3/8 x 4-3/4 x 72" (1 x 12,1 x 182,9 cm)
x2
3/8 x 2-13/16 x 73-7/8" (1 x 7,1 x 187,6 cm)
x8
x3
2 x 4 x 14" (5,1 x 10,2 x 35,6 cm)
LPA
3/8 x 5-7/8 x 47-7/8" (1 x 12,1 x 121,6 cm)
x2
3/8 x 5-7/8 x 73-5/8" (1 x 14,9 x 187,6 cm)
x2
x1
BOXES
x3
BOXES
x305
x125
x12
x70
x96
x8
x12
NAIL BOXES
FASTENER/HARDWARE BAG
DOOR & WINDOW HARDWARE / VENT
ROOF PANELS
NOTE: Panel parts are not stamped.
NOTE: Panel parts are not stamped.
Roof panels are 7/16" (1,1 cm) thick.
7/16 x 11-7/8 x 48"
(1,1 x 30,2 x 121,9 cm)
x2
7/16 x 11-7/8 x 84"
(1,1 x 30,2 x 213,4 cm)
x2
7/16 x 36 x 48"
(1,1 x 91,4 x 121,9 cm)
x2
7/16 x 48 x 96"
(1,1 x 121,9 x 243,8 cm)
x2
1" (2,5 cm)
1/2" (1,3 cm)
2" (5,1 cm)
3" (7,6 cm)
3/4" (1,9 cm)
2" (5,0 cm)
3" (7,6 cm)
2" (5,1 cm)
1-1/2" (3,8 cm)
x42
1-5/8" (4,1 cm)
4
x1
T-Handle
x2
1-1/2" (3,8 cm)
(2 screws in each package)
x2
Vent
x1
56" Metal Threshold
3/4" (1,9 cm) x18
Bagged seperately / special coating
WALL PANELS, OVERHANG, SOFFIT & DOORS
x6
3/8 x 48 x 76"
(1 x 121,9 x 193 cm)
x1
3/8 x 48 x 76"
(1 x 121,9 x 193 cm)
x1
3/8 x 48 x 76"
(1 x 121,9 x 193 cm)
x2
3/8 x 23-7/8 x 76"
(1 x 60,6 x 193 cm)
x1
LEFT DOOR
x1
RIGHT DOOR
x2
1" (2,5 cm)
x8
(4 screws in each package)
Spring-Bolt
x2
3/8 x 24-3/8 x 48"
(1 x 61,9 x 121,9 cm)
x2
3/8 x 24-3/8 x 48"
(1 x 61,9 x 121,9 cm)
x2
3/8 x 11-7/8 x 58-1/4"
(1 x 30,2 x 148 cm)
x2
3/8 x 3-1/2 x 5-7/8"
(1 x 8,9 x 14,9 cm)
OPTIONAL MATERIALS
DRIP EDGE ..................... 43 Feet #15 ROOFING FELT
To cover 110 Sq. Ft. of roof area.
1" GALVANIZED ROOFING NAILS.........1/4 Lb
For roong felt.
REFER TO THE BACK OF THIS MANUAL AND THE MANUFACTURER’S INSTRUCTIONS
FOR INSTALLATION OF SHINGLES, DRIP EDGE AND FELT.
COMPLETING YOUR SHED
You will need these additional materials:
3-TAB SHINGLES ............................. 5 Bundles
PAINT FOR SIDING .......................... 2 Gallons
Use 100% acrylic latex exterior paint. (2) coats recommended.
CAULK ................................................. 2 Tubes
Use acrylic latex exterior caulk that is paintable.
1" GALVANIZED ROOFING NAILS.... 3 Lbs
For shingles.
PAINT FOR TRIM ........................... 2 Quarts
Use 100% acrylic latex exterior paint.
WOOD GLUE ....................... Exterior Rated
REINFORCED WOOD FLOOR FRAME (OPTIONAL)
x5
x20
2 x 4 x 8' (5 x 10 x 244 cm) Treated Lumber
Cut to (3) 2 x 4 x 93" (5 x 10 x 236 cm)
ea. 3" (7,6 cm) Hot Dipped Galvanized Nails
Optional 12" (30,5 cm) spacing
Standard 16" (40,7 cm) spacing
IMPORTANT! Depending on your specic use you may want to construct a heavy duty oor frame by adding additional oor joists
(shown below as shaded). Below is a list of additional materials (not included):
5
FOUNDATION OR FLOOR MATERIALS
ADDITIONAL MATERIALS
• This shed does not include any oor or leveling materials. Use our optional oor kit with building instructions and nails included.
• See the FLOOR LEVELING section on page 8 for recommended methods and suggested materials to properly level your oor,
as this will vary depending on your specic site.
• If you choose to install your kit on a concrete slab refer to page 6.
• If you choose to build your own wood oor foundation refer to page 7.
6
CONCRETE FOUNDATION
If you choose to install your kit on a concrete slab refer to the diagram below.
A
B
C
4"
(10,2 cm)
3-1/2"
(8,9 cm)
D
O
O
R
A B CActual Floor SizeBuilding Size
A treated 2 x 4" (5,1 x 10,2 cm) sill plate is required when installing your shed on concrete.
• Use a high quality exterior grade caulk beneath all sill plates.
• Fasten 2 x 4" (5,1 x 10,2 cm) sill plates to slab using approved concrete anchors (fasteners not included).
• Check local code for concrete foundation requirements.
96" (243,8 cm)
113" (287 cm)
8' x 10' (235 x 304,8 cm)
8' x 10' (243,8 x 304,8 cm)
120" (304,8 cm)
Treated Sill Plate
Caulk between sill plate
and concrete.
2 x 4 x 8' (5,1 x 10,2 x 243,8 cm)
2 x 4 x 10' (5,1 x 10,2 x 305 cm)
Requires:
x2
x2
MUST be treated lumber.
MUST be treated lumber.
Caulk
x2
Allow new concrete slabs to cure for at least seven (7) days.
NOTES
ACTUAL FLOOR SIZE IS: 96" x 120" (243,8 x 304,8 cm)
BUILD YOUR OWN WOOD FLOOR OPTION
(Materials not included.)
2" x 4" x 10' (5,1 x 10,2 x 304,8 cm)
2" x 4" x 8' (5,1 x 10,2 x 243,8 cm)
x2
x7
MUST be treated lumber
MUST be treated lumber
MUST be treated lumber
7
5/8" x 48" x 96" (1,6 x 121,9 x 243,8 cm)
x3
x1
x28
x28
1 lb. of 2" (5,1 cm) Hot Dipped Galvanized Box-Type Nails
40 Nails - 3" (7,6 cm) Hot Dipped Galvanized Box-Type Nails
MATERIAL REQUIRED
4" x 4" x 10' (10,2 x 10,2 x 304,8 cm)
x2
Screws for Frame to 4"x 4"
Minimum 3" screws / exterior grade.
D
O
O
R
120"
(304,8 cm)
96"
(243,8 cm)
93"
(236,2 cm)
16"
(40,6 cm)
16"
(40,6 cm)
3" (7,6 cm)
2" (5,1 cm)
3" (7,6 cm)
8
Measurements to
centers of 4x4's.
• 3" Screw angled into 4x4.
• (2) at each point frame
and 4x4 touch.
4x4 Runners
(not included).
• Level under 4x4 runners only.
• Locate leveling material 12" from ends of runners and no more than 48" apart.
Asphalt shingles should be used between 4x4 runners and blocks or treated lumber. Never use
shingles in direct contact with ground.
• For best results and aiding in water drainage use gravel under each concrete block.
LEVELING METHODS
If you are building your shed on a concrete foundation see the following page.
CONCRETE
MATERIAL REQUIRED
x2
4" x 4" x 10' (10,2 x 10,2 x 304,8 cm) Treated Lumber
Fasteners for Frame to 4"x 4".
(3" Screws shown as one option.) Minimum (24) 3" screws / exterior grade.
Use only wood treated for ground contact and fasteners approved for use with treated wood.
Always support frame seams.
Leveling higher than 16" not recommended.
LEVELING MATERIALS
Gravel
2x4 Treated Lumber
Solid Masonry Blocks in 1", 2", 4" or 8" thickness
Asphalt Shingles
4" Block
8" Block
Gravel
Gravel
Do not exceed 16".
4x4 Runner
Shingle
Shingle
Maximum between leveling
material locations.
48"
12"
2x4 Treated Lumber
2" Block
Level
12"
D
O
O
R
12"
(30,5 cm)
12"
(30,5 cm)
96"
(243,8 cm)
Runners are generally 12"
(30,5 cm) from ends of oor
frame and under seams.
OPTIONAL WOOD FRAME FLOOR LEVELING OPTIONS
There are multiple ways to level your oor frame. Our recommended leveling method is shown below.
Leveling materials are not included in this kit.
PREFERRED METHOD - 4x4 TREATED RUNNERS (Typical for 8' x 10' Kit)
First, secure at ends
with one fastener.
Second, secure at ends
with one fastener.
150-15/16"
(383,4 cm)
150-15/16"
(383,4 cm)
Fig. A
LEVEL AND SQUARE FLOOR FRAME
Before attaching  oor decking, it is important to level and square the  oor frame.
A level and square  oor frame is required to correctly construct your shed.
FINISH
5
BEGIN
2
3
4
1
Use level and check the frame is level before applying  oor panels.
Check for frame squareness by measuring diagonally across corners. If the measurements are the
same, the frame is square. The diagonal measurement will be approximately 150-5/16" (383,4 cm).
When the frame is level and square secure one side of frame to the 4x4 runners using one fastener at
ends of each runner. At the opposite end of the frame, secure the frame to 4x4 runners with one fastener
at ends of each runner making sure the frame remains square (Fig. A).
Once the  oor frame is level and square fasten the frame at each point the frame contacts the 4x4
runners.
See page 8 for the preferred  oor leveling method.
9
10
IMPORTANT!
Check the oor frame is level after installing oor panels. Re-level if needed.
• The oor should be used as a stable work surface for wall construction.
Organize your assembly procedure during the build process
to avoid over-handling of the walls.
HINT:
IMPORTANT!
DOOR
EAVE WALL
EAVE WALL
FRONT WALL
BACK WALL
DOOR
PARTS REQUIRED:
FINISH
3
You have  nished rafter jig. Proceed to assemble your rafters.
11
RAFTER ASSEMBLY
96"
(243,8 cm)
22-1/4"
(56,5 cm)
22-1/4"
(56,5 cm)
48-1/8"
(122,2 cm)
3/4"
(1,9 cm)
PVA x3
3" (7,6 cm)
x6
x3
PVA
2 x 4 x 5-7/8" (5,1 x 10,2 x 14,9 cm)
Measure over 48-1/8" and up 22-1/4" from the  oor edges and secure the third PWA using two 3" screws.
Check this PVA is 22-1/4" at both ends for squareness.
BEGIN
¸
1
Secure one PVA ush to the  oor deck using two 3" screws.
Measure over 96-3/4" and install a second PVA ush to the  oor deck. PWA will overhang the  oor.
Secure using two 3" screws.
2
96-3/4"
(245,7 cm)
IMPORTANT MEASUREMENT !!
Fig. B
Fig. A
It is very important to assemble your rafters using the following method for an even and  at roof.
You will build a rafter jig using the  oor and three PVA parts as shown.
Floor Width
(2) 3" (7,6 cm)
Screws
in each PWA
There will be an
overhang on
this end.
Flush Flush
PARTS REQUIRED:
x 108
2" (5,1 cm)
x 10
1-5/8" (4,1 cm)
12
x10
2 x 4 x 59-7/8" (5,1 x 10,2 x 152,1 cm)
QJA
RAFTER ASSEMBLY
x9
6 x 24" (15,2 x 61 cm)
OSB OR WOOD GRAIN
1/4" (1,9 cm)
GAP
1/4" (1,9 cm)
GAP
QJA x2
Fig. A
1/4" (1,9 cm)
GAP
1/4" (1,9 cm)
GAP
Fig. C
Keep rafters  rmly against PVA at both ends when securing gusset.
Keep rafters tips  rmly against
PVA when securing gusset.
Repeat steps 1 - 3 to assemble three more rafters with two gussets.
Repeat steps 1 - 2 to assemble one rafter with only one gusset (Fig. D).
Remove PVA's from  oor.
Flip rafters over and attach a second gusset using glue and (12) 2" nails. No need to use jig for this step.
4
5
6
3
2
Keep QJA rm against outside PVA's as shown (Fig.A) and push rafters tight to the middle PVA. Rafters should
touch at tips (Fig. A).
Apply glue to rafters where gusset will attach (Fig. B).
Place gusset onto QJA holding a 1/4" gap from edge (Fig. C) and keeping rafters  rm as instructed. Secure
gusset using one 1-5/8" screw into each rafter. HINT: These screws will help hold the measurements when you
nail on gussets.
Use ten 2" nails to  nish securing the gusset to the rafters to pattern shown in Fig. C.
BEGIN
¸
1
Place two rafters QJA into the jig as shown.
YOU WILL BUILD 5 RAFTERS - ONE OF WHICH WILL HAVE ONLY 1 GUSSET
FINISH
You have  nished assembling your rafters.
FINISH
7
1-5/8" (4,1 cm)
Screw
QJA x2
Fig. B
Glue where
gusset installs
96-3/4"
(245,7 cm)
Fig. D
96-3/4"
(245,7 cm)
Glue where
gusset installs
13
BACK WALL FRAME
Toe-screw up through THA into SZ with two 3" screws.
3
2
1
BEGIN
3" (7,6 cm)
PARTS REQUIRED:
(2) 3" (7,6 cm)
Screws
3" (7,6 cm)
Nail
x1
x2
Fasten SZ to THA with one 3" nail as shown.
Orient parts on  oor as shown (Fig. A). Measure and mark.
Fig. A
2 x 4 x 73-1/2" (5,1 x 10,2 x 186,7 cm)
x1
THA
x1
SZ
2 x 4 x 89" (5,1 x 10,2 x 226,1 cm)
HINT:
89"
(2 26,1 cm)
44-1/2"
(113 cm)
73-1/2"
(186,7 cm)
44-1/2"
(113 cm)
1-1/2"
(3,8 cm)
3-1/2"
(8,9 cm)
3-1/2"
(8,9 cm)
3" (7,6 cm)
THA
SZ
FINISH
4
You have  nished building your back wall frame.
SZ
THA
2" (5,1 cm)
x8
14
Place SP on at under THA for temporary support as shown.
BEGIN
2
3
4
1
BACK WALL PANELS
PARTS REQUIRED:
For squareness maintain 1-3/4"
measurement along panel edge.
3/8 x 48 x 76"
(1 x 121,9 x 193 cm)
x1
Place 48" x 76" panel on frame with primed side facing up.
Use SP on edge to support the panel as shown.
x21
1-1/2" (3,8 cm)
Carefully ip the back wall frame over.
Hold panel ush against top plate SZ and keep 1-3/4" measurement along middle stud.
Nail using 1-1/2" and 2" nails spaced 6" apart.
2 x 4 x 48" (5,1 x 10,2 x 122 cm)
SP
x2
Temporary Support
76"
(193 cm)
48"
(121,9 cm)
1-3/4
(4,4 cm)
1-3/4
(4,4 cm)
6"
(15,2cm)
SZ
SP (on edge)
Temporary Support
2" (5,1 cm)
Nails
SP (on at)
Temporary Support
THA
Flush
Primed side UP
1-1/2" (3,8 cm)
Nails
2" (5,1 cm)
x8
15
3/8 x 48 x 76"
(1 x 121,9 x 193 cm)
x1
Place panel on frame as shown with primed side facing up and  ush to installed panel.
Use SP to support frame and panel while nailing.
6
5
BACK WALL PANELS
PARTS REQUIRED:
FINISH
7
You have  nished installing your back wall panels.
x21
1-1/2" (3,8 cm)
Hold panel tight to the installed panel and tight against top plate.
Nail using 1-1/2" and 2" nails spaced 6" apart.
To draw panels tight
angle nail at seam.
76"
(193 cm)
48"
(121,9 cm)
6"
(15,2cm)
2" (5,1 cm)
Nails
For squareness hold panel tight
against left panel and top plate.
2 x 4 x 48" (5,1 x 10,2 x 122 cm)
SP
x1
Temporary Support
Primed side UP
SP (on edge)
Temporary Support
1-1/2" (3,8 cm)
Nails
PARTS REQUIRED:
HINT:
Center on
marks.
TM
SP
TM
SP
TM x6
48"
(121,9 cm)
48"
(121,9 cm)
48"
(121,9 cm)
24"
(61 cm)
1-1/2"
(3,8 cm)
1-1/2"
(3,8 cm)
96"
(243,8 cm)
72"
(182,9 cm)
72"
(182,9 cm)
120"
(304,8 cm)
72"
(182,9 cm)
1
BEGIN
2
3
Orient parts on edge on  oor. Measure and mark.
Use two 3" nails at each mark.
Repeat STEPS 1 - 2 to build the second eave wall frame.
You have  nished building your eave wall frames.
EAVE SIDE WALL FRAMING
3" (7,6 cm)
FINISH
4
3" (7,6 cm)
Nails
x56
TOENAILING
IMPORTANT! YOU WILL BUILD TWO IDENTICAL EAVE SIDE WALLS.
16
2 x 4 x 72" (5,1 x 10,2 x 182,9 cm)
x16
TM
2 x 4 x 48" (5,1 x 10,2 x 122 cm)
SP
x4
PARTS REQUIRED:
3/4"
GAUGE BLOCK
GAA
EAVE SIDE WALL PANELS
3/8 x 48 x 76" (1 x 121,9 x 193 cm)
x1
2" (5,1 cm)
x45
Place a 48 x 76" panel onto wall frame with primed side up as shown.
Use the GAA gauge block to mark the 3/4" side measurement on the wall stud.
Keep panel ush along top of frame. Secure panel with two 2" nails in the corners (Fig. A).
3
2
Nail the panel using 2" nails 6" apart
on edges and 12" apart inside panel.
Ensure your wall frame is square by installing one panel and squaring frame.
Move to the opposite end. Using the long edge
of the panel as a lever, move the panel side-
to-side until you have a 3/4" measurement on
the wall stud. Secure corner with two 2" nails
(Fig. B).
For squareness maintain Flush and
3/4" measurement along panel edge.
BEGIN HERE
6"
(15,2 cm)
3/4"
(1,9 cm)
3/4"
(1,9 cm)
48"
(121,9 cm)
12"
(30,5 cm)
Primed side UP
3/4" Gauge
Block
1
BEGIN
17
Fig. A
Fig. B
3/4"
(1,9 cm)
3/4"
(1,9 cm)
2 Nails
Flush
2 Nails
Flush
BEGIN HERE
Primed side UP
6"
(15,2 cm)
48"
(121,9 cm)
23-7/8"
(60,6 cm)
12"
(30,5 cm)
18
2" (5,1 cm)
PARTS REQUIRED:
EAVE SIDE WALL PANELS
x1x1
x77
Place 23-7/8" x 76" panel on frame as shown with primed side facing up  ush with  rst
panel. Nail using 2" nails 6" apart on edges and 12" apart inside panel.
Place 48" x 76" panel on frame as shown with primed side facing up  ush with 23-7/8"
panel. Nail using 2" nails 6" apart on edges and 12" apart inside panel.
Repeat STEPS 1 - 5 to install second eave side wall panels.
4
5
6
You have  nished building your eave walls.
FINISH
7
Flush Flush Flush
To draw panels tight
at seams angle nail.
3/8 x 48 x 76"
(1 x 121,9 x 193 cm)
3/8 x 23-7/8 x 76"
(1 x 60,6 x 193 cm)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65

Heartland PRESTWICK Assembly Manual

Type
Assembly Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI