Cisco Systems Intelligent Gigabit Ethernet Switch Module User manual

Category
Network switches
Type
User manual

This manual is also suitable for

IBM
ERs erver
Cisco Systems Intelligent Gigabit Ethernet Switch
Module for the IBM Eserver BladeCenter
System Message Guide
Cisco IOS Release 12.1(14)AY
Note: Before using this information and the product it supports, read the general information in Appendix B.“Getting help
and technical assistance” and Appendix C.“Notices”.
12
1
First Edition (June 2004)
2
© Copyright International Business Machines Corporation 2004. All rights reserved.
US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule
Contract with IBM Corp.
© Copyright IBM Corp. 2004 1
Contents
Preface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Audience. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Related Publications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Chapter 1. System Message Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
How to Read System Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Error Message Traceback Reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Chapter 2. Message and Recovery Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . 11
CIGESM Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
CMP Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
DOT1X Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
DTP Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
EC Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
ETHCNTR Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
HWMATM_MOD Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
PLATFORM_CAT2950 Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
PLATFORM_CATALYST2950 Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
PM Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
PORT SECURITY Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
SPAN Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
SPANTREE Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
SPANTREE_FAST Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
SPANTREE_VLAN_SWITCH Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
STORM_CONTROL Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
SW_VLAN Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
UDLD Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
UFAST_MCAST_SW Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Appendix A. Security and QoS Configuration Messages. . . . . . . . . . . . . . . . . . 47
Appendix B. Getting help and technical assistance . . . . . . . . . . . . . . . . . . . . . . 53
Before you call . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Using the documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Getting help and information from the World Wide Web. . . . . . . . . . . . . . . . . . . . . . 53
Software service and support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Hardware service and support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Appendix C. Notices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Edition notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Trademarks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
2 BookTitle change in special and import
© Copyright IBM Corp. 2004 3
Preface
Audience
This guide is for the networking professional managing the Cisco Systems Intelligent
Gigabit Ethernet Switch Module, hereafter referred to as the switch. Before using this
guide, you should have experience working with the switch and its software features.
Purpose
This guide describes only the switch-specific system messages that you might
encounter.
This guide does not describe how to install your switch or how to configure software
features on your switch. It also does not provide detailed information about commands
that have been created or changed for use by the switch. For hardware installation
information, refer to the hardware installation guide that shipped with your switch. For
software information, refer to the software configuration guide and the command
reference for this release.
Conventions
This publication uses these conventions to convey instructions and information:
Command descriptions use these conventions:
Commands and keywords are in boldface text.
Arguments for which you supply values are in italic.
Square brackets ([ ]) mean optional elements.
Braces ({ }) group required choices, and vertical bars ( | ) separate the alternative
elements.
Braces and vertical bars within square brackets ([{ | }]) mean a required choice
within an optional element.
Interactive examples use these conventions:
Terminal sessions and system displays are in
screen font.
Information you enter is in
boldface screen font.
Nonprinting characters, such as passwords or tabs, are in angle brackets (< >).
Notes use this convention:
Note: Means reader take note. Notes contain helpful suggestions or references
to materials not in this manual.
Related Publications
In addition to this document, the following related documentation comes with the
Gigabit Ethernet switch module:
Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM eServer
BladeCenter System Release Notes
Note: Switch requirements and procedures for initial configurations and software
upgrades tend to change and therefore appear only in the release notes. Before
4 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide
installing, configuring, or upgrading the switch, refer to the release notes for the
latest information.
Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM eServer
BladeCenter System Command Reference (order number TBD)
This document is in PDF form on the IBM BladeCenter Documentation CD. It
includes:
Command line interface (CLI) modes
Command line interface commands and examples
Syntax description
Defaults
Command history
Usage guidelines
Related commands
Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM eServer
BladeCenter Software Configuration Guide
This Cisco document is in PDF on the IBM BladeCenter Documentation CD. It
contains software configuration information for the Gigabit Ethernet switch
module. It provides:
Configuration instructions for your Gigabit Ethernet switch module
Information about features
Information about getting help
Guidance for planning, implementing, and administering LAN operating
system software
Usage examples
Troubleshooting information for your Gigabit Ethernet switch module
Cisco Intelligent Gigabit Ethernet Switch Module for the IBM eServer
BladeCenter Installation Guide
This document contains installation and configuration instructions for the Gigabit
Ethernet switch module. This document also provides general information about
your Gigabit Ethernet switch module, including warranty information, and how to
get help. This document is also on the IBM BladeCenter Documentation CD.
eServer BladeCenter Type 8677 Installation and Users Guide
This document is in PDF on the IBM BladeCenter Documentation CD. It contains
general information about your BladeCenter unit, including:
Information about features
How to set up, cable, and start the BladeCenter unit
How to install options in the BladeCenter unit
How to configure the BladeCenter unit
How to perform basic troubleshooting of the BladeCenter unit
How to get help
BladeCenter Management Module User’s Guide
This document is in PDF on the IBM BladeCenter Documentation CD. It
provides general information about the management module, including:
Information about features
How to start the management module
Preface 5
How to install the management module
How to configure and use the management module
BladeCenter HS20 Installation and Users Guide (for each blade server type)
These documents are in PDF on the IBM BladeCenter Documentation CD. Each
provides general information about a blade server, including:
Information about features
How to set up and start your blade server
How to install options in your blade server
How to configure your blade server
How to install an operating system on your blade server
How to perform basic troubleshooting of your blade server
How to get help
Cisco IOS Release 12.1 documentation at
http://www.cisco.com/en/US/products/sw/iosswrel/ps1831/index.html
Cisco IOS Release 12.2 documentation at
http://www.cisco.com/en/US/products/sw/iosswrel/ps1835/index.html
6 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide
© Copyright IBM Corp. 2004 7
Chapter 1. System Message Overview
This guide describes the switch-specific system messages. During operation, the
system software sends these messages to the console (and, optionally, to a logging
server on another system). Not all system messages indicate problems with your
system. Some messages are purely informational, whereas others can help diagnose
problems with communications lines, internal hardware, or the system software. This
guide also includes error messages that appear when the system fails.
Note: The Catalyst 2950 switch messages listed in this guide also apply to the Cisco
Systems Intelligent Gigabit Ethernet Switch Module.
This chapter contains these sections:
How to Read System Messages, on page 7
Error Message Traceback Reports, on page 9
How to Read System Messages
System messages begin with a percent sign (%) and are structured as follows:
%FACILITY-SEVERITY-MNEMONIC: Message-text
FACILITY is a code consisting of two or more uppercase letters that show the
facility to which the message refers. A facility can be a hardware device, a
protocol, or a module of the system software. Table 1 lists the system facility
codes.
Table 1. Facility Codes .
Facility Code Description Location
CIGESM Cisco Systems Intelligent
Gigabit Ethernet Switch Module
(CIGESM)
“CIGESM Messages” section on
page 12
CMP Cluster Membership Protocol “CMP Messages” section on
page 15
DOT1X 802.1X “DOT1X Messages” section on
page 16
DTP Dynamic Trunking Protocol “DTP Messages” section on
page 17
EC EtherChannel “EC Messages” section on
page 18
ETHCNTR Ethernet controller “ETHCNTR Messages” section on
page 21
HWMATM_MOD Hardware MAC address table
manager
“HWMATM_MOD Messages”
section on page 22
PLATFORM_CAT2950 Application-specific Integrated
Circuit (ASIC) for the switch
“PLATFORM_CAT2950
Messages” section on page 22
PLATFORM_CATALYST2950 Low-level platform messages “PLATFORM_CAT2950
Messages” section on page 22
PM Port manager “PM Messages” section on
page 26
PORT_SECURITY Port security “PORT SECURITY Messages
section on page 31
SPAN Switch Port Analyzer (SPAN) “SPAN Messages” section on
page 31
8 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide
SEVERITY is a single-digit code from 0 to 7 that reflects the severity of the
condition. The lower the number, the more serious the situation. Table 2 lists the
message severity levels.
MNEMONIC is a code that uniquely identifies the message.
Message-text is a text string describing the condition. This portion of the message
sometimes contains detailed information about the event, including terminal port
numbers, network addresses, or addresses that correspond to locations in the
system memory address space. Because the information in these variable fields
changes from message to message, it is represented here by short strings
enclosed in square brackets ([ ]). A decimal number, for example, is represented
as [dec]. Table 3 lists the variable fields in messages.
SPANTREE Spanning tree “SPANTREE Messages” section
on page 32
SPANTREE_FAST Spanning-tree fast convergence “SPANTREE_FAST Messages”
section on page 38
SPANTREE_VLAN_SWITCH Spanning-tree VLAN switch “SPANTREE_VLAN_SWITCH
Messages” section on page 38
STORM_CONTROL Storm control “STORM_CONTROL Messages
section on page 38
SW_VLAN VLAN manager “SW_VLAN Messages” section on
page 39
UDLD UniDirectional Link Detection
(UDLD)
“UDLD Messages” section on
page 43
UFAST_MCAST_SW UplinkFast multicast software “UFAST_MCAST_SW Messages”
section on page 44
Table 1. Facility Codes (Continued).
Facility Code Description Location
Table 2. Message Severity Levels .
Severity Level Description
0 – emergency System is unusable.
1 – alert Immediate action required.
2 – critical Critical condition.
3 – error Error condition.
4 – warning Warning condition.
5 – notification Normal but significant condition.
6 – informational Informational message only.
7 – debugging Message that appears during debugging only.
Table 3. Representation of Variable Fields in Messages .
Representation Type of Information
[dec] Decimal integer
[char] Single character
[chars] Character string
[enet] Ethernet address (for example, 0000.FEED.00C0)
[hex] Hexadecimal integer
[inet] Internet address
Chapter 1. System Message Overview 9
This is a sample system message:
%EC-5-UNBUNDLE:Interface Gi0/2 left the port-channel Po2
The messages in Chapter 2 “Message and Recovery Procedures, are described in
alphabetical order by facility code with the most severe (lowest number) errors
described first.
Error Message Traceback Reports
Some messages describe internal errors and contain traceback information. This
information is very important and should be included when you report a problem to
your technical support representative.
This message example includes traceback information:
-Process= "Exec", level= 0, pid= 17
-Traceback= 1A82 1AB4 6378 A072 1054 1860
Some messages ask you to copy the messages and take further action. These online
tools can provide more information about messages:
Output Interpreter
The Output Interpreter provides additional information and suggested fixes based
on the output of many CLI commands, such as the the show tech-support
privileged EXEC command. You can access the Output Interpreter at this URL:
https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl
Bug Toolkit
The Bug Toolkit provides information on open and closed caveats, and allows you
to search for all known bugs in a specific Cisco IOS Release. You can access the
Bug Toolkit at this URL:
http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl
If you still cannot determine the nature of the error, provide the information you have
gathered to your technical support representative.
10 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide
© Copyright IBM Corp. 2004 11
Chapter 2. Message and Recovery Procedures
This chapter describes the switch system messages in alphabetical order by facility.
Within each facility, the messages are listed by severity levels 0 to 7; 0 is the highest
severity level, and 7 is the lowest severity level. Each message is followed by an
explanation and a recommended action.
Notes:
1. The messages listed in this chapter do not include the date/time stamp
designation that displays only if the software is configured for system log
messaging.
2. The Catalyst 2950 switch messages listed in this chapter also apply to the Cisco
Systems Intelligent Gigabit Ethernet Switch Module.
This chapter contains these message categories:
CIGESM Messages, on page 12
CMP Messages, on page 15
DOT1X Messages, on page 16
DTP Messages, on page 17
EC Messages, on page 18
ETHCNTR Messages, on page 21
HWMATM_MOD Messages, on page 22
PLATFORM_CAT2950 Messages, on page 22
PLATFORM_CATALYST2950 Messages, on page 26
PM Messages, on page 26
PORT SECURITY Messages, on page 31
SPAN Messages, on page 31
SPANTREE Messages, on page 32
SPANTREE_FAST Messages, on page 38
SPANTREE_VLAN_SWITCH Messages, on page 38
STORM_CONTROL Messages, on page 38
SW_VLAN Messages, on page 39
UDLD Messages, on page 43
UFAST_MCAST_SW Messages, on page 44
12 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide
CIGESM Messages
This section contains the Cisco Systems Intelligent Gigabit Ethernet Switch Module
(CIGESM) messages.
PLATFORM_CIGESM-2-OVER_THERMAL_THRESH2: The Switch Module has exceeded its second thermal
threshold.
Explanation This message means that the switch temperature has exceeded the second thermal
threshold 185°F (85°C), and that the switch is operating in an environment that can cause damage to the
hardware. The BladeCenter chassis will shut down the switch shortly after this condition is detected.
Response Verify that environmental conditions of the BladeCenter chassis are adequate. Do not restart
the switch until the overtemperature condition has been resolved.
PLATFORM_CIGESM-3-IMAGEUPGRADEFAIL: PIC microcontroller image upgrade failed.
Explanation This message means that the PIC microcontroller image upgrade failed, because the new
PIC microcontroller image failed the sanity check or failed the readback verification.
Response Perform the PIC microcontroller image upgrade again.
PLATFORM_CIGESM-4-OVER_THERMAL_THRESH1: The Switch Module has exceeded its first thermal threshold.
Explanation This message means that the switch temperature has exceeded the first thermal threshold,
and the switch is still operating normally. The first thermal threshold is 167°F (75°C). Temperature inside
the BladeCenter chassis should be monitored.
Response No action is required.
IPLATFORM_CIGESM-4-SWITCHRESETPIC: Keepalive ECHO failed, PIC microcontroller has been reset.
Explanation This message means that the PIC microcontroller has not responded to three consecutive
keepalive messages. The switch re-set the PIC microcontroller to reestablish communication.
Response No action is required.
PLATFORM_CIGESM-4-UNDR_THERMAL_THRESH2: The Switch Module has recovered from second thermal
threshold.
Explanation This message means that the switch temperature no longer exceeds the second thermal
threshold of 185°F (85°C). The switch might still be operating over the first thermal threshold of 167°F
(75°C). Temperature inside the chassis should be monitored.
Response No action is required.
Chapter 2. Message and Recovery Procedures 13
PLATFORM_CIGESM-5-DISABLE_EXTERN: Request from Management Module: disable all external ethernet ports
gi0/17 - 20.
Explanation This message means that the switch received a request from the management module to
shut down ports 17 to 20.
Response No action is required.
PLATFORM_CIGESM-5-DISABLE_EXTERNMGMT: Request from Management Module: Switch can be managed
from mgmt module ports only gi0/15 - 16.
Explanation This message means that the switch can only be managed through ports 15 and 16 through
the management module. HTTP, SNMP, and Telnet data paths must go through the management module.
Response No action is required.
PLATFORM_CIGESM-5-ENABLE_EXTERN: Request from Management Module: enable external ethernet ports
gi0/17 - 20.
Explanation This message means that the switch performed a no shutdown interface configuration
command on ports 17 to 20, because of a request from the management module to enable these ports.
Response No action is required.
PLATFORM_CIGESM-5-ENABLE_EXTERNMGMT: Request from Management Module: Switch can be managed
from all ports.
Explanation This message means that the switch can be managed through ports 17 - 20 as well as
through the management module ports 15 and 16.
Response No action is required.
PLATFORM_CIGESM-5-MM_NEITHER: The Switch Module cannot detect either Managment Module as active.
Explanation This message means that the switch cannot determine which management module is the
active primary. This does not affect the operation of the switch.
Response No action is required.
PLATFORM_CIGESM-5-MM_SWITCHOVER: The active Managment Module is now in slot [dec].
Explanation This message means that the switch recognizes that the management module in the
specified slot is the active primary. [dec] is the chassis slot number.
Response No action is required.
14 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide
PLATFORM_CIGESM-5-UNDR_THERMAL_THRESH1: The Switch Module has recovered from first thermal
threshold.
Explanation This message means that the switch temperature no longer exceeds the first thermal
threshold of 167°F (75°C). Temperature inside the chassis should be monitored.
Response No action is required.
PLATFORM_CIGESM-6-ACQUIRE_IP: Request from Management Module: acquire IP Address from EEPROM.
Explanation This message means that the switch should use the IP address, netmask, and default IP
gateway from EEPROM memory. This information can be configured through the CLI or through the
BladeCenter Management Module WEB page.
Response No action is required.
PLATFORM_CIGESM-6-PICREADFAIL: Read request to PIC microcontroller failed.
Explanation This message means that the PIC microcontroller failed to respond to a Read request. The
PIC microcontroller might be too busy to respond and thus the Read request timed out, or a checksum
error in the communication exists.
Response No action is required.
PLATFORM_CIGESM-6-PICWRITEFAIL: Write request to PIC microcontroller failed.
Explanation This message means that the PIC microcontroller failed to respond to a Write request. The
PIC microcontroller might be too busy to respond and thus the Write request timed out, or a checksum
error in the communication exists.
Response No action is required.
PLATFORM_CIGESM-6-RESETMGMT1: Request from Management Module received: reset ethernet port Gi0/15.
Explanation This message means that the switch had reset port 15, because of a request from the
management module to reset the port.
Response No action is required.
PLATFORM_CIGESM-6-RESETMGMT2: Request from Management Module received: reset ethernet port Gi0/16.
Explanation This message means that the switch had reset port 16, because of a request from the
management module to reset the port.
Response No action is required.
Chapter 2. Message and Recovery Procedures 15
CMP Messages
This section contains the Cluster Membership Protocol (CMP) messages.
CMP-5-ADD: The Device is added to the cluster (Cluster Name:[chars], CMDR IP Address [inet]).
Explanation This message means that the device is added to the cluster. [chars] is the cluster name,
and [inet] is the Internet address of the command switch.
Response No action is required.
CMP-5-MEMBER_CONFIG_UPDATE: Received member configuration from member [dec].
Explanation This message means that the active or standby command switch received a member
configuration. [dec] is the member number of the sender.
Response No action is required.
CMP-5-MGMT_VLAN_CHNG: The management vlan has been changed to [dec].
Explanation This message means that the management VLAN has changed. [dec] is the new
management VLAN number.
Response No action is required.
CMP-5-NBR_UPD_SIZE_TOO_BIG: Number of neighbors in neighbor update is [int], maximum number of
neighbors allowed in neighbor update is [int].
Explanation This message means that the number of cluster neighbors in the clustering neighbor
update packet exceeds the number of neighbors supported by the clustering module design. [int] is the
number of cluster neighbors.
Response No action is required.
CMP-5-REMOVE: The Device is removed from the cluster (Cluster Name:[chars]).
Explanation This message means that the device is removed from the cluster. [chars] is the cluster
name.
Response No action is required.
16 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide
DOT1X Messages
This section contains the 802.1X authorization messages.
DOT1X_MOD-3-NULLPTR: Unexpected null pointer in [chars] at [dec].
Explanation This message means that an internal software error occurred. [chars] is the software
filename, and [dec] is the line number in the file.
Response Find out more about the error by using the show tech-support privileged EXEC command and
by copying the error message exactly as it appears on the console or system log and entering it in the Output
Interpreter tool. Use the Bug Toolkit to look for similar reported problems. For more information about these
online tools , see the “Error Message Traceback Reports” section on page 9.
DOT1X-3-ROUTEDPORT: Received vlan id ([dec]) from RADIUS for routed port [chars].
Explanation This message means that during 802.1X authorization, the RADIUS server provided a
VLAN ID for a routed port.
Response Remove the VLAN ID in the RADIUS configuration, or configure the port as an access port.
DOT1X-3-VLANINVALID: Received invalid vlan ([dec]) from RADIUS for [chars].
Explanation This message means that during 802.1X authorization, the RADIUS server provided a
VLAN ID that is not configured on the switch.
Response Change the VLAN ID in the RADIUS configuration, or configure the VLAN on the switch.
DOT1X-3-VLANMALFORMED: Received malformed vlan from RADIUS for [chars].
Explanation This message means that during 802.1X authorization, the RADIUS server provided an
invalid VLAN ID.
Response Correct the VLAN ID in the RADIUS configuration.
DOT1X-3-VOICEVLAN: Received voice vlan ([dec]) from RADIUS for [chars].
Explanation This message means that during 802.1X authorization, the RADIUS server provided a
VLAN ID that conflicts with the voice VLAN ID on the port.
Response Change the VLAN ID in the RADIUS configuration, or change the voice VLAN on the switch
port.
Chapter 2. Message and Recovery Procedures 17
DTP Messages
This section contains the Dynamic Trunking Protocol (DTP) messages.
DTP-4-MEM_UNAVAIL: Memory was not available to perform the trunk negotiation action.
Explanation This message means that the system is unable to negotiate trunks because of a lack of
memory.
Response Reduce other system activity to ease the memory demands.
DTP-4-TMRERR: An internal timer error occurred when trunking on interface [chars].
Explanation This message means that a timer used by the trunking protocol unexpectedly expired.
[chars] is the trunked interface.
Response This error is internally corrected, and no long-term ramifications exist. However, if more
problems with trunking occur, reload the switch by using the reload privileged EXEC command.
DTP-4-UNKN_ERR: An unknown operational error occurred.
Explanation This message means that the system is unable to negotiate trunks because an internal
operation generated an unexpected error.
Response Reload the switch by using the reload privileged EXEC command.
DTP-5-ILGLCFG: Illegal config (on, isl--on, dot1q) on [chars].
Explanation This message means that one end of the trunk is configured as on, ISL, and the other end
is configured as on, 802.1Q. [chars] is the interface.
Response This configuration is illegal and will not establish a trunk between two switches. You must
change the encapsulation type so that both ends of the trunk match.
DTP-5-NONTRUNKPORTON: Port [chars] has become non-trunk.
Explanation This message means that the interface changed from trunk to access. [chars] is the
interface that changed.
Response This message is provided for information only.
DTP-5-TRUNKPORTCHG: Port [chars] has changed from [chars] trunk to [chars] trunk.
Explanation This message means that the encapsulation type of the trunk has changed. The first [chars]
is the interface, the second [chars] is the original encapsulation type, and the third [chars] is the new
encapsulation type.
Response This message is provided for information only.
18 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM Eserver BladeCenter System Message Guide
DTP-5-TRUNKPORTON: Port [chars] has become [chars] trunk.
Explanation This message means that the interface changed from an access to a trunk. The first [chars]
is the interface, and the second [chars] is the encapsulation.
Response This message is provided for information only.
EC Messages
This section contains the EtherChannel, Link Aggregation Control Protocol (LACP),
and Port Aggregation Protocol (PAgP) messages.
EC-4-NOMEM: Not enough memory available for [chars].
Explanation This message means that either the LACP or the PAgP EtherChannel could not obtain the
memory it needed to initialize the required data structures. [chars] is the name of the data structure.
Response Find out more about the error by using the show tech-support privileged EXEC command and
by copying the error message exactly as it appears on the console or system log and entering it in the Output
Interpreter tool. Use the Bug Toolkit to look for similar reported problems. For more information about these
online tools , see the “Error Message Traceback Reports” section on page 9.
EC-5-BUNDLE: Interface [chars] joined port-channel [chars].
Explanation This message means that the listed interface joined the specified EtherChannel. The first
[chars] is the physical interface, and the second [chars] is the EtherChannel interface.
Response No action is required.
EC-5-CANNOT_ALLOCATE_AGGREGATOR: Aggregator limit reached, cannot allocate aggregator for group [dec].
Explanation This message means that the aggregator cannot be allocated in the group.
Response Change the port attributes of the ports in the group so that they match and join the same
aggregator.
EC-5-CANNOT_BUNDLE_LACP: [chars] is not compatible with aggregators in channel [dec] and cannot attach to
them ([chars]).
Explanation This message means that the port has port attributes that are different from the port
channel or ports within the port channel.
Response Change the port attributes so that they match the other ports in the EtherChannel.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62

Cisco Systems Intelligent Gigabit Ethernet Switch Module User manual

Category
Network switches
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI