  • Hello! I am an AI chatbot trained to assist you with the MQ Multiquip C30HDZ Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
OPERATION MANUAL
THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
Revision #14 (01/12/21)
SERIES
MODEL C30HDZ
BALL VALVE CONCRETE PUMP
(DEUTZ F2L1011F DIESEL ENGINE)
To find the latest revision of this publication or
associated parts manual, visit our website at:
www.multiquip.com
PAGE 2 — MAYCO C30HDZ PUMP — OPERATION MANUAL — REV. #14 (01/12/21)
PROPOSITION 65 WARNING
MAYCO C30HDZ PUMP — OPERATION MANUAL — REV. #14 (01/12/21) — PAGE 3
Grinding/cutting/drilling of masonry, concrete, metal and
other materials with silica in their composition may give
off dust or mists containing crystalline silica. Silica is a
basic component of sand, quartz, brick clay, granite and
numerous other minerals and rocks. Repeated and/or
substantial inhalation of airborne crystalline silica can
cause serious or fatal respiratory diseases, including
silicosis. In addition, California and some other
authorities have listed respirable crystalline silica as a
substance known to cause cancer. When cutting such
materials, always follow the respiratory precautions
mentioned above.
WARNING
Grinding/cutting/drilling of masonry, concrete, metal and
other materials can generate dust, mists and fumes
containing chemicals known to cause serious or fatal
injury or illness, such as respiratory disease, cancer,
birth defects or other reproductive harm. If you are
unfamiliar with the risks associated with the particular
process and/or material being cut or the composition of
the tool being used, review the material safety data
sheet and/or consult your employer, the material
manufacturer/supplier, governmental agencies such as
OSHA and NIOSH and other sources on hazardous
materials. California and some other authorities, for
instance, have published lists of substances known to
cause cancer, reproductive toxicity, or other harmful
effects.
Control dust, mist and fumes at the source where
possible. In this regard use good work practices and
follow the recommendations of the manufacturers or
suppliers, OSHA/NIOSH, and occupational and trade
associations. Water should be used for dust
suppression when wet cutting is feasible. When the
hazards from inhalation of dust, mists and fumes cannot
be eliminated, the operator and any bystanders should
always wear a respirator approved by NIOSH/MSHA for
the materials being used.
WARNING
SILICOSIS WARNING RESPIRATORY HAZARDS
SILICOSIS/RESPIRATORY WARNING
PAGE 4 — MAYCO C30HDZ PUMP — OPERATION MANUAL — REV. #14 (01/12/21)
MAYCO C30HDZ
CONCRETE PUMP
Proposition 65 Warning ..............................................2
Silicosis Warning ........................................................ 3
Table of Contents .......................................................4
Pump Specifications ...................................................5
Engine Specifications .................................................5
Pump Dimensions ......................................................6
Safety Message Alert Symbols .............................. 7-8
Rules for Safe Operation ..................................... 9-11
Towing Guidelines .............................................. 13-14
Trailer Safety Guidelines .................................... 15-17
Operation And Safety Decals ...................................19
Important Hand Signals ...........................................20
Pump Components ............................................ 21-22
Control Box Components .........................................23
Engine Components ................................................24
General Information .................................................25
How it Works ...................................................... 26-27
Operating Information ........................................ 28-32
Inspection ........................................................... 33-34
Startup/Shutdown Procedures.................................35
Maintenance (Pump) ......................................... 36-44
Engine Troubleshooting...................................... 45-46
Wiring Diagram ........................................................47
Wiring Diagram (Trailer Lights) ................................48
Appendix —
Slump Test Procedure ........................................49
Concrete Mix Information ............................ 50-52
Recommended Shotcrete System ............... 53-54
Recommended Shotcrete Accessories........ 55-56
TABLE OF CONTENTS
Specification and part
number are subject to change
without notice.
NOTE
MAYCO C30HDZ PUMP — OPERATION MANUAL — REV. #14 (01/12/21) — PAGE 5
PUMP SPECIFICATIONS
Table 1. C-30HDZ Pump Specifications
Pump Type Reciprocating Piston
Pumping Rate Up to 25 cu. yds. per hour*
Vertical Pumping Height Up to 150 ft. (45.73 m)
Horizontal Pumping Distance 400 - 500 ft. (122 - 152 m)*
Max. Concrete Piston Face
Pressure
500 PSI
Maximum Aggregate Size 1/2 in. minus (12.7 mm)
Hopper Capacity 6 cu. ft. etc.
Material Hose
2" or 2-1/2"
(50.8 or 63.5 mm)
Weight 2,950 lbs. (1,338 Kg)
Lube oil Box 7 Gallons (26.5 Liters)
Remote Control 125 ft. cable Standard
Tire Size
7.35" x 14"
(187 x 356 mm)
* Volume output will vary depending on mix design, slump, line size
used and job site conditions.
TABLE 2. ENGINE SPECIFICATIONS
Model
DEUTZ F2L1011F ENGINE
Type
Air/Oil-Cooled, Direct Injected, 4 Cycle Diesel
w/ Integrated Cooling System
Bore X Stroke
3.6 x 4.1 in.
(91 x 104 mm)
Compression Ratio 19.0 : 1
Cylinders 2
Displacement 41.7 cu. in. (0.68 L)
Intermittent Output 27 H.P. @ 2750 R.P.M.
Maximum Torque 59 lbs. per ft. @ 2550 R.P.M.
Fuel Tank Capacity Approx. 11 U.S. Gallons (43 L)
Fuel Type No. 2 Diesel
Fuel C
onsumption at Max. Rating
1.7 gal. per hour
(6.5 L per hour)
Fuel Consumption at Max. Torque
1.1 gal. per hour
(4.2 L per hour)
Lube Oil Capacity 6.8 qt. (6.5 L)
Minimum Idle Speed 900 RPMs
Air Cleaner Dry Type
Starting Method Electric Start
Dimensions (LxWxH)
19.0 x 18.0 x 27.0 in.
(483 x 457 x 686 mm)
Weight 367.4 lbs. (167 kg)
PAGE 6 — MAYCO C30HDZ PUMP — OPERATION MANUAL — REV. #14 (01/12/21)
PUMP DIMENSIONS
Figure 1. C30HDZ Concrete Pump Dimensions
MAYCO C30HDZ PUMP — OPERATION MANUAL — REV. #14 (01/12/21) — PAGE 7
SAFETY MESSAGE ALERT SYMBOLS
Safety precautions should be followed at all times when operating
this equipment. Failure to read and understand the Safety
Messages and Operating Instructions could result in injury to
yourself and others.
FOR YOUR SAFETY AND THE SAFETY OF OTHERS!
SAFETY MESSAGE ALERT SYMBOLS
The three (3) Safety Messages shown below will inform you
about potential hazards that could injure you or others. The Safety
Messages specifically address the level of exposure to the
operator, and are preceded by one of three words: DANGER,
WARNING, or CAUTION.
You WILL be KILLED or SERIOUSLY injured if you do
not follow directions.
You COULD be KILLED or SERIOUSLY injured if you
do not follow directions.
You CAN be injured if you do not follow directions
HAZARD SYMBOLS
Gasoline engine exhaust gases contain
poisonous carbon monoxide. This gas is
colorless and odorless, and can cause
death if inhaled. NEVER operate this
equipment in a confined area or enclosed
structure that does not provide ample free flow air.
Potential hazards associated with operation of the pump will be
referenced with Hazard Symbols which appear throughout this
manual, and will be referenced in conjunction with Safety
Message Alert Symbols. Some examples are listed below:
Gasoline
is extremely flammable, and its
vapors can cause an explosion if ignited.
DO NOT start the engine near spilled fuel
or combustible fluids. DO NOT fill the fuel
tank while the engine is running or hot.
DO NOT overfill tank, since spilled fuel
could ignite if it comes into contact with hot engine parts or
sparks from the ignition system. Store fuel in approved
containers, in well-ventilated areas and away from sparks and
flames. NEVER use fuel as a cleaning agent.
Engine components can generate extreme
heat. To prevent burns, DO NOT touch these
areas while the engine is running or
immediately after operations. NEVER operate
the engine with heat shields or heat guards
removed.
WARNING
DANGER
CAUTION
WARNING - LETHAL EXHAUST GASES
WARNING - BURN HAZARDS
WARNING - EXPLOSIVE FUEL
NOTE
This Owner's Manual has been
developed to provide complete
instructions for the safe and efficient
operation of the Mayco Model
C30HDZ Concrete Pump.
Refer to the engine manufacturers instructions for data relative
to its safe operation.
Before using this pump, ensure that the operating individual
has read and understands all instructions in this manual.
PAGE 8 — MAYCO C30HDZ PUMP — OPERATION MANUAL — REV. #14 (01/12/21)
SAFETY MESSAGE ALERT SYMBOLS
ALWAYS place the Engine ON/OFF switch
in the OFF position and remove the ignition
key when the pump is not in use.
ALWAYS wear approved
respiratory
protection.
ALWAYS wear approved
eye
and
hearing
protection.
Other important messages are provided throughout this manual
to help prevent damage to your concrete pump, other property,
or the surrounding environment.
This
pump
, other property, or the
surrounding environment could
be damaged if you do not follow
instructions.
NOTE
NEVER tamper with the factory settings of
the engine governor or settings. Personal
injury and damage to the engine or
equipment can result if operating in speed
ranges above maximum allowable.
CAUTION - OVER-SPEED CONDITIONS
CAUTION - ACCIDENTAL STARTING
CAUTION - RESPIRATORY HAZARDS
CAUTION - SIGHT AND HEARING HAZARDS
CAUTION - EQUIPMENT DAMAGE MESSAGES
NEVER operate equipment with covers,
or guards removed. Keep
fingers
,
hands
,
hair
and clothing away from all moving
parts to prevent injury.
WARNING - ROTATING PARTS
DO NOT operate at pressures exceeding the rating of the
entire material delivery system.
Use snap pins on all snap couplings.
WARNING
MAYCO C30HDZ PUMP — OPERATION MANUAL — REV. #14 (01/12/21) — PAGE 9
RULES FOR SAFE OPERATION
The following safety guidelines should always be used when
operating the Mayco C30HDZ Concrete Pump:
General Safety
DO NOT operate or service this equipment
before reading this entire manual.
ALWAYS read, understand, and follow
procedures in Operator’s Manual before
attempting to operate equipment.
ALWAYS be sure the operator is familiar with proper safety
precautions and operations techniques before using pump
This equipment should not be operated by persons under 18
years of age.
ALWAYS read, understand and follow procedures in
Operator’s Manual before attempting to operate equipment.
ALWAYS be sure the operator is familiar with proper safety
precautions and operations techniques before using pump
NEVER operate this equipment without proper protective
clothing, shatterproof glasses, steel-toed boots and other
protective devices required by the job.
Failure to follow instructions in this manual may lead to serious
injury or even death! This equipment is to be operated by
trained and qualified personnel only! This equipment is for
industrial use only.
ALWAYS wear proper respiratory (mask),
hearing and eye protection equipment when
operating the concrete pump.
NEVER operate this equipment when not feeling
well due to fatigue, llness or taking medicine.
NEVER operate this equipment under the
influence of
drugs
or
alcohol
.
DANGER - Read This Manual!
Whenever necessary, replace nameplate, operation and safety
decals when they become difficult read.
Manufacture does not assume responsibility for any accident
due to equipment modifications.
NEVER use accessories or attachments, which are not
recommended by Multiquip for this equipment. Damage to the
equipment and/or injury to user may result.
NEVER touch the hot exhaust manifold, muffler or cylinder.
Allow these parts to cool before servicing engine or
concrete pump.
High Temperatures – Allow the engine
to cool before adding fuel or performing
service and maintenance functions.
Contact with
hot!
components can cause
serious burns.
The engine section of this concrete pump requires an
adequate free flow of cooling air.
NEVER
operate the concrete
pump in any enclosed or narrow area where free flow of the
air is restricted. If the air flow is
restricted it will cause serious
damage to the concrete pump
or engine and may cause injury
to people. Remember the
concrete pump's engine gives
off
DEADLY
carbon monoxide
gas.
ALWAYS refuel in a well-ventilated area, away from sparks
and open flames.
ALWAYS use extreme caution when working with flammable
liquids. When refueling, stop the engine and allow it to cool.
DO NOT
smoke
around or near the machine. Fire or
explosion could result from fuel vapors, or if fuel is spilled on
a hot engine.
NEVER operate the concrete pump in an
explosive atmosphere or near
combustible materials. An explosion or fire
could result causing severe
bodily harm
or even death.
Topping-off to filler port is dangerous, as it tends to spill fuel.
Stop the engine when leaving the concrete pump unattended.
DO NOT leave the pump unattended. Use chock blocks if
parking pump on a grade.
Maintain this equipment in a safe operating condition at all
times.
PAGE 10 — MAYCO C30HDZ PUMP — OPERATION MANUAL — REV. #14 (01/12/21)
RULES FOR SAFE OPERATION
CAUTION must always be observed while servicing this
pump. Rotating parts can cause injury if contacted.
ALWAYS stored the pump in a clean, dry location out of the
reach of children.
ALWAYS use extreme care when operating near obstructions,
on slippery surfaces, grades and side slopes.
Unauthorized equipment modifications will void all
warranties.
Refer to the
Engine Owner's Manual
for engine technical
questions or information.
Before start-up, check the hopper and remove all obstructions.
Keep all hands out of the hopper when the engine is running.
DO NOT operate the pump with the hood open.
Replace any worn or damaged pump components
immediately.
ALWAYS turn the engine
OFF
before performing must be
before performing maintenance.
ALWAYS make sure pump is correctly secured to the trailer.
Check all supports attaching the pump to the trailer and make
sure they are tight.
ALWAYS make sure that the pump's trailer is placed on solid
level ground so that it cannot slide or shift around, endangering
workers. Place blocks under the trailer's bumper to make it
level (prevents tipping), and use a chocked block underneath
the wheels to prevent rolling. Also keep the immediate area
free of bystanders.
Before towing, check the hitch and secure the safety chain to
the towing vehicle. Also check for proper tire pressure.
Tow only with a vehicle and hitch rated to tow a 2,950 lbs.
(1,338 Kg) load.
If pump is equipped with ball hitch coupler, use only a 2” all
steel ball rated for a minimum of 5000 lbs. Use a 1” hardened
steel pull pin, if the pump is equipped with a pin hitch.
ALWAYS check the machine for loosened threads or bolts
before starting.
A copy of this manual shall accompany the pump at all times.
DO NOT use worn out hoses or couplings; inspect daily.
DO NOT disconnect the hose couplings or nozzle while they
are under pressure. Relieve the pressure by manually
swinging the clamp arm latch handle to the first open position
at the exhaust cone outlet.
The pump should NEVER be towed in excess of 45 MPH (or
less depending on road conditions).
If hose lines are
blocked
for any reason, or if the lines are
kinked
when starting up or during pumping cycle, the pump
pressure could straighten out the kink or force out the blockage.
This rapid surge of material could cause the lines to
move or
whip
in a manner that could cause injury to personnel.
Inspect the hose lines at all times
DO NOT tow the pump with the hopper full of material.
DO NOT tow the pump with the hoses attached.
NEVER disconnect any
emergency or safety devices
.
These devices are intended for operator safety. Disconnection
of these devices can cause severe injury, bodily harm or even
death! Disconnection of any of these devices will void all
warranties.
ALWAYS make sure the delivery system used, pipe hose,
clamps etc., exceed teh rated pressure of teh pump. In addition,
the pumping system should be checked for worn components
prior to start up. Use snap pins on all snap couplings.
MAYCO C30HDZ PUMP — OPERATION MANUAL — REV. #14 (01/12/21) — PAGE 11
Emergencies
ALWAYS know the location of the nearest
fire extinguisher
and
first aid kit
. Know the location of the nearest telephone.
Also know the phone numbers of the nearest
ambulance
,
doctor
and
fire department
. This information will be
invaluable in the case of an emergency.
Maintenance Safety
NEVER lubricate components or attempt service on a running
machine.
ALWAYS allow the machine a proper amount of time to cool
before servicing.
Keep the machinery in proper running condition.
Fix damage to the machine immediately and always replace
broken parts.
Dispose of hazardous waste properly. Examples of potentially
hazardous waste are used motor oil, fuel and fuel filters.
DO NOT use food or plastic containers to dispose of
hazardous waste.
DO NOT pour waste, oil or fuel directly onto the ground,
down a drain or into any water source.
Lifting
The pump has an operating weight of approximately 2,950
lbs. (1,338 Kg). Use lifting equipment capable of lifting this
weight.
RULES FOR SAFE OPERATION
PAGE 12 — MAYCO C30HDZ PUMP — OPERATION MANUAL — REV. #14 (01/12/21)
TOWING GUIDELINES
To reduce the possibility of an accident while transporting the
pump on public roads, always make sure that the trailer and the
towing vehicle are in good operating condition and both units
are mechanically sound.
The following list of suggestions should be used when towing
the pump:
Make sure that the hitch and coupling of the towing vehicle
are rated equal to, or greater than the trailer "gross vehicle
weight rating" (GVWR).
ALWAYS inspect the hitch and coupling for wear. NEVER
tow the light tower's trailer with defective hitches, couplings,
chains etc.
CHECK the tire air pressure on both the towing vehicle and
the trailer. Also check the tire tread wear on both vehicles.
ALWAYS make sure the trailer section of the pump is
equipped with a "Safety Chain".
ALWAYS attach trailer's safety chain to frame of towing
vehicle.
ALWAYS make sure that the vehicle and trailer directional,
backup, brake, and trailer lights are connected properly and
are working properly.
Remember in most cases the maximum speed unless
otherwise posted for highway towing is 45 MPH, however
before towing your pump, check your local state, and county
vehicle towing requirements. Recommended off-road towing
is not to exceed 10 MPH or less depending on type of terrain.
Place
chocked blocks
underneath wheel to prevent
rolling,
while parked.
Depending on soil conditions and location it may be
necessary to place
support blocks
underneath the trailer's
bumper to prevent
tipping
, while parked.
Inflate tires to correct pressure, inspect tires for cuts, and
excessive wear. See Table 3 (Tire Wear Troubleshooting).
Towing Safety Precautions
Pump Trailer Vehicle Connection
1. Check the vehicle hitch ball, and trailer coupler for signs of
wear or damage. Replace any parts that are worn or
damaged before towing.
2. Use only the 2-inch ball diameter with a towing capability of
5,000 lbs. (2,268 kg) as indicated on the trailer's coupler.
Use of any other ball diameter will create an extremely
dangerous condition which can result in separation of the
coupler and ball or ball failure.
3. Be sure the coupler is secured to the hitch ball and the lock
lever is down (locked).
4. Attach safety chains as shown in Figure 2. Remember to
cross
the safety chains.
5. After towing for about 50 miles recheck the entire towing
system for tightness.
Recommended Maintenance
1. Smear ball socket and clamp face with chassis grease.
Periodically oil pivot points and were surfaces of coupler
with SAE 30 W motor oil.
2. When parking or storing the concrete pump, keep the coupler
off the ground so dirt and other debris will not build up in the
ball socket.
Check wheel mounting lug nuts with a torque wrench.
Torque wheel lug nuts as described in the "
Lug Nut Torque
Requirements
", Table 5.
Make sure brakes are synchronized and functioning properly.
Check tightness of suspension hardware (nuts and bolts).
Avoid sudden stops and starts. This can cause skidding, or
jackknifing. Smooth, gradual starts and stops will improve
gas milage.
Avoid sharp turns to prevent rolling.
Retract wheel stand when transporting.
DO NOT transport pump with fuel in the fuel tank.
If the trailer coupler is deformed replace entire coupler. NEVER
tow the pump with a defective trailer coupler. There exist the
possibility of the trailer separating from the towing vehicle.
Check with your county or state safety towing regulations
department before towing your concrete pump.
CAUTION - Local Towing Regulations
CAUTION -
Never Use Defective Couplers
MAYCO C30HDZ PUMP — OPERATION MANUAL — REV. #14 (01/12/21) — PAGE 13
TOWING GUIDELINES
Figure 2. Towing Applications
Figure 2 shown below illustrates the typical towing application
that should be used when towing the pump.
PAGE 14 — MAYCO C30HDZ PUMP — OPERATION MANUAL — REV. #14 (01/12/21)
TRAILER SAFETY GUIDELINES
This section is intended to provide the user with trailer service
and maintenance information. Remember periodic inspection of
the trailer will ensure safe towing of the equipment and will
prevent damage to the equipment and personal injury.
It is the purpose of this section to cover the major maintenance
components of the trailer. The following trailer components will
be discussed in this section:
Tires
Lug Nut Torquing
Suspension
Electrical
Trailer Safety Precautions
ALWAYS make sure that the trailer is in good operating condi-
tion. Check the tires for proper inflation and wear. Also check the
wheel lug nuts for proper tightness.
CAUTION -
General Trailer Safety
The following list defines the major trailer components:
1. Fuel Cell – Provides an adequate amount of fuel for the
equipment in use. Fuel cells must be empty when transport-
ing equipment.
2. Frame Length – This measurement is from the ball hitch to
the rear bumper (reflector).
3. Frame Width – This measurement is from fender to fender.
4. Jack Stand – Trailer support device with maximum pound
requirement from the tongue of the trailer.
5. Coupler – Type of hitch used on the trailer for towing. This unit
employes a 2 in. ball.
6. Tires Size – Indicates the diameter of the tire in inches (10,
12, 13, 14, etc. ), and the width in millimeters (175, 185, 205
etc.). The tire diameter must match the diameter of the tire rim.
This unit employes 7.35 x 14 in. tires.
7. Tires Ply – The tire ply (layers) number is rated in letters:
2-ply, 4-ply, 6-ply, 8-ply, 10-ply etc. This unit employes
4-ply tires.
8. Wheel Hub – The wheel hub is connected to the trailer's axle.
9. Tire Rim – Tires are mounted on a tire rim. The tire rim must
match the size of the tire.
10. Lug Nuts – Used to secure the wheel to the wheel hub.
Always use a torque wrench to tighten down the lug nuts. See
Table 5 and Figure 4 for lug nut tightening and sequence. This
unit employes 5 lug nuts to secure the wheel to the hub.
11. Axle – This trailer employs a torsion bar type suspension,
which can support 3,500 lbs.
12. Electrical – Electrical connectors (looms) are provided with
the trailer so that brake lights and turn signal lights can be
connected to the towing vehicle. See
Trailer Wiring Diagram
for proper wiring connections.
MAYCO C30HDZ PUMP — OPERATION MANUAL — REV. #14 (01/12/21) — PAGE 15
Tires/Wheels/Lug Nuts
Tires and wheels are a very important and critical components
of the trailer. When specifying or replacing the trailer wheels it is
important the wheels, tires, and axle are properly matched.
TRAILER SAFETY GUIDELINES
DO NOT attempt to repair or modify a wheel. DO NOT install
an inter-tube to correct a leak through the rim. If the rim is
cracked, the air pressure in the inter-tube
may cause pieces of the rim to explode
(break-off) with great force and can cause
serious eye or bodily injury.
ALWAYS
wear safety glasses when
removing or installing force fitted
parts. Failure to comply may result in
serious injury.
Figure 3. Major Suspension Components
Torsion Bar Suspension
The torsion bar suspension and associated hardware
(Figure 3) should be visually inspected every 6,000 miles for
signs of excessive wear, elongation of bolt holes, and loosening
of fasteners. Replace all damaged parts (suspension) immedi-
ately.
NOTE
Tires Wear/Inflation
Tire inflation pressure is the most important factor in tire life.
Pressure should be checked cold before operation. DO NOT
bleed air from tires when they are hot. Check inflation pressure
weekly during use to insure the maximum tire life and tread wear.
Table 3 (Tire Wear Troubleshooting) will help pinpoint the causes
and solutions of tire wear problems.
CAUTION -
General Trailer Safety
PAGE 16 — MAYCO C30HDZ PUMP — OPERATION MANUAL — REV. #14 (01/12/21)
Lug Nut Torque Requirements
It is extremely important to apply and maintain proper wheel
mounting torque on the trailer. Be sure to use only the fasteners
matched to the cone angle of the wheel. Proper procedure for
attachment of the wheels is as follows:
1. Start all wheel lug nuts by hand.
2. Torque all lug nuts in sequence (Figure 4). DO NOT torque
the wheel lug nuts all the way down. Tighten each lug nut in
3 separate passes as defined by Table 4.
3. After first road use, retorque all lug nuts in sequence. Check
all wheel lug nuts periodically.
TRAILER SAFETY GUIDELINES
NEVER!
use an pneumatic air gun
to tighten wheel lug nuts.
Figure 4. Wheel Lug Nuts Tightening Sequence
stnemeriuqeReuqroTeriT.5elbaT
eziSleehWssaPtsriF
SBL-TF
ssaPdnoceS
SBL-TF
ssaPdrihT
SBL-TF
"2152-0204-5356-05
"3152-0204-5356-05
"4152-0206-05021-09
"
5152-0206-05021-09
"6152-0206-05021-09
NOTE
MAYCO C30HDZ PUMP — OPERATION MANUAL — REV. #14 (01/12/21) — PAGE 17
NOTES
PAGE 18 — MAYCO C30HDZ PUMP — OPERATION MANUAL — REV. #14 (01/12/21)
OPERATION AND SAFETY DECALS
Figure 5. Operation and Safety Decals
Figure 5 display's the operation and safety decals as they appear on the concrete pump, should any of these decals become
damaged or unreadable, contact the Multiquip Parts Department for a replacement set.
1. Before setup and operation of this equipment, the designated operator
MUST read and completely understand the operating instruction manual.
2. Keep unauthorized and untrained people away from the machine during
operation.
3. Do NOT operate unit with engine cover open: rotating or moving parts will
cause serious injury. ( An automatic shutdown switch has been
installed on the hood to prevent this.
4. Engine must be shut off before servicing.
5. Keep hands out of hopper when engine is running.
6. Check hopper for obstructions before operating machine.
7. This machine is remotely controlled and may start at any time.
8. Stop the engine before adding fuel or oil.
CAUTION !
508594
LOW
NORMAL
Before starting engine, check that the oil level
inside the “ is within the indicated
operating range. Recommended oil type SAE 30.
LUBE BOX
1”
CAUTION
DCL 152
C-30HDZ
P/N 508594
P/N 513119
P/N DCL152
P/N EM1028
GREASE DAILY, EVERY ZERK
Use No. 2 Multipurpose Automotive Grease
MAINTENANCE
513165
P/N EM513165
NAMEPLATE
CONTACT PARTS DEPT.
P/N EM932
When the pump, manifold or delivery system
plugs, do not disconnect the delivery system
clamps or open the manifold. A plug has
occurred when the pump is running but no
concrete is discharging from the end of the
delivery system: immediately switch the engine
OFF consult your operatingadinstruction
manual before proceeding.
Great care must be taken to clear a plug
as a dangerous condition exist, due to high
pressure build-up, inside the pump and delivery
system.
CAUTION
932
OWNER’S MANUAL
P/N 34536
Refer to the owner’s manual for safe
operating procedures.
Welding on the main frame or other
components may void warranty.
Refer to owner’s manual for proper use
of the piston lubrication sytems.
Failure to utilize the rear stabilizer leg
while pumping could damage axle.
WARNING
98022
P/N 98022
quartz
310-537-3700
800-421-1244 NATIONWIDE
FAX: 310-537-3927
MAYCO INC 18910
WILMINGTON AVENUE CARSON,
CALIFORNIA 90746
513163
OIL PRESSURE
BATTERY
OIL
TEMPERATURE
PUMPING CONTROL
REMOTE
OUTLET
ENGINE HOURS
PUMP
ON
OFF REMOTE
ON
OFF
ON
START
IGNITION
SWITCH
THROTTLE
P/N 513163
MAYCO C30HDZ PUMP — OPERATION MANUAL — REV. #14 (01/12/21) — PAGE 19
IMPORTANT HAND SIGNALS
Figure 6. Operation Hand Signals
Figure 6 display's the basic hand signals commonly used in concrete pumping operations.
PAGE 20 — MAYCO C30HDZ PUMP — OPERATION MANUAL — REV. #14 (01/12/21)
PUMP COMPONENTS
Figure 7. Major Pump Components
7
12
8
9
10
MAYC0
C-30HDZ
24
1
3
5
6
15
17
21
20
11
22
2
4
18
19
23
25
16
14
13
/