Intratone EEN-BOXECO-LPC Installation guide

Type
Installation guide
EEN-BOXECO-LPC
: Installation guide
Page 1 / 2 EN-V231-0097-BA
W
IRING DIAGRAM
CENTRAL UNIT
EEN-LP-C
EEN-CIC-12
Cabling
Max 100m from power supply using twisted cable of 0.5 dia
Max 200m from power supply using twisted cable of 0.8 dia
12/24V
DC
-
2
A
MP
(NOT SUPPLIED)
As close as possible to the central unit
NEVER PUT THE EEN-MGPRS BLOCK IN A METAL BOX
The leds on the EEN-MGPRS block display the reception quality of the nearby GPRS network signal: "The
more leds lit up, the better the signal". For optimum performance, ensure that you have 3 leds lit up.
REMEMBER TO NOTE THE SERIAL NO. OF THE EEN-CIC12 CENTRAL UNIT.
You will need this together with the EEN-MGPRS contract no. in order to create your equipment on:
www.intratone.com in the "management website" tab
C
R
-
-
D+
D-
+
-
D+
D-
+
A
Pb
Door Relay
Pb: Door
A: Alert
EEN-MGPRS
-
D+
D-
+
Alert
EEN-BOXECO-LPC
: Installation guide
Page 2 / 2 V231-0097-BA
C
ABLING AND SETTINGS FOR A DOOR CONNECTED TO THE EEN
-
CIC
12
CENTRAL UNIT
M
AGNET LOCK
E
LECTRIC LOCK
S
WITCHES AND SETTINGS
The voltage of the electric magnet power supply or of the electric lock must be less than 42 V AC or
60 V DC. If the power supply voltage exceeds these values, use an intermediate relay (of the correct
capacity) to control the electric lock.
NOT
USED
S
S
1
1
NOT
USED
S
S
2
2
NOT
USED
S
S
3
3
**TIME
S
S
4
4
S
S
5
5
O
O
N
N
O
O
N
N
05 sec
O
O
N
N
O
O
F
F
F
F
10 sec
O
O
F
F
F
F
O
O
N
N
20 sec
TYPE OF
BUTTON
S6 ON NO OFF NC
Flashing SLOW LED OFF FAST
LED 1
Reader
Check power
Reader
LED 2
LED 3
Central unit
operational
Central unit with
factory settings
Memory
problem
LED 4
GSM
module
GSM module
LED 5
IMPORTANT:
Installation of the varistors supplied with the central unit ensures the system's proper functioning and longevity
1. The varistor must be fitted as close as possible to the electric lock or the magnet lock.
2. Open access times should be avoided in the case of doors fitted with electric locks!
3. The varistor is 12V.
IF YOU INSTALL SEVERAL POWER CABLES, ENSURE THAT GROUNDS (-) ARE ALL CONNECTED.
The complete pack for managing single-door access with
1 proximity reader (EEN-LP-C) 1 central management unit for 1 door (EEN-CIC12) 1 (EEN-MGPRS-DATA) module.
Door Push
Button
C R T
Power supply
Magnet lock
EEN-CIC12
Door Push
Button
C R T
Electric
lock
Power supply
Electric lock
EEN-CIC12
  • Page 1 1