1. Programming
1.1 General notes on programming
Advice:
As soon as the button P is pressed lon-
ger than 10 sec., the control unit
changes to the extended operator
functions.
Important factory settings can be
changed in this area.
Advice:
The control unit can only be program-
med after the reference point has been
passed 1x in OPEN direction and 1x in
CLOSE direction.
The programming of the operator is divided in two areas:
1. Programming of the basic level:
The basic functions of the operator are programmed
in this level. This programming process is carried out
consecutively and it is compulsory.
2. Programming of the extended operator functions:
The programming of the extended operator functions
consists of four levels. Changes in these levels may
only be carried out by specialist personnel.
This programming process is consecutive; several levels
can be skipped when pressing button P.
To come to the programming of the basic level, button P
must be pressed longer than 2 sec but less than 10 sec.
Programming is carried out with the buttons +, -, and P.
If none of the buttons is actuated within 120 sec. in
programming mode, the control unit changes back to
the operating mode.
An error message is displayed accordingly.
During this procedure following is displayed:
The operator is between the reference point
and the end position OPEN.
The operator is between the reference point
and the end position CLOSED.
Advice:
The control unit travels without
press-and-hold.
The "end position OPEN" and the "end position
CLOSED" can be programmed in two different ways:
1. Coarse adjustment by permanently holding a
button
The setting is carried out when button + or - is pressed
permanently.
The door travels correspondingly to the OPEN or
CLOSED position.
2. Fine adjustment by a short button impulse
The setting is carried out by a short button impulse
on button + or -. The door does not move during this
procedure.
Every time the button is pressed the end position is
shifted by 4 mm to the respective direction.
To test the end position, the door has to be travelled
over the reference point to the OPEN position or to the
CLOSED position.
During the button impulse the LED 7 is
flashing quickly.
Legend:
LED off
LED on
LED flashing slowly
LED flashing quickly
English - Page 3
1.
The control unit is in
menu 2 of the basic
programming.
2.
Set end position DOOR
CLOSED.
3.
The reference point
must be passed 1x.
4.
Fine adjustment is carried
out with impulse on
button + or -.
5.
Press button P 1x:
save the end position.
Automatic change to
the programming of
"power limit OPEN".
1.2.2 Programming of the "end position CLOSED"
1. Programming
1.
The control unit is in
operating mode.
2.
To change to the
programming mode
press button P:
> 2 Sec. < 10 Sec.
3.
Do not hold button P
longer than 10 sec.!
4.
The control unit is in
menu 1 of the basic
programming.
5.
Set the end position
DOOR OPEN.
6.
The reference point
must be passed 1x.
7.
Fine adjustment is carried
out with impulse on
button + or -.
8.
Press button P 1x:
save the end position.
9.
Automatic change to
the programming of the
"end position CLOSED".
1.2 Programming of the basic level
1.2.1 Programming of the "end position OPEN"
English - Page 4
1. Programming
1.2.3 Programming of the "power limit OPEN" 1.2.4 Programming of the "power limit CLOSE"
1.
The control unit is in
menu 3 of the basic
programming.
2.
Press button + 1x:
The current setting is
displayed.
3.
Set the power limit as
sensitive as possible.
4.
Press button + or -:
Setting in steps from 1
(sensitive) to 16.
5.
Press button P 1x:
save the set value.
6.
Automatic change to
the programming of the
"power limit CLOSE".
1.
The control unit is in
menu 4 of the basic
programming.
2.
Press button + 1x:
The current setting is
displayed.
3.
Set the power limit as
sensitive as possible.
4.
Press button + or -:
Setting in steps from
1 (sensitive) to 16.
5.
Press button P 1x:
save the set value.
6.
Automatic change to
the programming of the
"RC remote control".
Legend:
LED off
LED on
LED flashing slowly
LED flashing quickly
English - Page 5
1.
The first storage place is
selected.
2.
Press button + 1x:
The selected storage
place is ready to be
programmed.
3.
Press the respective
button on the hand
transmitter.
4.
Press button P 1x:
The coding of the hand
transmitter is saved.
5.
Change to the next
storage place.
Program the RC remote control
(example storage place 1)
Advice:
Wrongly programmed coding can be
overwritten with a new coding.
If necessary they can be deleted!
Function allocation of the storage places
You can read in up to 3 differently coded functions:
1.
The control unit is in
menu 5 of the basic
programming.
2.
Press button + 1x:
The first storage place is
selected.
3.
Press button P 1x:
The next storage place
is selected.
1.
Function Impulse
2.
Function OPEN
3.
Function CLOSE
1.2.5 Programming of the "RC remote control"
1. Programming
Select the programming of RC remote control
English - Page 6
1. Programming
1.
The first storage place is
selected.
2.
Press button - 1x:
The selected storage
place is ready to be
deleted.
3.
Press button P 1x:
The coding of the selec-
ted storage place is
deleted.
4.
Change to the next sto-
rage place.
Delete RC remote control - if necessary
(example storage place 1)
Finish the programming of the RC remote control
1.
Press button P until the
third storage place is
selected.
2.
Press button P 1x:
The programming of RC
remote control is termi-
nated.
3.
The control unit changes
to the programming
"reset factory settings".
4.
Press button P 1x:
The programming of the
basic level is terminated.
5.
The control unit is in
operating mode.
Legend:
LED off
LED on
LED flashing slowly
LED flashing quickly
English - Page 7
1.2.6 Programming of "reset factory settings"
1. Programming
With the reset function all menus can be reset to the
values already set from factory.
1.
The control unit is in
operating mode.
2.
To change to the
programming mode:
press button P:
> 2 Sec. < 10 Sec.
3.
Do not hold button P
longer than 10 sec.!
4.
Press button P 5x to
get to the menu
"reset factory settings".
5.
Press button + or - 1x:
Selection "no reset" -
all set values remain
unchanged.
6.
Press button - or + 1x:
Selection "reset" -
factory settings are
restored.
7.
Press button P 1x:
Save and terminate
programming.
8.
New start when RESET
has been selected:
All LED's glow up for
2 sec.
9.
The control unit is in
operating mode.
Legend:
LED off
LED on
LED flashing slowly
LED flashing quickly
English - Page 8
1.3.1 Overview of the extended operator functions
Level Functions Explanation Factory settings
3rd programming
level
Automatic timer
function
Open door time The time the door is open before it closes automatically.
Automatic timer
function deactivated
Warning time
The time the signal light is flashing before the door
closes automatically.
Automatic timer
function deactivated
Warning before start
The time the signal light flashes before the door starts
to move.
0 seconds
Early closing after having
passed the photocell
The door closes either after the set open time or earlier
after having passed the photocell.
No
Signal lights
The signal light function can be set to flashing or to
permanent light.
Flashing light
4th programming
level
Parameter
Excess travel stop
The time period after which the operator cuts out
without having reached an end position.
55 seconds
Offset learned power limit The learned power limit can be set in steps from 1 - 16. Step 4
Sensitivity power limit
The sensitivity of the power limit can be set in steps
from 1 - 16.
Step 13
6th programming
level
Reversion
modes
Power limit OPEN
Setting whether the operator stops, short or long
reversion.
Stop
Power limit CLOSE
Setting whether the operator stops, short or long
reversion.
Stop
Activation of photocell /
photocell CLOSE
Setting whether the operator stops, short or long
reversion.
not existing
Closing edge safety device
CLOSE
Setting whether the operator stops, short or long
reversion.
short reversion
8th programming
level
Operating
modes
Press-and-hold OPEN After start the operator runs to the selected position. On
Press-and-hold CLOSE After start the operator runs to the selected position. On
Impulse commands
Activation of the impulse button when the operator
runs.
No
Direction commands
(Pushbutton OPEN or CLOSE)
Activation of the direction button when the operator
runs.
Yes
1. Programming
1.3 Extended operator functions (only for specialist personnel)
English - Page 9
1. Programming
1.3.2 Programming sequences of the extended
operator functions
1.
The control unit is in
operating mode.
2.
Press button P:
> 10 Sec.
Countdown from 8 to
1, then all LED's are on.
3.
Release button P:
The control unit is in the
first level of the extended
operator functions.
4.
Press button P 1x:
Change to the next
level of the extended
functions.
5.
Press button + 1x:
Change to the first
menu of the selected
level.
6.
Press button + 1x:
Display of the current
setting.
7.
Press button + or -:
Change the current
value.
8.
Press button P 1x:
Save the value, display
of the selected level.
9.
If P is pressed without
changing the value,
the setting remains
unchanged!
10.
Press button P 1x:
Change to the next
menu in the selected
level.
11.
After the last
programming menu of
the selected level the
control unit displays the
selected level.
12.
Press button P 1x:
The control unit
changes to the next
level.
13.
After the last
programming level the
programming of the
extended operator
functions is terminated.
14.
Press button P 1x:
The programming is
terminated.
15.
The control unit is in
operating mode.
Legend:
LED off
LED on
LED flashing slowly
LED flashing quickly
English - Page 10
1. Programming
1.3.3 Programming of the extended operator functions
Level 3: Automatic timer function
<- button button + ->
16
Menu 1: Open door time
255
Seconds
Menu 2: Warning time
70
Seconds
Menu 3: Warning before start
Menu 4: Early closing after having passed the photocell
Menu 5: Signal lights
15
180
Seconds
65
Seconds
14
150
Seconds
60
Seconds
13
120
Seconds
55
Seconds
12
100
Seconds
50
Seconds
11
80
Seconds
45
Seconds
10
50
Seconds
40
Seconds
9
40
Seconds
35
Seconds
8
35
Seconds
30
Seconds
7
Seconds
7
30
Seconds
25
Seconds
6
Seconds
6
20
Seconds
20
Seconds
5
Seconds
5
25
Seconds
15
Seconds
4
Seconds
4
15
Seconds
10
Seconds
3
Seconds
3
10
Seconds
5
Seconds
2
Seconds
2
5
Seconds
2
Seconds
1
Seconds
YES
flashing
light
1
Automatic
timer
function
deactivated
Automatic
timer
function
deactivated
0
Seconds
NO
permanent
light
<- button P
Legend:
LED off
LED on
LED flashing slowly
LED flashing quickly
Setting from factory
Not possible
English - Page 11
1. Programming
1.3.3 Programming of the extended operator functions
Level 4: Parameter
<- button button + ->
16
Menu 1: Excess travel stop
220
Seconds
Menu 2: Offset learned power limit
16
Menu 3: Sensitivity power limit
16
15
220
Seconds
15
15
14
210
Seconds
14
14
13
200
Seconds
13
13
12
190
Seconds
12
12
11
180
Seconds
11
11
10
160
Seconds
10
10
9
140
Seconds
9
9
8
120
Seconds
8
8
7
100
Seconds
7
7
6
80
Seconds
6
6
5
65
Seconds
5
5
4
55
Seconds
4
4
3
50
Seconds
3
3
2
40
Seconds
2
2
1
30
Seconds
1
1
<- button P
Legend:
LED off
LED on
LED flashing slowly
LED flashing quickly
Setting from factory
Not possible
English - Page 12
1. Programming
1.3.3 Programming of the extended operator functions
Level 6: Reversion modes
<- button button + ->
16
Menu 1: Power limit for OPEN direction
Menu 2: Power limit for CLOSE direction
Menu 4: Activation of photocell / photocell for CLOSE direction
Menu 6: Closing edge safety device for CLOSE direction
15141312111098
7
65
4
not
existing
not
existing
not
existing
not
existing
3
long
reversion
long
reversion
long
reversion
long
reversion
2
short
reversion
short
reversion
short
reversion
short
reversion
1
Stop
Stop
Stop
Stop
<- button P
Legend:
LED off
LED on
LED flashing slowly
LED flashing quickly
Setting from factory
Not possible
English - Page 13
1. Programming
1.3.3 Programming of the extended operator functions
Level 8: Operating modes
<- button button + ->
16
Menu 1: Press-and-hold for OPEN direction
Menu 2: Press-and-hold for CLOSE direction
Menu 3: Impulse - command device active when operator runs
Menu 4: OPEN/CLOSE command device active when operator runs
15141312111098
7
65
43
2
ON
ON
YES
YES
1
OFF
OFF
NO
NO
<- button P
Legend:
LED off
LED on
LED flashing slowly
LED flashing quickly
Setting from factory
Not possible
English - Page 14
2.1 Display of the messages
Messages at permanent actuation
When actuating operating and safety elements
permanently the current status of the system is
displayed.
1.
The control light
MALFUNCTION (6)
glows.
2.
Press button P 1x:
Display of the status
(see below).
1.
The control light
MALFUNCTION (6) is
flashing.
2.
Press button P 1x:
Display of the error
number (see 10.2).
Messages at malfunctions
Malfunctions in the system are displayed by a
corresponding error number.
1.
Press button P:
The LED's from
1 - 8 are glowing.
2.
The control unit shows
the current messages.
3.
Press button -:
Old messages are
displayed.
4.
Press button +:
The current message is
displayed.
5.
Press button P:
The display of the
message memory is
finished.
6.
The control unit is in
operating mode.
Message memory
The message memory displays the last 5 messages of
the control unit.
Status displays
IMPULSE button actuated
OPEN button actuated
Closing edge safety device OPEN actuated
CLOSE button actuated
Closing edge safety device CLOSE actuated
Photocell actuated
Static current circuit interrupted
2. Messages
English - Page 15
2. Messages
2.2 Overview of the error numbers
Number Message Display
6 Photocell actuated
7 Programming cancelled
8 Reference point
9 R.P.M sensor defective
10 Power limit
11 Excess travel stop
12
Testing
closing edge safety device
OPEN not o.k.
13
Testing
closing edge safety device
CLOSE not o.k.
15
Testing
photocell not o.k.
Number Message Display
16 Testing power limit
27 Sensitivity power limit
28
Offset learned
Power limit
36
Static current circuit
interrupted
Legend:
LED off
LED on
LED flashing slowly
LED flashing quickly
English Copyright.
No part of this manual may be reproduced without our prior approval.
Subject to alterations in the interests of technical progress.
Version: 10.2004
#71 791
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Marantec Control 25N Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI