True TUI15LSSB Installation guide

  • Hello! I am an AI chatbot trained to assist you with the True TUI15LSSB Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
IN DEX
TRUE RESIDENTIAL
®
15 INCH CLEAR ICE MACHINE MODELS
INSTALLATION GUIDE AND USER’S MANUAL
As a family-owned business, we believe in the importance of service,
so we’ve always made sure that good help isnt hard to find, whether
that means providing design inspiration or product information. For 70
years, we’ve been pioneers in cold, but we’ve also been leaders in warm
customer service and support. We hope that this guide offers you what
you need for the True Residential
®
products in your customers’ (or your
own) homes. If you don’t see what you’re looking for, please contact True
customer service at 888-616-8783 or info@true-residential.com or you
may also visit our website at true-residential.com
Commercial refrigeration refined for the home, envied in the industry,
and craftedgorgeouslyin America.
INSTALLATION CHECKLIST 1
15 INCH TRUE
ICE
TM
MACHINE MODELS 3
FEATURES OF THE TRUE ICE
TM
MACHINE 6
OWNERSHIP 6
SAFETY PRECAUTIONS 6
PROPER DISPOSAL AND CFC DISPOSAL 7
WARNING & SAFETY LABELS 7
UNCRATING 8
ELECTRICAL SPECIFICATIONS 9
INSTALLATION SPECIFICATIONS 12-16
OVERLAY PANEL INSTALLATION 17-18
INSTALLING DOOR STOP 19
PLUMBING CONNECTIONS 19
LEVELING ICE MACHINE 20
WATER SUPPLY 20
DRAIN CONNECTION 21
WATER FILTER 22
POSITION THE UNIT 22
PUMPING HEIGHTS 23-24
DRAIN ALARM (DRN) 25
TRUE PRECISION CONTROL
®
OPERATION AND TRUE ICE™ MACHINE COMPONENTS 27
BEFORE OPERATING 28
ICE MAKING SEQUENCE 29
POWER AND BIN LIGHT 30
CUBE SIZE ADJUSTMENT 30
BIN THERMOSTAT / ICE LEVEL ADJUSTMENTS 31
BREAKER RESET 31
WATER QUALITY SETTING 31
GENERAL MAINTENANCE 34
WATER SHUTTERS, ICE CHUTE, AND PUMP CLEAN-OUT CAP 35
SPRAY BAR DISASSEMBLY 36
WATER FILTER REPLACEMENT AND REPLACEMENT PARTS 37
CONDENSER CLEANING INSTRUCTIONS 37
STAINLESS STEEL EQUIPMENT CARE AND CLEANING 38
DESCALING AND SANITIZING 38-39
EXTERIOR CLEAN, WINTERIZING AND RESTART INSTRUCTIONS 39
FREQUENTLY ASKED QUESTIONS 41
WARRANTY 42-43
C ON T EN T S
1
15 INCH TRUE
ICE
TM
MACHINE INSTALL GUIDE
INSTALLATION CHECKLIST
Use this checklist during installation to ensure that no part of the process has been overlooked.
Has an authorized True dealer or licensed installer inspected stainless steel surfaces for imperfection?
(Cosmetic defects are covered by a limited 30-day warranty)
Have all packaging materials and tape been removed?
Is the water temperature always between 40˚F (C) and 100˚F (38˚C)?
Is the power cord plugged into a properly grounded three-prong outlet in accordance
with all applicable electrical codes?
Have the water supply and drain connections been made?
Has the ice machine drain line been routed into an open drain with no more than eight feet (2.4 m) of rise
and 100 feet (33 m) of run?
Is the unit leveled properly with all leveling legs making contact with the floor?
Has the door stop been installed? (If required)
Are panels attached securely and properly aligned? (Overlay cabinets only)
Has the machine been set for the local water quality?
Has the water filter been installed?
Is the water supply turned on?
Have the connections been checked for water leaks?
Is the machine turned on and working properly?
Have the first two batches of ice been discarded?
Does the machine shut off when ice is held against the thermostat tube?
Has the customer reviewed the unit’s operation in this manual?
Has the customer reviewed the schedule of maintenance of the machine?
2
TRUE RESIDENTIAL
®
3
15 INCH TRUE
ICE
TM
MACHINE INSTALL GUIDE
SOLID PANEL READY DOOR (OP)
15 INCH TRUE
TM
ICE MACHINE
TUI-15-R/L-OP-B
15 INCH OVERLAY PANEL
STAINLESS STEEL DOOR (SS)
15 INCH TRUE
TM
ICE MACHINE
TUI-15-R/L-SS-B
15 INCH STAINLESS STEEL
4
TRUE RESIDENTIAL
®
5
15 INCH TRUE
ICE
TM
MACHINE INSTALL GUIDE
5 - 9
FEATURES OF THE ICE MACHINE
OWNERSHIP
SAFETY PRECAUTIONS
PROPER DISPOSAL AND CFC DISPOSAL
WARNING & SAFETY LABELS
UNCRATING
ELECTRICAL SPECIFICATIONS
6
TRUE RESIDENTIAL
®
FEATURES OF THE TRUE™ ICE MACHINE
Produces up to 70 pounds of ultra-clear gourmet
ice cubes per day.
Stores 28 pounds of ice cubes.
Three-Character LED display tells you what your
machine is doing.
Auto-clean sequence for walk-away cleaning
simplicity.
Cleaning time remaining is shown on the display.
Drain pump standard on all models.
Built-in water filter insures that no parts are
exposed to unfiltered water.
Fourteen-Color LED bin light.
High quality ice scoop and built-in scoop holder
included.
Automatic filter change reminder.
UL approved for outdoor use.
Industry-leading True Warranty on page 42.
OWNERSHIP
TO INSURE THAT YOUR UNIT WORKS PROPERLY
FROM THE FIRST DAY, IT MUST BE INSTALLED
PROPERLY.
NOTE: WE HIGHLY RECOMMEND A TRAINED
INSTALLER, PLUMBER OR ELECTRICIAN INSTALL
YOUR TRUE RESIDENTIAL
®
ICE MACHINE. THE
COST OF A PROFESSIONAL INSTALLATION IS
MONEY WELL SPENT.
Before you start to install your True Residential
®
Ice
Machine, carefully inspect it for freight damage. If
damage is discovered, immediately file a claim with
the delivery freight carrier. True is not responsible for
damage incurred during shipment.
Any questions about the installation please
contact your True dealer or True Technical Service
Department at 844-746-9423. Please have your
model and serial numbers available when you call our
Service Department.
SAFETY PRECAUTIONS
This ice machine must be properly installed
and located in accordance with the installation
instructions before it is used.
Do not allow children to climb, stand or hang
on the ice machine. They could damage the ice
machine and seriously injure themselves.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
Keep hands away from the “pinch point” areas and
gaps between the doors and cabinet. Small areas
are not necessarily safe.
Unplug the ice machine before cleaning behind
the kickplate or making repairs.
Setting power switch to OFF only removes power
from the refrigeration system, it does not remove
power from other circuits. To fully power-down the
machine it must be unplugged.
NOTE: WE STRONGLY RECOMMEND
THAT ANY SERVICING BE PERFORMED
BY A QUALIFIED INDIVIDUAL.
WARNING: PROPER INSTALLATION REQUIRES
CONNECTION TO THE WATER SUPPLY, A DRAIN
AND A DEDICATED ELECTRICAL CIRCUIT. THESE
CONNECTIONS ARE THE RESPONSIBILITIES OF
THE INSTALLER. IMPROPER CONNECTIONS CAN
RESULT IN PERSONAL INJURY, PROPERTY DAMAGE
AND IMPROPER OPERATION. THE ICE MACHINE
MUST BE INSTALLED ACCORDING TO ALL
APPLICABLE NATIONAL, STATE AND LOCAL
CODES AND REGULATIONS.
7
15 INCH TRUE
ICE
TM
MACHINE INSTALL GUIDE
PROPER DISPOSAL OF
THE OLD ICE MACHINE
Child entrapment and suffocation are not problems
of the past. Junked or abandoned ice machines are
still dangerous, even if they will sit for “just a few
days.” If you are getting rid of your old ice machine,
please follow the instructions below to help prevent
accidents.
BEFORE YOU THROW AWAY YOUR OLD ICE MACHINE, TAKE
OFF THE DOORS.
CFC DISPOSAL
Your old ice machine may have a cooling system that
used CFCs (chlorofluorocarbons). CFCs are believed
to harm stratospheric ozone. If you are throwing away
your old ice machines, make sure the CFC refrigerant
is removed for proper disposal by a qualified service.
If you intentionally release this CFC refrigerant you
can be subject to fines and imprisonment under
provisions of the environment legislation.
WARNING & SAFETY LABELS
CAUTION:
Located on the
back of the unit.
WARNING:
Located on the
back of the unit.
NOTICE:
Behind front
door next to
water filter.
Do not operate without a lter installed. Replace
lter annually. Reset “FLT” reminder by holding
CLEAN and LIGHT buttons for 5 seconds.
No opere sin el ltro instalado. Reemplace el
ltro una vez al año. Reinicie el recordatorio
“FLT” manteniendo presionados los botones
CLEAN y LIGHT por 5 segundos.
8
TRUE RESIDENTIAL
®
UNCRATING
Required Tools:
Cutting utensil (utility knife)
Hammer
• Crowbar
Phillips screwdriver
INSPECT FOR CONCEALED DAMAGE. AGAIN,
IMMEDIATELY FILE A CLAIM WITH THE FREIGHT
CARRIER IF THERE IS DAMAGE.
The following procedure is recommended for
uncrating the unit:
Move your unit as close to the final location as
possible before removing the wooden skid.
A. Remove staples securing cardboard box to the
wooden skid. Then discard any outer packaging
(cardboard, clear plastic). Cut off all strapping.
B. IMPORTANT: Remove Styrofoam block before
removing ice machine from pallet.
C. Remove skid by carefully lifting the ice machine
off and place skid aside.
D. Open the unit and remove any packing material.
Styrofoam, tape, and any other material used for
shipping purposes.
E. Remove kickplate located inside ice bin. The
kickplate attaches to the front of the ice machine
with magnets.
PACKING MATERIAL
KICKPLATE INSTALLED
A
B
C
D
REMOVE KICKPLATE
FROM ICE BIN
E
9
15 INCH TRUE
ICE
TM
MACHINE INSTALL GUIDE
ELECTRICAL SPECIFICATIONS
WARNING: THIS APPLIANCE MUST BE PROPERLY
GROUNDED. DO NOT, UNDER ANY CIRCUMSTANCES,
CUT OR REMOVE THE THIRD (GROUND) PRONG
FROM THE POWER CORD. FOR PERSONAL SAFETY,
THIS APPLIANCE MUST BE PROPERLY GROUNDED.
The electrical outlet must be within three feet of
the center of the back wall of the ice maker’s final
location. Outlet must be flush with wall and comply
with local electrical codes.
Before your new unit is connected to a power supply,
check the incoming voltage with a volt meter. If
anything less than 100% of the rated voltage for
operation is noted, correct immediately.
The power cord of this appliance is equipped with
a three-prong (grounding) plug which mates with
a standard three-prong (grounding) wall outlet to
minimize the possibility of electric shock hazard from
this appliance. A 115V AC, 60 Hz, 15 amp circuit
breaker and electrical supply are required.
Have the wall outlet and circuit checked by a qualified
electrician to make sure the outlet is properly
grounded.
If the outlet is a standard
two-prong outlet, it is your personal
responsibility and obligation to have
it replaced with the properly
grounded three-prong wall outlet.
Do not use an extension cord or
two-prong adaptor. Electrical ground
is required on this appliance.
The unit should always be plugged into its own
individual electrical outlet which has a voltage rating
that matches the rating plate. This provides the best
performance and also prevents overloading house
wiring circuits which could cause a fire hazard from
overheated wires. Never unplug your ice machine by
pulling on the power cord. Always grip plug firmly and
pull straight out from the outlet.
Repair or replace immediately all power cords that
have become frayed or otherwise damaged. Do not
use a cord that shows cracks or abrasion damage
along its length or at either end. When moving the ice
machine away from the wall, be careful not to roll over
or damage the power cord.
The unit is approved by UL for outdoor installation.
10
TRUE RESIDENTIAL
®
11
15 INCH TRUE
ICE
TM
MACHINE INSTALL GUIDE
11 - 25
INSTALLATION SPECIFICATIONS
OVERLAY PANEL INSTALLATION
INSTALLING DOOR STOP
PLUMBING CONNECTIONS
LEVELING ICE MACHINE
WATER SUPPLY
DRAIN CONNECTION
WATER FILTER
PUMPING HEIGHTS
DRAIN ALARM (DRN)
12
TRUE RESIDENTIAL
®
TOP
VIEW
SIDE
VIEW
FRONT
VIEW
ICE MACHINE TUI-15-R/L-SS-B
23
7/8
"
1
½
"
14
7/8
"
34
¼
"
37
7/8
"
16
¼
"
30
3
11/16
"
4
3/16
"
Dimensions may vary by ± 1/8"
25
¾
"
SURROUNDING CABINETRY
SURROUNDING CABINETRY
15 INCH STAINLESS STEEL
TOP VIEW
OF
ICE MACHINE
SIDE VIEW
OF
ICE MACHINE
FRONT
VIEW
OF
ICE MACHINE
A
B
C
13
15 INCH TRUE
ICE
TM
MACHINE INSTALL GUIDE
CAUTION: DO NOT ALLOW THE ICE MACHINE
TO BE EXPOSED TO TEMPERATURES
BELOW 32°F (C) AS THIS WILL CAUSE
ANY WATER IN THE MACHINE TO FREEZE.
FAILURES CAUSED BY EXPOSURE TO
FREEZING TEMPERATURES ARE NOT
COVERED BY THE WARRANTY.
INSTALLATION SPECIFICATIONS - STAINLESS SOLID DOOR
True’s Stainless Solid Door units are designed to be inserted into a cabinet opening or free standing.
Below are recommended minimum dimensions for rough opening.
Avoid running
wires or
plumbing in
this area.
SURROUNDING CABINETRY
SURROUNDING CABINETRY
9"
16"
11
½
"
FRONT
VIEW OF
CABINETRY
OPENING
BACK VIEW
OF
ICE MACHINE
* Max Ice Production 70 lbs/day
** Rated Ice Production 57 lbs/day
* Performance Rated at 70°F air / 50°F water / 30 psig water pressure.
**
Performance Rated at 90°F air / 70°F water / 30 psig water pressure.
ALLOWABLE TEMPERATURES AND PRESSURES
MINIMUM MAXIMUM
AIR TEMPERATURE 40˚ F 4˚ C 100˚ F 38˚ C
WATER TEMPERATURE 40˚ F 4˚ C 100˚ F 38˚ C
WATER PRESSURE
20
PSI
1.4
BAR
80
PSI
5.5
BAR
ROUGH
OPENING
DEPTH
24" (min.)
ROUGH
OPENING
WIDTH
15"(min.)
TOP VIEW
OF UNIT
BETWEEN
CABINETRY
14
TRUE RESIDENTIAL
®
ICE MACHINE TUI-15-R/L-OP-B
15 INCH OVERLAY PANEL
NOTE: UNIT IS SHOWN WITH OPTIONAL PANEL / HANDLE PROVIDED BY OTHERS.
TOP VIEW
OF
ICE MACHINE
SIDE VIEW
OF
ICE MACHINE
FRONT
VIEW
OF
ICE
MACHINE
23
7/8
"
¾
"
23
1/8
"
14
7/8
"
34
¼
"
16
¼
"
29
¾
"
*3
¾
"
4
1/8
"
21
5/8
"
SURROUNDING CABINETRY
SURROUNDING CABINETRY
1
½
"
A
B
C
Dimensions may vary by ± 1/8"
*Including 3/4" thick panel (provided by others)
15
15 INCH TRUE
ICE
TM
MACHINE INSTALL GUIDE
CAUTION: DO NOT ALLOW THE ICE MACHINE
TO BE EXPOSED TO TEMPERATURES
BELOW 32°F (C) AS THIS WILL CAUSE
ANY WATER IN THE MACHINE TO FREEZE.
FAILURES CAUSED BY EXPOSURE TO
FREEZING TEMPERATURES ARE NOT
COVERED BY THE WARRANTY.
INSTALLATION SPECIFICATIONS - SOLID PANEL READY
True’s Solid Panel Ready Door units are designed to be inserted into a cabinet opening or free standing.
Below are recommended minimum dimensions for rough opening.
Avoid running
wires or
plumbing in
this area.
SURROUNDING CABINETRY
SURROUNDING CABINETRY
9"
16"
11
½
"
FRONT
VIEW OF
CABINETRY
OPENING
BACK VIEW
OF
ICE MACHINE
* Max Ice Production 70 lbs/day
** Rated Ice Production 57 lbs/day
* Performance Rated at 70°F air / 50°F water / 30 psig water pressure.
**
Performance Rated at 90°F air / 70°F water / 30 psig water pressure.
ALLOWABLE TEMPERATURES AND PRESSURES
MINIMUM MAXIMUM
AIR TEMPERATURE 40˚ F 4˚ C 100˚ F 38˚ C
WATER TEMPERATURE 40˚ F 4˚ C 100˚ F 38˚ C
WATER PRESSURE
20
PSI
1.4
BAR
80
PSI
5.5
BAR
ROUGH
OPENING
DEPTH
24" (min.)
ROUGH
OPENING
WIDTH
15"(min.)
TOP VIEW
OF UNIT
BETWEEN
CABINETRY
/