FITTING INSTRUCTIONS
BUFFER GL500-8, GL500-10-2”, GL800-8, GL800-10-2.5” & GL1000-8
Fitting instructions
7783006 - 400mm CORREX POWERED ANODE KIT
THE INTRODUCTION OF THIS KIT HAS THREE MAIN ADVANTAGES TO BE CONSIDERED:
• LowMaintenanceCosts(Correxisnon-sacricial,thereforenoanodemaintenanceisneeded)
• LowRunningCosts(Lessthan35kWHperyear)
• Increasedprotection(particularlyinareasoflowelectricalconductivity).
MainselectricalsupplywiringtothewaterheatermustbeinstalledinaccordancewiththecurrentBuildingRegulationsinforceandBS7671
-RequirementsforElectricalInstallations.
iskitisdesignedtousea220/240V1ph50Hzpermanentsupply.efuseratingis3Amp.
emethodofconnectiontothemainselectricalsupplyshouldfacilitatecompleteelectricalisolationoftheCorrexkitandtheappliance.
epointofconnectiontothemainsshouldbereadilyaccessibleandadjacenttotheappliance.
Andrews. Built to perform.
Please read and understand these instructions before commencing installation and leave this manual with the customer for future reference.
INSTALLATION AND SERVICE MANUAL
Cylinders and Buffers
Stainless Steel 316 Storage Cylinders, Twin and Single Coil
STOR-SS300-8-S, STOR-SS500-8-S, STOR-SS800-8-S, STOR-SS1000-8-S,
STOR-SS300-8-T, STOR-SS500-8-T, STOR-SS800-8-T, STOR-SS1000-8-T
FIG 1
Correxanodereplaces
magnesiumanode
Potentiostat
&bracket
240V
permanent
supply
Outputlead
Outputlead
anode
connection
EarthM10
ringterminal
connection
Step 1
To install the Correx kit (refer to Fig1 diagram)
1. Draindownthebuffertank.
2. Removetheexistingmagnesiumanode.
3. Fitthecorrexanodeintotheconnection.
4. Fixthepotentiostattothebuffertankcasingusing
theretainingbracketprovided.
5. Connectthepotentiostatoutputleadontothe
anodeconnection.Achievethisbycuttingthe
leadtothedesiredlengthandusingthecrimp
typefemaleconnectorprovided.
6. Accessthetopconnectionofthetankbylifting
topcovertorevealM10nuts.RemoveoneM10nut
andconnecttheearthreturnatthispoint,bycut-
tingtheleadtothedesiredlengthandusingthe
crimptypeM10ringterminalconnectorprovided.
Replaceandre-tightentheM10nut.
7. Connectthepotentiostatmainscabletoaperma-
nent220/240V1ph50Hzelectricalsupplyviaan
unswitchedspuroutlet(fuserating3A).
Step 2
Test the installation
1. Rellthebuffertankandcheckforleaks.
2. Switchontheelectricalsupplytothepotentiostat.
3. egreenlamponthepotentiostatindicatesthat
theinstallationisfunctioningcorrectly.
4. eredlamponthepotentiostatindicatesafault.
Switchofftheelectricalsupplybeforeanyworkis
carriedout.
e installation is now complete.
7783006–400mmCorrexPoweredAnodeKitPackContents
Qty Part
17783007–400mmCorrexPoweredAnode
1 C995 – Potentiostat
1E049–EarthStrap
1Packofaccessories