Roche cobas u 601 User manual

Category
Microscopes
Type
User manual

This manual is also suitable for

Roche cobas u 601 is a urine analyzer that offers comprehensive and accurate urine analysis in a user-friendly package. With its simplified workflow and intuitive interface, you can easily perform a wide range of urine tests, such as dipstick and microscopy, on a single platform. cobas u 601 also features automated functions like sample dilution and reagent dispensing, reducing manual steps and minimizing the risk of errors.

Roche cobas u 601 is a urine analyzer that offers comprehensive and accurate urine analysis in a user-friendly package. With its simplified workflow and intuitive interface, you can easily perform a wide range of urine tests, such as dipstick and microscopy, on a single platform. cobas u 601 also features automated functions like sample dilution and reagent dispensing, reducing manual steps and minimizing the risk of errors.

cobas
®
6500 urine analyzer series
Software Flow Chart
c
COBAS, COBAS U and LIFE NEEDS ANSWERS
are trademarks of Roche.
Manufactured in Hungary
for Roche Diagnostics GmbH
© Roche Diagnostics. All rights reserved.
Roche Diagnostics GmbH
Sandhofer Strasse 
 Mannheim
Germany
www.cobas.com
0 6999328018 (03) 2016-07 EN
cobas
®
6500 urine analyzer series (software version 2.2.3 and higher)
AdministrationAssistance
Online help
Log on
About
Routine
Manage patients
Manage sample orders
• Delete
• Report
• Create
• Edit
• Delete
• Create
• Edit
• Comment
• Testprole
• Status
Patient assignment
Sample details
Patient assignment
Show rules
Show images
Manage test results
• Delete
• Report
• Send
• Rerun
• Validate
Review QC results
Manage QC materials
Manage QC
• Delete
• Report
• Edit
• Comment
• Delete
• Activate/deactivate
• Copy
• Create
• Edit
QC chart
Manage ranges
Overview
• Start
• Stop
• Stand by
• Shut down
• E. Stop
• Priority rack **
View messages
Manage test results
Manage sample orders
Manage supplies
Overview (hardware)
Tasks
• Hardware element status
• Due tasks
u601
Initialize system
Perform air purge
• Hardware element status
• Due tasks
u701
Initialize system
Perform air purge
Monitoring
View messages
Check microscope
Manage supplies
Systemwateru701
Cuvette
Solidwasteu701
Liquidwasteu701
Analyzer
Perform maintenance
Manage racks
• Delete
• Create
• Edit
• Rack ID
• Assignment (rack type)
• Rack position
Rack ID assignment
u601
• Hardware element status
• Due tasks
Initialize system
Perform air purge
u701
• Hardware element status
• Due tasks
Initialize system
Perform air purge
Systemwateru601
Test strip
Solidwasteu601
Liquidwasteu601
Manage calibrations
Calibrate photometer
Calibrate measuring cell
*
User management
System settings
Systemconguration
Result presentation
settings
Validation
Cross-check rules
General
Format particle label
Select measurement units
Change test result order
Change test result order
in report
Measurement settings
• Database limits for samples
• Sample ID (generation mode)
• Multiple measurements
Basicconguration1
• System name
• Language selection
• Password mode
• Alarm sound
• Virtual keyboard
• Automatic logoff
Basicconguration2
• Enable screen sharing
• Enablequantitativevaluesonu701
• Lower measurement limit
• Regional settings
• Change date and time settings
• Racktransport-onlymodeonu601
• Racktransport-onlymodeonu701
Reportconguration
• Report header
• Printer settings
• Report creation
• Image copy
Versions
Import or export system
settings
• Import system settings
• Export system settings
• Report system settings
Installation
• Install language
Hostconguration
• Enable host connection
• Enable raw data transmission
• Set up host connection
• Host protocol version
Barcodeconguration
• Enable checksum
• Enable check of length
Warning intervals
• Expiration
• Maintenance
• Preventive maintenance
Audit trail
Message log
Defaulttestprole
QC settings
• Number of QC levels
• Active range table
Rangetableconguration
Limitconguration
Colorrangeconguration
u601
• Warning limits for test strips
Rangetableconguration
Limitconguration
Particleconguration
u701
• Active range table
• Warning limits for cuvettes
• Microscopy images
Wizardsu601
Exchange probe
Fill water container
Exchange test strip
cassette
Empty solid waste
container
Empty liquid waste
container
Calibrate photometer
Adjust racks and tubes
Wizardsu701
Exchange probe
Fill water container
Exchange cuvette cassette
Empty solid waste
container
Empty liquid waste
container
Check microscope
Adjust racks and tubes
System statistic
Create problem report
Export screenshots
Initialize system
Back up database
Restore database
Export data in CSV format
Perform wash
Unload racks
• Include failsafe photometer
images
• Create anonymized database
backup
Manage sample sequence
numbers ***
Available only with Sample sequence number mode
***
All users can view the settings
*
Item, function summary
• Item
Panel on same screen
Item
To new screen, panel, or callout
Item
Available to all users
Available to users with Supervisor rights only
Available only with input connection unit
**
  • Page 1 1
  • Page 2 2

Roche cobas u 601 User manual

Category
Microscopes
Type
User manual
This manual is also suitable for

Roche cobas u 601 is a urine analyzer that offers comprehensive and accurate urine analysis in a user-friendly package. With its simplified workflow and intuitive interface, you can easily perform a wide range of urine tests, such as dipstick and microscopy, on a single platform. cobas u 601 also features automated functions like sample dilution and reagent dispensing, reducing manual steps and minimizing the risk of errors.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI