PowerWalker VFD 1000 (CEE 7/3) Owner's manual

Category
Uninterruptible power supplies (UPSs)
Type
Owner's manual

This manual is also suitable for

O
ffline(Standby)UPS
PowerWalkerVFD400
PowerWalkerVFD600
PowerWalkerVFD1000
QuickStartGuide
EN
EN
IMPORTANTSAFETYINSTRUCTIONS
SAVETHESEINSTRUCTIONSThismanualcontainsimportantinstructionsformodels
PowerWalkerVFD400/600/1000thatshouldbefollowedduringinstallationandmaintenance
oftheUPSandbatteries.
ThisproductisspeciallydesignedforPCsanditisnotrecommendedforuseinanylife
supportingsystemandotherspecificimportantequipment.
Thisequipmentcanbeoperatedbyanyindividualwithnoprevioustraining.
DonotplughouseholdappliancessuchashairdryerstoUPSreceptacles.
Thisunitintendedforinstallationinacontrolledenvironment(temperaturecontrolled,
indoorareafreeofconductivecontaminants).AvoidinstallingtheUPSinlocationswhere
thereisstandingorrunningwater,orexcessivehumidity.
Risk of electric shock, do not remove cover. No user serviceable parts inside. Refer
servicing
toqualifiedservicepersonnel.
Theutilitypoweroutletshallbeneartheequipmentandeasilyaccessible.ToisolateUPS
fromACinput,removetheplugfromtheutilitypoweroutlet.
IfUPSistobestoredforalongtime, it isrecommendedto recharge the batteries(by
connecting
theutilitypowertoUPS,switch“ON”),onceamonthfor24hourstoavoida
fullbatterydischarge.
PleasedonotusetheUPSinexcessoftheratedloadcapacity.
The UPS contains one/two largecapacity batteries. So the shell shall not be opened,
otherwise such
dangers as electric shock will be caused. If any internal overhaul or
replacementofthebatteryisrequired,pleasecontactthedistributor.
TheinternalshortcircuitingoftheUPSwillleadtodangerssuchaselectricshockorfire,
therefore,nowatercontainers(suchasawaterglass)shallbe
placedonthetopofthe
UPSsoastoavoidsuchdangersaselectricshock.
Donotdisposeofbatteryorbatteriesinafire.Thebatterymayexplode.
Donotopenormutilatethebatteryorbatteries.Releasedelectrolyteisharmfultothe
skinandeyes.
Itmaybetoxic.
IconΦontheratinglabelstandsforphasesymbol.
A battery can present a risk of electrical shock and high short circuit current. The
followingprecautionsshouldbeobservedwhenworkingonbatteries:
Removewatches,rings,orothermetalobjectsfromthehand.
Usetoolswithinsulatedhandles.
EN
Servicingofbatteriesshouldbeperformedorsupervisedbypersonnelknowledgeableof
batteries and the required precautions.Keep unauthorized personnel away from
batteries.
Whenreplacingbatteries,replacewiththesametypeandnumberofthesealedleadacid
batteries.
Themaximumambienttemperatureratingis40°C.
This pluggable type A equipment with battery already installed by the supplier is
operatorinstallableandmaybeoperatedbylaymen.
Duringtheinstallationofthisequipmentitshouldbeassuredthatthesumoftheleakage
currentsoftheUPSandtheconnectedloadsdoesnotexceed3.5mA.
Attention, hazardous through electric shock. Also with disconnection of this unit from
the mains, hazardous voltage stillmay beaccessible through supply from battery.The
battery supply should be therefore disconnected in the plus and minus pole of the
batterywhenmaintenanceorserviceworkinsidetheUPSis
necessary.
ThemainssocketoutletthatsuppliestheUPSshallbeinstalledneartheUPSandshallbe
easilyaccessible.
In case smoke is found coming out from the device, please cut off the power supply
quicklyandcontactthedistributor.
Donotkeeporusethisproduct
inanyofthefollowingenvironments:
o Anyareawithcombustiblegas,corrosivesubstanceorheavydust.
o Anyarea with extraordinarily high or low temperature (above 40˚C orbelow
0˚C)andhumidityofmorethan90%.
o Anyareaexposedtodirectsunshineornearanyheating
apparatus.
o Anyareawithseriousvibrations.
o Outdoor.
Intheeventthatthereisfireoccurringinthevicinity,pleaseusedrypowerextinguishers.
Theuseofliquidextinguishersmaygiverisetothedangerofelectricshock.
EN
1. SystemDescription
FrontPanel
1. PowerSwitch
2. UPSstatusIndicator
ACMode:Greenlighting
BatteryMode:Greenflashing
3. FaultLED:Redlighting
VFD400/VFD600Backpanel
VFD1000Packpanel
BackPanel
1. CircuitBreaker
2. ACinput
3. Outputreceptacles
4. Modem/PhoneLineSurge
Protection
EN
2. Installationandoperation
Inspection
RemovetheUPSfromitspackagingandinspectitfordamagethatmayhaveoccurredduring
shipping.Ifanydamageisdiscovered,repacktheunitandreturnittotheplaceofpurchase.
Charging
Thisunitisshippedfromthefactorywithitsinternalbatteryfullycharged,however,some
chargemaybelostduringshippingandthebatteryshouldberechargedpriortouse.Plug
the unit into an appropriatepowersupply andallowthe UPS tochargefully by leaving it
plugged in for
at least 10 hours with no load (no electrical devices such as computers,
monitors,etc.)connected.
Placement
InstalltheUPSunitinanyprotectedenvironmentthatprovidesadequateairflowaroundthe
unit,andisfreefromexcessivedust,corrosivefumesandconductivecontaminants.Donot
operateyourUPSinanenvironmentwheretheambienttemperatureorhumidityishigh.
ComputerConnection
PlugtheUPSintoa2pole,3wiregroundedreceptacle.Thenconnectonecomputerrelated
deviceintoeachofthepowerreceptaclessuppliedonthebackoftheUPS.
Modem/NetworkConnection
Plug incoming internet line into the “In” socket at the back of the UPS. Use one more
InternetlinecableandplugoneendoftheInternetlinecabletothe“Outsocketatthe
backoftheUPS.Plugtheotherendtothemodeminputsocketasshown.
 
Incoming
InternetLine
EN
TurnOn/Off
PresstheswitchoftheUPScontinuouslyfor1secondandtheUPSturnsintoitsnormalstate
(thegreenlightisonandthebeeperisoff)afteritperformsaselfdiagnosis(thebeeperand
theredandgreenindicatorlightsareon)forseveralseconds.Atthis
time,usermayturnonthe
PCandotherloads.PresstheswitchoftheUPScontinuouslyfor1secondtoturnofftheUPS.
Note:
For the convenience of maintenance, please turn onthe UPS first beforeturning on
thePCandtheotherloads,andturnoffthe
UPSaftertheloadsareturnedoff.
At ordinary times, we recommend to remain the UPS on with the battery charging
(eveniftheloadsareturnedoff),whichisbenefittothemaintenanceofthebattery.
3. TroubleShooting
Symptom PossibleCause Remedy
1.Missingbattery 1.Chargebatteryupto8hours
2.Batterydefect
2. Replace with the same type
ofbattery
NoLEDdisplay
onthefrontpanel
3.Powerswitchisnotpressed 3.Presspowerswitchagain
1.OverloadoftheUPS 1.Removesomenoncriticalload
2.Batteryvoltageistoolow
2.Chargebattery8hoursor
more
Whenpower
failure,backup
timeisshort.
3.Batterydefectduetohigh
temperatureoperation
environment,orimproper
operationtobattery.
3.Replacewiththesametype
ofbattery
1.Circuitbreakerisbroken. 1.Resetthecircuitbreaker.
Mains normal but
LEDisflashing.
2.Powercordisloose.
2.Reconnectthepowercord
properly.
Ifanyabnormalsituationsoccurthatarenotlistedabove,pleasecallservicepeopleimmediately.
EN
4. Specifications
MODEL
PowerWalker
VFD400
PowerWalker
VFD600
PowerWalker
VFD1000
CAPACITY VA/W 400VA/200W 600VA/300W 1000VA/600W
INPUT Voltage 110/120VACor220/230/240VAC
VoltageRange 90145VAC/170280VAC
OUTPUT Voltage 110/120VACor220/230/240VAC
VoltageRegulation(Batt.
Mode)
±10%
Frequency 50Hzor60Hz
FrequencyRegulation(Batt.
Mode)
+/1Hz
OutputWaveform ModifiedSinewave
BATTERY BatteryType&Number 12V/4.5Ahx1pc 12V/7Ahx1pc 12V/7.2AH*2
BackupTime(ataPCload
with15"monitor)
5minutes 8minutes 30minutes
RechargeTime 10hoursto90%aftercompletedischarge
TRANSFERTIME Typical 26ms
ACMode GreenLEDlighting
BatteryMode GreenLEDflashingevery4seconds
LowBatteryatBatteryMode GreenLEDflashingeverysecond
Fault RedLEDlighting
BatteryWeakatACMode RedLEDflashingevery2secondsfor30seconds
INDICATOR
BatteryFaultatACMode RedLEDflashingthreetimesevery2seconds
BatteryMode Soundingevery4seconds
LowBatteryatBatteryMode Soundingeverysecond
Fault Continuouslysounding
BatteryWeakatACMode Soundingevery2secondsfor30seconds
AUDIBLEALARM
BatteryFaultatACMode Soundingthreetimesevery2seconds
PROTECTION FullProtection Discharge,overcharge,andoverloadprotection
Dimension,DXWXH(mm) 231x81x185 312x94x250PHYSICAL
NetWeight(kgs) 3.1 3.8 6.7
OperatingEnvironment 0‐40°C,090%relativehumidity(noncondensing)ENVIRONMENT
NoiseLevel Lessthan40dB
EN
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

PowerWalker VFD 1000 (CEE 7/3) Owner's manual

Category
Uninterruptible power supplies (UPSs)
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI