  • Hello! I am an AI chatbot trained to assist you with the Dacor Epicure EF36LNDFSS Planning Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
11.5
36” Wide
Stand Alone Refrigerator
EF36RNDFSS, EF36LNDFSS, EF36BNDFSS,
IF36BNDFSF, & IF36INDFSF
1/2
Pr o d u c t di m e n s i o n s
◊ ForEF36Seriesmodelsthedepthfromthefrontofthedoor
(w/odoorhandles)tothebackoftherefrigeratorchassis
is27”(686mm),271/4”(692mm)forIF36Serieswithout
paneling.
◊ Thedepthofthecabinetlessthedooris241/4”(616mm).
◊ Thepowercordis60”(1524mm)long.
◊ Theheightfromthetopoftherefrigeratortothefloorwith
thelevelinglegsinthedownpositionis697/8”(1775mm)
◊ Theheightfromthetopoftherefrigeratortothefloorwith
thelevelinglegsinthefullyextendedpositionis705/8”
(1794mm).
◊ Therefrigeratorwidthfromedgetoedgeis355/8”(905
mm).
do o r sw i n g di m e n s i o n s
Theareatotheleftandtherightoftheappliancemustpermitboth
doorstoopentoaminimumof90°.Allowaminimumof
21/2”(64mm)spacebetweenthesideoftherefrigeratordoors
andacornerwall.
70 ½” Min.
(1791 mm)
30”.
(762 mm)
Water Valve Location - Approximate Dimensions
24” (610 mm)
36” Min. (914 mm)
16”
(406 mm)
CabinetLayout
◊ Agroundedthreeprongnon-GFCIelectricaloutletmust
beprovidedandshouldbeinalocationthatallowsthe
refrigeratortobeconnectedwithoutanextensioncord.See
“ElectricalRequirements”foradditionalinformation.
◊ Theplumbingforthewaterlinecancomethroughthefloor
flushtoorfromthebackwall.Installthewatervalveina
locationthatallowsittobeturnedoffwithoutmovingthe
refrigeratoroutintheeventtherefrigeratororwaterline
requiresservice.
wa t e r su P P l y re q u i r e m e n t s
◊ Allinstallationsmustmeetlocalplumbingcoderequirements.
◊ Use1/4”(6mm)copperlinetoconnecttherefrigeratortothe
housecoldfreshwatersupply.
◊ Installashutoffvalvebetweentherefrigeratorandwater
supply.Theshutoffvalveshouldbeadrilledsaddlevalve.
Seethediagramaboveforrecommendedlocation.
◊ Donotuseapiecingtypeor3/16”(4.76mm)saddlevalve
whichwillreducewaterflowandclogmoreeasily.
◊ Allowaminimumof24”(610mm)diameterserviceloopof
coppertubingoutsidethewallorfloorforeasyconnectionto
thewatersupply.
Cold water supply
Connecttheicemakertoacoldwaterlinewithwaterpressure
between35and120psi.Ifyouhaveanyquestionsaboutyour
waterpressure,callyourutilitycompany.
Reverseosmosiswatersupply
IMPORTANT:Thepressureofthewatersupplycomingoutof
areverseosmosissystemgoingtothewaterinletvalveofthe
refrigeratorneedstobebetween35and120psi(241and827
kPa).
Ifareverseosmosiswaterfiltrationsystemisconnectedtoyour
coldwatersupply,thewaterpressuretothereverseosmosis
systemneedstobeaminimumof40to60psi(276to414kPa).
Ifthewaterpressuretothereverseosmosissystemislessthan40
to60psi(276to414kPa):
■ Checktoseewhetherthesedimentfilterinthereverse
osmosissystemisblocked.Replacethefilterifnecessary.
■ Allowthestoragetankonthereverseosmosissystemtorefill
afterheavyusage.
■ Ifyourrefrigeratorhasawaterfilter,itmayfurtherreduce
thewaterpressurewhenusedinconjunctionwithareverse
osmosissystem.Removethewaterfilter.
Ifyouhavequestionsaboutyourwaterpressure,callalicensed,
qualifiedplumber.
Revised
06/12/08
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
11.6
36” Wide
Stand Alone Refrigerator
EF36RNDFSS, EF36LNDFSS, EF36BNDFSS,
IF36BNDFSF, & IF36INDFSF
2/2
el e c t r i c a l re q u i r e m e n t s
A115Volt,60Hz.AConly15or20ampfused,groundedelectrical
supplyisrequired.Itisrecommendedthataseparatecircuit
servingonlyyourrefrigeratorbeprovided.Useanoutletthat
cannotbeturnedoffbyaswitch.Donotuseanextensioncord.
12” (305 mm)
12”
(305 mm)
ELECTRICAL LOCATIONS -
APPROXIMATE DIMENSIONS
Revised