VIESMANN
Installation instructions
for contractors
Radial fan replacement
for the Vitodens 100-W, type WB1B
5355 081 GB 2/2008 Dispose after installation.
Safety instructions
Please follow these safety instructions closely to prevent accidents
and material losses.
Safety instructions explained
Danger
This symbol warns against the
risk of injury.
Note
Details identified by the word "Note"
contain additio nal information.
Installation, initial start-up, inspection,
maintenance and repairs must only be
carried out by a competent person
(heating engine er/installati on contrac-
tor).
Before working on the equipment/
heating system, is olate the power
supply (e.g. by re moving a separ ate
mains fuse or by means of a mains
isolator) and safeguard against
unauthoris ed reconnection .
When using gas as fuel, also close
the main gas shut-off valve and safe-
guard against unauthorised reopen-
ing.
Repairing components which fulfil a
safety function can compromise the
safe operation of yo ur heating sys-
tem.
For replacements, use only original
spare parts supplied or approved by
Viessmann.
Opening the Vitodens and removing the burner
Installation and service instruc-
tions
1. Und o two screws and remove fan
A with gas valve B and venturi
nozzle C.
2. Und o two screws and remove gas
valve B together with venturi noz-
zle from fan A.
3. Fit new fan A with new gasket C
to gas valve B.
Fixing screw torque: 3 Nm.
4. Fit new fan A with gas valve B
and new gaske t D to burner.
Fixing screw torque: 4 Nm.
5. In stall the burner.
Note
Insert new gaskets on all gas con-
nections.
Replacing the radial fan
2
5355 081 GB
6. S tart up the b oiler and c heck for
tightness.
Installation and service
instructions
Danger
Escaping gas leads to a risk
of explosion.
Check gas equipment for
tightness.
Replacing the radial fan (cont.)
3
5355 081 GB
4
Printed on environmentally friendly,
chlorine-free bleached paper
5355 081 GB Subject to technical modifications.
Viessmann Werke GmbH&Co KG
D-35107 Alle ndorf
Telephone: +49 6452 70 -0
Fax: +49 6452 70- 2780
www.viessm ann.com
Viessmann Lim ited
Hortonwood 30, Telford
Shropshire, TF1 7YP, GB
Telephone: +44 1952 675000
Fax: +44 195 2 675040
E-mail: info [email protected] m
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Viessmann Vitodens 100-W WB1B Installation Instructions For Contractors

Type
Installation Instructions For Contractors

Viessmann Vitodens 100-W WB1B is a reliable heating system featuring a radial fan with gas valve and venturi nozzle for efficient and safe operation. Its user-friendly design allows for easy installation and maintenance, reducing the need for frequent repairs.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI