SPIRIT™ MODEL 308/616
COMMUNICATIONS SYSTEM
Product Information Guide
AT&T Technical Training Services
Dublin, Ohio
First Edition
February 1987
Developed by
AT&T Technical Training Services
5151 Blazer Memorial Parkway
Dublin, Ohio 43017-1392
© 1987 AT&T Technical Training Services. All rights reserved. This material may not be
reproduced, stored in a retrieval system, or transmitted in whole or in part, in any form or by
any means, electronic, mechanical, photocopying, recording, or otherwise, without prior
written permission of the publisher.
Printed in the United Sates of America.
T217 Product Information Guide
TABLE OF CONTENTS
Page
OVERVIEW
SYSTEM CONFIGURATION
SPIRIT COMPETITION
SYSTEM DOCUMENTATION
GROUNDING REQUIREMENTS
INSTALLATION
SPIRIT WIRING PLAN
PIN ASSIGNMENTS
MODULAR WIRING
EXTERNAL PAGING EQUIPMENT
AUXILIARY LINES
EXTERNAL ALERT
MULTIFUNCTION STATION SETS
INITIAL SYSTEM TEST
FEATURE TONES AND RINGING
SPEEDCALLING
SPIRIT FEATURE ADMINISTRATION
SYSTEM MAINTENANCE
WARRANTY AND MAINTENANCE OPTIONS
1
3
5
5
6
7
8
8
11
15
15
17
19
20
20
21
23
25
26
AT&T – PROPRIETARY
T217
Product Information Guide
LIST OF FIGURES
FIGURE 1 - SPIRIT SYSTEM CONFIGURATION
FIGURE 2 - SPIRIT COMPETITION MATRIX
FIGURE 3 -
TYPICAL SPIRIT WIRING PLAN
FIGURE 4 - MODULAR WIRING
FIGURE 5 - SBDS WIRING MATERIALS
FIGURE 6 - PAGING SYSTEM WIRING
FIGURE 7 - EXTERNAL ALERT INTERFACE
FIGURE 8 - 24-BUTTON MULTIFUNCTION STATION SET
FIGURE 9 - SYSTEM ADMINISTRATION OVERLAY MODEL
308/616
FIGURE 10 - HARDWARE REPLACEMENT INFORMATION
2
4
9
10
13
14
16
18
22
24
AT&T – PROPRIETARY
T217
1
Product Information Guide
SPIRIT™ MODEL 308/616
COMMUNICATlONS SYSTEM
OVERVIEW
The SPIRIT Model 308/616 CS is a low-cost, high-quality, high-reliability product with fixed
features and modular equipment. AT&T is the only company offering a system with a full
range of features and services in one package:
Call Pick-Up
Idle-Line Preference
Hands-Free Answering Intercom
Power Failure Operation
and many other features, providing a product without equal in the telecommunications
marketplace.
You will become thoroughly familiar with these features, so you can teach your customers to
use them when you install the system. You, the Systems Technician, are another aspect of
our edge on the competition. By taking the time to study this INFORMATION GUIDE fully, and
attending the hands-on session you are scheduled for in a few weeks, you will be able to
install and maintain the SPIRIT system and teach your customers how to use it to the best
advantage in their businesses. Your professional skills and familiarity with AT&T products
return true value for our customers’ service dollars.
AT&T — PROPRIETARY
Product Information Guide
2
T217
2500 SET
POWER FAILURE
616 EXPANSION UNIT
308 CONTROLLER
24-BUTTON SET
MUSIC
PUBLIC
EXTERNAL
ALERTER
ADDRESS
NETWORK
INTERFACE 6-BUTTON SET
217-3 2/87 1
FIGURE 1 -
SPIRIT
SYSTEM CONFIGURATION
AT&T – PROPRIETARY
T217
3
Product Information Guide
SYSTEM CONFIGURATION
The
308
SPIRIT
CS
is the smallest configuration; it has up to three CO lines and eight station
lines. Adding the optional expansion unit allows growth up to six CO lines and sixteen
stations, yielding the 308/616 Spirit system.
The model 308 control unit consists of a textured, gray plastic housing and base, enclosing
the PWB (printed wiring board) and power supply. The open grillwork on the control unit
allows proper system ventilation. The control unit is approximately 16 inches wide, 8 inches
high, and 5 inches deep. A fully equipped unit (308/616) weighs less than 10 pounds.
The system functions over 2-pair wiring and uses loop-start lines for the CO (central office)
facilities. The SPIRIT CS can be configured behind another PBX or cross-connected directly
to the CO. Stations cabled with tinsel cord, which does not have the twisted-pair structure
required to transmit data, have to be within 25 feet of the controller to function properly. If
stations are wired with twisted-pair solid-conductor cable, the working limits are 1000 feet
from the controller.
The ALERT, PAGE, LINE AUX, TELCO LINES, and STATIONS connectors are positioned and
labeled as shown in Figure 1. An RCA phono jack interfaces MOH (Music-On-Hold). The
MOH volume control can be easily adjusted by hand.
AT&T – PROPRIETARY
Product Information Guide
4
T217
AT&T
TIE
ITT
TOSHIBA
FEATURE
SPIRIT
ULTRACOM ARIES STRATA
308/616
CKI 401
VI
CO LINES
STATIONS
INTERCOM PATHS
SPEAKERPHONE
CONFERENCE w/DROP
SYSTEM SPEEDCALL
PERSONAL SPEEDCALL
DO NOT DISTURB
TRANSFER
HFAI/DISABLE
STATION MSG ACTIVATION
MUSIC-ON-HOLD INTERFACE
PAGING INTERFACE
PROGRAMMABLE FEATURES
IDLE LINE PREFERENCE
RINGING LINE PREFERENCE
DISTINCTIVE RINGING
TOLL RESTRICTION
0/1 restrict
allowed list
CALL PICKUP
NIGHT SERVICE
CENTRALIZED ADMIN
BRIDGING INDICATION
PWR FAILURE OPERATION
PWR FAILURE PHONES
CUSTOMER INSTALLABLE
6
16
2
yes
yes
70#
16#
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
8
18
0
yes
no
100#
14#
yes
yes
no
no
opt
opt
no
no
no
yes
yes
no
no
no
yes
no
no
opt
opt
opt
6
16
3
no
yes
yes
no
no
no
no
yes
yes
yes
yes
no
no
no
no
yes
no
no
no
no
no
no
no
no
6
16
2
yes
no
opt
opt
no
yes
yes
opt
opt
yes
yes
no
yes
yes
no
no
no
no
yes
yes
no
no
no
no
FIGURE 2 -
SPIRIT
COMPETITION MATRIX
AT&T – PROPRIETARY
T217
5
Product Information Guide
SPIRIT
COMPETITION
The SPIRIT CS faces major competition for small business customers needing an electronic
key telephone system. Three companies; TIE, ITT, and TOSHIBA, are top competitors with
opposite page.
SYSTEM DOCUMENTATION
systems in that communications market. A feature-comparison matrix is shown on the
A complete set of documentation is included with this package. You will use it as part of
your study material, and it is yours to keep for future reference. SPIRIT CS control unit
documentation includes:
Administration Manual
- Provides detailed information on customizing the system.
Customer Installation Instructions
- Details the materials needed and instructions on
cabling and wiring.
Station set documentation includes:
User Manual - Details information about system features and operation of the
station sets.
Quick Reference Chart - A two page job aid outlining station set method-of-
operation.
Designation Strips - Used to designate the station and line appearance buttons on
each station set.
AT&T – PROPRIETARY
Product Information Guide
6
T217
GROUNDING REQUIREMENTS
Proper grounding is fundamental as protection against lightning/power surges, power
crosses on CO lines, and static discharge to equipment. The green-wire ground of the AC
outlet is the only ground serving the SPIRIT system. It must be connected to the building
1.
2.
3.
4.
ground. Use the following procedures to verify grounding:
Check the AC outlet wiring with an Ideal 61-035 tester or equivalent. The tester
comes with instructions.
Visually inspect the telco protection bonding to the AC power ground. Ensure that
local practices have been followed. To minimize costs, no more than 10 minutes
are allowed for this inspection. If more than 10 minutes is required, do not
complete the inspection.
If you find inadequate grounding/protection, and the the customer owns the
equipment or has a sales-type lease, warn him/her that lightning and power-surge
damage are excluded from warranty and contract coverage. Also tell the customer
that the risk from operating equipment without adequate protection is quite high.
The customer can buy a TII1428 AC power line surge protector (PEC 8310-001).
While surge protection purchase is not required when buying the system, remind
the customer that lightning and power surge damage are excluded from warranty
and contract coverage. Purchase of the surge protector is a way to reduce, but
not eliminate, the customer’s risk, If s/he is under a term plan, the surge protector
can be installed at AT&T expense, if local practice calls for it.
AT&T – PROPRIETARY
T217
7
Product Information Guide
INSTALLATION
The following procedures are required to install a SPIRIT CS, and the customer pays for
them in the installation charge:
1.
2.
3.
4.
5.
6.
7.
Install the control unit
- Special consideration should be given to:
Local telco CO line terminations (within 25 feet)
Nearest AC outlet for the control unit (within 6 feet)
Access for administration, future growth, and changes
Allowing for proper ventilation (21 inches clearance)
Install station wiring, connect and label sets
- Wiring plan same as MERLIN
®
CS.
Administer system-level features
- Use the system planner and ensure that a copy
is retained with the control unit for programming. The system must be
reprogrammed if the control unit is replaced.
Connect the system to the network interface
- Wire to the RJ connecting blocks at
the demarcation point.
Install auxiliary equipment
- Includes remote bell, music source, or paging system.
Test the system
- Verify controller and set operation.
Customer education - The systems technician’s responsibility; you will become
familiar with the customer training outline in the User Training Manual. lt will guide
your presentation.
At this point, take time to read the Customer Installation Instructions Manual in its entirety.
AT&T – PROPRIETARY
Product Information Guide
8
T217
SPIRIT
WIRING PLAN
The SBDS (Small-Business Distribution System) wiring plan for the SPIRIT is the same plan
used for the MERLIN CS. The SPIRIT system requires two-pair wiring, but four-pair wiring is
used to facilitate migration to four-pair systems in the future. Unlike MERLIN CS control
units, SPIRIT control units ship WITHOUT 267C adapters. If these are needed, you must
provide them from your supply. Their cost is covered in the flat-rate wiring billed to the
customer. Station sets ship WITH mounting cords.
PIN ASSIGNMENTS
The modular pin assignments for the station jack on the control unit and station set are
shown below:
PIN
NUMBER
1
2
3
4
5
6
7
8
CONTROLLER JACK
8-position
No-connection
No-connection
Data/Ring
Voice Ring
Voice Tip
Data/Tip
No-connection
No-connection
PIN
NUMBER
1
2
3
4
5
6
STATION JACK
6-position
No-connection
Data/Tip
Voice Tip
Voice Ring
Data/Ring
No-connection
AT&T – PROPRIETARY
T217
9
Product Information Guide
103A, 104A, 105A,
630B CONNECTING
Z601A
ADAPTER COLOR CODES FOR 4–PR.
DIW CABLE OR DW8A-SE
BLOCK
CORD
103A, 104A, 105A,
630B CONNECTIN6
BLOCK
Z601A
ADAPTER COLOR CODES FOR 3–PR.
DISTRIBUTION CABLE
( H-STATION WIRE )
625, 725, 630B,
830B CONNECTING
BLOCK
217–8 3/87 .89
Z601A
ADAPTER COLOR CODES FOR 4–PR.
DIW CABLE OR DW8A–SE
CORD
FIGURE 3 - TYPICAL
SPIRIT
WIRING PLAN
AT&T – PROPRIETARY
Product Information Guide
10
T217
CONTROLLER POWER CORD
GREEN–WIRE
GROUND
NETWORK INTERFACE D4CH
JACK
RJ11, RJ14, OR RJ21
A JACK F1ELLD INSTALLED
NEAR YOUR CONTROL
UNIT LOCATION
CABLE EXTENDING FROM
THE JACK FIELD TO EACH
TELEPHONE LOCATION
D4BU CORD
AC OUTLET
ADD SURGE PROTECTOR
WHERE APPROPRIATE
JUMPER CORDS
PLUGGED INTO THE
JACK FIELD AND INTO
THE CONTROL UNIT
Z122C
APPARATUS BOXES
W/Z600 SERIES ADAPTERS
DW8A CORD
4–PR DIW OR
REUSED 25–PR CABLE
103A CONNECTOR
A MODULAR JACK AT THE END OF
EACH CABLE (TELEPHONES WILL BE
PLUGGED IN LATER)
BLOCK
D4BU CORD
217–7 3/87 1
FIGURE 4 - MODULAR WIRING
AT&T – PROPRIETARY
T217
11
Product Information Guide
MODULAR WIRING
The method of connection depends on the building wiring termination. Use the following
station and distribution wire:
Tinsel Cord - A 2-pair double-ended modular cord used primarily for sets.
D-Station Wire - A 22-gauge, two-pair distribution wire.
H-Station Wire - A 24-gauge, three-pair distribution wire.
D-Inside Wire - DIW is a 24-gauge, multiple-paired cable.
When reusing existing building wiring, adapters can be used but will require a Z122C
apparatus box.
AT&T – PROPRIETARY
Product Information Guide
12
T217
NOTES
T217
13
Product Information Guide
ITEM
103A-50
258A
D2R-29
D2R-29
D2R-29
D4BU-29
D4BU-29
D4BU-29
D4CE-50
DW8A-SE
DW8A-SE
D8W-87
DIW
D-Station
H-Station
Z122C
Z600A
Z601A
Z602A
Z610A
DESCRIPTION
COMCODE
Connecting Block
25-pair to Mod. Adapter
Mounting Cord 7 foot
Mounting Cord 14 foot
Mounting Cord 25 foot
Mounting Cord 7 foot
Mounting Cord 14 foot
Mounting Cord 25 foot
Set Extension Cord 50 foot
Distribution Cord 100 foot
Distribution Cord 200 feet
Mounting Cord 2.5 feet
Inside Wire Spool 1000 feet
2-Pair wire Ivory 600 feet
3-Pair wire Gray 600 feet
103104220
102605136
103732541
103732566
103732582
102479904
102479896
102479888
103951570
103895694
103736138
104160148
403101140
401836580
401836598
Apparatus Box
103980843
Mod to Mod Adapter
103946646
Mod to Cut-down Adapter
103946653
Mod to 25-pair Adapter
103946661
Cut-down to Mod Adapter
103950556
FIGURE 5 - SBDS WIRING MATERIALS
AT&T – PROPRIETARY
Product Information Guide
14
T217
CONTROLLER
PAGE
SIX–POSITION
WIRING LABEL MODULAR CORD
PAGE INPUT
MUSIC IN
MALE–MALE
POWERMATE
RCA–ENDED
CORD
TUNER
Y CONNECTOR
25' RCA–ENDED
CORD
Y CONNECTOR
25' RCA-ENDED
CORD
SPEAKER
217-9 3/87 1
FIGURE 6 - PAGING SYSTEM WIRING
AT&T – PROPRIETARY
T217
15
Product Information Guide
EXTERNAL PAGING EQUIPMENT
The PagePac 1 (for systems with optional public address system) is a loudspeaker paging
system with 1-way transmission.
Answerback paging is not supported by the
SPIRIT
CS.
Typical hardware provided with the system is a PowerMate amplifier, speakers and wiring.
The amplifier connects to the control unit via a 4-conductor, 6-position modular cord. We
recommend a direct connection from the control unit whenever possible. The speakers
connect through 2-conductor, RCA-jack ended cords. The PowerMate is supplied with six
24-foot cords, “Y” adapters and three speakers.
AUXILIARY LINES
There are two LINE AUX jacks on the 308 controller, and one on the 616 expansion unit. The
jacks bridge the CO lines at the control unit, and are the connection to an outside line
during a power failure. A standard (tip/ring) 2500 set or equivalent must be used for
power-failure telephones. In the event of a commercial power failure, programmed system
information will be retained in memory indefinitely.
The jacks are also useful as dedicated lines for answering machines, facsimile machines,
and modems. If an answering machine is cabled to LINE AUX jack 1 on the 308 and is in-
use (off-hook), the incoming line 1 button appearance cannot be accessed at the station set.
LINE AUX jack 2 on the 308 control unit bridges line 2, and the LINE AUX jack on the 616
expansion unit bridges incoming line 4.
AT&T – PROPRIETARY
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31

AT&T SPIRIT 616 EXPANSION UNIT Product information

Category
Telephones
Type
Product information
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI