V-ZUG 016 Installation guide

Type
Installation guide
The appliance should be installed by qualified personnel only.
Each step must be carried out and checked in full in the order specified.
Validity
These installation instructions apply to:
016 (DI-SMC12, construction width 120 cm)
General notes
If other firing systems are being used at the same time (e.g. wood, gas, oil or coal-fired heating appliances), safe operation is
only possible providing a room negative pressure of 4 Pa (0.04 mbar) is not exceeded at the location of the appliance. Risk
of toxic fumes! An adequate flow of fresh air must be guaranteed e.g. via non-closable openings in doors or windows and in
combination with an air-intake/exhaust-air wall box or by other technical means.
If the appliance is installed over hobs, each cooking zone must be fitted with an ignition fuse and the minimum distances
(see 'Dimensions') must be adhered to.
Efficient repairs can only be guaranteed if it is possible to uninstall the complete appliance at any time without causing any
damage.
Comfort ventilation appliance
This appliance may only be operated with a suitable comfort ventilation unit made by the company Zehnder Comfosystems.
Other comfort ventilation appliances or external blowers are not equipped with the required safety features.
Suitable comfort ventilation appliances from Zehnder Comfosystems: Comfoair 350, Comfoair 500 (technical modifications reserved).
Always follow the manufacturer’s installation instructions and safety precautions.
Identification plate
Remove the grease filters. The identification plate is located on the inside of the appliance.
Supplied installation accessories
All fixing elements are contained in the scope of delivery.
Electrical connections
Electrical connections must be carried out by trained electricians in accordance with the guidelines and standards for low-
voltage installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug
and socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles
switching are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors
ensure safe and fault-free operation. After installation, live parts and cables with basic insulation must not be accessible.
Check old installations.
The appliance is designed for use up to a max. altitude of 2000 m above sea level.
See the identification plate for information on the necessary mains voltage, type of current and fuse protection.
When using the insert box of the Zehnder Comfosystems company, follow the accompanying installation instructions.
Installation instructions
J016.113-2
Range hood DI-SMC12
12.12.12
Island hood
Operating mode: extracted air with comfort ventilation system
1
Electric interface for comfort ventilation appliances from Zehnder Comfosystems
Cable colour
12V GND
CH
Tch
1 2 3 4
1
blue
2
yellow
3
red
4
black/white
The electric interface at the side of the comfort ventilation appliance must be declared safety extra-low voltage (SELV) in
accordance with IEC 60335-1 3.4.2.
Dimensions
The positioning of the Zehnder insert box Z in the ceiling must be planned and coordinated in relation to the hob.
Max. positional deviation: ±1 cm (in all directions)
280
280
750
485
1200
100
ø 160
B
A *
Z
* Grid spacing: 10 mm
Telescopic casing
(available in various heights)
Height A: see planning documents for kitchen appliances
Distance above hob
Minimum height B:
For electric hob:
For gas hob:
min. 600 mm
min. 750 mm
Installation
Note
Planning features for non-destructive de-installation and maintenance of the appliance.
Do not route telescopic casing in suspended ceilings.
Avoid silicon joints between the telescopic casing and the appliance.
All plastering, plasterboarding, wall papering or painting work is to be carried out prior to installing the appliance.
This appliance is to be fastened directly under the Zehnder insert box, which must be precisely attached to the ceiling beforehand.
The supply air connection from the Zehnder insert box must be freely accessible. Always follow the manufacturer’s installation
instructions and safety precautions.
Installation instructions
J016.113-2
Range hood DI-SMC12
12.12.12
Island hood
Operating mode: extracted air with comfort ventilation system
2
Installation
1. Affix paper template C to the ceiling – aligning it with the supply air
connection from the Zehnder insert box. Make drill holes for suitable
screw mounting as per the manufacturer’s instructions (see package
leaflet).
2. Fasten the exhaust air hose D (min. ø 160 mm) to the supply air connec-
tion.
3. Adjust carrier supports T1, T2 to adequate length (grid spacing: 10 mm)
and fasten securely with 8 screws S1 (ø 4 × 8 mm).
4. Fix carrier supports to the ceiling with screws S2. Follow the manufactur-
er's instructions for screw mounting (see package leaflet).
5. Fit upper lagging sheets V1, V2 with cage nuts M. Screw both halves
together with the spring F and screw S3 (M4 × 7 mm). Slide from bottom
onto carrier supports.
6. Screw in 4 screws S4 (ø 4 × 8 mm) at the bottom to carrier support T2.
Hang the hood H in the key holes.
7. Remove the grease filters.
8. Tighten screws S4 and additionally secure the hood with 4 screws S5
(ø 4 × 8 mm) from below and with 2 screws S6 (ø 4 × 8 mm) from above.
9. Establish plug connection G.
10. Remove cover E.
Establish electrical connection (see 'Electrical connections').
Refer for this to the installation instructions for the comfort ventilation
system.
Put cover E back.
11. Fasten exhaust air hose D to the exhaust air connection. Ensure hose is
free from kinks and is stretched.
12. Fix upper lagging sheets V1, V2 with 2 screws S7 (ø 3 × 9 mm).
13. Fit lower lagging sheet V4 with cage nuts M and from rear put onto carrier
support T2. Attach lower lagging sheet V3 from the front and screw both
halves together with spring F and screw S3 (M4 × 7 mm).
14. Install lower cover strips U2. Cut upper cover strips U1 to adequate length
and fit them.
15. Reinstall the grease filters.
U1
U2
S6
T2
D
H
E
G
V2
V3
V4
C
S2
V1
T1
6./8. 15.
U2
U1
T1
T2
S1
3.
T2
H
S4
S5
5./14. 13.
V1, V3
V2, V4
M
F
S3
S7
V2
T1
V1
F
U1
S3
Installation instructions
J016.113-2
Range hood DI-SMC12
12.12.12
Island hood
Operating mode: extracted air with comfort ventilation system
3
  • Page 1 1
  • Page 2 2
  • Page 3 3