Zeus Appollo Z20I4KTL User manual

Type
User manual

This manual is also suitable for

Phone: (07)31236148
350-00077-01
Beijing Hua Xin Liu He Investment (Australia) Pty Ltd.
Brisbane Office
32 Cr
Banyo, QLD 4014
ockford Street
Phone: (07) 31236148
Fax: (07) 32664758
Perth Office
1/87 President Street
Welshpool, WA 6106
Phone: (08) 65556518
Fax: (08) 94704103
USER MANUAL
Z20I4KT/Z20I5KT/Z20I6KT/
Z20I4KTL/Z20I5KTL/Z20I6KTL
Contents
1. Symbols ............................................................................................ 1
2. Safety ............................................................................................... 2
3. Installation ....................................................................................... 4
3.1 Mounting Instruction .............................................................. 4
3.2 Unpacking ......................................................................... 5
3.3 Equipment Installation ....................................................... 6
3.3.1 Selecting the installation position ................................. 6
3.3.2 Mounting Procedure ..................................................... 9
3.4 Electrical Connection ............................................................. 12
3.4.1 Connection to Grid (AC Side Connection) .................... 12
3.4.2 DC Side Connection ...................................................... 15
3.4.3 RS485 Communication.................................................. 20
3.4.4 USB Communication ..................................................... 25
3.5 Troubleshooting ....................................................................... 25
4. System Operation ....................................................................... 29
4.1 Functions of Indicating Lights ................................................ 29
4.2 LCD Display Descriptions ....................................................... 30
4.2.1 Top Area Flow of Power Generated ........................... 30
4.2.2 Middle Left Status Information .................................. 31
4.2.3 Right Middle AreaHistogram Display ........................ 38
4.2.4 Bottom Area ................................................................. 39
4.3 Key Operation and LCD Description ...................................... 39
4.3.1 Key Description ............................................................. 40
4.3.2 Key Operation and LCD Description .............................. 40
4.4 Menu Introduction ................................................................ 40
4.5 Start up Introduction ............................................................. 41
4.6 Settings Description ............................................................... 41
4.6.1 Error History Display ..................................................... 42
4.6.2 Time Setting.................................................................. 42
4.6.3 Language Setting .......................................................... 43
4.6.4 Set the Histogram Display in ‘Year Mode’ .................... 44
4.6.5 Set Communication Method......................................... 45
4.6.6 RESET Zigbee ID ............................................................ 46
4.6.7 Reset WiFi ..................................................................... 47
4.6.8 Reload WiFi .................................................................. 48
4.6.9 Set 70% Rated Load ...................................................... 48
4.7 Error Message ....................................................................... 50
5. Technical Parameters ..................................................................... 51
5.1 Technical Parameters .............................................................. 50
Note1: The model Z20I4KTL, Z20I5KTL and Z20I6KTL are only used
in Australia (PV voltage lower than 600V). .................................... 50
5.2 Temperature Derating Character ............................................. 55
6. Certificates ..................................................................................... 56
7. Maintenance .................................................................................. 57
7.1 Checking the DC Switch ........................................................... 57
8. Warranty ........................................................................................ 58
8.1 Warranty Period ...................................................................... 58
8.2 Warranty Card ......................................................................... 58
8.3 Warranty Conditions................................................................ 58
8.4 Scope of Warranty ................................................................... 58
9. Contact ........................................................................................... 60
1
1. Symbols
Caution! - Failure to observe a warning indicated in this
manual may result in minor or moderate injury.
Danger of high voltage and electric shock!
Danger of hot surface!
Product should not be disposed as normal household waste.
This side up - The package must always be transported, handled
and stored in such a way that the arrows always point upwards.
Components of the product can be recycled.
Fragile-The package/product should be handled carefully and
never be tipped over or thrown.
Stack Limitation - 6 units of identical packages that may be
stacked in maximum.
Keep Dry The package/product must be protected from
excessive humidity and must accordingly be stored under cover.
CE Mark
Refer to the operating instructions
2
2. Safety
Figure 2 -1
Z20I4KT/Z20I5KT/Z20I6KT/Z20I4KTL/Z20I5KTL/Z20I6KTL inverter of Beijing
Hua Xin Liu He Investment (Australia) Pty Ltd. (hereinafter referred to
as Zeus Appollo Solar) strictly conforms to related safety rules in design
and test. As electric and electronic equipment, Safety regulation shall be
followed during installation and maintenance. Improper operation may
bring severe damage to the operator, the third party and other properties.
The installation and maintenance of the inverters must be performed by
qualified personnel only in compliance with national and local standards
and regulations.
Before installation and maintenance, DC input and AC output of the
inverter should be cut off beforehand and the inverter cannot be touched
within 10 minutes after power cut-off in case of electric shock.
Partial temperature of the inverter may exceed 60 during operation,
please do not touch in case of scalding.
3
All electric installation should conform to local electric standard and
permission has to be obtained from local power supply department before
synchronization by qualified personnel.
Children must be kept away from inverters.
Please do not open the front cover of inverter. Apart from wiring terminal,
touching or changing components without authorization may cause
damage to people and inverters. Zeus Appollo Solar may deny the
obligation of warranty service accordingly.
Static electricity may damage electronic components and proper
measures shall be adopted to avoid static electricity.
The output voltage of proposed PV array should be lower than the
inverter maximum rated input voltage; Otherwise, Zeus Appollo Solar will
not undertake any obligations and warranty services.
Please switch off the breaker between PV-Inverter and Grid (utility) firstly
before any service. Or else electric hazards will be caused.
When the photovoltaic array is exposed to light, it supplies a DC voltage to
the PCE.
PV modules should have an IEC61730 class A rating. If the maximum AC
mains operating voltage is higher than the PV array maximum system
voltage, PV modules should have a maximum system voltage rating based
upon the AC mains voltage.
If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may be impaired.
Completely isolating the equipment should: switch off the DC switch,
disconnect the DC terminal, and disconnect the AC terminal or AC breaker.
Prohibit inserting or pulling the AC and DC terminals when the inverter is
working.
4
3. Installation
3.1 Mounting Instruction
A In order to achieve optimal performance, the ambient temperature
should be lower than 45 °C.
B For the convenience of checking the LCD display and possible
maintenance activities, please install the inverter at eye level.
C Inverters should NOT be installed near inflammable and explosive items.
Any electro-magnetic equipment should be kept away from installation
site.
D Product label and warning symbol shall be visible after installation.
E Please avoid direct sunlight, rain exposure, snow lay up when installing,
this is better for extending inverter lifetime.
Figure 3.1-1
5
3.2 Unpacking
When you receive Zeus Appollo Solar inverter, please check if there is any
visible external damage on the inverter or any accessories. Please also check
if there is anything missing according to the list below.
Inverter………………………………………………………………………………………………..……… 1
AC junction box…………………..................................…………………………………………1
AC terminal ………………………….………………………………………………………………………6
Positive DC Plug……. …………………... ... ………………………. ... .....…............……...2
Negative DC Plug………………………………………………………………………………..……..…2
USB Data Cable……………………………………………………………………...……………...……1
Expansion Bolt…………………………………………………………………….…………………...…6
Flat Head Screw…………………………………………………………………………….....…………5
Pan Head Screw……………………………………………………………………………………………5
User Manual………………………………………..................................................………..1
Warranty Card……………………………………………………….…………………..….…..1
Lock Plate……………………...……………………………………….………………………..…..….1
Wall-mounted Bracket………………………………………………………………………………….1
Antenna (only for WiFi inverter)………………………………………………………………... 1
Wall-mounted Bracket
Positive DC Plug
Negative DC Plug
AC junction box
6
AC Terminal
USB Data Cable
Expansion Bolt
Flat Head Screw
User Manual
Warranty Card
PV Inverter
Lock Plate
Antenna
(Only for WiFi Mode)
Pan Head Screw
3.3 Equipment Installation
3.3.1 Selecting the installation position
Installation position should be selected based on the following aspects:
The installation method and mounting location must be suitable for the
inverter's weight and dimensions.
Mount on a solid surface.
Select a well ventilated place sheltered from direct sun radiation.
Install vertically or tilted backward by max 15°. The device cannot be
7
installed with a sideways tilt. The connection area must point downwards.
Figure 3.3.1-1
In consideration of heat dissipation and convenient dismantlement, the
minimum clearances around the inverter should be no less than the
following value:
Upward ……………………………………………………………………………….. 300mm
Downward ……………………………………………………………………………….. 500mm
Front ………………………………………………………………………………….. 300mm
Both sides ……………………………………………………………………………….. 500mm
8
Figure 3.3.1-2
9
3.3.2 Mounting Procedure
A Use the wall-mounted bracket as a template and drill 6 holes on the
wall, 10 mm in diameter and 80 mm depth.
Figure 3.3.2-1
B Fix the wall mounting bracket on the wall with six expansion bolts in
accessory bag.
C Carry the inverter by holding the handles shown as below
Figure 3.3.2-2
10
D Place the inverter on the wall-mounted bracket (as illustrated below).
Figure 3.3.2-3
Figure 3.3.2-4
E Fix the inverter with the lock plate in accessory bag (as illustrated below).
1 1
Figure 3.3.2-5
F Use M3*0.5 screw in accessory bag and a padlock to fix the lock plate on
the wall-mounted bracket (as illustrated below)
Figure 3.3.2-6
12
3.4 Electrical Connection
You must comply with the connection requirement of local regulations.
The inverter is integrated with an RCMU according to VDE0126-1-1/A1. It
monitors residual current from the solar module to grid side of inverter. The
inverter can automatically differentiate between fault current and normal
capacitive leakage currents.
It must be included a breaker or a fuse at the AC side, AC breakers nominal
voltage is 400Vac, the melting current is not larger than 16A.
The equipment should have a protective earthing attached to earth
conductor.
3.4.1 Connection to Grid (AC Side Connection)
A Check the grid (utility) voltage and frequency at the connection point of
the inverter. It should be phase to phase 400VAC, 50Hz and three phases.
B Check the rating of branch circuit breaker. For installing one unit of 4-6K
inverters, the recommended breaker rating is 400V/16A.
C Disconnect the breaker or fuse between PV-Inverter and utility.
D Connect the inverter to the grid as follows:
Switch off the AC Breaker.
Strip the AC wire as below specification:
13
Figure 3.4.1-1
Open the output cable connection box, loose and remove the screw cap of
the cable gland. Insert the cable through the screw cap and cable gland as
below figure.
Figure 3.4.1-2
Connect the AC wire as below figure shows:
14
Figure 3.4.1-3
Tighten the cables with a torque of 20kgf.cm (1.9 N.m).
Reconnect the AC junction box to the PV inverter
E Specifications of the AC wires:
AB
C
Figure 3.4.1-
Description
A External diameter of the wire
B Sectional area of conducting materials
C Length of bare wire
Remarks: Specifications of AC cables should be type of H05VV-F or similar.
15
3.4.2 DC Side Connection
A Make sure that the maximum open circuit voltage (Voc) of each PV
string does not exceed the inverter input voltage Vmax under any condition.
B Use Phoenix or Multi-contact connectors for PV array terminals.
C Connect the positive and negative terminals of the PV panel to
corresponding terminals on the inverter. The DC terminal on each inverter
can bear 20A DC current.
Phoenix Contact Connectors
Male side connector (PV+) Female side connector (PV-)
Both types of connectors must be equipped in pair strictly according to above
graphs.
1. Insert the stripped PV conductor.
16
2. Press down on the spring and snap in.
3. Tighten the screw connection. Then the terminal can be
connected to the inverter side.
4. The connection can only be released using a screwdriver
17
Multi-Contact connector
If using Multi-contact connectors for the PV array terminals, install as
follows:
Female side connector (PV+) Male side connector (PV-)
Connectors must be installed as a pair, and each cable stripped and installed
as shown below.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63

Zeus Appollo Z20I4KTL User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document