Smeg SHC965X User manual

Category
Cooker hoods
Type
User manual

Smeg SHC965X is a cooker hood designed for domestic use to eliminate kitchen smells. It can be installed in two modes - ducted or recirculating.

In the ducted mode, the hood is connected to an exhaust flue or duct to expel cooking fumes and odors outside. In the recirculating mode, the hood filters and recirculates the air back into the kitchen.

The hood has three speed settings - low, medium, and high - to adjust the extraction power depending on the cooking intensity. It also features a light to illuminate the cooking area. The metal grease filters are removable and can be cleaned in a dishwasher or by hand. The activated charcoal filters used in recirculating mode need to be replaced every four months.

Smeg SHC965X is a cooker hood designed for domestic use to eliminate kitchen smells. It can be installed in two modes - ducted or recirculating.

In the ducted mode, the hood is connected to an exhaust flue or duct to expel cooking fumes and odors outside. In the recirculating mode, the hood filters and recirculates the air back into the kitchen.

The hood has three speed settings - low, medium, and high - to adjust the extraction power depending on the cooking intensity. It also features a light to illuminate the cooking area. The metal grease filters are removable and can be cleaned in a dishwasher or by hand. The activated charcoal filters used in recirculating mode need to be replaced every four months.

Instruction ManualGB
SHC965X
2
GB
RECOMMENDATIONS AND SUGGESTIONS
INSTALLATION
• The manufacturer will not be held liable for any damages resulting from
incorrectorimproperin-stallation.
• Theminimumsafetydistancebetweenthecookertopandtheextractorhood
is650mm(somemodelscanbeinstalledatalowerheight,pleaserefertothe
paragraphsonworkingdimensionsandinstallation).
• Checkthatthemainsvoltagecorrespondstothatindicatedontheratingplate
xedtotheinsideofthehood.
• For Class I appliances, check that the domestic power supply guarantees
adequateearthing.
Connecttheextractortotheexhaustuethroughapipeofminimumdiameter
120mm.Therouteoftheuemustbeasshortaspossible.
• Donotconnecttheextractorhoodtoexhaustductscarryingcombustionfumes
(boilers,replaces,etc.).
• Iftheextractorisusedinconjunctionwithnon-electricalappliances(e.g.gas
burningappliances),asufcientdegreeofaerationmustbeguaranteedinthe
roominordertopreventthebackowofexhaustgas.Thekitchenmusthave
anopeningcommunicatingdirectlywiththeopenairinordertoguaranteethe
entryofcleanair.Whenthecookerhoodisusedinconjunctionwithappliances
suppliedwithenergyotherthanelectric,thenegativepressureintheroommust
notexceed0,04mbartopreventfumesbeingdrawnbackintotheroombythe
cookerhood.
• Intheeventofdamagetothepowercable,itmustbereplacedbythemanu-
facturerorbythetechnicalservicedepartment,inordertopreventanyrisks.
“WARNING:Failuretoinstallthescrewsorxingdeviceinaccordancewith
theseinstructionsmayresultinelectricalhazards.”
USE
• Theextractorhoodhasbeendesignedexclusivelyfordomesticusetoeliminate
kitchensmells.
• Neverusethehoodforpurposesotherthanforwhichithasbeendesigned.
• Neverleavehighnakedamesunderthehoodwhenitisinoperation.
• Adjusttheameintensitytodirectitontothebottomofthepanonly,making
surethatitdoesnotengulfthesides.
• Deepfatfryersmustbecontinuouslymonitoredduringuse:overheatedoilcan
burstintoames.
• Donotambèundertherangehood;riskofre
• Thisapplianceisnot intendedforusebypersons(includingchildren) with
reducedphysical,sen-soryormentalcapabilities,orlackofexperienceand
knowledge,unlesstheyhavebeengivensu-pervisionorinstructionconcerning
useoftheappliancebyapersonresponsiblefortheirsafety.
• Childrenshouldbesupervisedtoensurethattheydonotplaywiththeappliance.
• WARNING:Accessiblepartsmaybecomehotwhenused with cooking
appliances.”.
MAINTENANCE
• Switchofforunplugtheappliancefromthemainssupplybeforecarryingout
anymaintenancework.
• Cleanand/orreplacetheFiltersafterthespeciedtimeperiod(Firehazard).
• Cleanthehoodusingadampclothandaneutralliquiddetergent.
Thesymbol
ontheproductoronitspackagingindicatesthatthisproductmaynotbetreatedashouseholdwaste.Instead
itshallbehandedovertotheapplicablecollectionpointfortherecyclingofelectricalandelectronicequipment.Byensuring
thisproductisdisposedofcorrectly,youwillhelppreventpotentialnegativeconsequencesfortheenvironmentandhuman
health,whichcouldotherwisebecausedbyinappropriatewastehandlingofthisproduct.Formoredetailedinformationabout
recyclingofthisproduct,pleasecontactyourlocalcityofce,yourhouseholdwastedisposalserviceortheshopwhereyou
purchasedtheproduct.
3
GB
CHARACTERISTICS
Dimensions
Components
Ref. Q.ty Product Components
1 1 Hood Body, complete with: Controls, Light,
Blower, Filters
10 2 Dumper ø150
Ref. Q.ty Installation Components
Q.ty Documentation
1 Instruction Manual
4
GB
INSTALLATION
Drilling the Support surface and Fitting the Hood
TheHoodcanbetteddirectlytotheundersideoftheWallunits(min.650mmabovethecooker
top)withsnap-onsidesupports,whicharesetupforasupportpanelthicknessofbetween15mm
and30mm.
• Cutattedopeninginthebottomsurfaceofthe
wallunit,asshown.
• Removethe metal grease lters (see par. on
Maintenance).
•Removetheltersupport
• Disconnecttheltersupportbyturningtheinternal
handlesprovided.
• Insertthehooduntilthesidesupportssnapinto
place.
• Lockinposition by tightening thescrewsVf
fromunderneaththehood.
•Replacetheltersupport
• Screwtheltersupportusingthe2screws
provided.
• Replacethegreaseltersmakesurethatthe
handleisvisibleontheoutside.




5
GB
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
Wheninstallingtheductedversion,connectthehoodtothechimneyusingarigid150mmduct.
• Installthedamper10ø150mm.
• Fix the duct in position using sufcient pipe
clamps(notsupplied).
RECIRCULATION VERSION AIR OUTLET
• Connect the hood canopy outlet
tothetoppartofthewallunitby
meansofarigidorexiblepipe
ofthesamediameter,thechoice
ofwhichisatthediscretionofthe
installer.
• Fixthepipeinpositionusingsuf-
cientpipeclamps(notsupplied).
•Ensurethattheactivatedcharcoal
ltershavebeeninserted.
ELECTRICAL CONNECTION
• Connectthehoodtothemainsthroughatwo-poleswitchhavingacontactgapofatleast3mm.


Version 03/08 - Page 6
PLAN YOUR DUCTWORK
To ensure that the blower performs to its highest
possible capacity, ductwork should be as short
and straight as possilbe.
The ductrun should not exceed 35 equivalent
feet if ducted using two separate duct runs of
the required minimum of 6" round duct or 55
equivalent feet if ducted with one single 10"
round duct (when using optional Duct Transi-
tion Kit). Calculate the length of the ductwork
by adding the equivalent feet in FIGURE 2 for
each piece of duct in the system An example
is given in FIGURE 3.
For best results, use no more than three 90°
elbows. Make sure that there is a minimum of
24" of straight duct between elbows if more
than one is used. Do not install two elbows
together. If you must elbow right away, do it
as far away from the hood's exhaust opening
as possible.
9 Feet Straight Duct
2 - 90˚ Elbows
Wall Cap
Total System
9.0 feet
10.0 feet
0.0 feet
19.0 feet
3.0 feet
5.0 feet
12.0 feet
0.0 feet
45˚ Elbow
90˚ Elbow
90˚ Flat Elbow
Wall Cap
FIGURE 1
RECIRCULATING INSTALLATIONS
IT IS HIGHLY RECOMMENDED THAT PROFESSIONAL STYLE COOKING ALWAYS BE VENTED TO THE OUTSIDE. For recirculating
installations (FIGURE 1), Charcoal Filters are necessary. Remove all three grease lters and set aside. Attach one charcoal lter to each end
of both blowers. Each charcoal lter attaches to the grid on the side of the blowers. Rotate the lter clockwise to install and counterclockwise
to remove (FIGURE 1A). Replace all three grease lters. Recirculating installations also require some duct work to divert the air out of the
top or face of the cabinet or custom hood. The duct work must not terminate inside the cabinet or custom hood.
cabinet
or
custom
hood
ceiling
duct
work
duct
work
ceiling
inca pro 38
cabinet
or
custom
hood
MAKE YOUR CUT-OUTS
1. Disconnect and move freestanding range from cabinet opening to provide easier access
to upper cabinet or custom hood. Put a thick, protective covering over cooktop, set-in range
or countertop to protect from damage or dirt.
2. Determine and clearly mark with a pencil the center line on the cabinet or custom hood
where the rangehood will be installed.
3. Determine and make all necessary cuts in the wall and/or ceiling for the ductwork. Install
the ductwork before the rangehood.
4. Determine the proper location for the Power Supply Cable. Use a 1
1/4" Drill Bit to make
this hole. Install the cable. Use caulking to seal around the hole. DO NOT turn on the
power until installation is complete.
5. Make the cut-out opening where the rangehood will be installed (FIGURE 4).
FIGURE 4
37"
14 5/8"
CUT-OUT
FIGURE 1A
inca pro 38
FIGURE 2
FIGURE 3
6
GB
USE
Control Panel
KEY FuNctIoNs
L Light Switchesthelightingsystemonandoff.
M Motor Switchestheextractormotoronandoff.
V Speed Setstheoperatingspeedoftheextractor:
1.Lowspeed,usedforacontinuousandsilentairchangeinthepresenceoflight
cookingvapour.
2.Medium speed, suitable for mostoperating conditions given the optimum
treatedairow/noiselevelratio.
3.Maximumspeed,usedforeliminatingthehighestcookingvapouremission,
includinglongperiods.

7
GB
MAINTENANCE
Grease lters
CLEANING METAL SELF- SUPPORTING GREASE FILTERS
• Theltersmustbecleanedeverytwomonthsof
operation,ormorefrequentlywithheavyusage,
andcanbewashedinadishwasher.
• Remove the lters one at a time, supporting
themwithonehandandturningthesafetyknobs
(pullandturn).
• Washthelters,takingcarenottobendthem.
Allowthemtodrybeforeretting.
• Replace them and x them using the safety
knobsprovided(pullandturn).
Odour lters (Recirculation version)
REPLACING THE ACTIVATED CHARCOAL FILTER
• Theseltersarenotwashableandcannotberegenerated,
andmustbereplacedapproximatelyeveryfourmonths
ofoperation,ormorefrequentlywithheavyusage.
• Removethegreaselters.
• Removethesaturatedactivatedcharcoalltersasshown
(A).
• Fitnewlters(B).
• Replacethegreaselters.
Lighting
LIGHT REPLACEMENT
• 35Whalogenlight.
• Removethe2screwsxingthelightcover.
• Remove the lamp by gripping the protruding
partandturningtotheleft.
• Replacewitha newlampwiththesame cha-
racteristics,makingsurethatyouinsertthetwo
pinsproperlyintotheirhousings.
• Replacethecover andxitinposition using
thetwoscrewsremovedasabove
991.0266.699_01 - 120911
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Smeg SHC965X User manual

Category
Cooker hoods
Type
User manual

Smeg SHC965X is a cooker hood designed for domestic use to eliminate kitchen smells. It can be installed in two modes - ducted or recirculating.

In the ducted mode, the hood is connected to an exhaust flue or duct to expel cooking fumes and odors outside. In the recirculating mode, the hood filters and recirculates the air back into the kitchen.

The hood has three speed settings - low, medium, and high - to adjust the extraction power depending on the cooking intensity. It also features a light to illuminate the cooking area. The metal grease filters are removable and can be cleaned in a dishwasher or by hand. The activated charcoal filters used in recirculating mode need to be replaced every four months.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI