18 19
SPECIFICATIONS
MODEL
CAPACITIES
DISPLAYS:
WEIGHT
UNIT PRICE
TOTAL PRICE
MAXIMUM TARE
POWER SOURCE
POWER CONSUMPTION
TEMPERATURE RANGE
PLATTER SIZE(mm)
PRODUCT SIZE(mm)
ERROR MESSAGES
To help the customer’s understanding, this scale warns the error messages
properly. Please refer to error table.
An error of the initial zero range
Failure of returning the normal
mode
An over flow was occurred from
ADD key
An over flow was occurred from
FIX ADD key
An over flow of the transaction count
An over flow of the accumulations of
the daily total functions
Failure of the analog module
Failure of the digital module
Condition codes are broken
Key codes are broken
When you go to non-metric mode
from 100g mode, you had a wrong
operation
1.Set the platter empty
2.Make sure there is a platter on the
scale
Call your CAS dealer
Press C key
Press C key
Press C key
Press C key
Call your CAS dealer
Call your CAS dealer
Call your CAS dealer for span calibration
Call your CAS dealer for span calibration
Press the 100g key and then press the
kg/lb key.
ERROR REASONS SOLUTIONS
Err 1
Err 2
Err 6
Err 7
Err 8
Err 9
Err 10
Err 11
Err 12
Err 13
Err 14
S-2000 Series
15 0.005kg 30 0.01lb
Vacuum Fluorescent Display
5 DIGITS
6 DIGITS
6 DIGITS
-9.995kg -30.00lb
AC 110/120/220/240V, 50/60Hz
APPROX. 10W
10°C 40°C
372(W) 278(D)
478(W) 365(D) 495(H)