horsch LEEB GS Short Instruction

Type
Short Instruction

This manual is also suitable for

Art.: 80900223
Short Instruction for Filling LEEB LT and GS
Variant CCS Pro
1. Start the tractor
¾ Set the diesel speed to approx. 1500 rpm.
2. Open left side cover, connect suction hose
with lling connection and open lling valve.
Filling connection
Filling valve
The illustration
shows:
Leeb LT
3. On the external control terminal
¾ Enter the lling limit
¾ Start lling
Stop
Start lling
Conrm
Navigate up/down
Enter the lling
limit
Filling stops automatically when the desired
value has been reached. Interruption via the
stop button is possible at any time.
4. Close the lling valve, take o suction hose
and close side cover.
NOTE
The short instruction for the operation of the machine is only to be used with observation of the
safety and warning notes of the pertaining operating instructions. Compensation claims for dam-
ages due to non-observance of the operating instructions are excluded.
Art.: 80900223
Short Instruction for Filling LEEB LT and GS Variant CCS
1. Start the tractor
¾ Set the diesel speed to approx. 1500 rpm.
2. Open left side cover, connect suction hose
with lling connection and open lling valve.
Filling connection
Filling valve
The illustration
shows:
Leeb LT
3. Set the ball valve on the suction and pressure
side to lling.
Ball valve
pressure side
Ball valve
suction side
4. On the terminal
¾ Enter the lling limit
¾ Start lling
Stop
Filling
start
pulling suction
Filling limit
enter
Filling stops automatically when the desired
value has been reached. Interruption via the
stop button is possible at any time.
¾ Or start lling (without lling limit) by switching
on the pump on the external control terminal
Mini. Interruption is possible at any time by
switching o the pump.
Switch on the pump
5. Close the lling valve, take o suction hose
and close side cover.
NOTE
The short instruction for the operation of the machine is only to be used with observation of the
safety and warning notes of the pertaining operating instructions. Compensation claims for dam-
ages due to non-observance of the operating instructions are excluded.
Short Instruction for Filling LEEB LT and GS Variant ECO
1. Open left side cover, connect suction hose
with lling connection and open lling valve.
Filling connection
Filling valve
The illustration
shows:
Leeb LT
2. Set the ball valve on the suction and pressure
side to lling.
Ball valve
pressure side
Ball valve
suction side
3. Start the tractor
¾ Turn on the PTO-shaft with approx. 540 rpm.
4. Observe the lling level of the solution tank
and turn o the PTO-shaft when the desired
lling level or the rated volume have been
reached. Interruption is possible at any time
by switching o the PTO-shaft.
Solution tank
lling level
5. Close the lling valve, take o suction hose
and close side cover.
NOTE
The short instruction for the operation of the machine is only to be used with observation of the
safety and warning notes of the pertaining operating instructions. Compensation claims for dam-
ages due to non-observance of the operating instructions are excluded.
Art.: 80900223
Art.: 80900223
Short Instruction for Spraying LEEB LT and GS
Variant ECO, CCS and CCS Pro
NOTE
The short instruction for the operation of the machine is only to be used with observation of the
safety and warning notes of the pertaining operating instructions. Compensation claims for dam-
ages due to non-observance of the operating instructions are excluded.
1. Filling the machine
2. Machines of the ECO and CCS variants:
Set the ball valve on the suction side to solu-
tion tank and the ball valve on the pressure
side to circulation/spraying.
Ball valve
pressure side
Ball valve
suction side
3. Start the tractor
¾ ECO variant: Switch on the PTO-shaft.
¾ Variants CCS and CCS Pro: Set the diesel
speed to approx. 1500 rpm.
4. Touch and hold the Unfold button on the folding
menu until the folding boom has fully unfolded.
Folding menu
Folding
Unfolding
5. Adjusting the working height of the spraying boom
6. Enter l/ha setpoint
7. Check the value “min. pressure” and “max. pres-
sure” for the permissible spraying pressure range.
8. Activate the folding boom control
9. Switch on circulation
Main control page
l/ha setpoint
Folding menu
Circulation
on/o
Folding boom control
on/o
Spraying
on/o
10. Switch on main sprayer switch
Main spraying
switch