Preface 1
TEN100 Series
Hardened Unmanaged 8-port Fast
Ethernet Switch
User’s Manual
ii
Disclaimers
This manual has been carefully checked and believed to contain accurate information.
Axiomtek Co., Ltd. assumes no responsibility for any infringements of patents or any third
partys rights, and any liability arising from such use.
Axiomtek does not warrant or assume any legal liability or responsibility for the accuracy,
completeness, or usefulness of any information in this document. Axiomtek does not make any
commitment to update the information in this manual.
Axiomtek reserves the right to change or revise this document and/or product at any time
without notice.
No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any
form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without
the prior written permission of Axiomtek Co., Ltd.
CAUTION
If you replace wrong batteries, it causes the danger of explosion. It is recommended by the
manufacturer that you follow the manufacturers instructions to only replace the same or
equivalent type of battery and dispose of used ones.
©Copyright 2023 Axiomtek Co., Ltd.
All Rights Reserved
September 2023, Version A2
Printed in Taiwan
iii
Table of Contents
Disclaimers ................................................................................................................................. ii
Section 1 Preface .................................................... 1
Section 2 Block Diagram ......................................... 3
Section 3 Dimensions .............................................. 4
Section 4 Product Overview .................................... 5
4.1 Industrial Ethernet Switch ............................................................................................. 5
4.2 Package Contents ........................................................................................................ 5
4.3 Product Highlights......................................................................................................... 6
4.3.1 Basic Features ............................................................................................ 6
4.4 Front Panel Display ...................................................................................................... 7
4.4.1 Power Status (PWR) ................................................................................... 7
4.4.2 Port Status LEDs ......................................................................................... 7
4.5 Physical Ports ............................................................................................................... 8
Section 5 Installation .............................................. 9
5.1 Selecting a Site for the Switch ...................................................................................... 9
5.2 DIN Rail Mounting......................................................................................................... 9
5.2.1 Assembly, Startup, and Dismantling ......................................................... 10
5.3 Connecting to Power .................................................................................................. 10
5.3.1 DC Terminal Block Power Inputs ............................................................... 10
5.4 Connecting to Your Network ........................................................................................ 11
5.4.1 Cable Type & Length .................................................................................. 11
5.4.2 Cabling ...................................................................................................... 12
Section 6 Specifications ....................................... 13
Appendix A Connector Pinouts ................................. 15
ii
This page is intentionally left blank.
TEN100-0800-H Series User’s Manual
Preface 1
Section 1
Preface
A member of the growing family of rugged switches, this switch addresses a need for a
smaller switch. This switch provides an affordable solution for rugged and outdoor
environment, transportation road-side cabinet, industrial floor shop, multitenant dwellings or
Fiber To The Home (FTTH) applications. Capable of operating at temperature extremes of
-40°C to +75°C, this is the switch of choice for harsh environments constrained by space.
Plug-and-Play Solution:
The switch is a plug-and-play Fast Ethernet Switch in compact size. It doesn't have any
complicated software to set up.
This manual describes how to install and use the Industrial Ethernet Switch. This switch
integrates full wire speed switching technology. This switch brings the answer to complicated
hardened networking environments.
To get the most out of this manual, you should have an understanding of Ethernet networking
concepts.
In this manual, you will find:
Features on the switch
Illustrative LED functions
Installation instructions
Specifications
TEN100-0800-H Series User’s Manual
2 Preface
This page is intentionally left blank.
TEN100-0800-H Series User’s Manual
Block Diagram 3
Section 2
Block Diagram
TEN100-0800-H Series User’s Manual
4 Dimensions
Section 3
Dimensions
TEN100-0800-H Series User’s Manual
Product Overview 5
Section 4
Product Overview
4.1 Industrial Ethernet Switch
4.2 Package Contents
When you unpack the product package, you shall find the items listed below. Please inspect
the contents, and report any apparent damage or missing items immediately to your authorized
reseller.
🗸This Switch
🗸User’s Manual
TEN100-0800-H Series User’s Manual
6 Product Overview
4.3 Product Highlights
4.3.1 Basic Features
Complies with EN61000-6-2 & EN61000-6-4 EMC Generic standard immunity for
industrial environment.
Supports IEEE802.3az 10Base-Te and 10Base-T. 10Base-Te is fully interoperable
with 10Base-T over 100m of class D (Category 5) or better cabling as specified in
ISO/IEC 11801:1995.
Supports 802.3/802.1p/802.3az/802.3u. Auto-negotiation: 10/100Mbps, Full/Half-
duplex. Auto MDI/MDIX.
Supports 2K MAC addresses, 768K bits buffer memory.
IEEE802.3x Flow control for Full-duplex, Back pressure for Half-duplex.
None-blocking architecture and full wire-speed forwarding rate.
The IEEE802.1p QoS feature is supported and automatically activated when
the switch is running. Priority mapping is handled according to the following
tables:
CoS priority
(802.1p)
7, 6, 5, 4
3, 2, 1, 0
Queues
1
0
WRR
16
1
Supports IEEE802.3az Energy Efficient Ethernet (EEE).
Power consumption: 3.4W Max.
Power Supply: DC Terminal Block power input, 12-48VDC (9-55VDC)
(Terminal Block)
Operating temperature ranges from -40°C to 75°C (-40°F to 167°F).
DIN rail mountable metal housing provides security and easy installation
(mounting kit is included).
TEN100-0800-H Series User’s Manual
Product Overview 7
4.4 Front Panel Display
4.4.1 Power Status (PWR)
This LED comes on when the switch is properly connected to power and turned on.
4.4.2 Port Status LEDs
The LEDs display status for each respective port.
LED
Color
Status
L/A
(Link/Active)
Green
LED On: Link
LED Off: No Link
LED blinking: Data Transmission
PWR 1&2
Green
LED On: Power On
LED Off: Power Off
Alarm
Red
LED On: Error Power Redundancy
Detection
LED Off: No Power Error Condition
TEN100-0800-H Series User’s Manual
8 Product Overview
4.5 Physical Ports
This switch provides:
Eight 10/100Base-TX ports
Connectivity
RJ-45 connectors
TEN100-0800-H Series User’s Manual
Installation 9
Section 5
Installation
This chapter gives step-by-step instructions about how to install the switch:
5.1 Selecting a Site for the Switch
As with any electric device, you should place the switch where it will not be subjected to extreme
temperatures, humidity, or electromagnetic interference. Specifically, the site you select should
meet the following requirements:
The ambient temperature should be between -40 to 75 degrees Celsius.
The relative humidity should be less than 95 percent, non-condensing.
Surrounding electrical devices should not exceed the electromagnetic field (RFC)
standards.
Make sure that the switch receives adequate ventilation. Do not block the ventilation
holes on each side of the switch.
The power outlet should be within 1.8 meters of the switch.
5.2 DIN Rail Mounting
Installation: Place the switch on the DIN rail from above using the slot. Push the front of the
switch toward the mounting surface until it audibly snaps into place.
Removal: Pull out the lower edge and then remove the switch from the DIN rail.
TEN100-0800-H Series User’s Manual
10 Installation
5.2.1 Assembly, Startup, and Dismantling
Assembly: Place the Switch on the DIN rail from above using the slot. Push the front of the
Switch toward the mounting surface until it audibly snaps into place.
Startup: Connect the supply voltage to start up the device via the terminal block.
Dismantling: Pull out the lower edge and then remove the device from the DIN rail.
5.3 Connecting to Power
5.3.1 DC Terminal Block Power Inputs
Step 1: Connect the DC power cord to the plug-able terminal block on the switch, and then
plug it into a standard DC outlet.
Step 2: Disconnect the power cord if you want to shut down the switch.
Description
Power 1
+
9-55VDC
Power Ground
Power 2
+
9-55VDC
Power Ground
Earth Terminal
0.5A @30VDC
TEN100-0800-H Series User’s Manual
Installation 11
Relay Output Alarm
The switch provides a relay output contact. The relay is for signaling of a user- defined power
redundancy failure. The current is 0.5A@30VDC at Normal Open or Normal Close.
Power-Up Sequence
All Link/ACT LEDs blink momentarily.
The Power 1 LED light goes ON.
LEDs for every port connected to a device will flash, as the switch conducts a brief
Power On Self-Test (POST).
Power wiring information:
Use copper conductors only.
Use cable type AWG (American Wire Gauge) 18-22 and corresponding pin type cable
terminals.
The rating of the power wire used must be at least 105°C.
5.4 Connecting to Your Network
5.4.1 Cable Type & Length
It is necessary to follow the cable specifications below when connecting the switch to your
network. Use appropriate cables that meet your speed and cabling requirements.
Cable Specifications
Speed
Connector
Port Speed
Half/Full
Duplex
Cable
Max. Distance
10Base-Te
RJ-45
10/20 Mbps
2-pair
UTP/STP
Cat. 5
100 m
100Base-TX
RJ-45
100/200 Mbps
2-pair
UTP/STP
Cat. 5
100 m
POWER1
INPUT
POWER2
INPUT
RELAY contact
X
X
Open, Start alarm
O
X
Open, Start alarm
X
O
Open, Start alarm
O
O
Close, Non-alarm
TEN100-0800-H Series User’s Manual
12 Installation
5.4.2 Cabling
Step 1: First, ensure the power of the switch and end devices are turned off.
<Note> Always ensure that the power is off before any installation.
Step 2: Prepare cable with corresponding connectors for each type of port in use.
<Note> To connect two regular RJ-45 ports between switches or hubs, you need a
straight or cross-over cable.
Step 3: Consult the previous section for cabling requirements based on connectors and
speed.
Step 4: Connect one end of the cable to the switch and the other end to a desired device.
Step 5: Once the connections between two end devices are made successfully, turn on the
power and the switch is operational.
TEN100-0800-H Series User’s Manual
Specifications 13
Section 6
Specifications
Industrial Ethernet
Switch
10/100Base-TX auto-negotiating ports with RJ-45 connectors
Applicable
Standards
IEEE 802.3u 100Base-TX/FX
IEEE 802.3x Full-duplex Flow Control IEEE802.3az Energy
Efficient Ethernet
IEEE 802.1p Quality of Series (QoS)
Forwarding Rate
10Base-Te:
100Base-TX:
10 / 20Mbps half / full-duplex
100 / 200Mbps half / full-duplex
Performance
14,880pps for 10Mbps
148,810pps for 100Mbps
Cable
10Base-Te:
100Base-TX:
2-pair UTP/STP Cat. 5
2-pair UTP/STP Cat. 5 Up to 100m (328ft)
Dimensions
45mm (W) × 75mm (D) × 100mm (H) (1.77 (W) × 2.95 (D) ×
3.94 (H))
Net Weight
336g (0.74lb.)
Power
12-48VDC (9-55VDC) (Terminal Block)
Power Consumption
3.4W Max.
Operating
Temperature
-40°C to 75°C (40°F to 167°F)
Storage
Temperature
-40°C to 85°C (-40°F to 185°F)
Humidity
5%-95% non-condensing
EMI
FCC Part 15, Class A
EN61000-6-4;
EN 55032;
ICES-003
EMS
EN61000-6-2:
EN61000-4-2 (ESD Standard)
EN61000-4-3 (Radiated RFI Standards)
EN61000-4-4 (Burst Standards)
EN61000-4-5 (Surge Standards)
EN61000-4-6 (Induced RFI Standards)
EN61000-4-8 (Magnetic Field Standards)
Environmental Test
Compliance
Vibration Resistance: IEC60068-2-6 Fc
Shock: IEC60068-2-27 Ea
Free Fall: IEC60068-2-32 Ed
Free Fall: FED STD 101C Method 5007.1 (by
CARTON)
TEN100-0800-H Series User’s Manual
14 Specifications
This page is intentionally left blank.
TEN100-0800-H Series User’s Manual
Connector Pinouts 15
Appendix A
Connector Pinouts
Pin arrangement of RJ-45 connectors:
The following table lists the pinout of 10/100Base-TX ports.
Pin
Regular Ports
Uplink port
1
Output Transmit Data +
Input Receive Data +
2
Output Transmit Data -
Input Receive Data -
3
Input Receive Data +
Output Transmit Data +
4
NC
NC
5
NC
NC
6
Input Receive Data -
Output Transmit Data -
7
NC
NC
8
NC
NC
RJ-45 Connector and Cable Pins
TEN100-0800-H Series User’s Manual
16 Connector Pinouts
This page is intentionally left blank.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

AXIOMTEK TEN100-0800-H User manual

Category
Network switches
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI