Anybus abc4016, abc4011, abc4012, abc4013, abc4014, abc4017, abc4018, abc4020, abc4021, abc4023 Quick start guide

  • Hello! I am an AI chatbot trained to assist you with the Anybus abc4016 Quick start guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Replace X-gateway with Communicator Quick Guide
About this Quick Guide
This Quick Guide describes how to transit the conguraon from an X-gateway to a new generaon Communicator.
For in-depth informaon about how to install and congure the Communicator, see the product user manual.
See Support and Resources (page 1).
Support and Resources
For addional documentaon and soware downloads, FAQs, troubleshoong guides and technical support, please
visit www.anybus.com/support.
TIP
Have the product arcle number available, to search for the product specic support web page. You
nd the product arcle number on the product cover.
HMS Soware Applicaons
Download the soware installaon les and user documentaon from www.anybus.com/support.
Anybus Conguraon Manager - X-gateway
Use the soware applicaon Anybus Conguraon Manager - X-gateway to congure the classic Anybus
Communicator and the Anybus X-gateway.
HMS IPcong
Use the soware applicaon HMS IPcong and scan your network to discover and change the Communicator IP
address and to access the Communicator built-in web interface.
NOTE
As an alternave, you can set a stac IP address within the same IP address range as the Communicator
IP address on the computer accessing the Communicator built-in web interface.
NOTE
HMS IPcong is only available for Windows.
Replace X-gateway with Communicator Quick Guide
© 2023 HMS Networks
SCM-1202-215 / 1.0 / 2023-03-13 Page 1 of 10
Communicator Built-In Web Interface Overview
Use the Communicator built-in web interface to congure, maintain and troubleshoot the Communicator.
Figure 1. The Communicator built-in web interface Home page example
Menu item Descripon
Home View the Communicator, network, and node status.
Apply Aer conguraon changes are made and veried, press Apply to make the sengs take eect.
Conguraon, upper network page Congure network sengs.
Conguraon, lower network page Congure network sengs.
I/O conguraon Congure input and output data sizes and endian conversion.
Files & rmware Save sengs in a conguraon les, upload conguraon les and upgrade rmware.
Diagnoscs Monitor and troubleshoot the Communicator.
Support Contains Communicator product informaon, Anybus contact informaon, link to Anybus support
website, and product le for download.
Here you can generate a support package with product informaon, to send to your Anybus support
technician.
For in-depth informaon about how to install and congure the Communicator, see the product user manual.
See Support and Resources (page 1).
Replace X-gateway with Communicator Quick Guide
Page 2 of 10
© 2023 HMS Networks
SCM-1202-215 / 1.0 / 2023-03-13
Transit the X-gateway Conguraon
Before You Begin
The X-gateway is congured via the soware applicaon Anybus Conguraon Manager X-gateway.
The Communicator is congured via a built-in web interface.
To transit from an X-gateway to a Communicator, you need to:
1. Overview the exisng conguraon sengs in the Anybus Conguraon Manager X-gateway.
2. Redo the conguraon in the Communicator built-in web interface.
Replace X-gateway with Communicator Quick Guide
© 2023 HMS Networks
SCM-1202-215 / 1.0 / 2023-03-13 Page 3 of 10
Find the Communicator on Your PC
The Communicator default IP address is 192.168.0.10.
To be able to access the Communicator built-in web interface you may need to adjust the IP sengs, choose one of
the following methods:
Opon 1 | Set a stac IP address on the PC
On the PC accessing the Communicator built-in web interface, set a stac IP address
within the same IP address range as the Communicator IP address.
To access the Communicator built-in web interface, ensure that port Port 80 TCP is open
in your PC Windows Firewall.
Note that when you change to a stac IP address on your PC, internet access is lost.
Opon 2 | Change the IP address on the Communicator conguraon port
Use the soware applicaon HMS IPcong to nd and change the IP address on the
Communicator conguraon port, to one within the same IP address range as the PC
accessing the Communicator built-in web interface.
To download the installaon les, please visit www.anybus.com/support and enter the
product arcle number to search for the Communicator support web page. You nd the
product arcle number on the product cover.
Replace X-gateway with Communicator Quick Guide
Page 4 of 10
© 2023 HMS Networks
SCM-1202-215 / 1.0 / 2023-03-13
Access the Communicator Built-In Web Interface
1. Connect the Communicator to your PC and to power.
Figure 2. Communicator conguraon port and power connector
2. Open a web browser and enter the Communicator IP address in the Address bar.
The Communicator default IP address is 192.168.0.10.
The Communicator built-in web interface Home page appears.
Figure 3. Communicator built-in web interface, Home page example
Replace X-gateway with Communicator Quick Guide
© 2023 HMS Networks
SCM-1202-215 / 1.0 / 2023-03-13 Page 5 of 10
Access the X-gateway Conguraon in the Conguraon Manager
1. Connect the X-gateway conguraon port to your PC and to power.
2. Start the Anybus Conguraon Manager - X-gateway.
3. In the main menu, click Connect.
The conguraon manager searches for the X-gateway.
4. Upload the excising X-gateway conguraon or open a saved conguraon.
5. In the Project menu, select the upper network interface.
View the conguraon sengs to be used in the new Communicator.
Example 1. In this example we use an PROFINET IO - EtherNet/IP X-gateway.
Figure 4. X-gateway Project with the PROFINET IO (Upper) network selected
Replace X-gateway with Communicator Quick Guide
Page 6 of 10
© 2023 HMS Networks
SCM-1202-215 / 1.0 / 2023-03-13
Upper Network Page Sengs
NOTE
The IP sengs vary depending on the network protocol type.
Example 2. Communicator built-in web interface, Conguraon menu with the upper network page selected
Figure 5. Conguraon, PROFINET page example
In the Communicator built-in web interface:
1. Navigate to the Conguraon menu and select the upper network page.
NOTE
For some X-gateway variants, the upper network corresponds to the lower network for the
Communicator.
2. Congure the IP Sengs according to the sengs in the Anybus Conguraon Manager - X-gateway
conguraon.
3. Opon for PROFINET: In PROFINET sengs, enter the PROFINET Staon Name.
4. Download the conguraon le to your computer for use in your PLC programming tool.
Depending on the network protocol, one of the following le formats is available for download: GSDML, GSD,
EDS, or ESI.
Replace X-gateway with Communicator Quick Guide
© 2023 HMS Networks
SCM-1202-215 / 1.0 / 2023-03-13 Page 7 of 10
Lower Network Page Sengs
Connue to congure the second network.
1. In the Anybus Conguraon Manager - X-gateway Project menu:
Select the lower network interface.
View the conguraon sengs to be used in the new Communicator.
Example 3. In this example we use an PROFINET IO - EtherNet/IP X-gateway
Figure 6. X-gateway Project with the EtherNet/IP + Modbus-TCP + WEB Slave + IT 2-port (Lower) network
selected
Replace X-gateway with Communicator Quick Guide
Page 8 of 10
© 2023 HMS Networks
SCM-1202-215 / 1.0 / 2023-03-13
2. In the Communicator built-in web interface:
Navigate to the Conguraon menu and select the lower network page.
NOTE
For some X-gateway variants, the lower network corresponds to the upper network for the
Communicator.
Example 4. Communicator built-in web interface, Conguraon menu with the lower network page selected
Figure 7. Conguraon, EtherNet/IP page
3. Congure the IP sengs and Connecon sengs according to the sengs in the Anybus Conguraon
Manager - X-gateway conguraon.
4. Download the conguraon le to your computer for use in your PLC programming tool.
Depending on the network protocol, one of the following le formats is available for download: GSDML, GSD,
EDS, or ESI.
Replace X-gateway with Communicator Quick Guide
© 2023 HMS Networks
SCM-1202-215 / 1.0 / 2023-03-13 Page 9 of 10
I/O Conguraon
Connue with the I/O conguraon.
In this example we use an PROFINET to EtherNet/IP .
Figure 8. I/O conguraon page
1. On the I/O conguraon page, enter the same I/O sizes, for the Upper and Lower network, as in the old
X-gateway conguraon.
2. If applicable, enable Endian swapping in either direcon.
Set a swapping type to use for the enre area or use Detailed swap to set dierent types of swapping for
dierent parts of the I/O area.
Replace X-gateway with Communicator Quick Guide
Page 10 of 10
© 2023 HMS Networks