COLUMBIA BOILER COMPANY, REV 2-17
- 15 -
BURNER START UP AND TEST INFORMATION: REQUIRED
For a new boiler start up, or for troubleshooting an existing installation, the following infor-
mation is essential for effective service assistance.
Boiler Model__________________ Serial No.______________ N.B. No._______________
Burner Model_________________ Invoice No._____________ Serial No.______________
In
stallation N
ame______________________________________ Start Up Date____________
Start Up Contractor____________________________________ Phone No.______________
Name of Technician Performing Start Up__________________________________________
Fuel Type: q Natural Gas q LP Gas q Fuel Oil (#2) q Other_____________________
Gas Firing
Gas Pressure At Train Inlet
Burner in Off Position________"W.C.
Gas Pressure At Train Inlet
High Fire__________________"W.C.
Gas Pressure At Main Orifice
High Fire__________________"W.C.
Gas Pressure At Pilot Orifice
__________________________"W.C.
Oil Firing
High Fire Vacuum Reading At Oil
Pump Inlet__________________"H.G.
Oil Nozzle Supply Pressure
Low Fire______________________PSI
High Fire_______
______________PSI
F
iring Rate - GPH
Low Fire________________________
High Fire_______________________
Operational Check of Controls
Operating Limit_________________q
Safety Limit____________________q
Low Water Cut Off______________q
Flame Signal Readings
Pilot____________________________
CO2
High Fire________________________
CO
High Fire________________________
Measured INput Rate - BTU/HR
High Fire ____________
______"W.
C.
CO2
Low Fire ________________________
High Fire________________________
Bachrach Scale Smoke Number
Low Fire ________________________
High Fire________________________
Over Fire Draft
Low Fire___________________"W.C.
High Fire __________________"W.C.
Aux LWCO ____________________q
Low Gas Pressure ______________q
High Gas Pressure ______________q
Stack Outlet Test Point Draft
High Fire _____________
_____"W.
C.
Over Fire Draft
High Fire __________________"W.C.
Net Stack Temperature
High Fire______________________°F
Gas Pressure At Pilot Orifice
__________________________"W.C.
Stack Outlet Test Point Draft
Low Fire___________________"W.C.
High Fire__________________"W.C.
New Stack Temperature
Low Fire______________________°F
High Fire_____________________°F
Flame Safeguard _______________q
Ignition Failure
q
F
lame Failure q
Comments
________________________________________________________________________________________________________
________________________________________________________________________________________________________
________________________________________________________________________________________________________
________________________________________________________________________________________
________________
_
_______________________________________________________________________________________________________
________________________________________________________________________________________________________
________________________________________________________________________________________________________