Sherwood meridian series User manual

Category
Stoves
Type
User manual

This manual is also suitable for

OMNI-Test Laboratories, Inc.
EPA Standard of Performance for New Residential Wood Heaters
Certification Test Report
Non-Confidential Business Information
Non-(CBI)
Manufacturer: Sherwood Industries, Ltd
Heater Type: Pellet-Fired, Freestanding or Insert
Model Line: Meridian Series
Models: Meridian-1, Meridian FPI, Meridian Cast Iron, GF55,
GFI55
Prepared for: Sherwood Industries, Ltd.
6782 Oldfield Road
Saanichton, British Columbia V8M 2A3
Canada
Prepared by: OMNI-Test Laboratories, Inc.
13327 NE Airport Way
Portland, OR 97230
(503) 643-3788
Test Period: January 11, 2018
Report Date: September 13, 2018
Report Number: 0268PM025E
All data and information contained in this report are confidential and proprietary to Sherwood
Industries. Its significance is subject to the adequacy and representative character of the
samples and to the comprehensiveness of the tests, examinations, or surveys made. The
contents of this report cannot be copied or quoted, except in full, without specific, written
authorization from Sherwood Industries and OMNI-Test Laboratories, Inc. No use of the
OMNI-Test Laboratories, Inc. name, logo, or registered mark (O-TL) is permitted, except as
expressly authorized by OMNI-Test Laboratories, Inc. in writing.
Sherwood Industries, Ltd
Models: Meridian-1, Meridian FPI, Meridian Cast Iron, GF55, GFI55
Report Number:0261PF026E
OMNI-Test Laboratories, Inc.
AUTHORIZED SIGNATORIES
This report has been reviewed and approved by the following authorized signatories:
Evaluator:
___________________________
Aaron Kravitz
OMNI-Test Laboratories, Inc.
QA Review:
___________________________
Ken Morgan
Testing Manager
______________
Issue Date
9/13/2018
Sherwood Industries, Ltd
Models: Meridian-1, Meridian FPI, Meridian Cast Iron, GF55, GFI55
Report Number:0261PF026E
OMNI-Test Laboratories, Inc.
TABLE OF CONTENTS
PREFACE ............................................................................................................... (3 pages)
Section 1 Appliance, Testing, & Results ....................................................................................4
1.1 Appliance Description ...................................................................................................5
1.2 Procedures & Results Summary ....................................................................................7
1.3 Summary Tables ............................................................................................................9
Table 1 Particulate Emissions ................................................................................9
Table 2 Efficiency and CO ....................................................................................9
Table 3 Test Facility Conditions ..........................................................................10
Table 4 Fuel Measurement Summary ..................................................................10
Table 5 Dilution Tunnel and Flue Gas Measurements ........................................11
Table 6 Heater Configuration ..............................................................................11
Section 2 Test Data....................................................................................................................12
2.1 Test Data by Run .........................................................................................................13
2.2 Sample Analysis & Tares.............................................................................................28
Section 3 Laboratory Quality Assurance .................................................................................35
3.1 Quality Assurance/Quality Control..............................................................................36
3.2 Calibration Data ...........................................................................................................37
3.3 Example Calculations ..................................................................................................54
Appendix A Labeling & Owner’s Manual
Sherwood Industries, Ltd
Models: Meridian-1, Meridian FPI, Meridian Cast Iron, GF55, GFI55
Report Number:0261PF026E
OMNI-Test Laboratories, Inc.
Section 1
Appliance, Testing, & Results
1.1 - Appliance Description
1.2 Procedures and Results Summary
1.3 - Summary Tables
4 of 194
4 of 194
Sherwood Industries, Ltd
Models: Meridian-1, Meridian FPI, Meridian Cast Iron, GF55, GFI55
Report Number:0261PF026E
OMNI-Test Laboratories, Inc.
1.1 - Appliance Description
Appliance Manufacturer: Sherwood Industries
Pellet Stove Model Line: Meridian Series
Model Names: Meridian-1, Meridian FPI, Meridian Cast Iron, GF55, GFI55
Model Similarity: The sample unit tested is a model Meridian-1; one of the freestanding models
of the model line. The fireplace insert models of the Meridian Series are identical to the
freestanding versions in all interior parts and configurations. All critical components, air flow
pathways, and K List items (aside from overall stove dimensions) are identical between the two
versions.
Type: Freestanding and fireplace insert, air-circulating type, pellet-fired room heater.
The Meridian Series principle elements include a fuel hopper, grey cast iron firebox chamber,
ductile iron burn pot, and electrical fuel feed, combustion air, and convection air supply systems.
The frame of the unit is constructed of mild steel, as is the outer fascia and door.
Combustion products are routed out of the firebox chamber via a baffle-type heat exchanger
through a 3-inch diameter flue outlet located on the rear of the unit.
Fuel is supplied from the hopper to the burn pot via a screw-type auger. Fuel supply rate is
varied by cycling the auger motor as needed.
Ashes fall through the burn pot into a removable ash drawer located at the bottom of the unit.
The drawer is accessed through the front firebox door, which also features a 14” x 21” glass
panel.
The electrical systems are regulated by a user-operated control board featuring up/down buttons
to achieve desired heat output. The unit can also be controlled by an external thermostat system.
More detailed information is shown in the manufacturer’s design drawings, Appendix C of this
report. This information is considered confidential business information (CBI) by the
manufacturer and is not included in the non-CBI version of this report.
5 of 194
5 of 194
Sherwood Industries, Ltd
Models: Meridian-1, Meridian FPI, Meridian Cast Iron, GF55, GFI55
Report Number:0261PF026E
OMNI-Test Laboratories, Inc.
Appliance Photographs
Meridian Series
Test Date: 1/11/2018
Meridian Series Front
Meridian Series Back
Meridian Series Left
Meridian Series Right
6 of 194
6 of 194
Sherwood Industries, Ltd
Models: Meridian-1, Meridian FPI, Meridian Cast Iron, GF55, GFI55
Report Number:0261PF026E
OMNI-Test Laboratories, Inc.
1.2 - Procedures and Results Summary
INTRODUCTION
Sherwood Industries retained OMNI-Test Laboratories, Inc. (OMNI) to perform
U.S. Environmental Protection Agency (EPA) certification testing on the Meridian Series. The
Meridian Series is a freestanding or insert style pellet-burning residential heating appliance.
The testing was performed at OMNI’s testing facility in Portland, Oregon. The altitude of the
laboratory is 30 feet above sea level. The unit was received in good condition and logged in at
the OMNI’s testing facility on January 10, 2018. It was assigned and labeled with OMNI ID
#2263. OMNI representative Aaron Kravitz conducted the certification testing and completed all
testing by January 11, 2018.
This report is organized in accordance with the EPA-recommended outline and is summarized in
the Table of Contents immediately preceding this section. The results in this report are limited to
the item(s) submitted.
SUMMARY OF RESULTS
The average particulate emission rate over the complete, integrated test run was measured to be
0.89 g/hr.
The average particulate emission factor for the complete, integrated test run was measured to be
1.01 g/dry kg of fuel.
The average thermal efficiency for the complete, integrated test run was measured to be 69.7%.
The particulate emission rate calculated from the one-hour filter was 0.81 g/hr.
The proportionality results and sample train agreement for the test run was acceptable. Quality
check results for each test run are presented in Section 3 of this report.
7 of 194
7 of 194
Sherwood Industries, Ltd
Models: Meridian-1, Meridian FPI, Meridian Cast Iron, GF55, GFI55
Report Number:0261PF026E
OMNI-Test Laboratories, Inc.
1.2 - Procedures and Results Summary
TESTING PROCEDURE
The Meridian Series was tested in accordance with the U.S. EPA 40 CFR Part 60, Subpart AAA
Standards of Performance for New Residential Wood Heaters using ASTM E2515 and ASTM
E2779. The fuel used for certification testing was Lignetics brand densified wood pellet fuel; this
fuel was graded as Premium by the Pellet Fuels Institute and was produced at registered mill #
03208. Particulate emissions were measured using dual sampling trains consisting of two sets of
filters (front and back).
The unit was installed and adjusted in accordance with the manufacturer’s instructions, adjusting
an air inlet slide to achieve a static pressure of 0.13 inches of water after 30 minutes at maximum
burn rate. This slide was fixed in place throughout the integrated test run
The results of the integrated test run indicate an average particulate emission rate of 0.89 g/hr.
The Meridian Series results are within the emission limit of 2.0 g/hr for affected appliances
manufactured on or after May 15, 2020 or sold at retail after December 31, 2020.
The model Meridian Series was tested for thermal efficiency and carbon monoxide (CO)
emissions in accordance with CSA B415.1-10. The heater has a demonstrated an average thermal
efficiency of 69.7%. The calculated CO emission rate was 0.07 g/min.
Upon completion of emissions certification testing, the sample unit was sealed and will be stored
by the manufacturer in accordance with the requirements of the CFR.
Meridian Series Sealed Test Unit
8 of 194
8 of 194
Sherwood Industries, Ltd
Models: Meridian-1, Meridian FPI, Meridian Cast Iron, GF55, GFI55
Report Number:0261PF026E
OMNI-Test Laboratories, Inc.
1.3 - Summary Tables
Table 1 Particulate Emissions
Emission Rate
(g/hr)
Emission Factor
(g/dry kg)
Table 2 Efficiency and CO
Burn Rate Segment
Integrated
Total
Maximum
Medium
Minimum
Time
(minutes)
61
120
180
361
Burn Rate
(dry kg/hr)
1.75
0.85
0.62
0.89
Heat Input Rate
(BTU/hr, HHV)
33,866
16,395
12,023
17,168
Heat Output Rate
(BTU/hr, HHV)
23,765
10,411
8,894
11,968
Efficiency
(%, HHV)
70.2%
63.5%
74.0%
69.7%
Efficiency
(%, LHV)
75.0%
67.8%
79.0%
74.5%
CO Emission Rate
(g/min)
0.06
0.07
0.06
0.07
9 of 194
9 of 194
Sherwood Industries, Ltd
Models: Meridian-1, Meridian FPI, Meridian Cast Iron, GF55, GFI55
Report Number:0261PF026E
OMNI-Test Laboratories, Inc.
1.3 - Summary Tables
Table 3 Test Facility Conditions
Initial
Middle
Final
Room Temperature
(°F)
72
71
70
Barometric Pressure
(in Hg)
29.92
29.90
29.89
Air Velocity
(ft/min)
< 50
< 50
< 50
Induced Draft
(in H2O)
0
0
0
Table 4 Fuel Measurement Summary
Pretest
Burn Rate Segment
Integrated
Total
Maximum
Medium
Minimum
Time
(min)
60
61
120
180
361
Burn Rate
(dry kg/hr)
1.83
1.75
0.85
0.62
0.89
Consumed Fuel
(lbs)
4.3
4.2
4.0
4.4
12.6
Moisture Content
(dry basis %)
7.10
10 of 194
10 of 194
Sherwood Industries, Ltd
Models: Meridian-1, Meridian FPI, Meridian Cast Iron, GF55, GFI55
Report Number:0261PF026E
OMNI-Test Laboratories, Inc.
1.3 - Summary Tables
Table 5 Dilution Tunnel and Flue Gas Measurements
Burn Rate Segment
Integrated
Total
Maximum
Medium
Minimum
Flue Draft
(in H
2
O)
-0.057
-0.045
-0.038
-0.044
Tunnel Velocity
(ft/sec)
13.06
12.86
12.73
12.83
Tunnel Flow Rate
(dscf/min)
-
-
-
141.2
Tunnel Temperature
(°F)
111.7
92.5
87.8
93.4
Table 6 Heater Configuration
Pretest
Burn Rate Segment
Maximum
Medium
Minimum
Heat Output Setting
5 (max)
5 (max)
2
1 (min)
11 of 194
11 of 194
Sherwood Industries, Ltd
Models: Meridian-1, Meridian FPI, Meridian Cast Iron, GF55, GFI55
Report Number:0261PF026E
OMNI-Test Laboratories, Inc.
Section 2
Test Data
2.1 Test Data by Run
2.2 Sample Analysis & Tares
12 of 194
12 of 194
Sherwood Industries, Ltd
Models: Meridian-1, Meridian FPI, Meridian Cast Iron, GF55, GFI55
Report Number:0261PF026E
OMNI-Test Laboratories, Inc.
2.1 - Test Data by Run
Run 1 Notes & Results
13 of 194
13 of 194
OMNI-Test Laboratories, Inc.
Pellet Heater Preburn Data - ASTM E2779
PB Length:
106 min
Recording Interval: 1 min
344 71 0 3 0
Elapsed
Time (min)
Scale
Reading
Weight
Change
Stack (F)
Ambient
(F)
Draft
("H2O)
CO2 (%) CO (%)
0
52.1
-
70 70 0.03 0.20 0.00
1 1
52.1
0
70 70 0.03 0.19 0.00
2 2
52.1
0
70 70 0.03 0.19 0.00
3 3
52.1
0
71 70 0.03 0.18 0.00
4 4
52.1
0
71 70 0.03 0.14 0.00
5 5
52.1
0
71 70 0.03 0.12 0.00
6 6
52.1
0
71 70 0.03 0.10 0.00
7 7
52.1
0
71 70 0.02 0.10 0.00
8 8
52.1
0
71 70 0.03 0.09 0.00
9 9
52.1
0
71 70 0.03 0.09 0.00
10 10
52.1
0
71 70 0.03 0.09 0.00
11 11
52.1
0
72 70 0.03 0.09 0.00
12 12
52.1
0
72 70 0.03 0.09 0.00
13 13
52.1
0
73 70 0.03 0.09 0.00
14 14
52.1
0
76 70 0.03 0.09 0.00
15 15
52.0
-0.1
87 70 0.02 0.09 0.00
16 16
52.0
0
97 70 0.02 0.09 0.00
17 17
52.0
0
110 70 0.02 0.09 0.00
18 18
52.0
0
125 70 0.02 0.09 0.00
19 19
52.0
0
137 69 0.01 0.09 0.00
20 20
51.9
-0.1
152 70 0.01 0.09 0.00
21 21
51.9
0
168 69 0.01 0.09 0.00
22 22
51.8
-0.1
187 70 0.00 0.09 0.00
23 23
51.7
-0.1
206 70 0.00 0.09 0.00
24 24
51.6
-0.1
222 70 0.00 0.09 0.00
25 25
51.5
-0.1
236 70 -0.01 0.09 0.00
26 26
51.5
0
247 70 -0.01 0.09 0.00
27 27
51.4
-0.1
257 70 -0.01 0.09 0.00
28 28
51.3
-0.1
263 70 -0.01 0.09 0.00
29 29
52.5
1.2
269 70 -0.01 0.09 0.00
30 30
51.9
-0.6
273 70 -0.01 0.09 0.00
31 31
51.9
0
303 70 -0.03 0.09 0.00
32 32
51.8
-0.1
430 70 -0.03 0.09 0.00
33 33
51.9
0.1
427 70 -0.02 0.09 0.00
34 34
51.8
-0.1
410 70 -0.02 0.09 0.00
35 35
51.7
-0.1
424 70 -0.03 0.09 0.00
36 36
52.0
0.3
430 70 -0.03 0.09 0.00
37 37
51.6
-0.4
433 70 -0.03 0.09 0.00
38 38
51.6
0
403 70 -0.02 0.09 0.00
39 39
50.6
-1
422 70 -0.03 0.09 0.00
40 40
50.5
-0.1
429 70 -0.03 0.09 0.00
41 41
50.5
0
432 70 -0.03 0.09 0.00
42 42
50.4
-0.1
435 70 -0.03 0.09 0.00
43 43
50.3
-0.1
440 71 -0.03 0.09 0.00
44 44
50.2
-0.1
441 70 -0.03 0.09 0.00
45 45
50.2
0
440 70 -0.03 0.09 0.00
46 46
50.1
-0.1
436 70 -0.03 0.09 0.00
47 47
50.0
-0.1
434 71 -0.03 0.09 0.00
48 48
49.9
-0.1
437 70 -0.03 0.09 0.00
49 49
49.9
0
434 70 -0.03 0.09 0.00
50 50
49.8
-0.1
435 70 -0.03 6.79 0.03
51 51
49.8
0
434 70 -0.03 6.44 0.01
52 52
49.7
-0.1
438 71 -0.03 6.40 0.01
53 53
49.6
-0.1
436 71 -0.03 6.07 0.01
54 54
49.6
0
435 70 -0.03 6.53 0.00
55 55
49.5
-0.1
434 71 -0.03 6.37 0.01
56 56
49.4
-0.1
436 71 -0.03 2.43 0.00
57 57
49.4
0
436 70 -0.03 0.12 0.00
58 58
49.3
-0.1
431 70 -0.03 5.46 0.00
59 59
49.2
-0.1
437 71 -0.03 7.02 0.01
60 60
49.1
-0.1
437 71 -0.03 6.27 0.01
61 61
49.1
0
434 71 -0.03 5.95 0.02
62 62
49.0
-0.1
434 71 -0.03 6.27 0.01
Averages:
Sherwood
Meridian
2263
0268PS025E
1/11/2018
Manufacturer:
Model:
Tracking No.:
Project No.:
Test Date:
Control No. P-SFDK-0003, Effective Date 5/6/16 File - Run 1, Tab - Pre burn
14 of 194
14 of 194
OMNI-Test Laboratories, Inc.
63 63
48.9
-0.1
436 71 -0.03 6.61 0.01
64 64
48.9
0
433 71 -0.03 5.56 0.01
65 65
48.8
-0.1
433 71 -0.03 5.64 0.01
66 66
48.7
-0.1
436 71 -0.03 7.02 0.01
67 67
48.7
0
436 71 -0.03 6.81 0.02
68 68
48.6
-0.1
436 71 -0.03 6.48 0.01
69 69
48.5
-0.1
432 71 -0.03 5.67 0.01
70 70
48.5
0
430 71 -0.03 5.99 0.01
71 71
48.4
-0.1
434 71 -0.03 6.44 0.01
72 72
48.3
-0.1
432 71 -0.03 5.48 0.01
73 73
48.2
-0.1
433 71 -0.03 6.30 0.01
74 74
48.2
0
434 71 -0.03 6.48 0.02
75 75
48.1
-0.1
434 71 -0.03 6.42 0.01
76 76
48.1
0
429 71 -0.03 4.92 0.01
77 77
48.0
-0.1
430 71 -0.03 6.20 0.01
78 78
47.9
-0.1
434 71 -0.03 6.86 0.01
79 79
47.8
-0.1
433 72 -0.03 6.52 0.01
80 80
47.8
0
430 72 -0.03 5.64 0.01
81 81
47.7
-0.1
428 72 -0.03 5.42 0.01
82 82
47.6
-0.1
428 72 -0.03 6.32 0.01
83 83
47.6
0
429 72 -0.03 6.29 0.01
84 84
47.5
-0.1
429 72 0.00 4.65 0.00
85 85
47.4
-0.1
415 72 -0.01 0.07 0.00
86 86
47.4
0
417 72 -0.03 0.42 0.00
87 87
47.3
-0.1
428 72 -0.03 5.13 0.01
88 88
47.2
-0.1
434 72 -0.03 1.10 0.00
89 89
47.1
-0.1
435 72 -0.03 9.96 2.43
90 90
47.1
0
431 72 -0.03 1.13 0.11
91 91
47.0
-0.1
433 72 -0.03 1.04 0.09
92 92
46.9
-0.1
433 72 -0.03 6.00 0.01
93 93
46.9
0
432 72 -0.03 5.61 0.02
94 94
46.8
-0.1
433 72 -0.03 6.50 0.01
95 95
46.7
-0.1
432 72 -0.03 5.52 0.02
96 96
46.7
0
431 72 -0.03 5.88 0.01
97 97
46.6
-0.1
432 72 -0.03 6.15 0.01
98 98
46.5
-0.1
431 72 -0.03 6.06 0.01
99 99
46.4
-0.1
431 72 -0.03 6.21 0.01
100 100
46.4
0
432 72 -0.03 5.92 0.01
101 101
46.3
-0.1
433 72 -0.03 6.08 0.00
102 102
46.2
-0.1
436 72 -0.03 6.91 0.01
103 103
45.7
-0.5
436 72 -0.03 6.43 0.01
104 104
45.7
0
431 72 -0.03 0.08 0.00
105 105
45.9
0.2
427 72 -0.03 6.03 0.01
106 106
45.8
-0.1
428 72 -0.03 5.84 0.02
Control No. P-SFDK-0003, Effective Date 5/6/16 File - Run 1, Tab - Pre burn
15 of 194
15 of 194
OMNI-Test Laboratories, Inc.
Pellet Heater Test Data - ASTM E2779 / ASTM E2515
Run: 1
Sherwood High Burn End Time: 61 PM Control Modules: 335/336
Meridian Medium Burn End Time: 181 Dilution Tunnel MW(dry): 29.00 lb/lb-mole
Avg. Tunnel Velocity:
12.83 ft/sec.
2263 361 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Intial Tunnel Flow: 136.0 scfm
0268PS025E
Recording Interval:
1 min Dilution Tunnel H2O: 2.00 percent
Average Tunnel Flow:
141.2 scfm
Dilution Tunnel Static: -0.180 "H2O Post-Test Leak Check (1): 0.000 cfm @ -12 in. Hg
10:00 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ -12 in. Hg
Pitot Tube Cp: 0.99 Fuel Moisture: 6.62 Dry Basis %
Meter Box Y Factor: 0.981 (1) 0.984 (2) (Amb)
Barometric Pressure:
Begin Middle End
Average
Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center
29.92 29.9 29.89 29.90 "Hg
Initial dP 0.026 0.044 0.046 0.022 0.028 0.044 0.044 0.026 0.048
"H2O
OMNI Equipment Numbers:
Temp: 113 113 113 113 113 113 113 113 113
°F
V
strav
13.05
ft/sec
V
scent
15.13
ft/sec
F
p
0.863
Particulate Sampling Data
Elapsed
Time
(min)
Gas
Meter 1
(ft
3
)
Gas
Meter 2
(ft
3
)
Sample
Rate 1
(cfm)
Sample
Rate 2
(cfm)
Orifice
dH 1
("H
2
O)
Meter
Temp 1
(°F)
Meter
Vacuum 1
("Hg)
Orifice
dH 2
("H
2
O)
Meter
Temp 2
(°F)
Meter
Vacuum 2
("Hg)
Dilution
Tunnel (°F)
Dilution
Tunnel
Center
dP
sqrt dp vsi
Pro.
Rate 1
Pro.
Rate 2
Scale
Reading
Weight
Change
Stack Filter 1 Filter 2 Ambient
Draft
("H
2
O)
CO
2
(%)
CO (%)
0 0.000 0.000 0.75 75 1.52 0.45 75 0.9 113 0.048 0.219
13.06
12.6 428 71 71 72 -0.057 5.58 0.01
1 0.154 0.159 0.15 0.16 1.37 75 2.03 1.18 75 1.2 114 0.048 0.219
13.07
96 100 12.6 0 431 72 72 72 -0.057 6.75 0.01
2 0.320 0.325 0.17 0.17 1.38 75 2.04 1.18 75 1.2 114 0.048 0.219
13.07
104 104 12.5 -0.1 431 73 72 72 -0.057 6.41 0.01
3 0.486 0.492 0.17 0.17 1.38 75 2.03 1.17 75 1.2 114 0.048 0.219
13.07
104 105 12.4 -0.1 433 73 73 72 -0.058 6.25 0.01
4 0.652 0.658 0.17 0.17 1.38 75 2.04 1.17 75 1.2 114 0.048 0.219
13.07
104 104 12.3 -0.1 432 74 73 72 -0.057 5.94 0.01
5 0.817 0.824 0.17 0.17 1.37 75 2.04 1.17 75 1.2 114 0.048 0.219
13.07
103 104 12.3 0 431 74 73 72 -0.057 6.39 0.02
6 0.983 0.990 0.17 0.17 1.37 75 2.04 1.17 75 1.2 114 0.048 0.219
13.07
104 104 12.2 -0.1 433 74 73 72 -0.058 6.19 0.01
7 1.148 1.156 0.17 0.17 1.36 75 2.04 1.17 75 1.2 114 0.048 0.219
13.07
103 104 12.1 -0.1 435 74 74 72 -0.058 6.36 0.01
8 1.313 1.321 0.17 0.17 1.35 75 2.03 1.17 75 1.2 114 0.048 0.219
13.07
103 104 12.1 0 436 74 74 72 -0.058 6.36 0.02
9 1.477 1.487 0.16 0.17 1.35 76 2.04 1.17 75 1.2 114 0.048 0.219
13.07
102 104 12.0 -0.1 435 75 74 72 -0.057 6.69 0.01
10 1.642 1.653 0.17 0.17 1.34 76 2.04 1.16 75 1.2 114 0.048 0.219
13.07
103 104 11.9 -0.1 429 75 74 72 -0.057 5.38 0.01
11 1.806 1.818 0.16 0.17 1.35 76 2.04 1.16 76 1.2 114 0.048 0.219
13.07
102 103 11.9 0 433 75 74 72 -0.057 6.37 0.01
12 1.970 1.983 0.16 0.17 1.35 76 2.05 1.15 76 1.2 114 0.048 0.219
13.07
102 103 11.8 -0.1 432 75 74 72 -0.058 5.94 0.01
13 2.134 2.148 0.16 0.17 1.35 76 2.04 1.15 76 1.2 114 0.048 0.219
13.07
102 103 11.7 -0.1 432 75 75 72 -0.057 6.6 0.01
14 2.298 2.313 0.16 0.17 1.34 76 2.05 1.14 76 1.2 114 0.048 0.219
13.07
102 103 11.7 0 432 75 75 72 -0.058 6.79 0.01
15 2.462 2.477 0.16 0.16 1.34 76 2.04 1.15 76 1.2 114 0.048 0.219
13.07
102 103 11.6 -0.1 430 76 75 72 -0.057 5.63 0.01
16 2.626 2.641 0.16 0.16 1.34 77 2.04 1.14 76 1.2 114 0.048 0.219
13.07
102 103 11.5 -0.1 426 76 75 72 -0.057 5.66 0.01
17 2.791 2.805 0.17 0.16 1.34 77 2.05 1.14 77 1.2 113 0.048 0.219
13.06
103 103 11.5 0 425 76 75 72 -0.056 6.34 0.01
18 2.955 2.969 0.16 0.16 1.33 77 2.05 1.14 77 1.3 113 0.048 0.219
13.06
102 103 11.4 -0.1 427 76 75 72 -0.057 6.12 0.01
19 3.119 3.134 0.16 0.17 1.34 77 2.04 1.14 77 1.3 113 0.048 0.219
13.06
102 103 11.3 -0.1 425 76 75 72 -0.057 5.6 0.01
20 3.282 3.298 0.16 0.16 1.33 77 2.05 1.13 77 1.3 113 0.048 0.219
13.06
101 103 11.3 0 425 76 76 72 -0.057 6.43 0.01
21 3.446 3.461 0.16 0.16 1.33 77 2.06 1.13 77 1.3 113 0.048 0.219
13.06
102 102 11.2 -0.1 425 76 76 72 -0.057 6.23 0.01
22 3.609 3.625 0.16 0.16 1.33 78 2.06 1.13 77 1.3 113 0.048 0.219
13.06
101 103 11.1 -0.1 426 76 76 72 -0.057 6.06 0.01
23 3.773 3.789 0.16 0.16 1.33 78 2.05 1.13 78 1.3 113 0.048 0.219
13.06
102 102 11.1 0 422 77 76 72 -0.056 4.87 0.01
24 3.936 3.952 0.16 0.16 1.32 78 2.07 1.13 78 1.3 113 0.048 0.219
13.06
101 102 11.0 -0.1 424 77 76 72 -0.057 6.01 0.01
25 4.100 4.117 0.16 0.17 1.33 78 2.06 1.13 78 1.3 113 0.048 0.219
13.06
102 103 10.9 -0.1 427 77 76 72 -0.056 6.49 0.01
26 4.263 4.280 0.16 0.16 1.33 78 2.06 1.13 78 1.3 113 0.048 0.219
13.06
101 102 10.8 -0.1 424 77 76 72 -0.056 5.58 0.01
27 4.428 4.442 0.17 0.16 1.33 78 2.06 1.12 78 1.3 113 0.048 0.219
13.06
103 101 10.8 0 428 77 76 72 -0.057 7.64 0.03
28 4.591 4.605 0.16 0.16 1.33 79 2.07 1.12 78 1.3 113 0.048 0.219
13.06
101 102 10.7 -0.1 424 77 76 72 -0.056 5.63 0.01
29 4.754 4.768 0.16 0.16 1.32 79 2.08 1.12 78 1.3 113 0.048 0.219
13.06
101 102 10.6 -0.1 425 77 76 72 -0.057 6.75 0.01
30 4.917 4.932 0.16 0.16 1.32 79 2.08 1.12 79 1.3 113 0.048 0.219
13.06
101 102 10.6 0 426 77 76 72 -0.057 6.19 0.01
31 5.080 5.095 0.16 0.16 1.32 79 2.07 1.11 79 1.3 113 0.048 0.219
13.06
101 102 10.5 -0.1 425 77 76 72 -0.057 5.85 0.01
32 5.243 5.257 0.16 0.16 1.32 79 2.09 1.12 79 1.3 113 0.048 0.219
13.06
101 101 10.4 -0.1 423 77 76 72 -0.057 5.85 0.01
33 5.407 5.420 0.16 0.16 1.32 79 2.08 1.12 79 1.3 113 0.048 0.219
13.06
102 102 10.4 0 426 77 76 72 -0.057 6.45 0.01
34 5.570 5.583 0.16 0.16 1.32 79 2.09 1.11 79 1.3 113 0.048 0.219
13.06
101 102 10.3 -0.1 429 77 76 72 -0.058 6.93 0.01
35 5.734 5.746 0.16 0.16 1.31 80 2.08 1.11 79 1.3 113 0.048 0.219
13.06
102 102 10.2 -0.1 432 77 76 72 -0.058 6.24 0.01
36 5.898 5.908 0.16 0.16 1.32 80 2.09 1.10 79 1.3 113 0.048 0.219
13.06
102 101 10.2 0 426 77 77 72 -0.056 5.4 0.01
37 6.061 6.070 0.16 0.16 1.32 80 2.1 1.11 80 1.3 113 0.048 0.219
13.06
101 101 10.1 -0.1 425 77 76 72 -0.057 6.65 0.01
38 6.224 6.233 0.16 0.16 1.31 80 2.1 1.11 80 1.3 112 0.048 0.219
13.04
101 101 10.0 -0.1 420 77 77 72 -0.056 5.33 0.01
39 6.386 6.396 0.16 0.16 1.31 80 2.1 1.11 80 1.3 113 0.048 0.219
13.06
100 101 10.0 0 423 77 77 72 -0.057 5.79 0.01
Total Sampling Time:
Project No.:
Test Date:
11-Jan-18
Stack Gas Data
Velocity Traverse Data
Fuel Weight (lb)
Temperature Data (°F)
Manufacturer:
Model:
Tracking No.:
Beginning Clock Time:
Raw Data
Export to
Control No. P-SFDK-0003, Effective Date 5/6/16 File - Run 1, Tab - Data Entry
16 of 194
16 of 194
OMNI-Test Laboratories, Inc.
Pellet Heater Test Data - ASTM E2779 / ASTM E2515
Run: 1
Sherwood High Burn End Time: 61 PM Control Modules: 335/336
Meridian Medium Burn End Time: 181 Dilution Tunnel MW(dry): 29.00 lb/lb-mole
Avg. Tunnel Velocity:
12.83 ft/sec.
2263 361 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Intial Tunnel Flow: 136.0 scfm
0268PS025E
Recording Interval:
1 min Dilution Tunnel H2O: 2.00 percent
Average Tunnel Flow:
141.2 scfm
Dilution Tunnel Static: -0.180 "H2O Post-Test Leak Check (1): 0.000 cfm @ -12 in. Hg
10:00 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ -12 in. Hg
Pitot Tube Cp: 0.99 Fuel Moisture: 6.62 Dry Basis %
Meter Box Y Factor: 0.981 (1) 0.984 (2) (Amb)
Barometric Pressure:
Begin Middle End
Average
Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center
29.92 29.9 29.89 29.90 "Hg
Initial dP 0.026 0.044 0.046 0.022 0.028 0.044 0.044 0.026 0.048
"H2O
OMNI Equipment Numbers:
Temp: 113 113 113 113 113 113 113 113 113
°F
V
strav
13.05
ft/sec
V
scent
15.13
ft/sec
F
p
0.863
Particulate Sampling Data
Elapsed
Time
(min)
Gas
Meter 1
(ft
3
)
Gas
Meter 2
(ft
3
)
Sample
Rate 1
(cfm)
Sample
Rate 2
(cfm)
Orifice
dH 1
("H
2
O)
Meter
Temp 1
(°F)
Meter
Vacuum 1
("Hg)
Orifice
dH 2
("H
2
O)
Meter
Temp 2
(°F)
Meter
Vacuum 2
("Hg)
Dilution
Tunnel (°F)
Dilution
Tunnel
Center
dP
sqrt dp vsi
Pro.
Rate 1
Pro.
Rate 2
Scale
Reading
Weight
Change
Stack Filter 1 Filter 2 Ambient
Draft
("H
2
O)
CO
2
(%)
CO (%)
Total Sampling Time:
Project No.:
Test Date:
11-Jan-18
Stack Gas Data
Velocity Traverse Data
Fuel Weight (lb)
Temperature Data (°F)
Manufacturer:
Model:
Tracking No.:
Beginning Clock Time:
Raw Data
Export to
40 6.549 6.558 0.16 0.16 1.32 80 2.1 1.10 80 1.3 113 0.048 0.219
13.06
101 101 9.9 -0.1 426 77 77 72 -0.058 6.53 0.01
41 6.712 6.719 0.16 0.16 1.31 80 2.11 1.10 80 1.3 113 0.048 0.219
13.06
101 100 9.8 -0.1 430 77 77 72 -0.057 6.84 0.01
42 6.875 6.881 0.16 0.16 1.31 80 2.11 1.10 80 1.3 112 0.048 0.219
13.04
101 101 9.8 0 429 77 77 72 -0.057 6.19 0
43 7.039 7.044 0.16 0.16 1.31 80 2.11 1.10 80 1.3 112 0.048 0.219
13.04
101 101 9.7 -0.1 426 77 77 72 -0.057 5.2 0.01
44 7.202 7.205 0.16 0.16 1.31 81 2.12 1.10 80 1.3 113 0.048 0.219
13.06
101 100 9.6 -0.1 427 77 77 72 -0.057 6.32 0.01
45 7.364 7.367 0.16 0.16 1.30 81 2.11 1.10 80 1.3 113 0.048 0.219
13.06
100 101 9.6 0 427 77 77 72 -0.056 6.05 0.01
46 7.527 7.528 0.16 0.16 1.30 81 2.12 1.10 80 1.3 112 0.048 0.219
13.04
101 100 9.5 -0.1 428 77 77 72 -0.057 6.85 0.01
47 7.689 7.691 0.16 0.16 1.31 81 2.13 1.09 81 1.4 112 0.048 0.219
13.04
100 101 9.4 -0.1 428 77 77 72 -0.058 5.76 0.01
48 7.852 7.851 0.16 0.16 1.31 81 2.13 1.09 81 1.4 113 0.048 0.219
13.06
101 99 9.3 -0.1 429 77 77 72 -0.057 6.39 0.01
49 8.014 8.012 0.16 0.16 1.30 81 2.13 1.09 81 1.4 113 0.048 0.219
13.06
100 100 9.3 0 430 77 77 72 -0.058 6.58 0.01
50 8.178 8.173 0.16 0.16 1.30 81 2.14 1.09 81 1.4 112 0.048 0.219
13.04
101 100 9.2 -0.1 430 77 77 72 -0.058 5.88 0.01
51 8.340 8.335 0.16 0.16 1.29 81 2.15 1.09 81 1.4 112 0.048 0.219
13.04
100 100 9.1 -0.1 429 77 77 72 -0.057 5.6 0.01
52 8.502 8.495 0.16 0.16 1.29 81 2.15 1.08 81 1.4 113 0.048 0.219
13.06
100 99 9.1 0 433 77 77 72 -0.058 6.88 0.02
53 8.664 8.656 0.16 0.16 1.29 81 2.15 1.08 81 1.4 113 0.048 0.219
13.06
100 100 9.0 -0.1 434 77 77 72 -0.057 6.74 0.02
54 8.826 8.817 0.16 0.16 1.29 81 2.15 1.08 81 1.4 113 0.048 0.219
13.06
100 100 8.9 -0.1 427 77 77 72 -0.057 5.13 0.01
55 8.988 8.977 0.16 0.16 1.29 81 2.16 1.08 81 1.4 112 0.048 0.219
13.04
100 99 8.9 0 430 78 77 72 -0.058 6.58 0.01
56 9.151 9.137 0.16 0.16 1.29 82 2.17 1.07 81 1.4 113 0.048 0.219
13.06
101 99 8.8 -0.1 430 78 77 72 -0.057 6.1 0.01
57 9.312 9.297 0.16 0.16 1.28 82 2.18 1.07 81 1.4 113 0.048 0.219
13.06
99 99 8.7 -0.1 429 78 77 72 -0.057 6.32 0.01
58 9.473 9.456 0.16 0.16 1.28 82 2.18 1.07 81 1.4 113 0.048 0.219
13.06
99 99 8.6 -0.1 433 77 77 72 -0.058 7.04 0.03
59 9.634 9.616 0.16 0.16 1.29 82 2.19 1.07 81 1.4 113 0.048 0.219
13.06
99 99 8.6 0 429 77 77 72 -0.057 6 0.01
60 9.796 9.776 0.16 0.16 1.28 82 2.19 1.06 82 1.4 113 0.048 0.219
13.06
100 99 8.5 -0.1 428 78 77 72 -0.057 6.15 0.01
61 9.964 9.935 0.17 0.16 1.41 82 1.86 1.06 82 1.4 110 0.048 0.219
13.02
103 98 8.4 -0.1 423 77 77 72 -0.056 6.56 0.01
62 10.130 10.094 0.17 0.16 1.35 82 2.01 1.07 82 1.4 108 0.048 0.219
13.00
102 98 8.4 0 404 77 77 72 -0.053 3.19 0.01
63 10.296 10.254 0.17 0.16 1.35 82 2.01 1.06 82 1.4 107 0.048 0.219
12.99
102 99 8.4 0 393 77 77 72 -0.054 4 0.03
64 10.462 10.413 0.17 0.16 1.35 82 2.01 1.06 82 1.4 106 0.048 0.219
12.98
102 98 8.3 -0.1 387 77 76 72 -0.053 4.16 0.03
65 10.628 10.572 0.17 0.16 1.35 82 2.01 1.06 82 1.4 106 0.048 0.219
12.98
102 98 8.3 0 378 77 76 72 -0.052 3.19 0.09
66 10.794 10.732 0.17 0.16 1.35 82 2.02 1.06 82 1.4 105 0.048 0.219
12.96
102 98 8.3 0 376 77 76 72 -0.052 4.03 0.09
67 10.960 10.891 0.17 0.16 1.35 82 2.01 1.06 82 1.4 105 0.048 0.219
12.96
102 98 8.2 -0.1 373 77 76 72 -0.052 3.94 0.09
68 11.126 11.050 0.17 0.16 1.35 82 2.02 1.06 82 1.4 105 0.048 0.219
12.96
102 98 8.2 0 368 77 76 72 -0.052 3.3 0.14
69 11.292 11.210 0.17 0.16 1.35 82 2.02 1.06 82 1.4 104 0.048 0.219
12.95
102 98 8.2 0 362 77 76 71 -0.050 3.68 0.05
70 11.458 11.369 0.17 0.16 1.35 82 2.02 1.06 82 1.4 103 0.048 0.219
12.94
102 98 8.1 -0.1 355 77 76 72 -0.050 3.38 0.03
71 11.625 11.528 0.17 0.16 1.35 82 2.02 1.06 82 1.4 103 0.048 0.219
12.94
102 98 8.1 0 353 77 76 72 -0.051 3.67 0.01
72 11.791 11.688 0.17 0.16 1.35 82 2.02 1.06 82 1.4 102 0.048 0.219
12.93
101 98 8.1 0 347 77 76 71 -0.049 2.72 0.01
73 11.957 11.846 0.17 0.16 1.36 82 2.02 1.06 82 1.4 102 0.048 0.219
12.93
101 97 8.0 -0.1 342 77 76 72 -0.049 2.85 0.01
74 12.123 12.007 0.17 0.16 1.35 82 2.02 1.06 82 1.4 102 0.048 0.219
12.93
101 99 8.0 0 337 77 76 71 -0.047 2.96 0.01
75 12.289 12.165 0.17 0.16 1.35 82 2.02 1.06 82 1.4 101 0.048 0.219
12.92
101 97 8.0 0 330 77 76 72 -0.047 2.51 0.01
76 12.455 12.324 0.17 0.16 1.35 83 2.02 1.06 82 1.4 101 0.048 0.219
12.92
101 97 7.9 -0.1 333 77 76 71 -0.048 3.58 0.01
77 12.621 12.485 0.17 0.16 1.36 83 2.02 1.14 82 1.5 101 0.048 0.219
12.92
101 99 7.9 0 331 77 76 71 -0.047 2.79 0.01
78 12.787 12.650 0.17 0.17 1.35 83 2.02 1.14 82 1.5 101 0.048 0.219
12.92
101 101 7.8 -0.1 327 77 76 71 -0.047 2.78 0.01
79 12.954 12.816 0.17 0.17 1.35 83 2.02 1.14 82 1.5 100 0.048 0.219
12.91
102 102 7.8 0 325 76 76 71 -0.047 3.07 0.01
Control No. P-SFDK-0003, Effective Date 5/6/16 File - Run 1, Tab - Data Entry
17 of 194
17 of 194
OMNI-Test Laboratories, Inc.
Pellet Heater Test Data - ASTM E2779 / ASTM E2515
Run: 1
Sherwood High Burn End Time: 61 PM Control Modules: 335/336
Meridian Medium Burn End Time: 181 Dilution Tunnel MW(dry): 29.00 lb/lb-mole
Avg. Tunnel Velocity:
12.83 ft/sec.
2263 361 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Intial Tunnel Flow: 136.0 scfm
0268PS025E
Recording Interval:
1 min Dilution Tunnel H2O: 2.00 percent
Average Tunnel Flow:
141.2 scfm
Dilution Tunnel Static: -0.180 "H2O Post-Test Leak Check (1): 0.000 cfm @ -12 in. Hg
10:00 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ -12 in. Hg
Pitot Tube Cp: 0.99 Fuel Moisture: 6.62 Dry Basis %
Meter Box Y Factor: 0.981 (1) 0.984 (2) (Amb)
Barometric Pressure:
Begin Middle End
Average
Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center
29.92 29.9 29.89 29.90 "Hg
Initial dP 0.026 0.044 0.046 0.022 0.028 0.044 0.044 0.026 0.048
"H2O
OMNI Equipment Numbers:
Temp: 113 113 113 113 113 113 113 113 113
°F
V
strav
13.05
ft/sec
V
scent
15.13
ft/sec
F
p
0.863
Particulate Sampling Data
Elapsed
Time
(min)
Gas
Meter 1
(ft
3
)
Gas
Meter 2
(ft
3
)
Sample
Rate 1
(cfm)
Sample
Rate 2
(cfm)
Orifice
dH 1
("H
2
O)
Meter
Temp 1
(°F)
Meter
Vacuum 1
("Hg)
Orifice
dH 2
("H
2
O)
Meter
Temp 2
(°F)
Meter
Vacuum 2
("Hg)
Dilution
Tunnel (°F)
Dilution
Tunnel
Center
dP
sqrt dp vsi
Pro.
Rate 1
Pro.
Rate 2
Scale
Reading
Weight
Change
Stack Filter 1 Filter 2 Ambient
Draft
("H
2
O)
CO
2
(%)
CO (%)
Total Sampling Time:
Project No.:
Test Date:
11-Jan-18
Stack Gas Data
Velocity Traverse Data
Fuel Weight (lb)
Temperature Data (°F)
Manufacturer:
Model:
Tracking No.:
Beginning Clock Time:
Raw Data
Export to
80 13.120 12.981 0.17 0.16 1.35 83 2.02 1.14 82 1.5 99 0.048 0.219
12.89
101 101 7.8 0 319 76 76 71 -0.045 2.49 0.01
81 13.286 13.146 0.17 0.17 1.35 83 2.02 1.14 82 1.5 99 0.048 0.219
12.89
101 101 7.8 0 313 76 76 71 -0.044 2.64 0.01
82 13.452 13.311 0.17 0.16 1.35 83 2.02 1.14 82 1.5 98 0.048 0.219
12.88
101 101 7.7 -0.1 310 76 75 71 -0.045 2.76 0.01
83 13.618 13.477 0.17 0.17 1.35 83 2.02 1.14 82 1.5 98 0.048 0.219
12.88
101 101 7.7 0 309 76 75 71 -0.044 2.87 0
84 13.784 13.642 0.17 0.16 1.35 83 2.02 1.14 82 1.5 98 0.048 0.219
12.88
101 101 7.7 0 313 76 75 71 -0.047 3.69 0
85 13.950 13.807 0.17 0.17 1.35 83 2.02 1.14 82 1.5 98 0.048 0.219
12.88
101 101 7.6 -0.1 314 76 75 71 -0.045 3.52 0.01
86 14.116 13.973 0.17 0.17 1.35 83 2.02 1.13 82 1.5 98 0.048 0.219
12.88
101 101 7.6 0 310 76 75 72 -0.045 2.69 0.01
87 14.283 14.138 0.17 0.16 1.35 83 2.02 1.14 83 1.5 98 0.048 0.219
12.88
101 101 7.6 0 305 76 75 72 -0.044 2.58 0.01
88 14.449 14.303 0.17 0.17 1.35 83 2.02 1.14 82 1.5 97 0.048 0.219
12.87
101 101 7.5 -0.1 303 76 75 71 -0.044 2.73 0.01
89 14.615 14.467 0.17 0.16 1.35 83 2.02 1.14 83 1.5 97 0.048 0.219
12.87
101 100 7.5 0 302 76 75 71 -0.044 2.74 0.01
90 14.781 14.633 0.17 0.17 1.35 83 2.03 1.14 83 1.5 97 0.048 0.219
12.87
101 101 7.5 0 302 76 75 71 -0.044 3.36 0.01
91 14.947 14.797 0.17 0.16 1.35 83 2.03 1.14 83 1.5 97 0.048 0.219
12.87
101 100 7.4 -0.1 301 76 75 71 -0.044 2.94 0
92 15.113 14.963 0.17 0.17 1.35 83 2.03 1.14 83 1.5 97 0.048 0.219
12.87
101 101 7.4 0 301 76 75 71 -0.045 2.99 0.01
93 15.279 15.128 0.17 0.17 1.35 83 2.02 1.14 83 1.5 96 0.048 0.219
12.86
101 101 7.4 0 303 76 75 71 -0.045 3.62 0.01
94 15.446 15.293 0.17 0.16 1.35 83 2.02 1.14 83 1.5 96 0.048 0.219
12.86
101 101 7.3 -0.1 298 76 75 71 -0.043 2.55 0.01
95 15.612 15.459 0.17 0.17 1.35 83 2.03 1.14 83 1.5 96 0.048 0.219
12.86
101 101 7.3 0 298 76 75 71 -0.045 2.96 0.01
96 15.778 15.623 0.17 0.16 1.35 83 2.02 1.14 83 1.5 96 0.048 0.219
12.86
101 100 7.3 0 302 76 75 71 -0.044 3.38 0.01
97 15.944 15.788 0.17 0.17 1.35 83 2.03 1.13 83 1.5 97 0.048 0.219
12.87
101 101 7.2 -0.1 303 75 75 71 -0.046 3.43 0.01
98 16.110 15.953 0.17 0.16 1.35 83 2.03 1.14 83 1.5 97 0.048 0.219
12.87
101 101 7.2 0 306 75 75 71 -0.046 3.4 0.01
99 16.276 16.118 0.17 0.16 1.35 83 2.03 1.14 83 1.5 96 0.048 0.219
12.86
101 101 7.2 0 299 75 75 71 -0.043 2.46 0.01
100 16.443 16.283 0.17 0.17 1.35 83 2.02 1.14 83 1.5 96 0.048 0.219
12.86
101 101 7.1 -0.1 292 75 75 71 -0.043 2.15 0.02
101 16.609 16.448 0.17 0.16 1.35 83 2.03 1.14 83 1.5 96 0.048 0.219
12.86
101 101 7.1 0 296 75 75 71 -0.044 3.28 0.01
102 16.775 16.613 0.17 0.16 1.35 83 2.03 1.14 83 1.5 96 0.048 0.219
12.86
101 101 7.1 0 300 75 75 71 -0.044 3.41 0
103 16.941 16.779 0.17 0.17 1.35 83 2.03 1.13 83 1.5 96 0.048 0.219
12.86
101 101 7.0 -0.1 297 75 75 71 -0.044 3.06 0.01
104 17.107 16.944 0.17 0.16 1.35 83 2.03 1.14 83 1.5 96 0.048 0.219
12.86
101 101 7.0 0 300 75 74 71 -0.044 3.16 0.01
105 17.273 17.108 0.17 0.16 1.35 83 2.02 1.13 83 1.5 96 0.048 0.219
12.86
101 100 7.0 0 301 75 74 71 -0.044 3.37 0.01
106 17.440 17.273 0.17 0.16 1.35 83 2.03 1.13 83 1.5 96 0.048 0.219
12.86
101 101 6.9 -0.1 303 75 74 71 -0.045 3.48 0.01
107 17.606 17.438 0.17 0.16 1.35 83 2.02 1.14 83 1.5 95 0.048 0.219
12.85
101 100 6.9 0 299 75 74 71 -0.043 2.58 0.01
108 17.772 17.603 0.17 0.17 1.35 83 2.02 1.14 83 1.5 96 0.048 0.219
12.86
101 101 6.9 0 297 75 74 71 -0.044 2.83 0.01
109 17.938 17.768 0.17 0.16 1.35 83 2.03 1.13 83 1.5 95 0.048 0.219
12.85
101 100 6.8 -0.1 294 75 74 71 -0.044 2.6 0.01
110 18.104 17.933 0.17 0.16 1.35 83 2.03 1.14 83 1.5 95 0.048 0.219
12.85
101 100 6.8 0 293 75 74 71 -0.043 2.62 0.01
111 18.270 18.098 0.17 0.16 1.35 83 2.03 1.13 83 1.5 95 0.048 0.219
12.85
101 100 6.8 0 294 75 74 71 -0.044 2.73 0.01
112 18.436 18.263 0.17 0.17 1.35 83 2.03 1.13 82 1.5 95 0.048 0.219
12.85
101 101 6.7 -0.1 294 75 74 71 -0.043 2.77 0.01
113 18.602 18.428 0.17 0.16 1.35 83 2.03 1.13 82 1.5 95 0.048 0.219
12.85
101 101 6.7 0 289 75 74 71 -0.043 2.16 0.01
114 18.768 18.592 0.17 0.16 1.35 83 2.03 1.13 83 1.5 95 0.048 0.219
12.85
101 100 6.7 0 298 75 74 70 -0.046 3.95 0.01
115 18.934 18.757 0.17 0.17 1.35 83 2.03 1.13 82 1.5 95 0.048 0.219
12.85
101 101 6.6 -0.1 297 75 74 71 -0.044 2.81 0.01
116 19.100 18.922 0.17 0.16 1.35 83 2.04 1.14 82 1.5 95 0.048 0.219
12.85
101 101 6.6 0 293 75 74 70 -0.043 2.56 0.01
117 19.266 19.086 0.17 0.16 1.35 83 2.04 1.13 82 1.5 95 0.048 0.219
12.85
101 100 6.6 0 295 75 74 71 -0.045 3.19 0.01
118 19.432 19.251 0.17 0.17 1.35 83 2.04 1.14 82 1.5 95 0.048 0.219
12.85
101 101 6.5 -0.1 297 75 74 71 -0.044 3.01 0.01
119 19.599 19.417 0.17 0.17 1.35 83 2.04 1.13 82 1.5 95 0.048 0.219
12.85
101 101 6.5 0 298 74 74 71 -0.045 3.03 0.01
Control No. P-SFDK-0003, Effective Date 5/6/16 File - Run 1, Tab - Data Entry
18 of 194
18 of 194
OMNI-Test Laboratories, Inc.
Pellet Heater Test Data - ASTM E2779 / ASTM E2515
Run: 1
Sherwood High Burn End Time: 61 PM Control Modules: 335/336
Meridian Medium Burn End Time: 181 Dilution Tunnel MW(dry): 29.00 lb/lb-mole
Avg. Tunnel Velocity:
12.83 ft/sec.
2263 361 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Intial Tunnel Flow: 136.0 scfm
0268PS025E
Recording Interval:
1 min Dilution Tunnel H2O: 2.00 percent
Average Tunnel Flow:
141.2 scfm
Dilution Tunnel Static: -0.180 "H2O Post-Test Leak Check (1): 0.000 cfm @ -12 in. Hg
10:00 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ -12 in. Hg
Pitot Tube Cp: 0.99 Fuel Moisture: 6.62 Dry Basis %
Meter Box Y Factor: 0.981 (1) 0.984 (2) (Amb)
Barometric Pressure:
Begin Middle End
Average
Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center
29.92 29.9 29.89 29.90 "Hg
Initial dP 0.026 0.044 0.046 0.022 0.028 0.044 0.044 0.026 0.048
"H2O
OMNI Equipment Numbers:
Temp: 113 113 113 113 113 113 113 113 113
°F
V
strav
13.05
ft/sec
V
scent
15.13
ft/sec
F
p
0.863
Particulate Sampling Data
Elapsed
Time
(min)
Gas
Meter 1
(ft
3
)
Gas
Meter 2
(ft
3
)
Sample
Rate 1
(cfm)
Sample
Rate 2
(cfm)
Orifice
dH 1
("H
2
O)
Meter
Temp 1
(°F)
Meter
Vacuum 1
("Hg)
Orifice
dH 2
("H
2
O)
Meter
Temp 2
(°F)
Meter
Vacuum 2
("Hg)
Dilution
Tunnel (°F)
Dilution
Tunnel
Center
dP
sqrt dp vsi
Pro.
Rate 1
Pro.
Rate 2
Scale
Reading
Weight
Change
Stack Filter 1 Filter 2 Ambient
Draft
("H
2
O)
CO
2
(%)
CO (%)
Total Sampling Time:
Project No.:
Test Date:
11-Jan-18
Stack Gas Data
Velocity Traverse Data
Fuel Weight (lb)
Temperature Data (°F)
Manufacturer:
Model:
Tracking No.:
Beginning Clock Time:
Raw Data
Export to
120 19.765 19.581 0.17 0.16 1.35 83 2.03 1.13 82 1.5 95 0.048 0.219
12.85
101 100 6.5 0 299 74 74 70 -0.044 3.11 0.01
121 19.931 19.746 0.17 0.16 1.35 83 2.04 1.12 82 1.5 95 0.048 0.219
12.85
101 101 6.4 -0.1 293 74 74 70 -0.044 2.24 0.02
122 20.096 19.910 0.16 0.16 1.35 83 2.03 1.13 82 1.5 95 0.048 0.219
12.85
100 100 6.4 0 295 74 74 71 -0.044 3.05 0.01
123 20.262 20.075 0.17 0.16 1.35 83 2.04 1.13 82 1.5 95 0.048 0.219
12.85
101 101 6.4 0 294 74 74 70 -0.044 2.74 0.01
124 20.428 20.240 0.17 0.16 1.35 83 2.04 1.13 82 1.5 94 0.048 0.219
12.84
101 101 6.4 0 289 74 74 70 -0.043 2.43 0.01
125 20.594 20.404 0.17 0.16 1.35 83 2.04 1.13 82 1.5 94 0.048 0.219
12.84
101 100 6.3 -0.1 291 74 74 70 -0.045 3.02 0.01
126 20.760 20.569 0.17 0.16 1.35 83 2.04 1.13 82 1.5 94 0.048 0.219
12.84
101 101 6.3 0 292 74 74 70 -0.043 2.92 0.01
127 20.926 20.734 0.17 0.17 1.35 82 2.03 1.13 82 1.6 95 0.048 0.219
12.85
101 101 6.2 -0.1 295 74 74 70 -0.044 3.34 0.01
128 21.092 20.899 0.17 0.16 1.35 82 2.04 1.13 82 1.6 94 0.048 0.219
12.84
101 101 6.2 0 295 74 74 70 -0.043 2.97 0.01
129 21.258 21.063 0.17 0.16 1.35 82 2.04 1.13 82 1.5 94 0.048 0.219
12.84
101 100 6.2 0 294 74 74 70 -0.044 2.89 0.01
130 21.424 21.227 0.17 0.16 1.34 82 2.05 1.13 82 1.5 94 0.048 0.219
12.84
101 100 6.1 -0.1 298 74 74 70 -0.044 4.14 0.01
131 21.590 21.392 0.17 0.16 1.34 82 2.04 1.13 82 1.6 94 0.048 0.219
12.84
101 101 6.1 0 293 74 74 70 -0.043 2.62 0.01
132 21.756 21.556 0.17 0.16 1.35 82 2.05 1.13 82 1.6 94 0.048 0.219
12.84
101 100 6.1 0 292 74 74 70 -0.044 2.81 0.01
133 21.922 21.721 0.17 0.16 1.35 82 2.04 1.13 82 1.6 94 0.048 0.219
12.84
101 101 6.0 -0.1 298 74 74 70 -0.046 3.83 0.01
134 22.088 21.886 0.17 0.16 1.34 82 2.04 1.13 82 1.6 94 0.048 0.219
12.84
101 101 6.0 0 300 74 74 70 -0.046 3.27 0.01
135 22.254 22.050 0.17 0.16 1.35 82 2.05 1.12 82 1.6 95 0.048 0.219
12.85
101 100 6.0 0 301 74 74 70 -0.045 3.32 0.01
136 22.420 22.214 0.17 0.16 1.35 82 2.04 1.13 82 1.6 95 0.048 0.219
12.85
101 100 5.9 -0.1 305 74 73 70 -0.046 4.04 0
137 22.585 22.379 0.16 0.17 1.35 82 2.05 1.13 82 1.5 94 0.048 0.219
12.84
100 101 5.9 0 296 74 73 70 -0.044 1.92 0.02
138 22.751 22.543 0.17 0.16 1.35 82 2.05 1.13 82 1.6 95 0.048 0.219
12.85
101 100 5.9 0 298 74 73 70 -0.046 3.01 0.01
139 22.917 22.707 0.17 0.16 1.34 82 2.04 1.12 82 1.5 94 0.048 0.219
12.84
101 100 5.8 -0.1 296 74 73 70 -0.043 2.48 0.01
140 23.083 22.872 0.17 0.16 1.34 82 2.04 1.12 82 1.6 94 0.048 0.219
12.84
101 101 5.8 0 290 74 73 70 -0.044 2.14 0.02
141 23.249 23.037 0.17 0.16 1.34 82 2.04 1.13 82 1.5 94 0.048 0.219
12.84
101 101 5.8 0 289 74 73 70 -0.043 2.68 0.01
142 23.415 23.201 0.17 0.16 1.34 82 2.05 1.12 82 1.6 94 0.048 0.219
12.84
101 100 5.7 -0.1 288 74 73 70 -0.045 2.51 0.01
143 23.580 23.365 0.16 0.16 1.34 82 2.05 1.12 82 1.6 94 0.048 0.219
12.84
100 100 5.7 0 292 74 73 70 -0.045 2.84 0.01
144 23.746 23.529 0.17 0.16 1.34 82 2.05 1.12 82 1.6 94 0.048 0.219
12.84
101 100 5.7 0 299 74 73 70 -0.046 4.02 0.01
145 23.911 23.693 0.17 0.16 1.34 82 2.05 1.13 82 1.6 94 0.048 0.219
12.84
100 100 5.6 -0.1 302 74 73 70 -0.045 3.45 0.01
146 24.077 23.857 0.17 0.16 1.34 82 2.05 1.12 82 1.6 94 0.048 0.219
12.84
101 100 5.6 0 304 74 73 70 -0.046 3.43 0.01
147 24.243 24.022 0.17 0.16 1.34 82 2.05 1.12 82 1.6 94 0.048 0.219
12.84
101 101 5.6 0 301 74 73 70 -0.044 2.97 0.01
148 24.408 24.186 0.17 0.16 1.34 82 2.04 1.12 82 1.6 94 0.048 0.219
12.84
100 100 5.5 -0.1 294 74 73 70 -0.044 2.24 0.01
149 24.574 24.350 0.17 0.16 1.34 82 2.05 1.12 82 1.6 94 0.048 0.219
12.84
101 100 5.5 0 295 74 73 70 -0.045 3.19 0.01
150 24.739 24.514 0.16 0.16 1.35 82 2.05 1.12 82 1.6 94 0.048 0.219
12.84
100 100 5.5 0 296 74 73 70 -0.045 2.83 0.01
151 24.905 24.678 0.17 0.16 1.34 82 2.05 1.13 82 1.6 94 0.048 0.219
12.84
101 100 5.4 -0.1 292 74 73 70 -0.044 2.57 0.01
152 25.071 24.842 0.17 0.16 1.33 82 2.05 1.12 82 1.6 94 0.048 0.219
12.84
101 100 5.4 0 291 74 73 70 -0.045 2.51 0.01
153 25.236 25.006 0.16 0.16 1.33 82 2.05 1.12 82 1.6 94 0.048 0.219
12.84
100 100 5.4 0 290 74 73 70 -0.043 2.63 0.02
154 25.401 25.171 0.16 0.16 1.33 82 2.05 1.12 82 1.6 94 0.048 0.219
12.84
100 101 5.3 -0.1 290 74 73 70 -0.044 2.59 0.01
155 25.567 25.335 0.17 0.16 1.34 82 2.06 1.12 82 1.6 94 0.048 0.219
12.84
101 100 5.3 0 294 74 73 70 -0.044 3.41 0.01
156 25.733 25.498 0.17 0.16 1.35 82 2.08 1.12 82 1.6 94 0.048 0.219
12.84
101 99 5.3 0 294 74 73 70 -0.044 2.9 0.01
157 25.899 25.664 0.17 0.17 1.35 82 2.07 1.15 82 1.6 94 0.048 0.219
12.84
101 101 5.2 -0.1 296 74 73 70 -0.044 3.22 0.01
158 26.065 25.830 0.17 0.17 1.35 82 2.07 1.14 82 1.6 94 0.048 0.219
12.84
101 101 5.2 0 296 74 73 70 -0.044 2.74 0.02
159 26.231 25.995 0.17 0.17 1.35 82 2.07 1.15 82 1.6 94 0.048 0.219
12.84
101 101 5.2 0 294 74 73 70 -0.045 2.7 0.01
Control No. P-SFDK-0003, Effective Date 5/6/16 File - Run 1, Tab - Data Entry
19 of 194
19 of 194
OMNI-Test Laboratories, Inc.
Pellet Heater Test Data - ASTM E2779 / ASTM E2515
Run: 1
Sherwood High Burn End Time: 61 PM Control Modules: 335/336
Meridian Medium Burn End Time: 181 Dilution Tunnel MW(dry): 29.00 lb/lb-mole
Avg. Tunnel Velocity:
12.83 ft/sec.
2263 361 min Dilution Tunnel MW(wet): 28.78 lb/lb-mole Intial Tunnel Flow: 136.0 scfm
0268PS025E
Recording Interval:
1 min Dilution Tunnel H2O: 2.00 percent
Average Tunnel Flow:
141.2 scfm
Dilution Tunnel Static: -0.180 "H2O Post-Test Leak Check (1): 0.000 cfm @ -12 in. Hg
10:00 Background Sample Volume: cubic feet Tunnel Area: 0.19635 ft2 Post-Test Leak Check (2): 0.000 cfm @ -12 in. Hg
Pitot Tube Cp: 0.99 Fuel Moisture: 6.62 Dry Basis %
Meter Box Y Factor: 0.981 (1) 0.984 (2) (Amb)
Barometric Pressure:
Begin Middle End
Average
Pt.1 Pt.2 Pt.3 Pt.4 Pt.5 Pt.6 Pt.7 Pt.8 Center
29.92 29.9 29.89 29.90 "Hg
Initial dP 0.026 0.044 0.046 0.022 0.028 0.044 0.044 0.026 0.048
"H2O
OMNI Equipment Numbers:
Temp: 113 113 113 113 113 113 113 113 113
°F
V
strav
13.05
ft/sec
V
scent
15.13
ft/sec
F
p
0.863
Particulate Sampling Data
Elapsed
Time
(min)
Gas
Meter 1
(ft
3
)
Gas
Meter 2
(ft
3
)
Sample
Rate 1
(cfm)
Sample
Rate 2
(cfm)
Orifice
dH 1
("H
2
O)
Meter
Temp 1
(°F)
Meter
Vacuum 1
("Hg)
Orifice
dH 2
("H
2
O)
Meter
Temp 2
(°F)
Meter
Vacuum 2
("Hg)
Dilution
Tunnel (°F)
Dilution
Tunnel
Center
dP
sqrt dp vsi
Pro.
Rate 1
Pro.
Rate 2
Scale
Reading
Weight
Change
Stack Filter 1 Filter 2 Ambient
Draft
("H
2
O)
CO
2
(%)
CO (%)
Total Sampling Time:
Project No.:
Test Date:
11-Jan-18
Stack Gas Data
Velocity Traverse Data
Fuel Weight (lb)
Temperature Data (°F)
Manufacturer:
Model:
Tracking No.:
Beginning Clock Time:
Raw Data
Export to
160 26.397 26.162 0.17 0.17 1.35 82 2.08 1.15 82 1.6 94 0.048 0.219
12.84
101 102 5.1 -0.1 299 74 73 70 -0.045 3.82 0.01
161 26.564 26.327 0.17 0.17 1.34 82 2.08 1.15 82 1.6 94 0.048 0.219
12.84
101 101 5.1 0 296 74 73 70 -0.045 2.6 0.02
162 26.730 26.493 0.17 0.17 1.34 82 2.08 1.14 82 1.6 94 0.048 0.219
12.84
101 101 5.1 0 299 73 73 70 -0.044 3.1 0.01
163 26.896 26.659 0.17 0.17 1.34 82 2.07 1.14 82 1.6 94 0.048 0.219
12.84
101 101 5.0 -0.1 298 74 73 70 -0.044 2.63 0.01
164 27.062 26.825 0.17 0.17 1.35 82 2.08 1.14 82 1.6 94 0.048 0.219
12.84
101 101 5.0 0 296 74 73 70 -0.045 2.75 0.01
165 27.228 26.990 0.17 0.16 1.35 82 2.08 1.14 82 1.6 94 0.048 0.219
12.84
101 101 5.0 0 298 74 73 70 -0.044 2.93 0.01
166 27.394 27.156 0.17 0.17 1.34 82 2.08 1.14 82 1.6 94 0.048 0.219
12.84
101 101 4.9 -0.1 299 74 73 70 -0.045 3.15 0.01
167 27.560 27.321 0.17 0.17 1.34 82 2.08 1.14 82 1.6 94 0.048 0.219
12.84
101 101 4.9 0 297 73 73 70 -0.045 2.62 0.01
168 27.726 27.486 0.17 0.16 1.34 82 2.09 1.14 82 1.6 95 0.048 0.219
12.85
101 101 4.8 -0.1 304 74 73 70 -0.046 4.35 0.01
169 27.892 27.651 0.17 0.16 1.34 82 2.08 1.14 82 1.6 95 0.048 0.219
12.85
101 101 4.8 0 301 74 73 70 -0.045 2.4 0.02
170 28.058 27.817 0.17 0.17 1.34 82 2.08 1.14 82 1.6 95 0.048 0.219
12.85
101 101 4.8 0 301 74 73 70 -0.045 3.12 0.01
171 28.224 27.982 0.17 0.16 1.35 82 2.08 1.14 82 1.6 95 0.048 0.219
12.85
101 101 4.8 0 300 74 73 70 -0.044 3.14 0.01
172 28.390 28.148 0.17 0.17 1.35 82 2.09 1.14 82 1.6 95 0.048 0.219
12.85
101 101 4.7 -0.1 297 74 73 70 -0.045 2.73 0.01
173 28.556 28.314 0.17 0.17 1.35 82 2.09 1.14 82 1.6 95 0.048 0.219
12.85
101 101 4.7 0 300 74 73 70 -0.045 3.43 0
174 28.721 28.479 0.16 0.16 1.35 82 2.08 1.14 82 1.6 95 0.048 0.219
12.85
100 101 4.7 0 296 74 73 70 -0.044 2.47 0.01
175 28.887 28.644 0.17 0.16 1.34 82 2.08 1.14 82 1.6 95 0.048 0.219
12.85
101 101 4.6 -0.1 299 74 73 70 -0.046 3.26 0.01
176 29.053 28.808 0.17 0.16 1.35 82 2.08 1.14 82 1.6 95 0.048 0.219
12.85
101 100 4.6 0 301 74 73 70 -0.044 3.01 0.01
177 29.219 28.974 0.17 0.17 1.34 82 2.08 1.14 82 1.6 94 0.048 0.219
12.84
101 101 4.6 0 291 74 73 70 -0.044 1.88 0.03
178 29.385 29.139 0.17 0.16 1.34 82 2.09 1.14 82 1.6 95 0.048 0.219
12.85
101 101 4.5 -0.1 293 74 73 70 -0.044 2.92 0.01
179 29.550 29.304 0.16 0.16 1.34 82 2.09 1.14 81 1.6 95 0.048 0.219
12.85
100 101 4.5 0 297 74 73 70 -0.045 3.23 0.01
180 29.716 29.469 0.17 0.17 1.34 82 2.08 1.14 81 1.6 95 0.048 0.219
12.85
101 101 4.5 0 298 74 73 70 -0.045 3.03 0.01
181 29.882 29.634 0.17 0.16 1.34 82 2.09 1.14 81 1.6 95 0.048 0.219
12.85
101 101 4.4 -0.1 300 74 73 70 -0.045 3.08 0.01
182 30.047 29.800 0.16 0.17 1.35 82 2.09 1.13 81 1.6 90 0.048 0.219
12.79
100 101 4.4 0 290 74 73 70 -0.044 3.5 0.01
183 30.213 29.964 0.17 0.16 1.35 82 2.09 1.13 81 1.6 87 0.048 0.219
12.76
100 99 4.4 0 273 74 73 70 -0.042 3.18 0.01
184 30.378 30.129 0.16 0.17 1.34 82 2.09 1.13 81 1.6 86 0.048 0.219
12.74
99 100 4.3 -0.1 265 73 73 70 -0.042 4.42 0.01
185 30.544 30.294 0.17 0.16 1.34 82 2.1 1.13 81 1.6 85 0.048 0.219
12.73
100 100 4.3 0 257 73 73 70 -0.040 3.7 0.01
186 30.710 30.459 0.17 0.16 1.34 82 2.09 1.13 81 1.6 84 0.048 0.219
12.72
100 100 4.3 0 249 73 73 70 -0.039 2.92 0.01
187 30.875 30.624 0.16 0.16 1.34 82 2.09 1.13 82 1.6 83 0.048 0.219
12.71
99 100 4.3 0 243 73 73 70 -0.039 3.04 0.01
188 31.041 30.789 0.17 0.17 1.34 82 2.09 1.13 81 1.6 83 0.048 0.219
12.71
100 100 4.2 -0.1 241 73 73 70 -0.039 4.04 0.01
189 31.206 30.954 0.16 0.16 1.34 82 2.1 1.14 81 1.6 83 0.048 0.219
12.71
99 100 4.2 0 238 73 73 70 -0.039 3.03 0.02
190 31.372 31.119 0.17 0.16 1.34 82 2.1 1.12 82 1.6 83 0.048 0.219
12.71
100 100 4.2 0 237 73 73 70 -0.038 3.61 0.01
191 31.537 31.284 0.16 0.16 1.34 82 2.1 1.13 82 1.6 82 0.048 0.219
12.70
99 99 4.2 0 238 73 73 70 -0.039 3.99 0.01
192 31.702 31.448 0.17 0.16 1.34 82 2.1 1.12 82 1.6 82 0.048 0.219
12.70
99 99 4.1 -0.1 237 73 73 70 -0.038 3.53 0.01
193 31.868 31.612 0.17 0.16 1.34 82 2.1 1.13 82 1.6 82 0.048 0.219
12.70
100 99 4.1 0 235 73 72 70 -0.038 3.15 0.01
194 32.033 31.777 0.17 0.17 1.34 82 2.1 1.13 82 1.6 83 0.048 0.219
12.71
99 100 4.1 0 234 73 72 70 -0.038 2.79 0.01
195 32.199 31.941 0.17 0.16 1.33 82 2.11 1.12 81 1.6 83 0.048 0.219
12.71
100 99 4.1 0 237 73 72 70 -0.038 4.02 0
196 32.364 32.106 0.16 0.17 1.33 82 2.11 1.12 82 1.6 83 0.048 0.219
12.71
99 100 4.0 -0.1 238 73 72 70 -0.038 3.59 0.01
197 32.529 32.271 0.17 0.16 1.34 82 2.12 1.12 82 1.6 84 0.048 0.219
12.72
99 100 4.0 0 238 73 72 70 -0.038 3.3 0.01
198 32.695 32.435 0.17 0.16 1.33 82 2.11 1.13 81 1.6 84 0.048 0.219
12.72
100 99 4.0 0 238 73 72 70 -0.038 3.5 0
199 32.859 32.599 0.16 0.16 1.33 82 2.11 1.12 81 1.6 85 0.048 0.219
12.73
99 99 4.0 0 240 73 72 70 -0.038 3.91 0.01
Control No. P-SFDK-0003, Effective Date 5/6/16 File - Run 1, Tab - Data Entry
20 of 194
20 of 194
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159

Sherwood meridian series User manual

Category
Stoves
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI