Safety
Never carry out measurements on non-insulated wires with a
potential of over 600 V in relation to earth.
Never open the case on the ammeter clip before having first disconnected it from
any source of electricity.
Do not use the 711P.500 clip outside.
Technical specifications
Size : 250 x 97 x 44 mm
Weight : 440 g
1 battery : 9 volts
(type: 6LR61 - 6LF22 - NEDA 1604)
Endurance :120 hours with alkaline battery
: 60 hours with saline battery
Indication that battery is running out
: green indicator light flashes
Capacity : 600 A DC or 400 A AC
(600 A en crête)
Output signal : 1 mV, DC or AC for 1 A, DC or AC
Measuring equipment impedance :
1 M
and
100 pF
Operating temperature range : -10° to +65°C
Storage temperature range : -40° to +80°C
Relative humidity in use : < 20 to 75% RH
Relative humidity in storage : < 80% RH
(up to 40°C)
Double insulation : Installation category III
Degree of pollution : 2
(per standard IEC 1010-1)
Seal : IP40
(per IEC 529)
Electrical safety :
(per standard IEC 1010-2-032)
Degree of casing protection :
(per standard IEC 529)
Radiated field : 3 V/m
(per IEC 801-3)
Free fall : 1 m
(per IEC 1010)
Vibrations : 0.75 mm
(per IEC 68.2.6)
Impacts : 0.5 joules
(per IEC 68.2.27)
Electric shocks : 3 kV
(per IEC 801.5)
Electrostatic discharge : 4 kV class 2
(per IEC 1000-4-2)
Rapid transients : 1 kV level 2, aptitude criteria B
(IEC 1000-4-4)
Maximum dimensions : 30mm-Ø cable or 2 of 24mm-Ø cables
: Bar cross-section 50 x 10 mm
Comes with a 1.5 m cord with two 4 mm-diameter male plugs on the end, a 9 V
battery not fitted, an instruction manual and a guarantee leaflet.
Gap for wire
Jaw
Anti-slip protector
Opening lever On/off switch
Direction of direct current
Sealed 1.5 m cord
Button to reset when
under direct current
Green «on» indicator
light
6
Connection
• Insert the red safety plug into the «
+
» terminal on the 711 multimeter.
• Insert the black safety plug into the «COM» terminal on the multimeter.
• Turn the selector on the multimeter to «V», the voltmeter position.
• Slide the button on the 711P.500 clip to «1 m V/A» ; if the green indicator
light marked ON is constant the battery is fine, if it flashes the battery is too low.
Setting
• Alternating current
~
: direct readover
(1 mV = 1 A)
.
• Direct current: press the /
~
button on the 711 until the « » symbol is
displayed.
• Use the «sunken» grey button on the 711P.500 clip to set to 000.0 mV on
the multimeter display.
Use
Place the ammeter clip jaws around the wire to be checked, the arrow on the
jaws showing the standard current direction.
Alternating current «
~
»: when the current passes through the wire, read the
direct value on the 711 multimeter display. To check an alternating current, the
«
~
» sign has to be displayed on the screen with the « /
~
» button.
Direct current « »: when the current passes through the wire, follow the
standard current direction. To check a direct current, the « » sign has to be
displayed on the screen with the « /
~
» button.
Read the actual current on the multimeter screen passing through the wire being
tested
(1mV=1A)
. When the «-» sign appears in front of the value displayed, the
direction of the current passing through the test wire does not match the indicator
arrow on the clip, so reverse it. With the 711 multimeter, you can store the
minimum or maximum current value on the display with the MIN/MAX button.
---
---
---
---
---
---
7
Measuring alternating current
For example : Current consumption of electrical appliances (industrial motors,
radiators, dishwashers etc.)
Measuring direct current
For example : Alternator output, current consumption of a starter, pre-heating
plugs, accessories etc.
Changing the battery
Slide the button on the ammeter clip to OFF. On the back of the unit, slacken
the captive screw, take the lid off and replace the 9 volt battery
(6LR61 or 6LF22 or
NEDA 1604)
. Put the lid back on before using your clip again.
12 volt
20
UNITED KINGDOM
EIRE
FACOM Tools Ltd
Bridge Wharf - Bridge Road
CHERTSEY - SURREY KT16 8LJ
UNITED KINGDOM
: (01932) 566099
Fax : (01932) 562653
DEUTSCHLAND
FACOM GmbH
Postfach 13 22 06
42049 Wuppertal
Otto-Wels-Straße 9
42111 Wuppertal
DEUTSCHLAND
: (0202) 704051
Fax : (0202) 706958
NEDERLAND
FACOM Gereedschappen BV
Kamerlingh Onnesweg 2
Postbus 134
4130 EC Vianen
NEDERLAND
: (0347) 372334
Fax : (0347) 376020
ESPAÑA
PORTUGAL
FACOM Herramientas, S.L
Poligono industrial de Vallecas
C/.Luis 1°, s/n-Nave 95 -
2°Planta
28031 Madrid
ESPAÑA
: (91) 778 21 13
Fax : (91) 778 27 53
ITALIA
U.A. FACOM Italia
Via Ronchetti 3
21041 Albizzate (VA)
ITALIA
: (0331) 985811
Fax : (0331) 985930
BELGIQUE/BELGIE
S.A. FACOM N.V
Weihoek 4 1930 Zaventem
BELGIQUE
: (02) 720 92 07
Fax : (02) 721 24 11
SUISSE/SCHWEIZ
AUSTRIA
FACOM S.A./AG
12 route Henri-Stéphan
1762 Givisiez/Fribourg
SUISSE
: (4126) 466 42 42
Fax : (4126) 466 38 54
UNITED STATES
FACOM TOOLS Inc.
3535 West 47th Street
Chicago Illinois 60632
U.S.A.
: (773) 523 1307
Fax : (773) 523 2103
SINGAPORE
FAR EAST
FACOM Tools FAR EAST Pte Ltd
15 Scotts Road
Thong Teck Building # 08-01-02
Singapore 228218
SINGAPORE
: (65) 732 0552
Fax : (65) 732 5609
FRANCE
Société FACOM
6-8 rue Gustave Eiffel BP.99
91423 Morangis cedex
FRANCE
: 01 64 54 45 45
Fax : 01 69 09 60 93
/