CAUTION: Before using this
product, read this manual and
follow all Safety Rules and
Operating Instructions°
HOURS: Mon. - Fri, 8 a.m. to 5 p_m, (CST)
SEARS, ROEBUCK and CO., Hoffman Estates, IL 60179 U.S.Ao
Part No 996£4 Draft I (3113197)
SAFETY RULES 2-3
ASSEMBLY 4.
OPERATION 5-8
MAINTENANCE 9-t0
SERVICE AND ADJUSTtvtENTS 11
STORAGE 11
TROUBLESHOOTING 12
REPLACEMENT PARTS 13-19
HOW TO ORDER PARTS ...... BACK PAGE
"" Cr_AF __MAN GENERATOR
L_MtTED ONE Y=AR WARRANTY ON .... '= .... '
For one year from the date of purchase, when tMs Craftsman Generator is maintained and operated according
to the instructions in the owner's manual, Sears will repair, free of charge, any defect in materiai and workman-
ship
if this generator is used for commercial purposes, this walranty applies lor only 90 days from the date of pur.-
chase If [his Generator is used for rental purposes, this warranty applies for only 30 days after date of pur.-
chase
This warranty does not cover:
° Expendable items such as spark plugs and air filters, whictqbecome worn during normal use
o Repairs necessary because of operator abuse or negligence, including failure to maintain the equipment accord..
ing to the instructions contained in the owner's manual
WARRANTY SERVICE IS AVAILABLE BY RETURNING THE GENERATOR TO THE NEAREST SEARS
STORE OR OTHER CRAFTSMAN OUTLET IN THE UNITED STATES.
This warranty gives you specific legal rights and you may also have other rights, which vary from state to
state.
SEARS, ROEBUCK AND CO,, D1817 WA, Hoffman Estates, 1L 60I79
CAUTION: Always disconnect spark plug wire and place the wire where it cannot contact the spai'k
plug. To prevent accidental starting when setting up, transport#_g, adjustinc_ or makin_ rep_irs to
your Generator..
DANGER: This generato[ is designed for outdoor use only. Do not use this genel'ator inside a_y
building m' enclosure including the generatm" compartment of a recreational vehicle (RV). Fire of an
eY,plosion may result. No user' performed modifications, includi_'_g ve_'_tincjof exhaR._standi'ot' cook
ing ventilation, will eliminate the danger. Also, allow at least b._ofeet of clearance on all sides of
the generator even while operating the unit outdoors.
CAUTION: Before using this p_oduct,
read this manual and follow all Safety
Rules and Operating Instructions°
o The generator produces dangerously high voltage that can
cause extremely [_azardouselectrical shock Avoid contact
with bare wires, terminals, etc, Never permit any unquali-
fied personto operate or service the generator
. Never handle any kind of electrical cord or device while
standing in water, while barefoot or while hands or feet are
wet. Dangerous electrical shock wilt result
The National Electric Code requires the frame and external
electrically conductive parts of generator be properly con-
nected to an approved earth ground Local electricaicodes
may also require proper grounding of the generator
Consult with a local electrician for grounding requirements
in your area.
Use a ground fault circuit interrupter it1any damp or highly
conductive area (such as metal decking or steel work)
Do riot _.tseany worn, bare, frayed or otherwise damaged
electrical cord setswith the generator. Using any defective
cord set may result in electrical shock or damage to equip-
ment and!or property.
Operate generator only on level surfaces and where,it will
not be exposed to excessive moisture, dirt, dust or co_ro-
siva vapors,
GasolineishighlyFLAMMABLEanditsvaporsare
EXPLOSIVEDonotpermitsmoking,openflames,
sparksorheatinthevicinitywhilehandlinggasoline
AvoidspillinggasolineonahotengineComplywith
alttawsregulatingstorageandhandlingofgasoline
, DonotoverfillthefueitankNways allow roomfor fuel
expansion li tank is overfilled, iuet can overflow onto
a hot engine and cause FIRE or an E>(PLOSION
, Never store generator with fuet in tank where gasoline
vapors might reach an open ltame or spark or pilot
tigh! (as on a furnace, water healer ol clothes dryer)
FIRE or an EXPLOSION might result
, Generator exhaust gases contain DEADLY carbon
monoxide gas- This dangerous gas, ifbreathed in suf-
ficient concentrations, can cause unconsciousness or
even death Operate this equipment only in the open
air where adequate ventilation is available
,, The engine-generator requires an adequate flow ol
cooling air for its continued proper operation Never
operate the unit inside any room or enclosure where
the free flow of cooling air intoand out ofthe unit might
be obstructed Without sufficienl cooling air flow, the
unil quickly overheats, damaging the generator or
nearby property,
,_ Allowat least 2 feet of clearanceon allsides d genera-
tor, even while operating unit outdoors, or you could
damagethe unit.
o, Never start, or stop, the engine-generator with electri-
cal loads connected to receptacles with the connected
devices turned ON Startthe engine and let it stabilize
before connecting electrical loads Disconnecl all
electrical loads before shutting down the generator
,, Do not insert any object through cooling slots of the
engineogenerator You coulddamage the unil or injure
yourself
Never operate generalor {a) in rain, (b) in any
enclosed compartment; (c) ii engine speed changes;
(d) if connected electrical devices overheat; (e) if elec-
trical output is lost;(f) if engine or generator sparks; (g}
if flame or smoke is observed while unit is running; (h)
if unit vibrates excessively
Note: In the State of Cafifornia a spark arrestor is
required by law (Section 4442 of the California
Public Resources Code) Other states may have
similar taws Federal taws apply on federal lands
Note: If you equip the engine of your Generator with
a spark arrestor muffler, the spark arrestor must be
maintained in effective working order by the
owner/operator
You can order a spark arrestor (part # 398067)
through your Sears Service Center
LOOK FOR THIS SYtVtBOL TO POINT OUT IMPORTANT SAFETY PRECAUTIONS, ]
tT MEANS "ATFENTION!!! BECOME ALERT!!! YOUR SAFETY IS INVOLVED."
t
CARTON CON'TENTS 120-VOLT CORD SETS
Tt_efollowing parts are shipped loose with your
Generator:
" Main Unit -- Generator with wheels and guide handle
o Wire Form
o Battery Charge Cabtes
Become familiar with each piece before assembling the
Generator Check all contents against the illustration on
Page 6 If any parts are missing or damaged, call the
Gene_atoI Helpline at t-800-222-3136.
TO REMOVE GENERATOR FROM
CARTON
Use only high qualibi, weIFinsutated, extension cords with
the generator's 120-volt type electrical receptacles
..,y ,.
120--volt Receptacles.
o Remove loose parts included with Generator
. Slice two corners at guide handle end of carton from
lop to bottom so the panel can be folded down flat,
then remove all packing material
. Raise guide handle and secure in place
Loosen knobs
to raise handle,,
ill
fi'//
_ Tighten knobs
"t when handle is
straight.
J
i-._
.. Remove the unit by rolling it out the opening in the
carton, then check carton for additional loose parts
HOW TO SET LIP YOUR GENERATOR
For the most part, your Craftsman Generator has been
assembled at the factory You must, however, attach the
wire form
o Insert the wire support
Check the ratings of all extension co_dsbefore you use
them Extension cord sets used should be rated 125 volts
at 15 ac amps or greater for most electrical devices
Some devices, however', may not require this type of
exfension cord Check the owner's manuals of those
devices for the manufacturer's recornmendations
Keep extension cords as short as possible, preferably
less than 15 feet long to prevent voltage d{op and possi-
ble overheating of wires
GROUNDING THE GENERATOR.
The National Electrical Code requires that the frame and
external electrically conductive parts of this generator be
properly connected to an approved earth ground Local
electrical codes may also require proper grounding of the
unit. Foethat purpose, a grounding wing nut is provided
on top of base plate
Generally, connecting a No !2 AWG (American Wire
Gauge) stranded copper wire to the grounding lug and to
an earth-driven copper or brass grounding rod (electrode)
provides adequate p_otection against electrical shock
However, local codes may vary widely. Consult with a
local electrician for grounding requirements in your area
Propel grounding of generator wilt help prevent electrical
shock in the event of a ground fault condition in the gen-
erator or in connected electrical devices Proper ground-
ing also helps dissipate static electricity, which often
builds up in ungrounded devices.
KNOW YOUR GENERATOR
t I Bead the ot_her s rnanuat and safer3, rut_s before op_ratin_ your ggnerator Compare the illustrations with your
Generator to familiarize yourself with the locations d various controls and adjustments Save this manual for future ref-
erence
Guide Handte
Form
H.P, Engine
120 Volts Rece
Drain P_ug
Volts DC Receptacle
15-AMP AC Circuit Breaker
t20 VOLTS RECEPTACLES _ May be used to supply
electrical power for the operation of t20 volts at I5 amps
ac, single phase, 60 Hz, ac electrical lighting, appliance,
tool and motor toads
RECOIL STARTER -- Used Ior starting the engine man-
ually.
15-AMP AC CIRCUIT BREAKER _ Protects the genera-
tor against electrical overload Breaker is push to reset
type
AIR CLEANER -- Filters intake air as it is drawn through
the engine.
5.5 H P, ENGINE -- Provides the power needed to gen-
erate 2000 watts of AC output
12-VOLTS DC RECEPTACLE _ Recharge a dis-
charged 12 vofts automotive type battery through this
receptacle
FUEL TANK _ Tank holds 1 6 quarts of unleaded gaso-
line
HOW TO USE YOUR GENERATOR
IF YOU HAVE ANY PROBLEMS operating your
Generator, please call the Generator helpline at t-800.-
222-3136
CONNECTING ELECTRICAL LOADS
Use this generator to operate t20 volts, single phase, 60
Hz, ac lighting, appliance, tool and motor loads
o DO NOT connect 240 volts to 120 volts outlets.
DO NOT connect any 3-phase loads to panel recepta-
cles
,, DO NOT connect any 50 Hz loads to the generato_
Add up rated watts of all lights, tool, appliance and motor
loads you are powering at one lime This total should
NOT be greater than (a) generator's rated wattage
capacity, or (b) circuit breaker [ating of the receptacle
supplying power See "Don't Overload the Generator" on
Page 8
CHARGING A BATTERY
,&
A
WARNING: Storage Batteries give off
explosive gas while charging. An explo-
sive mixture will remain around a bat-
tery for a long time after it has been
charged. The slightest spark can ignite
the gas and cause an explosion. Such
an ezpiosion can shatter the battery
and cause blindness or other serious
injury.
WARNING: DO NOT uermit smoking,
ope_ flame, sparks or any other source
of heat around a battery. DO NOR use a
lighter or other flame for checldng bat-
tery fluid levels. We arprotective gog-
gles, rubber apror_ andrubber gDoves
when working around a battery. Battery
electrolyte fluid is an extremely caustic
sulfuric acid solution that can cause
severe burns. DO NOT permit fluid con-
tact with eyes, skin, c6othing, etc. If
spill occurs, flush area with clear water
immediately.
Your generator has the capability of recharging a discharged
12-vottautomotive or utility style storage battery. Do not usei
the unit to charge any 6-volt batteries. Do not use the unit to
crank an engine having a discharged battery. To recharge
12-vottbatteries, proceed as follows:
o
,, Check fluid level in all battery cells, if necessary, add
ONLY distilled water to cover separators in battery cells, o
Do Not Use Tap Water,
o If the battery is equipped with vent caps, make sure they
ate installed and are tight, o
If necessary, cfean battery posts or terminals.
Connectbatterychargecableconnectorplugto panefrecepta-
cleidentifiedbythe .,'_erdstz-VOL I b
12-VOLT D_C.
o Connect battery chargecable clamp with red handle to bat.
tery post el terminal indicated by a POSITIVE, POS or (+)
. Connectbatterychargecableclamp with black handle tobat-
terypost or terminalindicatedby a NEGATIVE, NEG, or(-)
,, Start engine see"ToStart the Engine" on Page 7) Letthe
engine run while battery recharges.
,' When battery has charged, shut down engine (see
"Stopping the Engine"below)
NOTE: Use an automotivehydrometer to test-battery stateof
charge and condition. Follow the hydrometer manufactureCs
instructions carefully. Generally, a battery is considered to be
at !00% state of charge when specific gravity of its fluid (as
measured by hydrometer) is 1.260 or highel'o
-_ _OPPQNG THE ENGINE
Unplug all electrical loads from generator panel recep-
tacles. Never start or stop engine with electrical
devices plugged in and turned on.
Let engine run at no-load for several minutes to stabi-
lize the internal temperatures of engine and genera-
tot
Move stop switch to "OflF position,
BEFORE STAF_'r0NG THE GEt,,_ER_'TOR
To operate tile engine you will need to dc_the following:
ENGINE OiL
Note: When adding oit to the engine crankcase in the
future, use only high quality detergenl oil rated with API
service classification SF and SG rated SAE 30 weight
Use no special additives
Select the oil's viscosity grade according to your expect-
ed operating temperature
colder _ 32'F _ warmer
5W30 SAE 30
Although multi-viscosity oifs (5W30, 10W30, etc )
improve starting in cold weather, these multi-viscosity oils
will result in increased oil consumption when used above
32"F Check your engine oil level more frequently to
avoid possible damage from running low on oil Oil sump
capacity is 20 ounces
o Place Generator on a level surface
o Cfean area around oil flit and remove oil dipstick
o Wipe dipstick ctean.
o Pour oil into the oil fill opening until oil reaches FULL
mark on the dipstick. DO NOT OVERFILL
o Install oil dipstick, hand tighten securely.
ADD GASOLINE
A
WARNING NEVER fill fuel tank indoors.
NEVER fill fuel tank when engine is running
or hot, DO NOT light a cigarette or smoke
when filling the fuel tank°
CAUTION: Do not overfill the fuel tank.
Always leave room for expansion.
Use regular UNLEADED gasoline with the Generator
engine Regular leaded gasoline may also be used if
UNLEADED is not available Fuet tank capacitY is t 6
U S quarts
IMPORTANT: It is irnportan_ to prevent gurr, deposits
from forming in essential fuel system parts such as the
carburetor, fuel filter, fuel hose or tank during storage
Also, experience indicates that aicohot-bfended fuels
(called gasohol, ethanol or methanol) can attract mois-
ture which leads to separation and formation ol acids
during storage Acidic gas can damage the fuel system
of an engine while in storage
To avoid engine problems, the fuel system should be
emptied before, storage of 30 days or longer Drain the
gas tanlq start the engine and let it run until the fuel lines
and carburetol Use fresh fuel next
are
empty
season
See "Storage" Instructions on page 1! for additional
I information
Never use engine or carburetor cleaner products in the
fuel tank or permanent damage may occur
Clean area around fuel fill cap, remove cap
Add "UNLEADED" regular gasoline, slowly, to fuet
tank.
o install fuel cap and wipe up any spilled gasoline
"TO START THE ENGINE
Unplug all electrical loads from generator receptacles
before starting the engine. NEVER start or stop
engine with electrical devices plugged into the panel
receptacles and turned on.
Move engine CHOKE CONTROL LEVER to "RUN"
position
loke Control Lever
o Move STOP SWITCH to "ON" position
Sto Switch
Ifengineiswarm,closechokeonlypartwayorleave
itfullyopenAwarmengineneedslesschotdngthan
acotdengine
Graspstartergripandpullslowlyuntityoufeelsome
resistanceLetropereturnslowlyThenpullcordout
withrapidfullarmstrokeLetropereturnsfowlyDo
notletrope"snapback"againststarter
Ifengine"hunts"orfaltersafterstarting,apptychoke
untilenginebeginsrunningsmoothlyThenreturnthe
choketotileopenpositionifenginecontinuesto
hunt,youmayneedtohavethecarburetoradjusted
SeeSERVICEANDADJUSTMENTSonPage10
DON'T OVERLOAD 'THE GENERATOR
This generatol is equipped with one 15-amp circuit
breaker The receptacle is protected against electrical
overload with the 15-amp breaker Overloading a genera-
tor in excess of its rated wattage capacity can result in
damage to the generator and to connected electrical
devices Observe the following, to prevent overloading
tile unit:
The _atedwattage of lights can be taken from light
bulbs The rated wattage of tools, appliances and
motors can usually be found on a data plate or decal
affixed to the device
!I the appliance, tool or motor does not give wattage,
multii31y120 volts times ampere rating to determine
watts (volts x amps = watts)
Some electric motors, such as induction types, require
about two and a half _imes more watts of power for
starting than for running This surge of powel lasts
only a few seconds when starting such motors Make
sure you allow for this high starting wattage when
selecting electrical devices to connect to your genera-
tot, First, figure the watts needed to start the largest
motor Add to that figure the running watts of all
other connected loads
The Wattage Reference Guide below is provided to
assist you in determining how many items your generator
can operate at one time
Add up the totat wattage of all electrical devices to be
connected at one time This total should NOT be
greater than the generator's wattage capacity
WATTAGE REFERENCE GUIDE
RUNNING
WA'Tf'S
*Air Conditioner (12,000 Btu) 1700
Battery Charger (20 amp) 500
Bolt Sander (3") 1000
Chain Saw 1200
Circular Saw (6-I 2P') 800 to t000
Coffee Maker 1000
"Compressor (t HP) 2000
"Compressor' (314 HP) I800
"Compressor (tl2 PiP} t400
Curling Iron 700
*Freezer 500
Disc Sander (9_) !200
Edge Trimmer 500
Electric Nail Gun 1200
Electric Range (one element) 1500
Etectric Skillet I250
*Furnace Fan (1/3 HP) !200
Hair Dryet 1200
Hand Drill (1°) 1100
Hand Drill (t12") 750 to 1000;
Hand Drill (318") 500
Hand Drill (ti4") 250
Hedge Trimmer' 450
RUNNING
WATTS
Impact Wrencll . .. 500
*,Jet Pump ....................... 800
Lawn Mower ................ t 200
Light Bulb . !00
Microwave Oven ................. 700
*Milk Cooler ......................... 1100
Oil Burner on Furnace ..................... 300
Oil Fired Space Heater (140,000 Btu) . . 400
Oil Fired Space Heater (85,000 Btu} ..... 225
Oil Fired Space Heater (30.000 Btu) . 150
*Paint Sprayer, Airless (ti3 HP) . . 600
Paint Sprayer, Airless (handhold) ........... t50
Radio .............................. 50 to 200
*Refrigerator ............ 600
Siow Cooker .... 200
*Submersible Pump (1-I/2 HP) ....... 2800
*Submersible Pump (1 HP) .......... 2000
*Submersible Pump (I/2 HP) .................... 1500
Sump Pump .......................... 600
'Table Saw (10") ...................... 1750 to 2000
Television ............... 200 to 500
Weed Trimmer ............................. 500
* Allow 2-1/2 times the listed watts for starting these devices
8
CUSTOI'#_E_ RESPONS_BFLITJES
MAINTENANCE SCHEDULE
FILL fN DATES AS YOU COMPLETE HOURLY OPERATING INTERVAL
REGULAnSERVICE
i
Eveq, 25 I Every 50 Evaq, 100
1 Before Each Hours or 1 Hours or Hou_s or
Use Yearly Yeady SERVICE DATES
MAINTENANCE TASK I ......... Yeady
ENGINE .................... l
Check oil level ............... I X ........................
i
Change engine oil _ !
Service air cieaner I X'" }
Prepare for storage Prepare unit for storage if it is to remain idle for longer t 1
]
lthan30day ! I
$ Change oil niter iirst 8 hours of operation then after every 50 hours
Change sooner when operating under heavy load or high ambient temperature
"" Clean more o{ten under dirty or dust,,, conditions.
PRODUCT SPECIFICATIONS _ Once a year you should clean or replace the spark
plug and clean or replace the air filter A new spark
ptug and clean air fittel assure proper fuel-air mixture
and hetp your engine run better and last longer
Generator Specifications
Rated Maximum Power
RatedVoltaae
Ratedmaximum
LoadCurrent
Rated Frequencf
Phase
2000Watts _2.:OkW)
120 VoltsAC
16,7AC AmPeres
60Hz at 3600 mm
Single Phase
Engine Specifications
RatedHorsepower
Oisp!acement
5.5 at 3600rum
11,57cubicinches
Spai'kPlug: Type: Champion RCJ8
or equivalent
Set Gap to: 0.030 inch [0.76turn)
GasofineCapacity 1.6 U,S, ctuaris
Oil I20oz. ,capa,gity),, SAE 30weiahl
SolidSlate Ignition 00125 inch
Air Gap
GENERAL RECOMMENDAT}ONS
The warranty of the Generator does not cover items that
have been subjected to operator abuse or negligence To
receive full value from the warranty, operator must main-
tain Generator as instructed in this manual
Some adjustments witI need to be made periodically to
properly maintain your Generator
Atl adjustments in the Service and Adjustments section of
this manual should be made at least once each season
Follow the recommendations in the "Customer
Responsibilities" chart above
CAUTION: Disconnect spark plug wire from
spark plug and place wire where it cannot
come in contact with your spark plug before
working on your generator,
GENERATOR _aAINTENANCE
Generator maintenance consists of keeping the unit clean
and dry Operate and store the unit in a clean dry envi-
ronment where it will not be exposed to excessive dust,
dirt, moisture or any corrosive vapors Cooling air slots in
the generator must not become clogged with snow,
leaves,or any other foreign material
Check the cleanliness ol the generator frequently and
clean when dust, dirt, oil, moisture or other foreign sub-
stances are visible on its exterior surface
Note: We DO NOT recommend using a garden hose to
clean generator Water can enter the engine fuel system
and cause problems, in addition, if water enters the gen_
orator through cooling air slots, some of the water wilt be
retained in voids and cracks of the rotor and stator wind-
ing insulation, Water and dirt buildup on the generator
internal windings will eventually decrease the insulation
resistance of these windings
To clean the Generator:
Use a damp cloth to wipe exterior suriaces clean
A soft, bristle brush may be used to ioosen caked on
dirt, oil, etc
A vacuum cleaner may be used to pick up loose dirt
and debris
Low pressure air (notto exceed 25 psi) may be used
to blow away dirt inspect cooling air slots and open-
ings on the generator These openings musl be kept
clean and unobstructed
CAUTION:NeverInsertanyObjectortool |
A throughtheair'coolingslots,evenifLhe
J
e_._nqine is not running
ENGINE MAIN'TENANCE
CHECKING OIL LEVEL
Oil level should be checked prior to each use or at least
every 5 hours of operation Keep oil level maintained
CHANGING ENGINE OIL
Change oil aftel first 8 hours of operation Change oil
every 50 hours thereafter-. If you are using your
Generator under extremely dirty or dusty conditions, or in
extremely hot weather, change oil more often
Change oi! wl_ile engine is still warm from running, as fol-
lows:
, Drain fuel tank by running Generator until fuel tank is
empty
Clean area around oil drain plug, remove oil fi!l
cap/dipstick Wipe dipstick clean
o Tip your Generator as shown Remove oil drain plug
to drain oi! completely into a suitable container When
crankcase is empty, return the Generator to its upright
position
\
SERVICE AIR CLEANER
Your engine willnot run properly and may be damaged if
you run it using a dirty air cleaner
Clean or _eptace the air cleaner once every 25 houls of
operation or once each year, whichever comes first
Clean or replace more often if operating under di_ or
dusty conditions Replacements are available at your
local Sears Authorized Sewice Center
To clean or replace the air cleaner, follow these steps:
o Loosen screw
o Remove air cleaner cover carefutty The screw will
stay with the cover
SGRb-'W AtR
COVER
{,
Remove the air filter and examine it for damage
To service the paper' air filter clean it by tapping it
gently on a flat surface. If very dirty or damaged,
replace the air filter DO [,tOT oil the air filter
Reassemble all parts and fasten securely to the
engine with the screw
Fill engine crankcase with recommended oil untit oil
Ievel is at FULL point on dipstick Do not overfill
above that mark About 20 ounces is _equired POUR
SLOWLY
When engine crankcase is fitied to proper level, install
and tighten oil captdipstick
CLEANIREPLACE SPARK PLUG
Change the spark plug every !00 hours of operation or
once each year, whichever comes first This wilt help
your engine to start easier and run better. Replace with
Champion RJ-SC or equivalent type spart( plug. Set
spark plug gap 0.030 inch (O.76mm).
SET PLUG GAP AT 0.030 inch
{0.76 ram)
\
\
]0
ENGINE SPEED
A
CAUTION: Engine speed was property
adiusted at the factory and should require
no additional adjustment,, Do not a_empt to
change engine speed° tf you believe the
engine is running too fast or too stow, take
your generator to an authorized Sears
Sen, ice Center for repair and adjustment,
CHANGING ENGINE GOVERNED SPEED
WILL VOID ENGINE WARRANTY.
Your generator engine runs a_a constant speed This
constant operating speed is maintained by a mechanical,
flyweight type, fixed speed governor DO NOT try to
adjust the governed speed setting for the following rea-
sons:
.. High engine speeds are dangerous and increase the
risk of personal injury or damage to equipment
Low engine speeds impose a heavy load on the
engine when sufficient engine power is not available
and may shorten engine life
The generator will supply correct rated ac frequency
and voltage only at tile proper speed Some connect-
ed electrical devices could be damaged by incorrect
frequer_cy andlor voltage
CARBURETOR
tf you thint.',your carburetor needs adjusting, see your
nearest Sears Sel_dce dealer Engine performance may
be affected above 4,000 feet in altitude To improve
engine performance, see your nearest Sears Service
dealer
GENERAL
The generator should be started at least once every
seven days and allowed to run at least 30 minutes If this
cannot be done and you must store the unit for more
than 30 days, use the following information as a guide to
prepare it for storage,
LONG TERM STORAGE INSTRUCTIONS
WARNING: NEVER store engine with fuel
in tank indoors or in enclosed, poorly VentF
lated areas where fumes may reach an
open flame, spark or pilot light as on a fur-
nace, water heater, clothes dryer or other
gas appiiance_
It is important to prevent gum deposits from forming in
essential fuel system parts such as the carburetor, fuel
filter, fuel hose or tank during storage Also, experience
indicates that alcohol-blended fuels (called gasohol,
ethanol or methanol) can attract moisture which leads to
separation and formation of acids during storage, Acidic
gas can damage the fuel system of an engine white in
storage
To avoid engine problems, the fuel system should be
emptied before storage of 30 days or longer Follow
these instructions:
_ROTECT FUEL SYSTEM
WARNING: Drain fuel into approved con-
tainer eutdoors, away from open flame.. Be
sure engine is cool. Do not smoke..
Remove all gasoline from the fuel tank to prevent gum
deposits from forming on these parts and causing
possibte malfunction of engine
Run engine until engine stops from lack of fueI
CHANGE OIL
Whiie engine is still warm, drain oil from crankcase Refill
with recommended grade
OIL CYLINDER BORE
_. CAUTION! Avoid spray from spark plug
hole when cranking engine stowiyo
Remove spark plug and pour about 1/2 ounce (15rnl)
of engine oil into the cylinder. Cover spark plug hole
with rag Crank slowly to distribute oil.
Install spark plug Do not connect spark plug wire
GENERATOR:
Clean the generator as outlined on Page 9 ('%o Clean
the Generator")
Check that cooling air slots and openings on genera-
tor are open and unobstructed
OTHER STORAGE TIPS:
o Do not store gasoline from one season to another
Replace your gasoline can if your can starts to rust
Rust and!or dirt in your gasoline wil! cause problems
. If possible, store your unit indoors and cover it to give
protection from dust and dirt BE SURE TO EMPTY
THE FUEL TANK.
Cover your unit with a suitable protective cover that
does not retain moisture
Store generator in clean, dry aTea
IMPORTANT: NEVER cover your Generator while
engine and exhaust area are warm
]]
PROBLEIVl
Engineisrunning,but no
ACoutpuI isavailable
Enginerunsgoodatno-loadbut"bogs
down"whenbads are connected
Enginewillnol start; orstads
andrunsrough
CAUSE
1One ofthecircuilbreakersisopen
2 Faultingenerator
3.Poorconnectionor detective
cordset
4 Connecteddeviceisbad
1 Shortcircuitin a connectedload
2 Enginespeedis toostow
3 Generatoris overloaded
4 Shortedgeneratorci_cuit
I Run/StopSwitchsettoSTOP
2 Diriyaircteaner
30ul ofgasoline
4.Stalegasoline
5 Sparkplugwire notconnected
tosparkplug
6 Badsparkplug.
7 Waterin gasoline
80verchoking
9 Excessivefyrichfuelmixture.
10,Intakevaivestuckopenor'closed
11Enginehaslostcompression
12,{nlakevalvestuckopenor closed.
CORRECTION
1 Resetcircuitbreaker"
2 ContactSea_'sServiceFacility
3 Checkandrepair.
4 Connectanotherdevicethat
isin goodcondition
1 Disconnectshortedelectrical
load
2 ContactSearsServiceFacility
3 See"Don'tOverloadthe
Generator"
4 ContactSearsServiceFacility
t Setswitchto RUN.
2 Cleanor reptaceair cleaner
3 Fillfueltank
4 Draingastank;fill withfreshfuel
5 Connectwiretosparkplug
6 Replacesparkplug
7 D_aingastank;iill withfreshfuel
8 Openchokefullyand crankengine
9 ContactSearsServiceFacility
10 ContactSearsServiceFacility
11 ContactSearsServiceFacility.
12 ContactSearsServiceFacifity
Engineshutsdownduringoperation t Out ofgasoline 1 Flitfuef tank
2,Lowoiltevel, 2, Fillcrankcaset{)properlevel,
Enginelackspower 1 Loadistoohigh 1 See"Don'tOverloadlhe Generator"
2 Dirt'),airfitter 2 Replaceair filter
Engine"hunts"orfalters t
.
1Chokeis openedtoosoon
2 Carburetoris runningtoorich
or toolean
Movechoke16halNvaypositionuntil
enginerunssmoothty
ContactSearsServiceFacility
/2
GRAFTS_AN2D0O _&_attAC Generator 580.327700
Oontro! Panel _ E}_pioded View and Parts List
!
/
\\
S
6
3
4
10
ITEM PART NO. DESCRIPTION
1 9e_37
2 66818
3 99_7
4 93418
5 845430
6
7 Tb_7-E)
8 83514
9 84198
10
__ PANEL
12OV15Aobq-LET
P_PAOTOR t25
12VDOCXJTLE7
PHLUPSI-F_D _ 35 X I8_4_4LG_
13AF_F_-TAININ_
15AACC_RCJJ_BPEAKEPrM_t =PESET
1CADC CRGJ[FBqEikKEP_AUTORESET
CAP,CIRCUIT
QTY.
t
2
'1
1
4
2
I
1
!
1
Drm_,ing No 21348 13
CFIAFTSMAN 2000 Watt AC Generator 580,327700
Main Unit -- Exploded View
25
Z7
6
15 "\
5
2
55
5
28
Dla_ving No 99695 ]4
CRAFFS!_&_,_ 2000 Wa_ AC Generator 580.327700
r_ainUnit -- Parts List
ITEM PART NO. DESCROPTION
't 99685
2 67210A
3 99681
4 99683
5 99684
6 99687J
7 65791
8 67451
9 99849
t0 99688J
I1 99884
12 99896
!3 99852
14 99686
15 49813
16 66449L
17 99850
t8 77026
t9 75402
20 21206
2I 86292
22 52858
23 87841
24 39414
25 97912
26 97082
27 99368
28 97178
29 21724
30 81895
31 97998
32 96409
33 93639
34 20024
35 89685
36 9774'1
37 65795
38 66849A
39 86307
40 22'129
4t 77395
42 87680
43 26850
44 40945
Handle
Ground Decal
Frame
Briggs 5 5 HP -- VS Engine
Base Plate
Rotor Assy
Bearing
Flat Washer (Special)
HHCS, 5/16-24 x 5"
Stator Assy
Control Panel Assy_
PPHMS, 910 x !-1/4 Self Drill
Control Panel Decal
RBC End Stator Plate
Hex Nut M6-1,0
Stator Bolt
Bearing Cover
Data Sheet Decal (Back Side)
Pushnut, 1/2" Die,
Diamond Tread Tire
HHCS. 9IO-16 x 3/4" Self Drill
Locking Nut M6-1.25
Vibration Mount
HHCS, M8-1,0 x 35
Carriage Bolt 1/4-20 x 2-!/4 LG
Ffandle Clip
Anti-Scratch Pfate-SS
Handle Knob
Ext, Cord Holder
Plug 3!4" Square Cap
Square Neck Eye Bolt
1-800 Number Decal
Danger Instructions Decal
Start Instructions Decal
Control Box Grommet
Axle Assy
Battery Charge Rectifier
Taptite M5-08 x 20 Screw
HHCS, 5/16-24 x 3/4"
Lock Washe r-5/16
Flange Lock Nut M6
Wing Nut M6-1.0
Shakeproof Washer, M6-1/4
SHCS, M6-1 0 x 20
QTY°
1
1
2
1
1
t
t
1
1
1
1
2
1
1
1
4
1
1
2
2
tO
2
2
2
1
2
2
2
1
4
I
1
1
1
1
1
1
1
4
5
4
1
2
1
Drawing No 99696 I5
CrmF_SMAN 2000 Watt AC Generator u8u.3zz700
BRIGGS & STRATTON 4-CYCLE ENGINE I288t2-2393-Ai
7
I i I
a
_z4
12£4
L=J
Bsr__%-i
L_____J
i;_r# i
i
®
634A
_ 134
......... ,_.._ '-,,.%
X_
,15
CRAFTSMAN 2800 Wa£_ AC u_enera,,o[ 580.c,z_ 700
BR1GGS & STR_'TOK 4-CYCLE ENGgNE _288't2-2393-A1
o8 f%
968
967'
209
202
_ 971
163
358 GASKET SET
3@ 20@ 1i6 0 668(_ 116AL._
9A
51
7
]7
CRAFTSMAN 2000 Watt AC Generator 580.327700
BRIGGS & STRATTON 4-CYCLE ENGINE t_881=-239o-Al
305
37
304
305
332
! '
]8
CRAFTS{_AI"4 200{_ _fatt AC G_nerator 580,327700
BRtGGS & $TRATTON 4-CYCLE ENGQNE "_28812-23£3-A'_
- 27
43
I5
20 22
615 _
23O
6!6
1!02 _)
24
CRAFTSMAN 2000 Watt AC Generator _80-.o_'_""_700
BRIGGS ° _-':"_z_"-_" ,_.p,vm --c,. _._,r,. ,._ _uN =-v ,,.,_= =NGINE 128812-2393-At
57 "
56
_Lb.
[.......
4_i
GASKET S_" ,_
9i83
_._ _7_,,_d_ -_,_
9.77 CARB#R-I_irOR _t
GA_K_ _ SNT
110 O
Ol "63
_!_,._ '834 _34A
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Craftsman 580327700 Owner's manual

Category
Power generators
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages