ProFire 27R Owner's manual

Category
Barbecues & grills
Type
Owner's manual
REV 3/2016
Owners Manual & Installation Instructions
For questions about features, operation/performance, parts or service, call 888.781.4657 or
Visit our website at www.profiregrills.com
WARNING: You must read this manual carefully and completely before using your grill to ensure
proper operation, proper installation, proper servicing and to reduce the risk of fire, burn hazard
and/ or other injury.
DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flames.
3. Open lid.
4. If odor continues, keep away from the appli-
ance and immediately call your gas supplier or
your fire department.
Leaking gas may cause a fire or explosion which
can cause serious bodily injury, death, or damage
to property.
WARNING
1. Do not store or use gasoline or other flamma-
ble liquids or vapors in the vicinity of this or
any other appliances.
2. An LP cylinder not connected for use shall not
be stored in the vicinity of this or any other ap-
pliances.
WARNING
Follow all leak-check procedures carefully in this
manual prior to barbecue operation. Do this even
if the barbecue was dealer-assembled.
WARNING
BEFORE LIGHTING:
Do not ignite this appliance without first reading
the Burner Ignition section of the manual.
THIS GRILL IS FOR OUTDOOR USE ONLY.
If your appliance is a LP unit and stored indoors, de-
tach and leave LP cylinder outdoors.
NOTICE TO INSTALLER: These instructions must
be left with the owner and the owner should keep
them for future use.
MH49347
Congratulations!
You have purchased the finest Gas grill ever built. Every effort has been made to use only the finest
materials available and to design the grill to give many years of trouble free service. If you have any
questions or comments please feel free to contact us at ProFire.
We thank you for buying the “Made In USA” professional ProFire Gas Grill.
MODEL IDENTFICATION
Your ProFire Gas Grill is identified by a model number and a serial number. Always use both
the model and serial numbers when contacting ProFire about your grill. For future reference,
take the time now to record the model and serial numbers below:
MODEL NUMBER________________SERIAL NUMBER______________________
DATE PURCHASED__________________
How to contact us phone: 888-781-4657, Fax: 888-781-3965, E-mail: [email protected] or
write: Customer Service, ProFire Grills, 5565 North 124th Street, Butler, WI 53007.
2
IMPORTANT SAFETY INFORMATION
DANGER
Failure to follow the Dangers, Warnings and Cautions contained in this Owner’s Manual may result
in serious bodily injury or death, or in a fire or an explosion causing damage to property.
The installation of this appliance must conform with local codes or, in the absence of local codes, either the National Fuel Gas Code,
ANSIZ223.1NFPA54 or CAN/CGA-B149.1, Natural Gas Installation Code or CAN/CGA-B149.2, Propane Installation Code.
The outdoor cooking gas appliance is not intended to be installed in or on recreational vehicles and/or boats.
This outdoor cooking gas appliance is intended for use outdoors and shall not be used in a building, garage or any other enclosed
area.
Minimum clearance of 12 inches from the back and sides of the grill to adjacent combustible construction must be main-
tained. This outdoor cooking gas appliance shall not be located under overhead unprotected combustible construction.
The utilization of an external electrical source requires that when installed, this outdoor cooking gas appliance must be electrically
grounded in accordance with the local codes or, in the absence of local codes , with the National Electrical Code, ANSI/NFPA 70, or
the Canadian Electrical Code, CSA C22.1. Keep any electrical supply cord, or the rotisserie motor cord and the fuel supply hose
away from any heated surfaces.
Keep your grill in an area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
DO NOT obstruct the flow of combustion and ventilation air to this appliance. Keep the ventilation openings of the enclosure free and
clear from debris.
Check all gas connections for leaks with soapy water solution and brush. Never use an open flame. (Reference page 10 for leak test
procedure).
Check flexible hoses for cuts and wear that may affect the safety before each use.
Never use charcoal in ProFire Gas Grill.
Never use the grill in a windy area.
Never use the grill without the drip pan installed and pushed all the way to the back of the grill. Without the drip pan, hot grease and
debris could leak downward and produce a fire hazard.
The pressure regulator and hose assembly supplied with the ProFire Gas Grill must be used. Replacement pressure regulators and
hose assemblies must be those specified by ProFire.
CALIFORNIA PROPOSITION 65-WARNING: The burning of gas cooking fuel generates some by-products which are on the list of
substances known by the State of California to cause cancer or reproductive harm. California law requires businesses to warn cus-
tomers of potential exposure to such substances. To minimize exposure to these substances always operate this unit according to
the use and care manual, ensuring you provide good ventilation when cooking with gas.
3
In Massachusetts: All gas products must be installed using a “Massachusetts” licensed
plumber or gasfitter. A “T” handle type manual gas valve must be installed in the gas
supply line to this appliance. This applies to permanently installed natural gas and pro-
pane installations. This does not apply to propane portable installations using a 20 pound
tank.
4
IMPORTANT GAS SAFETY INFORMATION
Each appliance is set and tested at the factory for the type of gas supply to be used. Identify the type of gas, either
Natural Gas or LP Gas and make sure that the marking on the data plate (rating plate) matches the gas being sup-
plied to the grill.
All gas connections should be made by a qualified technician and in accordance with local codes and ordinances.
The installation must conform with local codes or, in the absence of local codes, with either the National Fuel Gas
Code, ANSIZ223.1NFPA 54, or CAN/CGA-B149.1, Natural Gas Installation Code or CAN/CGA-B149.2, Propane
Installation Code.
WARNING:
CHECK TO ENSURE THAT THE GAS SUPPY HOSE DOES NOT COME IN CONTACT WITH ANY
HOT SURFACE OF THE GRILL
NEVER CONNECT THE GRILL TO AN UNREGULATED GAS SUPPLY.
LP GAS (LIQUIFIED PETROLEUM/PROPANE)
If your grill is factory built for LP gas, the regulator supplied is set for 11” water column and is for use with LP gas
only. The factory-supplied regulator and hose must be used with a 20 lb. LP Cylinder.
Do not attempt to disconnect the gas regulator and hose assembly or any gas fitting while your grill is in operation.
A dented or rusty liquid propane cylinder may be hazardous and should be checked by your liquid propane suppli-
er. Do not use a liquid propane cylinder with a damaged valve.
Although your liquid propane cylinder may appear to be empty, gas may still be present, and the cylinder should
be transported and stored accordingly.
If you see, smell or hear the hiss of escaping gas from the liquid propane cylinder
1. Move away from liquid propane cylinder.
2. Do not attempt to correct the problem yourself.
3. Call your fire department.
LP GAS SAFETY REQUIREMENT
The LP Gas Supply Cylinder must be constructed and marked in accordance with the Specifications for LP Gas
Cylinders of the US Department of Transportation (D.O.T.) or the National Standards of Canada CAN/CSA-B339,
Cylinders, Spheres and Tubes for the Transportations of Dangerous Goods, and Commission, as applicable and
1. Provided with a listed overfilling prevention device.
2. Provided with a cylinder connection device compatible with the connection for outdoor cooking appliances.
It must be provided with a shut-off valve terminating in gas tank, valve outlet. It must include collar to protect the
cylinder valve. The cylinder supply system must be arranged for vapor withdrawal.
Do not operate the gas grill indoors or in any enclosed area. If the gas grill is not in use, the gas must be
turned off at the supply cylinder. If the grill is to be stored indoors, disconnect the gas supply cylinder
and leave the cylinder outdoors.
Only original factory parts should be used when repairing your grill. The use of unapproved or untested
parts will void your warranty and may cause serious personal harm.
INTRODUCTION.......................................................................2
TABLE OF CONTENTS.............................................................5
SAFETY REQUIREMENTS....................................................3,4
GAS REQUIREMENTS.............................................................6
NATURAL GAS HOOK-UP.........................................................7
L.P. HOOK UP AND TANK REQUIREMENTS..........................8
LOCATION REQUIREMENTS...................................................9
CUT OUT DIMENSIONS.........................................................10
LEAK TESTING........................................................................11
ADJUSTING FOR PROPER FLAME.......................................12
INSTALLATION CHECK-LIST..................................................13
GRILL LIGHTING INSTRUCTIONS....................................14,15
USING YOUR ProFire GAS GRILL............................... .....16,17
Side burners...............................................................16,17
Rear broiler & rotisserie..............................................17,18
CARE & MAINTENANCE....................................................19,20
TROUBLESHOOTING.............................................................20
PARTS LIST & DIAGRAM........................................................21
WARRANTY.............................................................................22
INDEX......................................................................................23
5
TABLE OF CONTENTS
Verify the type of gas supply to be used, either Natural or L.P., and make sure the marking on the ap-
pliance rating plate agrees with that of the supply. The rating plate is located on the rear of the grill be-
hind the side burners or on the right side behind the faceplate. An "X" will be marked next to the type
of gas that the unit is orifice for.
L.P. gas installation requires the use of a regulator set for 11"W.C. pressure. Natural gas installation
requires a pressure of 7"W.C.
An installer supplied gas shut-off valve must be installed in an easily accessible location. All installer
supplied parts must conform to local codes, or in the absence of local codes, with the latest edition of
the National Fuel Gas Code, ANSI Z223.1
All pipe sealants must be an approved type and resistant to the actions of L.P. and Natural gases.
Never use pipe sealant on flare fittings. All gas connections should be made by a competent technician
and in accordance with local codes and ordinances. In the absence of local codes, the installation must
comply with the latest edition of the National Fuel Gas Code, ANSI Z223.1
Gas conversion kits are available from your dealer or ProFire. When ordering have available the model
number, and type of gas (L.P. or Natural) which you need the ProFire grill orificed for. To convert to LP
gas the model # will be GCKLP followed by the model # of your grill. To convert to Natural gas the
model # will be GCKNAT followed by the model number of your grill.
TOTAL GAS CONSUMPTION
of the ProFire gas grill with all burners on "HIGH":
MODEL BTU MODEL BTU
48G 88,000 36G 66,000
48S 96,000 36R 79,500
48R 101,500 40S 74,000
48RS 109,500 40R 87,500
27G 44,000 SINGLE SIDE BURNER 15,000
27R 57,500 DOUBLE SIDE BURNER 30,000
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5kPa.). This ap-
pliance must be isolated from the gas supply piping system by closing its individual manual shut-off
valve during any pressure testing of the gas supply piping system at test pressures equal to or less
than 1/2 PSIG (3.5kPa.).
The installation of this appliance must conform with local codes or, in the absence of local codes, to the
latest edition of the National Fuel Gas Code, ANSI Z223.1. Installation in Canada must be in accord-
ance with the Standard Can1-b149.1 or .2 (installation code for gas burning appliances and equipment)
and local codes.
GAS REQUIREMENTS
6
NATURAL GAS HOOK-UP
Connection: 3/8-flare male fitting in left rear corner of unit
Operating pressure :7.0" W.C.
Check with your local gas utility company or with local codes for instructions on installing gas sup-
ply lines. Be sure to check on type and size of run, and how deep to bury the line. If the line is too
small the ProFire gas grill will not function properly. Any joint sealant used must be an approved type
and be resistant to actions of L.P. and Natural gases. Do not forget to place the installer supplied gas
valve in an accessible location. Check local codes. Consult your local gas dealer. In the absence of
local codes, installation must conform to the latest edition of the NATIONAL FUEL GAS CODE, ANSI
Z233.1
The grill is designed to operate on Natural Gas at a pressure of 7" water column (W.C.) (1.75kPa)
unregulated. Check with your gas utility for local gas pressure. Use of your grill at pressures other
than approximate 7" water column could affect the performance of your grill and requires installation of
a natural gas regulator set at 7" W.C.
The grill and its individual shut-off valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5kPa). The grill
must be isolated from the gas by closing its valves during any pressure testing of the gas supply sys-
tem at test pressures equal to or less than 1/2 psig (3.5kPa).
Never use LP gas in a unit designed for natural gas. If you wish to convert
your grill from one type of gas to the other you may order a gas conversion kit
from ProFire or your dealer.
7
GAS REQUIREMENTS
A dented or rusty L.P. tank may be hazardous and should be checked by your L.P. supplier. Never use a cylinder
with a damaged valve. Cylinder dimensions should be approximately 12 inches in diameter & 18” inches high. The
L.P. cylinder must be constructed and marked in accordance with the specifications for L.P. gas cylinders of the U.S.
Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339, Cylinders, Spheres and
Tubes for Transportation of Dangerous Goods.
The propane gas cylinder valve must be equipped with a cylinder connection coupling device, described as Type 1 in
the Harmonized ANSI standard ANSI Z 21.58 & CGA 1.6-M95-1995 with addenda Z 21.58. This device is commonly
described as an Acme Thread Quick Coupler (see figure 1 below). The gas must be turned off at the supply cylinder
when the unit is not in use. If the appliance is stored indoors the cylinder must be disconnected and removed from
the appliance. Cylinders must be stored outdoors in a well-ventilated area out of the reach of children.
The cylinder supply system must be arranged for vapor withdrawal and must include a collar to protect the cylinder
valve. Disconnected cylinders must not be stored in a building, garage, or any other enclosed area. The grill is de-
signed to operate on Propane gas regulated at a gas pressure of 11" water column (W.C.) (2.7kPa). A regulator ad-
justed to this pressure must be installed in the gas supply line before the grill is connected to the propane source.
Use only the type regulator and hose specified by ProFire.
8
LP GAS CONNECTION AND TANK REQUIREMENTS
Only 20 lb. cylinders equipped with an OPD (Overfill Protection Device) should be used with your ProFire grill. Only
one propane cylinder may be located in an enclosure or cart. Extra spare cylinders must be stored outdoors out of the
reach of children and outside of any building, garage or other enclosed area. READ AND FOLLOW ALL WARNINGS
PROVIDED WITH PROPANE CYLINDERS. Never locate a cylinder under or near the barbecue unless sufficient venti-
lation & shielding is provided to prevent any heating of the cylinder, regulator and hoses.
Fig. 1
LP GAS CYLINDER HOOK-UP
20 LB (5 GALLON) LP CYLINDER
DO NOT PLACE MORE THAN ONE
CYLINDER IN THE ENCLOSURE AT
ANY TIME.
WARNING
VENTS REQUIRED ON ENCLO-
SURES FOR LP CYLINDER (SEE
NOTE)
WARNING
BRASS COUPLING
1/2 NPT X 3/8
FLARE
HI PRESSURE
LP HOSE
ASSEMBLY
LP REGULATOR
TYPE 1
CAUTION: PROVIDE ADEQUATE VENTILATION HOLES (OPENINGS) IN THE ENCLOSURE FOR SAFETY
PURPOSES IN THE EVENT OF A GAS LEAK.
NOTE: An enclosure for LP gas cylinder must be vented on the level of the cylinder valve and at floor level. The effec-
tiveness of the openings(s) for purposes of ventilation shall be determined with the LP gas supply cylinder in place. This
shall be accomplished by one of the following:
A. One side of the enclosure shall be fully open; or
B. For a cylinder enclosure having four sides, a top and a bottom, and intended for installation in a built-in enclosure.
1. At least one ventilation opening shall be provided on the exposed exterior side of the enclosure located within 5inch-
es (1.27mm) of the top of the enclosure and unobstructed. The opening(s) shall have a total free area of not less the
1 in2q/lb (14.2 cm2/kg) of stored fuel capacity.
2. At least one ventilation opening shall be provided on the exposed, exterior side of enclosure 1 in. (25.4mm) or less
from the floor level and shall have a total free area of not less than 1/2 in2/lp (7.1 cm2kg) of stored fuel capacity.
The edge shall be no more than 5 in (127mm) above the floor level.
3. Every opening shall have a minimum dimension so as to permit the entrance of 1`/8 in (3.2mm) rod.
Propane Cylinder Ventilation Requirements (See Page 8)
Household Propane Service
It is recommended that the same ventilation requirements be used for household propane
service as propane cylinders.
Clearance to combustible construction
Minimum clearance from sides and back of unit to adjacent combustible construction below top of
unit, 12" from sides and back. Minimum horizontal clearance from sides and back of unit to adjacent
vertical combustible construction extending above top of unit 12" from sides and back.
Clearance to non-combustible construction
It is desirable to allow at least 6" side clearance to non-combustible construction above the cooking
surface for counter space. When using the rotisserie the space is essential for the motor and skewer
clearance. The ProFire gas grill can be placed directly adjacent to non-combustible construction be-
low the cooking surface.
Insulated Sleeve
If the ProFire gas grill is to be placed into a combustible enclosure an approved insulated sleeve is
necessary and is available from your dealer. Use only the ProFire insulated sleeve which has been
designed and tested for this purpose.
Location
When determining a suitable location take into account concerns such as exposure to wind, proximity
to traffic paths and keeping any gas supply lines as short as possible. Locate the grill only in a well-
ventilated area. Never locate the grill in a building, garage, breezeway, shed or other such enclosed
areas without an approved ventilation system. During heavy use the grill will produce a lot of smoke.
Ensure that there is adequate area for smoke to dissipate.
Ventilation Hood
When installing your grill under overhead unprotected areas the use of a ventilation hood with a mini-
mum of 600CFM (1200 CFM for 48" ProFire units) is necessary. A proper ventilation hood is availa-
ble from your dealer or from ProFire.
9
LOCATION REQUIREMENTS
10
GRILL AND ACCESSORY CUT-OUT DIMENSIONS FOR BUILT-INS
CHECK ALL GAS SUPPLY FITTINGS FOR LEAKS BEFORE EACH USE.
Keep a spray bottle of soapy water near the shut-off valve of the gas supply valve. Spray all the fittings.
Bubbles indicate leaks. Although all gas connections on the ProFire grill are leak tested at the factory
prior to shipment a complete gas tightness check must be performed at the installation site due to possi-
ble mishandling in shipment, or excessive pressure unknowingly being applied to the unit. Periodically
check the whole system for leaks, or immediately check if the smell of gas is detected.
DO NOT SMOKE WHILE LEAK TESTING. EXTINGUISH ALL OPEN FLAMES.
NEVER LEAK TEST WITH AN OPEN FLAME.
Make a soap solution of one part liquid detergent and one part water. You will need a spray bottle, brush,
or rag to apply the solution to the fittings. For L.P. units, check with a full cylinder. The valve panel must
be removed to check the valves and fittings. Remove the knobs. Then remove the screws which fasten
the valve panel to the unit. Pull the valve panel outward and unplug the wires from the back of the rotary
igniter. If your grill has the optional rear broiler, remove the screws which hold the inspection cover in
place.
TO TEST
Make sure all control valves are in the "OFF" position. Turn the gas supply "ON". Check all connec-
tions from the supply line, or L.P. cylinder up to and including the manifold pipe assembly. Apply the
soap solution around all connections, valves, and tubing. Soap bubbles will appear where there is a leak
present. If a leak is present, immediately turn off gas supply, tighten any leaking fittings, turn gas on, and
recheck.
WARNING
IF YOU CANNOT STOP A GAS LEAK TURN OFF THE GAS SUPPLY AND CALL YOUR
LOCAL GAS UTILITY, OR THE DEALER YOU PURCHASED THE APPLIANCE FROM.
Only those parts recommended by the manufacturer should be used on the ProFire gas grill.
Substitutions will void the warranty.
Do not use the ProFire gas grill until all connections have been checked
and do not leak.
11
LEAK TESTING
Each burner is tested and adjusted at the factory prior to shipment. However, variations in the local
gas supply or conversion from one gas to another may make it necessary to adjust the burners. The
flames of the grill burners should be visually checked. The rear broiler (when equipped) should have
a very low flame (no more than 1/4") and glow with a light red color. There is no air shutter adjust-
ment for the rear broiler. On the main burners and side burners the flames should be blue and stable
with small yellow tips and no excessive noise or lifting. If the burners do not operate correctly, check
if the air shutter or burner ports are blocked by dirt, debris, spider webs, etc. and proceed with air
shutter adjustment. The amount of air which is drawn into a burner is governed by a metal cup at the
inlet of the burner called an air shutter. It is locked in place by a screw, which must be loosened prior
to lighting the burner for adjustment. To access the grill burner air shutters, first, remove the valve
panel by removing the screws on the corners of the valve panel. Remove the control knobs. Pull the
valve panel outwards while unplugging the rotary ignitors. With a screwdriver, loosen the screw on
the side of the air shutter. Light the burner and adjust according to the directions below. Access and
adjustment of the side burner air shutters is done in the same manner as the main burners.
BURNER AIR ADJUSTMENT
BE CAREFUL AS THE BURNER MAY BE VERY HOT!
A yellow flame indicates insufficient air: Open the air shutter to allow more air to the burner.
Flame is noisy, blows out, or lifts away from burner or will not light, this indicates too much air:
Close the air shutter. Once the air shutter is adjusted turn the burner off and reverse steps to
reassemble.
12
ADJUSTING FOR PROPER FLAME AND EFFICIENCY
NOTE TO THE INSTALLER: BE SURE ALL ITEMS ON THIS LIST HAVE BEEN
THOROUGHLY COMPLETED AND CHECKED BEFORE OPERATING THE GRILL.
_____ Specified clearances maintained to combustibles.
_____ If grill is installed in an island, ventilation openings are provided in island.
_____ All internal packaging removed.
_____ Knobs turn freely and bezels centered.
_____ Each burner lights satisfactorily, individually or with adjacent burner lit.
_____ Air shutters adjusted.
_____ Adjustable low setting satisfactory.
_____ Drip pan in place properly and sliding freely.
_____ Pressure regulator connected and set for 11.0"W.C. for L.P. gas.
_____ Pressure checked and set at 7.0"W.C. for natural gas.
_____ Manual shut off valve installed and accessible.
_____ Unit tested and free of gas leaks.
_____ User informed of gas supply shut off valve location.
INSTALLER: PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER.
USER: PLEASE RETAIN THESE INSTRUCTIONS IN A SAFE PLACE FOR
FUTURE USE.
Installer Signature____________________________ Date of completion_____________
13
INSTALLATION CHECK LIST
WARNING
Before lighting your grill be sure to read this section carefully.
Turn all knobs to the off position then:
Inspect the gas supply piping or hose prior to turning the gas on. If there is evidence of cuts, wear,
or abrasion, it must be replaced prior to use. The replacement pressure regulators and hose assem-
bly must be the type specified by the manufacturer. Do not use the ProFire gas grill if the odor of
gas is present.
For L.P. gas, the pressure regulator and hose assembly supplied with the unit must be used. Install
the regulator into the tank and check the hose and regulator connections for leakage with a soap
and water solution before operating your ProFire gas grill. Be sure there is gas in the tank.
DANGER: Failure to open the lid while igniting the grill, or not waiting 5 minutes to
allow the gas to clear if the grill does not light, may result in an explosive flare-up
which can cause serious bodily injury or death.
WARMING: WHEN LIGHTING YOUR GRILL ALWAYS KEEP YOUR FACE AND BODY
AS FAR AWAY FROM THE GRILL AS POSSIBLE.
LIGHTING THE GRILL BURNERS
1. Make sure all knobs are in the "OFF" position.
2. OPEN THE LID and/or remove the side burner cover.
3. Open the gas supply shut-off valve.
4. Push in and turn the burner knob to "LIGHT".
5. Push the ignitor button for 4 seconds button. You will hear a snapping sound, indicating
that a spark is being delivered to the burner.
6. If the burner does not light in 4 seconds, turn the knob to "OFF" and wait 5 minutes before
repeating steps 4 and 5.
MATCH LIGHTING INSTRUCTIONS:
If the ignitor will not light the burners, the burners can be lit manually using a lighted long match, or BBQ lighter.
A. Push in and turn the knob to light.
B. Insert a lit match or BBQ lighter thru the cooking grid to the burners below the flavor grid and push-in and turn
knob to “LIGHT”.
14
HOW TO LIGHT YOUR GAS GRILL
7. If grill does not light, turn all knobs to “OFF” and have a qualified service technician check the grill.
8. Turn all knobs to “OFF” and shut off gas supply when not in use.
WARNING: If you smell gas, shutoff the gas supply and immediately check for leaks using the soapy
water technique.
NOTICE: On the initial use light the grill and let it run on “HIGH” for 15-20 minutes to burn off residues from the facto-
ry.
TO PREHEAT GRILL BEFORE COOKING: Open the lid. Light the grill, close the lid and heat on “”HIGH” for 10
minutes.
1. Remove the burner cover and any cooking utensils from the burner grate.
2. Push and turn the burner control knob to the "LIGHT" position and immediately push the ignitor
button (marked side burner) for 4 seconds or until the burner is lit. If the burner does not light in 4
seconds turn the burner control knob to "OFF" and wait at least 5 minutes for the gas to dissipate
before trying to light again.
3. The side burner can also be lit with a long match or match holder if the ignitor fails to light the burn-
er.
4. To light with a match or match holder, hold the lighted match next to the burner ports and turn the
burner control knob to "LIGHT". Remove and extinguish the match quickly when the burner lights.
LIGHTING THE REAR BROILER
DO NOT USE DURING WINDY CONDITIONS
Because of the location of the rear broiler it is easily susceptible to windy conditions.
1. OPEN THE LID. Push and turn the rotisserie burner control knob to "LIGHT".
2. Push the igniter button (marked rotisserie) You will hear a snapping sound indicating that
a spark is being delivered to the burner.
3. If the burner does not light in 4 seconds, turn the knob to "OFF" and wait 5 minutes
before trying to light again.
4. If the ignitor does not light the burner it may be lit with a long stemmed match or match
holder. Hold the match next to the burner then turn burner control knob to "LIGHT".
relighting a hot burner, wait 5 minutes.
15
HOW TO LIGHT YOUR GAS GRILL
DANGER: Failure to open the lid while igniting the grill, or not waiting 5 minutes to allow
the gas to clear if the grill does not light, may result in an explosive flare-up which can
cause serious bodily injury or death.
WARMING: WHEN LIGHTING YOUR GRILL ALWAYS KEEP YOUR FACE AND BODY
AS FAR AWAY FROM THE GRILL AS POSSIBLE.
LIGHTING THE SIDE BURNERS
TO BEGIN:
1. Be sure the drip pan is in place and pushed all the way to the back of the grill.
2. Light the burners using the instructions given.
3. PREHEAT the grill after lighting with burner control knob turned to "HIGH" for 5 minutes.
Keep the lid closed while preheating.
4. Place the food on the grill and cook to the desired doneness. Adjust the heat setting if necessary.
The burner control knob may be set to any position between "HIGH" and "LOW".
5. Turn all knobs of "OFF" and shut off gas supply when you are finished grilling.
6. Clean the cooking grids and drip pan after each use.
Grilling requires high heat for searing and proper browning. Most foods are cooked at the highest heat setting for the
entire cooking time. However, when grilling large pieces of meat or poultry, it may be necessary to turn the heat to a
lower setting after the initial browning, this will cook the food completely through without burning the outside. Foods
cooked for a long time or basted with a sugary marinade may need a lower heat setting near the end of the cooking
time. The doneness of the meat, whether rare, medium, or well done, is affected to a large degree by the thickness of
the cut. Trim any excess fat from the meat before cooking. To prevent steaks or chops from curling during cooking, slit
the fat around the edges at 2-inch intervals. When defrosting meats, it is recommended that it be done overnight in a
refrigerator as opposed to a microwave as the microwave can dry out or even partially cook the meat.
TO AVOID FLARE-UPS CHICKEN SHOULD BE COOKED ON THE MEDIUM OR LOW SETTING
DUAL PURPOSE THERMOMETER
All ProFire grills come equipped with a dual purpose thermometer which may be left in place to read the air tempera-
ture inside of the closed lid or it can be removed and inserted into the meat that you are grilling.
NEVER ALLOW THE AIR TEMPERATURE INSIDE THE GRILL TO GO ABOVE 500°F.
CHART FOR DESIRED DONENESS
Insert thermometer directly into center of meat to check for doneness.
16
USING YOUR PROFIRE GAS GRILL
Safe Minimum Cooking Temperatures
Category Food
Temperature (°F)
Rest Time*
Ground Meats Beef, Pork, Veal, Lamb, 160 None
Meat Mixtures Turkey, Chicken 165 None
Fresh Beef, Veal Steaks, Roast 145 3 Minutes
Lamb Chops 145 3 Minutes
Poultry Chicken & Turkey, Whole 165 None
Poultry Breast, Roasts 165 None
Poultry Thighs, Legs, Wings 165 None
Duck & Goose 165 None
Stuffing (cooked alone or in bird 165 None
Pork & Ham
Fresh Pork
145 3 Minutes
Fresh Ham (raw)
145 3 Minutes
Precooked Ham (to reheat)
140 None
Sausage
Fresh Bratwurst, Italian & Polish
170 None
Eggs & Egg Dishes
Eggs- Cook Until Yolk and Whites Are Firm
None
Egg Dishes
160 None
Seafood Fin Fish 145 (Cook Until Flesh is Opaque and
Separates Easily With a Fork)
Shrimp, Lobster, and Crabs Cook Until Flesh is Pearly and Opaque
Clams, Oysters, and Mussels Cook Until Shells Open During Cooking
Scallops Cook Until Scallops Turn Milky White or
Opaque and Firm
*After you remove meat from the grill, allow it to rest for the specified amount of time.
FLAVOR GRID
An exclusive feature of the ProFire gas grill is its stainless steel flavor grid designed to deflect the grease
from falling into the burners thereby preventing flare-ups and extending the life of the burners. The perfora-
tions in the stainless steel evens out the heat and creates a hot surface for the meat drippings to fall on to.
This action turns the drippings into smoke, which passes over the meat resulting in a delicious "charcoal
flavor".
THE SMOKER BOX
Most ProFire gas grills include a built-in smoker box installed directly onto the flavor grid because we be-
lieve that wood chips enhance the flavor of everything that is grilled. To use the smoker box place a handful
of water soaked wood chips in the box then ignite the burner directly under the box to "HIGH" for 10
minutes. Then reduce the flame to medium or low to keep the chips from burning up too fast.
CAUTION: When adding more chips to the box when the grill is hot, care must be taken to avoid
burns as the cooking grid must be lifted.
COMMERCIAL RANGE TOP BURNERS
Your ProFire gas grill maybe equipped with commercial style burners. Each is rated at 15,000 BTU and has
a spark ignitor for easy lighting. Provided for use with your side burners is a stainless steel cover which dou-
bles as work surface when the burners are not in use. When using the Grill with the side burners covered,
be careful as heat can conduct from the grill and cause the cover to heat up. Always remove the cover be-
fore lighting the side burners.
WARNING: NEVER LIGHT OR USE THE SIDE BURNERS WITH THE COVER IN PLACE.
FLAME HEIGHT
The correct height of the flame depends on the size and material of the utensil being used, the food being
cooked, and how much liquid is in the utensil.
The flame should never extend beyond the bottom of the pan.
REMOVING AND REPLACING THE BATTERY IN THE IGNITORS
1. Unscrew the plastic nut on the front of the ignitor.
2. Insert a AAA battery making sure the + side faces in.
3. Screw the black plastic nut back on.
17
USING YOUR PROFIRE GAS GRILL
18
ROTISSERIE & REAR BROILER
The rear broiler is an infrared type, which provides intense searing radiant heat. Preferred by profes-
sional chefs over other methods, this intense heat is perfect for searing in the natural juices and nutri-
ents found in quality cuts of meats. When lit, the rear broiler will reach cooking temperatures in about
3 minutes. The orange/red glow will even out in about 5 minutes.
The rotisserie motor is equipped with gears capable of turning up to a 12-lb. cut of meat or poultry.
The motor is mounted to a stainless steel bracket, which attaches to the right side of the grill. The
rotisserie motor must be electrically grounded in accordance with local codes or, in the absence of
local codes, with the National Electrical Code, ANSI/NFPA 70-1990. Warning: This appliance is
equipped with a three-prong (grounding) plug for your protection against shock hazard and should be
plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding
prong from this plug.
The skewer for the rotisserie fits into the motor assembly by placing the pointed end into the motor
and the other end on the support at the left side of the grill. With the skewer pushed in as far as possi-
ble into the motor, the grooved skewer bushing should rest on the left side bracket. The removable
handle should only be in place when handling the skewer.
WHEN USING THE SIDE BURNERS
REMOVE THE SKEWER HANDLE TO PREVENT IT FROM GETTING HOT!
To load the skewer begin with the handle in place, and slide one of the meat holders with prongs fac-
ing away from the handle onto the skewer. Push the skewer through the center of the food, then slide
the second meat holder with prongs towards the food onto the skewer. Center the food on the skewer
then push the meat holders firmly into the food. Tighten the wing nuts. It may be necessary to wrap
the food with butchers string (never use nylon or plastic string) to secure any loose portions.
Once the food is secure insert the skewer into the motor. If needed, remove the grill racks. Place a
basting pan under the food. It is normal for the skewer to flex when large cuts of meats are being
cooked. However, the ProFire system will accommodate most cuts of meat without needing to remove
the cooking grids.
NOTE: After the first use of your rear broiler it is likely that the stainless steel above the burner will
darken to a dark blue color. The electric motor should be removed and stored in a dry place when not
in use.
WARNING
DO NOT USE THE REAR BROILER AND THE BOTTOM BURNERS AT THE SAME TIME!
USING YOUR PROFIRE GAS GRILL
STAINLESS STEEL
The ProFire gas grill is made from non-rusting, non-magnetic, type 304 stainless steel. There are
many different stainless steel cleaners available. Always use the mildest cleaning methods first,
scrubbing in the direction of the grain. To touch up noticeable scratches in the stainless steel, sand
lightly with dry 100 grit emery paper or scotch bright pad in the direction of the grain. Specks of
grease can gather on the surfaces of the stainless steel and bake on to the surface giving the appear-
ance of rust. To remove this grease buildup scrub with a strong degreaser in the direction of the
grain. IMPORTANT: Coat the outer surface of your grill with lemon oil or a Stainless Shine product
such as Sheila Shine. WD 40 also works well to coat the outer finish of your grill. Never clean your
grill with soap and water or degreaser without coating the outer surface of your grill when you’re fin-
ished.
COOKING GRIDS
The easiest way to clean the grill is immediately after cooking is completed. Be sure the burners are
turned off and there are no flames before beginning. Wear a barbecue mitt to protect your hand from
the heat. Using a brass bristle barbecue brush, scrub the hot grids. If the grill is allowed to cool be-
fore cleaning, the cleaning process will be more difficult.
SIDE BURNER GRATES
The side burner grates are stainless steel. Do not attempt to clean a hot grate. When the grate cools
it may be wiped with hot, soapy water, then rinsed and wiped dry. Never immerse a hot grate in wa-
ter as the hot steam produced could cause burns.
DRIP TRAY
The drip tray will collect grease from the grill area and spills from the side burners. Do not attempt to
remove or clean until thoroughly cooled. To avoid grease fires or flare-ups, be sure to clean out the
grease often.
GRILL BURNERS
The burners are constructed of stainless steel and should only require minimal maintenance. Howev-
er, they should be checked every 6 months and cleaned if needed.
1. Shut off gas supply and make sure the grill is cool before attempting to check the burners.
2. Remove the cooking grids, then lift out the flavor grid.
3. Remove the mounting screw holding the burner in place then lift the burner up and
forward so that the burner is pulled away from the valve. (See Page 12)
19
CARE AND MAINENANCE
SIDE BURNERS
The side burners are constructed of cast iron with a high heat black coating. Occasional cleaning of
the burner ports will be necessary. (See page 11, 16) The burners can be repainted using high heat
paint. This will seal the cast iron and help prevent rust.
CLEANING THE BURNERS
After removing:
1. Clean the exterior of the burner with a wire brush.
2. Clear any clogged ports with a straightened paper clip.
3. Never use a wooden toothpick as it may break off and clog the port.
4. Shake out any debris through the air shutter.
5. Use a flashlight to inspect the burner inlet to ensure it is not blocked.
6. If an obstruction can be seen, use a straightened metal wire coat-hanger to clean it out.
CLEANING THE ORIFICES
No regular maintenance should be needed for the orifices. They should only be removed if it is deter-
mined that there is a blockage.
FLAVOR GRID
The flavor grid should be cleaned regularly as it has grease and other debris falling directly on to it.
Keeping it clean will greatly reduce flare-ups and grease fires.
TO CLEAN
1. Wait until the entire grill is cool then remove the cooking grids.
2. Lift out the flavor grid and brush it with a steel wire brush until all the carbon
build up and other debris are removed.
It is not necessary to clean the flavor grid with soap and water.
TO REPLACE THE BURNERS
Replace a burner by sliding the end with air shutter over the brass orifice. Then place the burner onto
the mounting bracket and replace the screw. The burners have an offset hole for mounting to the rear
bracket, which will allow the burner to be installed with the crossover holes facing up. Once rein-
stalled, light all of the burners and check for proper flame. (See page 12 Figure 3) Warning: Serious
injury may occur if the orifice is not located properly in the burner.
20
CARE AND MAINTENANCE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

ProFire 27R Owner's manual

Category
Barbecues & grills
Type
Owner's manual

Ask a question and I''ll find the answer in the document