TFA 14.1502 Owner's manual

Category
Alarm clocks
Type
Owner's manual

This manual is also suitable for

1110
Digitales Bratenthermometer
Digital meat thermometer
Thank you for choosing this digital meat thermometer from
TFA.
1.Before you use the instrument
Please be sure to read the operating instructions before
using it for the first time. This information will help you to
familiarise yourself with your new instrument, learn all of
its functions and parts, find out important details for its first
use and how to operate the instrument and get advice in
the event of faults.
Following the instructions for use will prevent damage to
the device and loss of your statutory warranty rights due to
incorrect use.
We are not liable for any damages occurring as a result of
not following these operating instructions.
Please take particular note of the safety advice.
Please retain these instructions for reference!
2. Extent of delivery
Digital meat thermometer
Metal probe with 1 m silicone cable
Battery 1.5 V AAA
Instruction manual
3.Field of operation and all of the benefits of your new
instrument at a glance
For the optimal preparation of meat and poultry by moni-
toring the core temperature
Can be used for the oven or grill, also ideal for cooking at
low temperatures
Different types of meat and doneness pre-programmed:
Beef, pork, chicken, turkey, veal, lamb, ham, duck, ribs,
ground
well-done, medium, medium rare and rare
Individual temperature requirements can be programmed
Three alarm levels for reaching the target temperature
Metal probe with 1 m silicone cable
Measuring range: 0...+100°C (+32...+212 °F), °C/°F switchable
As table-top device with foldable display and magnets
10. Entsorgung
Dieses Produkt wurde unter Verwendung hochwertiger Mate-
rialen und Bestandteile hergestellt, die recycelt und wieder-
verwendet werden können.
Batterien und Akkus dürfen keinesfalls in den
Hausmüll! Als Verbraucher sind Sie gesetzlich ver-
pflichtet, gebrauchte Batterien und Akkus zur
umweltgerechten Entsorgung beim Handel oder
entsprechenden Sammelstellen gemäß nationaler
oder lokaler Bestimmungen abzugeben.
Die Bezeichnungen für enthaltene Schwermetalle
sind: Cd=Cadmium, Hg=Quecksilber, Pb=Blei
Dieses Gerät ist entsprechend der EU-Richtlinie
über die Entsorgung von Elektro- und Elektronik-
Altgeräten (WEEE) gekennzeichnet.
Dieses Produkt darf nicht mit dem Hausmüll ent-
sorgt werden. Der Nutzer ist verpflichtet, das Alt-
gerät zur umweltgerechten Entsorgung bei einer
ausgewiesenen Annahmestelle für die Entsorgung
von Elektro- und Elektronikgeräten abzugeben.
11. Technische Daten
Messbereich: 0 bis +100°C
+32 bis +212°F, °C/°F-umschaltbar
Auflösung: 1°C/1°F
Kabel: ca. 1 m, hitzebeständig bis 220 °C
Spannungsversorgung: 1 x 1,5V AAA Batterie
Gehäusemaße: 120 x 73 x 20 mm
Gewicht: 133,6 g (inkl. Batterie und Fühler)
TFA Dostmann GmbH & Co.KG, Zum Ottersberg 12, D-97877 Wertheim.
Diese Anleitung oder Auszüge daraus dürfen nur mit Zustimmung von TFA Dost-
mann veröffentlicht werden. Die technischen Daten entsprechen dem Stand bei
Drucklegung und können ohne vorherige Benachrichtigung geändert werden.
www.tfa-dostmann.de 03/11
TFA_No. 14.1502_Anleitung 29.03.2011 14:36 Uhr Seite 5
1312
Digital meat thermometer
Digital meat thermometer
5.Elements
A: Display (Fig. 1)
:
A 1: Chosen type of meat
Example: Ground turkey
A 2: Pre-Alarm
(another 10 °C/°F until target temperature is reached)
A 3: Target temperature
A 4: Target temperature is over 10 °C/°F
A 5: Actual core temperature
A 6: Bar chart for doneness
A 7: Indicator for target doneness
B: Buttons (Fig. 2)
:
B 1: ALARM STOP button
B 2: MEMORY button
B 3: MEAT / ALERT / + button
B 4: TASTE / ALERT / - button
B 5: ALERT ON/OFF switch
B 6: POWER ON/OFF button
B 7: ˚C / ˚F switch
B 8: RESET button
C: Housing (Fig. 2)
:
C 1: Battery compartment
C 2: Magnets
C 3: Connector socket for probe
D: Sensor (Fig. 2)
:
D 1: Metal probe
D 2: Silicone cable
D 3: Jack plug
4.For your safety
The product is exclusively intended for the field of opera-
tion described above. The product should only be used as
described within these instructions.
Repairs, modifications or changes to the instrument by the
consumer are prohibited.
The product is not to be used for medical purpose or for
public information, but is determined for home use only.
Caution!
Risk of injury:
Wear heat-resistant protective gloves when you touch the
sensor during or after cooking.
Do not use the instrument in the microwave.
Keep this instrument and the batteries out of reach of chil-
dren.
Batteries must not be thrown in fire, short-circuited, taken
apart or recharged. Danger of explosion!
Batteries contain harmful acids. Low batteries should be
changed soon to avoid the damage resulting from a leaking
battery. Remove the battery if you do not use the instru-
ment for a longer period of time. Wear chemical-resistant
protective gloves and glasses when handling with leaked
batteries.
Important information on product safety!
Do not place the unit near extreme temperatures, vibration
or shock. Only the probe and the cable are heat resistant
until 220 °C. Never place the probe directly over fire.
Do not immerse the cable and the probe into water. Water
can penetrate into the precision sensor and cause malfunc-
tion. Not suitable for dishwasher.
TFA_No. 14.1502_Anleitung 29.03.2011 14:36 Uhr Seite 6
1514
Digital meat thermometer
Digital meat thermometer
Use the magnets to fasten the thermometer in position
near the oven (cable length 1 m) or use it as a table-top
device and fold up the display.
7.2 Measuring procedure
Slide the ALERT ON/OFF switch to the position ON.
The sensor remains in the meat throughout the cooking
process. The current core temperature and the doneness is
shown permanently on the display.
The pre-alarm (every 5 sec.) will sound and PRE-ALERT flashes,
if the core temperature is 10°C/°F away from the required
target.
The alarm tone (4 short alarm sounds subsequently) will sound
and ALERT flashes, when the core temperature is reached.
A constant alarm tone will sound and OVER COOK flashes, if
the core temperature is 10°C/°F over the target.
Press ALARM STOP button to stop the alarm.
Slide the ALERT ON/OFF switch to the position OFF, the
alarm function is deactivated.
Press the POWER ON/OFF button to switch off the instru-
ment.
Temperatures °C/°F
6.Getting started
Pull off the protection foil on the display. Open the battery
compartment at the back of the instrument and insert the
battery (1 x 1.5 V AAA), polarity as illustrated. Close the bat-
tery door.
A short beep will sound and all LCD segments will light up
for a short moment. The unit is now ready to use.
With the °C/°F switch on the side of the instrument you can
toggle between °C or °F as temperature unit.
Plug the connector for the sensor cable into the socket on
the left-hand side of the instrument.
7. Use
7.1 Preparation
Press the POWER ON/OFF button to switch on the instru-
ment.
Press the MEAT/ALERT/+ button to choose the type of meat
and the TASTE/ALERT/- button to choose the doneness
(table). The target temperature will be shown automati-
cally.
If you choose PGM instead of choosing a type of meat,
you can save an individual temperature value here. Press
and hold the MEMORY button. The temperature display
flashes. Set the desired temperature with the
MEAT/ALERT/+ and the TASTE/ALERT/- button. Save the
value with the MEMORY button.
The suggested target temperatures can also be altered in
this way to suit your individual requirements.
Push the sensor at least 2.5 cm into the middle of the thick-
est part of the meat, for poultry between the torso and the
thigh; it should touch neither bones nor cartilage and
should not protrude from the meat. Put the meat into the
oven and set the relevant oven temperature.
Lead the cable outside. It adapts to the oven seal. Take care
of sharp-edged frames and hinges.
Display BEEF PORK CHICK TURKY VEAL
Types Beef Pork Chicken Turkey Veal
of meat
*Doneness
Well done 77/170 77/170 82/180 82/180 77/170
Medium 71/160 71/160
Medium rare 63/145 63/145
Rare 60/140 60/140
* Different levels of doneness available depending on type of meat.
TFA_No. 14.1502_Anleitung 29.03.2011 14:36 Uhr Seite 7
1716
Digital meat thermometer
Digital meat thermometer
8.Care and maintenance
Clean the instrument and the probe with a soft damp cloth.
Do not use solvents or scouring agents. Protect from mois-
ture.
Turn off the instrument after use. Remove the battery if you
do not use the instrument for a longer period of time.
Keep the instrument in a dry place.
8.1 Battery replacement
Replace the battery when the display becomes weak or the
alarm level declines.
Open the battery compartment at the backside of the
instrument and insert a new battery (1 x 1.5 V AAA), polarity
as illustrated. Close the battery door.
9.Malfunction
Problems Troubleshooting
No display Switch on the instrument
Check battery polarity
Change battery
Display “Hi” Temperature at the sensor
> 100°C/212°F
Display “Lo” Temperature at the sensor
< 0°C/32°F
Check the sensor cable
connection
Incorrect display Press RESET button
Change battery
Temperature display Check the position of the sensor
is too high in the meat
Should your device fail to work despite these measures contact
the supplier where you purchased your product.
Display LAMB HAM DUCK RIBS
Types of meat Lamb Ham Duck Ribs
*Doneness
Well done 77/170 71/160 82/180 77/170
Medium 71/160 71/160
Medium rare 63/145 63/145
Rare 60/140 60/140
* Different levels of doneness available depending on type of meat.
Display GROUND GROUND GROUND GROUND
BEEF PORK CHICK TURKY
Types Ground Ground Ground Ground
of meat beef pork chicken turkey
*Doneness
Well done 71/160 71/160 74/165 74/165
* Different levels of doneness available depending on type of meat.
Display GROUND GROUND PGM
VEAL LAMB
Types Ground Ground Individual
of meat veal lamb value
*Doneness
Well done 71/160 71/160 (70/158)
* Different levels of doneness available depending on type of meat.
Attention: GROUND meat
TFA_No. 14.1502_Anleitung 29.03.2011 14:36 Uhr Seite 8
1918
Digital meat thermometer
Thermo-sonde de cuisson digitale
Nous vous remercions d’avoir choisi la thermo-sonde de cuis-
son digitale de chez TFA.
1. Avent d’utiliser l’appareil
Veuillez lire en premier lieu la notice d’utilisation. Vous
apprendrez à vous servir de votre nouvel appareil en toute
confiance, avec la description de toutes les fonctions propo-
sées et les composants impliqués, ainsi que des détails
importants pour commencer à utiliser l’appareil et des
conseils en cas de disfonctionnement.
En respectant ce manuel d’utilisation, vous éviterez d’en-
dommager l’appareil et de perdre vos droits à la garantie
par mauvaise utilisation.
Nous n’assumons aucune responsabilité pour des domma-
ges, qui ont été causés par non- respect de ce manuel d’uti-
lisation.
Suivez bien toutes les consignes de sécurité !
Conservez soigneusement le mode d’emploi!
2. Contenu de la livraison
Thermo-sonde de cuisson digitale
Sonde en métal avec 1 m câble silicone
Pile 1,5 V AAA
Mode d’emploi
3. Aperçu du domaine d’utilisation
et de tous les avantages de votre nouvel appareil
Pour une préparation parfaite de la viande rouge et des
volailles, grâce au contrôle de la température à cœur.
Adapté pour le four ou le grill et idéal pour les cuissons à
faible température
Différentes sortes de viande et de types de cuisson pré-pro-
grammés:
Viande de bœuf, viande de porc, poule, dindon, veau,
agneau, jambon, canard, côte, viande hachée.
Well done (bien cuit), medium (à point), medium rare (sai-
gnant) et rare (bleu)
Températures cibles de cuisson personnalisables
Trois niveaux d’alarme pour atteindre la température cible
Sonde en métal avec 1 m câble silicone
Plage de mesure: 0...+100°C /+32...+212°F, °C/°F-réversible
Appareil de table avec écran pliable et aimants
10. Waste disposal
This product has been manufactured using high-grade mate-
rials and components which can be recycled and reused.
Never dispose empty batteries and rechargeable
batteries in household waste. As a consumer, you
are legally required to take them to your retail
store or to appropriate collection sites according to
national or local regulations to protect the en-
vironment.
The symbols for the heavy metals contained are:
Cd=cadmium, Hg=mercury, Pb=lead
This instrument is labelled in accordance with the
EU Waste Electrical and Electronic Equipment
Directive (WEEE).
Never dispose this instrument in household waste.
The user is obligated to submit old devices for
environmentally-suitable disposal at a designated
collection point for the disposal of electrical and
electronic equipment.
11. Specifications
Measuring range: 0...+100°C,
+32...+212°F, °C/°F-reversible
Resolution: 1°C/1°F
Cable: appr. 1 m, heat resistant up to 220 °C
Power consumption: 1 x 1.5V AAA battery
Housing dimension: 120 x 73 x 20 mm
Weight: 133.6 g (incl. battery and probe)
TFA Dostmann GmbH & Co. KG, Zum Ottersberg 12, D-97877 Wertheim
No part of this manual may be reproduced without written consent of TFA
Dostmann. The specifications of this product may change without prior notice.
www.tfa-dostmann.de
03/11
TFA_No. 14.1502_Anleitung 29.03.2011 14:36 Uhr Seite 9
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27

TFA 14.1502 Owner's manual

Category
Alarm clocks
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document