INSTALLATION STEP 6
Install the Door Control
Locate door control within sight of door, at a minimum
height of 5 feet where small children cannot reach,
away from moving parts of door and door hardware.
If installing into drywall, drill 5/32" holes and use the
anchors provided. For pre-wired installations (as in new
home construction), it may be mounted to a single gang
box (Figure 2).
1.Strip 1/4" of insulation from one end of bell wire and
connect to the two terminal screws on back of door
control by color: white to 2 and white/red to 1.
2. Pry off cover along one side with a screwdriver blade
(Figure 1). Fasten with 6ABx1-1/4" self-threading
screws (standard installation) or 6-32xl" machine
screws (into gang box) as follows:
• Install bottom screw, allowing 1/8" to protrude above
wall surface.
• Position bottom of door control on screw head and
slide down to secure. Adjust screw for snug fit.
• Drill and install top screw with care to avoid cracking
plastic housing. Do not over tighten.
• Insert top tabs and snap on cover.
3. (For standard installation only) Run bell wire up
wall and across ceiling to motor unit. Use insulated
staples to secure wire in several places. Be careful
not to pierce wire with a staple, creating a short or
open circuit.
4. Connect the bell wire to the terminal screws on the
motor unit panel: white to 2; white/red to 1.
5. Position the antenna wire as shown.
6. Use tacks or staples to permanently attach
entrapment warning label to wall near door control,
and manual release/safety reverse test label in a
prominent location on inside of garage door.
DO NOT connect power and operate opener at
this time. The trolley will travel to the full open
position but will not return to the close position
until the sensor beam is connected and properly
aligned.
Toprevent possible SERIOUSINJURYor DEATHfrom
electrocution:
• Be sure power is not connectedBEFOREinstalling door
control.
• ConnectONLYto 24 VOLTlow voltage wires.
Toprevent possible SERIOUSINJURYor DEATHfrom a
closing garage door:
• Install door control within sight of garage door, out of
reachof children at a minimum height of 5 feet, and
awayfrom all moving parts of door.
• NEVERpermit children to operateor play with door
control push buttons or remote control transmitters.
• Activate door ONLYwhen it can be seenclearly, is
properly adjusted, and there are no obstructions to door
travel.
• ALWAYSkeepgaragedoor in sight until completely
closed. NEVERpermit anyoneto cross pathof closing
garagedoor.
I Outside Keylock Accessory Connections
To opener terminal screws: white to 2; white/red to 1
_111_ 'AI_I_I11111/1_,,IIsIclrlelwl,1_>
Control Console (std installation)
lllllllllllllllllllll
6-32 x 1" Screw
Control Console {pre-wired)
HARDWARE SHOWN
ACTUAL SIZE
_ nsulated
Staples
Dr,/Wall Anchors
Figure 1 Figure 2
REMOVE & REPLACE COVER PRE-WIRED
INSTALLATION
To Replace,
Insert Top To Remove
Tabs First _ _' Twist Here
24 Volt
2-Conductor
Bell Wire in
Gang Box
/
Bell
Wire
Opener
Lighted I Bell Wire Terminal Screws
Top Push __
_ Mounting
Hole
Terminal
Screws I_ Light
Bottom
Mounting _ Lock
Hole
(BACK VIEW)
PREMIUM CONTROL CONSOLE
Back Panel
of Opener
18