Fujitsu AOTG34KMTC Installation guide

Type
Installation guide
En-1
1. SAFETY PRECAUTIONS
• Besuretoreadthismanualcarefullybeforeinstallation.
• Thewarningsandprecautionsindicatedinthismanualcontainimportantinformation
pertainingtoyoursafety.Besuretoobservethem.
• Handthismanual,togetherwiththeoperatingmanual,tothecustomer.Requestthe
customertokeepthemonhandforfutureuse,suchasforrelocatingorrepairingthe
unit.
WARNING
Indicatesapotentiallyorimminentlyhazardoussituationwhich,
ifnotavoided,couldresultindeathorseriousinjury.
CAUTION
Indicatesapotentiallyhazardoussituationthatmayresultin
minorormoderateinjuryordamagetoproperty.
WARNING
Toavoidgettinganelectricshock,nevertouchtheelectricalcomponentssoonafterthe
powersupplyhasbeenturnedoff.Afterturningoffthepower,alwayswait10minutesor
morebeforeyoutouchtheelectricalcomponents.
Installationofthisproductmustbedonebyexperiencedservicetechniciansor
professionalinstallersonlyinaccordancewiththismanual.Installationby
non-professionalorimproperinstallationoftheproductmaycauseseriousaccidents
suchasinjury,waterleakage,electricshock,orre.Iftheproductisinstalledin
disregardoftheinstructionsinthismanual,itwillvoidthemanufacturer’swarranty.
Donotturnonthepoweruntilallworkhasbeencompleted.Turningonthepowerbefore
theworkiscompletedcancauseseriousaccidentssuchasanelectricshockorre.
Ifrefrigerantleakswhenyouareworking,ventilatethearea.Iftheleakingrefrigerantis
exposedtoadirectame,itmayproduceatoxicgas.
Installationmustbeperformedinaccordancewithregulations,codes,orstandardsfor
electricalwiringandequipmentineachcountry,region,ortheinstallingplace.
Donotusethisequipmentwithairoranyotherunspeciedrefrigerantintherefrigerant
lines.Excesspressurecancausearupture.
Duringinstallation,makesurethattherefrigerantpipeisattachedrmlybeforeyourun
thecompressor.
Donotoperatethecompressorundertheconditionofrefrigerantpipingnotattached
properlywith3-wayvalveopen.Thismaycauseabnormalpressureintherefrigeration
cyclethatleadstobreakageandeveninjury.
Wheninstallingandrelocatingtheairconditioner,donotmixgasesotherthanthe
speciedrefrigerant(R32)toentertherefrigerantcycle.
Ifairorothergasenterstherefrigerantcycle,thepressureinsidethecyclewillriseto
anabnormallyhighvalueandcausebreakage,injury,etc.
Donotremovetheconnectionpipewhilethecompressorisinoperationwith3-way
valveopen.
Thismaycauseabnormalpressureintherefrigerationcyclethatleadstobreakageand
eveninjury.
Toconnecttheindoorandoutdoorunit,useairconditionerpipingandcablesavailable
locallyasstandardparts.Thismanualdescribesproperconnectionsusingsuch
installationset.
Donotmodifypowercable,useextensioncableorbranchwiring.Improperusemay
causeelectricshockorrebypoorconnection,insufcientinsulationorovercurrent.
Donotpurgetheairwithrefrigerantsbutuseavacuumpumptovacuumtheinstallation.
Thereisnoextrarefrigerantintheoutdoorunitforairpurging.
UseavacuumpumpforR32orR410Aexclusively.
Usingthesamevacuumpumpfordifferentrefrigerantsmaydamagethevacuumpump
ortheunit.
UseacleangaugemanifoldandcharginghoseforR32orR410Aexclusively.
Donotusemeanstoacceleratethedefrostingprocessortoclean,otherthanthose
recommendedbythemanufacturer.
Theapplianceshallbestoredinaroomwithoutcontinuouslyoperatingignitionsources
(forexample:openames,anoperatinggasapplianceoranoperatingelectricheater.
Donotpierceorburn.
Beawarethatrefrigerantsmaynotcontainanodour.
Donotmodifythisunit,suchasopeningaholeinthecabinet.
Duringthepump-downoperation,makesurethatthecompressoristurnedoffbefore
youremovetherefrigerantpiping.
Donotremovetheconnectionpipewhilethecompressorisinoperationwith3-way
valveopen.
Thismaycauseabnormalpressureintherefrigerationcyclethatleadstobreakageand
eveninjury.
Thisapplianceisnotintendedforusebypersons(includingchildren)withreduced
physical,sensoryormentalcapabilities,orlackofexperienceandknowledge,unless
theyhavebeengivensupervisionorinstructionconcerninguseoftheappliancebya
personresponsiblefortheirsafety.Childrenshouldbesupervisedtoensurethatthey
donotplaywiththeappliance.
Contents
1. SAFETYPRECAUTIONS............................................................................................1
2. PRODUCTSPECIFICATION....................................................................................... 4
2.1. Installationtools.................................................................................................4
2.2. Accessories........................................................................................................4
2.3. Piperequirements..............................................................................................4
2.4. Electricalrequirements.......................................................................................5
2.5. Additionalchargeamount..................................................................................5
2.6. Optionalparts.....................................................................................................5
2.7. Operatingrange.................................................................................................5
3. INSTALLATIONWORK............................................................................................... 5
3.1. Installationdimensions.......................................................................................5
3.2. Transportingtheunit..........................................................................................7
3.3. Mountingtheunit................................................................................................7
3.4. Draininstallation.................................................................................................7
3.5. Pipeinstallation..................................................................................................7
3.6. Sealingtest........................................................................................................9
3.7. Vacuumprocessanddryingprocess.................................................................9
3.8. Additionalcharging...........................................................................................10
3.9. Electricalwiring................................................................................................10
4. HOWTOOPERATEDISPLAYUNIT......................................................................... 12
4.1. Displayunitposition.........................................................................................12
4.2. Descriptionofdisplayandbutton.....................................................................12
5. FIELDSETTING........................................................................................................12
5.1. Fieldsettingbuttons.........................................................................................12
5.2. Functionsettings..............................................................................................13
6. EXTERNALINPUTANDOUTPUT............................................................................. 14
6.1. Externalinput...................................................................................................14
6.2. Externaloutput.................................................................................................14
6.3. Connectionmethod..........................................................................................14
7. DEMANDCONTROL.................................................................................................15
8. TESTRUN................................................................................................................. 15
8.1. Pre-testruncheckitems..................................................................................15
8.2. Testoperationmethod.....................................................................................15
8.3. Checklist..........................................................................................................16
9. FINISHING.................................................................................................................16
9.1. Installinginsulation...........................................................................................16
9.2. Fillingwithputty................................................................................................16
10. ERRORCODE...........................................................................................................16
10.1.Errordisplaymode...........................................................................................16
10.2.Errorcodechecktable.....................................................................................17
11. PUMPDOWN............................................................................................................ 18
11.1.Preparationforpumpdown..............................................................................18
11.2.Pumpdownprocedure.....................................................................................18
AIRCONDITIONER
OutdoorUnit
INSTALLATION MANUAL
PARTNo.9379069946-02
Forauthorizedservicepersonnelonly.
R32
R32.
9379069946-02_IM.indd 1 7/8/2019 09:45:08
En-2
2-2.Work
• Priortobeginningworkonsystemscontainingammablerefrigerants,safety
checksarenecessarytoensurethattheriskofignitionisminimised.Forrepairto
therefrigeratingsystem,theprecautionsin2-2to2-8shallbecompliedwithpriorto
conductingworkonthesystem.
• Workshallbeundertakenunderacontrolledproceduresoastominimizetheriskof
aammablegasorvapourbeingpresentwhiletheworkisbeingperformed.
• Allmaintenancestaffandothersworkinginthelocalareashallbeinstructedonthe
natureofworkbeingcarriedout.
• Workinconnedspacesshallbeavoided.
• Theareaaroundtheworkspaceshallbesectionedoff.
• Ensurethattheconditionswithintheareahavebeenmadesafebycontrolofam-
mablematerial.
2-3.Checkingforpresenceofrefrigerant
• Theareashallbecheckedwithanappropriaterefrigerantdetectorpriortoanddur-
ingwork,toensurethetechnicianisawareofpotentiallyammableatmospheres.
• Ensurethattheleakdetectionequipmentbeingusedissuitableforusewitham-
mablerefrigerants,i.e.nonsparking,adequatelysealedorintrinsicallysafe.
2-4.Presenceofreextinguisher
• Ifanyhotworkistobeconductedontherefrigerationequipmentoranyassociated
parts,appropriatereextinguishingequipmentshallbeavailableathand.
• HaveadrypowderorCO
2
reextinguisheradjacenttothechargingarea.
2-5.Noignitionsources
• Nopersoncarryingoutworkinrelationtoarefrigerationsystemwhichinvolves
exposinganypipeworkthatcontainsorhascontainedammablerefrigerantshall
useanysourcesofignitioninsuchamannerthatitmayleadtotheriskofreor
explosion.
• Allpossibleignitionsources,includingcigarettesmoking,shouldbekeptsufciently
farawayfromthesiteofinstallation,repairing,removinganddisposal,duringwhich
ammablerefrigerantcanpossiblybereleasedtothesurroundingspace.
• Priortoworktakingplace,theareaaroundtheequipmentistobesurveyedtomake
surethattherearenoammablehazardsorignitionrisks.“NoSmoking”signsshall
bedisplayed.
2-6.Ventilatedarea
• Ensurethattheareaisintheopenorthatitisadequatelyventilatedbeforebreaking
intothesystemorconductinganyhotwork.
• Adegreeofventilationshallcontinueduringtheperiodthattheworkiscarriedout.
• Theventilationshouldsafelydisperseanyreleasedrefrigerantandpreferablyexpel
itexternallyintotheatmosphere.
2-7.Checkstotherefrigerationequipment
• Whereelectricalcomponentsarebeingchanged,theyshallbetforthepurpose
andtothecorrectspecication.
• Atalltimesthemanufacturer’smaintenanceandserviceguidelinesshallbefol-
lowed.
• Ifindoubtconsultthemanufacturer’stechnicaldepartmentforassistance.
• Thefollowingchecksshallbeappliedtoinstallationsusingammablerefrigerants.
-Thechargesizeisinaccordancewiththeroomsizewithinwhichtherefrigerant
containingpartsareinstalled.
-Theventilationmachineryandoutletsareoperatingadequatelyandarenot
obstructed.
-Ifanindirectrefrigeratingcircuitisbeingused,thesecondarycircuitshallbe
checkedforthepresenceofrefrigerant.
-Markingtotheequipmentcontinuestobevisibleandlegible.Markingsandsigns
thatareillegibleshallbecorrected.
-Refrigerationpipeorcomponentsareinstalledinapositionwheretheyare
unlikelytobeexposedtoanysubstancewhichmaycorroderefrigerantcontain-
ingcomponents,unlessthecomponentsareconstructedofmaterialswhichare
inherentlyresistanttobeingcorrodedoraresuitablyprotectedagainstbeingso
corroded.
2-8.Checkstoelectricaldevices
• Repairandmaintenancetoelectricalcomponentsshallincludeinitialsafetychecks
andcomponentinspectionprocedures.
• Ifafaultexiststhatcouldcompromisesafety,thennoelectricalsupplyshallbecon-
nectedtothecircuituntilitissatisfactorilydealtwith.
• Ifthefaultcannotbecorrectedimmediatelybutitisnecessarytocontinueopera-
tion,anadequatetemporarysolutionshallbeused.
• Thisshallbereportedtotheowneroftheequipmentsoallpartiesareadvised.
• Initialsafetychecksshallinclude.
-Thatcapacitorsaredischarged:thisshallbedoneinasafemannertoavoidpos-
sibilityofsparking.
-Thattherenoliveelectricalcomponentsandwiringareexposedwhilecharging,
recoveringorpurgingthesystem.
-Thatthereiscontinuityofearthbonding.
CAUTION
Fortheairconditionertoworkappropriately,installitaswritteninthismanual.
Thisunitmustbeinstalledbyqualiedpersonnelwithacapacitycerticationofhandling
refrigerantuids.Refertoregulationandlawsinuseoninstallationplace.
Installtheunitbyfollowinglocalcodesandregulationsinforceintheplaceof
installation,andtheinstructionsprovidedbymanufacturer.
Thisunitispartofasetconstitutinganairconditioner.Theunitmustnotbeinstalled
aloneorbeinstalledwithdevicenotauthorizedbythemanufacturer.
Wheninstallingpipesshorterthan5m,soundoftheoutdoorunitmaybetransferredto
theindoorunit,whichmaycauselargeoperatingorabnormalsound.
Alwaysuseaseparatepowersupplylineprotectedbyacircuitbreakeroperatingonall
wireswithadistancebetweencontactof3mmforthisunit.
Toprotectthepersons,earth(ground)theunitcorrectly,andusethepowercable
combinedwithanEarthLeakageCircuitBreaker(ELCB).
Theunitsarenotexplosionproofandthereforeshouldnotbeinstalledinexplosive
atmosphere.
Thisunitcontainsnouser-serviceableparts.Alwaysconsultauthorizedservice
personneltorepairs.
Whenmovingorrelocatingtheairconditioner,consultexperiencedservicetechnicians
fordisconnectionandreinstallationoftheunit.
Childrenshouldbemonitoredtoensuretheydonotplaywiththedevice.
Donottouchthealuminumnsofheatexchangerbuilt-intheindoororoutdoorunitto
avoidpersonalinjurywhenyouinstallormaintaintheunit.
Donotplaceanyotherelectricalproductsorhouseholdbelongingsunderindoorunitor
outdoorunit.Drippingcondensationfromtheunitmightgetthemwet,andmaycause
damageormalfunctionofyourproperty.
Precautions for using R32 refrigerant
Thebasicinstallationworkproceduresarethesameasconventionalrefrigerant(R410A,
R22)models.
However,paycarefulattentiontothefollowingpoints:
WARNING
Sincetheworkingpressureis1.6timeshigherthanthatofrefrigerantR22models,
someofthepipingandinstallationandservicetoolsarespecial.(See“2.1.Installation
tools”.)
Especially,whenreplacingarefrigerantR22modelwithanewrefrigerantR32model,
alwaysreplacetheconventionalpipingandarenutswiththeR32andR410Apiping
andarenutsontheoutdoorunitside.
ForR32andR410A,thesamearenutontheoutdoorunitsideandpipecanbeused.
ModelsthatuserefrigerantR32andR410Ahaveadifferentchargingportthreaddiam-
etertopreventerroneouschargingwithrefrigerantR22andforsafety.Therefore,check
beforehand.[ThechargingportthreaddiameterforR32andR410Ais1/2-20UNF.]
BemorecarefulthanR22sothatforeignmatter(oil,water,etc.)doesnotenterthepiping.
Also,whenstoringthepiping,securelysealtheopeningbypinching,taping,etc.(Han-
dlingofR32issimilartoR410A.)
CAUTION
1.Installation(Space)
• Thattheinstallationofpipe-workshallbekepttoaminimum.
• Thatpipe-workshallbeprotectedfromphysicaldamage.
• Thatcompliancewithnationalgasregulationsshallbeobserved.
• Thatmechanicalconnectionsshallbeaccessibleformaintenancepurposes.
• Incasesthatrequiremechanicalventilation,ventilationopeningsshallbekeptclear
ofobstruction.
• Whendisposingoftheproductisused,bebasedonnationalregulations,properly
processed.
2.Servicing
2-1.Servicepersonnel
• Anypersonwhoisinvolvedwithworkingonorbreakingintoarefrigerantcircuit
shouldholdacurrentvalidcerticatefromanindustry-accreditedassessment
authority,whichauthorizestheircompetencetohandlerefrigerantssafelyinaccord-
ancewithanindustryrecognisedassessmentspecication.
• Servicingshallonlybeperformedasrecommendedbytheequipmentmanufacturer.
Maintenanceandrepairrequiringtheassistanceofotherskilledpersonnelshallbe
carriedoutunderthesupervisionofthepersoncompetentintheuseofammable
refrigerants.
• Servicingshallbeperformedonlyasrecommendedbythemanufacturer.
9379069946-02_IM.indd 2 7/8/2019 09:45:09
En-3
3.Repairstosealedcomponents
• Duringrepairstosealedcomponents,allelectricalsuppliesshallbedisconnected
fromtheequipmentbeingworkeduponpriortoanyremovalofsealedcovers,etc.
• Ifitisabsolutelynecessarytohaveanelectricalsupplytoequipmentduringservic-
ing,thenapermanentlyoperatingformofleakdetectionshallbelocatedatthemost
criticalpointtowarnofapotentiallyhazardoussituation.
• Particularattentionshallbepaidtothefollowingtoensurethatbyworkingonelec-
tricalcomponents,thecasingisnotalteredinsuchawaythatthelevelofprotection
isaffected.
• Thisshallincludedamagetocables,excessivenumberofconnections,terminals
notmadetooriginalspecication,damagetoseals,incorrectttingofglands,etc.
• Ensurethatapparatusismountedsecurely.
• Ensurethatsealsorsealingmaterialshavenotdegradedsuchthattheynolonger
servethepurposeofpreventingtheingressofammableatmospheres.
• Replacementpartsshallbeinaccordancewiththemanufacturer’sspecications.
NOTE:Theuseofsiliconsealantmayinhibittheeffectivenessofsometypesofleak
detectionequipment.
Intrinsicallysafecomponentsdonothavetobeisolatedpriortoworkingon
them.
4.Repairtointrinsicallysafecomponents
• Donotapplyanypermanentinductiveorcapacitanceloadstothecircuitwithout
ensuringthatthiswillnotexceedthepermissiblevoltageandcurrentpermittedfor
theequipmentinuse.
• Intrinsicallysafecomponentsaretheonlytypesthatcanbeworkedonwhilelivein
thepresenceofaammableatmosphere.
• Thetestapparatusshallbeatthecorrectrating.
• Replacecomponentsonlywithpartsspeciedbythemanufacturer.
• Otherpartsmayresultintheignitionofrefrigerantintheatmospherefromaleak.
5.Cabling
• Checkthatcablingwillnotbesubjecttowear,corrosion,excessivepressure,vibra-
tion,sharpedgesoranyotheradverseenvironmentaleffects.
• Thecheckshallalsotakeintoaccounttheeffectsofagingorcontinualvibration
fromsourcessuchascompressorsorfans.
6.Detectionofammablerefrigerants
• Undernocircumstancesshallpotentialsourcesofignitionbeusedinthesearching
forordetectionofrefrigerantleaks.
• Ahalidetorch(oranyotherdetectorusinganakedame)shallnotbeused.
7.Leakdetectionmethods
• Electronicleakdetectorsshallbeusedtodetectammablerefrigerants,butthe
sensitivitymaynotbeadequate,ormayneedre-calibration.(Detectionequipment
shallbecalibratedinarefrigerant-freearea.)
• Ensurethatthedetectorisnotapotentialsourceofignitionandissuitableforthe
refrigerantused.
• LeakdetectionequipmentshallbesetatapercentageoftheLFLoftherefrigerant
andshallbecalibratedtotherefrigerantemployedandtheappropriatepercentage
ofgas(25%maximum)isconrmed.
• Leakdetectionuidsaresuitableforusewithmostrefrigerantsbuttheuseof
detergentscontainingchlorineshallbeavoidedasthechlorinemayreactwiththe
refrigerantandcorrodethecopperpipe-work.
• Ifaleakissuspected,allnakedamesshallberemoved/extinguished.
• Ifaleakageofrefrigerantisfoundwhichrequiresbrazing,alloftherefrigerantshall
berecoveredfromthesystem,orisolated(bymeansofshutoffvalves)inapartof
thesystemremotefromtheleak.
Oxygenfreenitrogen(OFN)shallthenbepurgedthroughthesystembothbefore
andduringthebrazingprocess.
8.Removalandevacuation
• Whenbreakingintotherefrigerantcircuittomakerepairs–orforanyother
purpose–conventionalproceduresshallbeused.
However,itisimportantthatbestpracticeisfollowedsinceammabilityisaconsid-
eration.
Thefollowingprocedureshallbeadheredto:
• removerefrigerant
• purgethecircuitwithinertgas
• evacuate
• purgeagainwithinertgas
• openthecircuitbycuttingorbrazing
• Therefrigerantchargeshallberecoveredintothecorrectrecoverycylinders.
• Thesystemshallbe“ushed”withOFNtorendertheunitsafe.
• Thisprocessmayneedtoberepeatedseveraltimes.
• Compressedairoroxygenshallnotbeusedforthistask.
• FlushingshallbeachievedbybreakingthevacuuminthesystemwithOFNand
continuingtolluntiltheworkingpressureisachieved,thenventingtoatmosphere,
andnallypullingdowntoavacuum.
• Thisprocessshallberepeateduntilnorefrigerantiswithinthesystem.
• WhenthenalOFNchargeisused,thesystemshallbeventeddowntoatmos-
phericpressuretoenableworktotakeplace.
• Thisoperationisabsolutelyvitalifbrazingoperationsonthepipeworkaretotake
place.
• Ensurethattheoutletforthevacuumpumpisnotclosetoanyignitionsourcesand
thereisventilationavailable.
9.Chargingprocedures
• Inadditiontoconventionalchargingprocedures,thefollowingrequirementsshallbe
followed.
-Ensurethatcontaminationofdifferentrefrigerantsdoesnotoccurwhenusing
chargingequipment.
-Hosesorlinesshallbeasshortaspossibletominimizetheamountofrefrigerant
containedinthem.
-Cylindersshallbekeptupright.
-Ensurethattherefrigerationsystemisearthedpriortochargingthesystemwith
refrigerant.
-Labelthesystemwhenchargingiscomplete(ifnotalready).
-Extremecareshallbetakennottooverlltherefrigerationsystem.
• PriortorechargingthesystemitshallbepressuretestedwithOFN.
• Thesystemshallbeleaktestedoncompletionofchargingbutpriortocommission-
ing.
• Afollowupleaktestshallbecarriedoutpriortoleavingthesite.
10.Decommissioning
• Beforecarryingoutthisprocedure,itisessentialthatthetechnicianiscompletely
familiarwiththeequipmentandallitsdetails.
• Itisrecommendedgoodpracticethatallrefrigerantsarerecoveredsafely.
• Priortothetaskbeingcarriedout,anoilandrefrigerantsampleshallbetakenin
caseanalysisisrequiredpriortore-useofreclaimedrefrigerant.
• Itisessentialthatelectricalpowerisavailablebeforethetaskiscommenced.
a)Becomefamiliarwiththeequipmentanditsoperation.
b)Isolatesystemelectrically.
c)Beforeattemptingtheprocedureensurethat:
• mechanicalhandlingequipmentisavailable,ifrequired,forhandlingrefriger-
antcylinders;
• allpersonalprotectiveequipmentisavailableandbeingusedcorrectly;
• therecoveryprocessissupervisedatalltimesbyacompetentperson;
• recoveryequipmentandcylindersconformtotheappropriatestandards.
d)Pumpdownrefrigerantsystem,ifpossible.
e)Ifavacuumisnotpossible,makeamanifoldsothatrefrigerantcanberemoved
fromvariouspartsofthesystem.
f)Makesurethatcylinderissituatedonthescalesbeforerecoverytakesplace.
g)Starttherecoverymachineandoperateinaccordancewithmanufacturer’s
instructions.
h)Donotoverllcylinders.(Nomorethan80%volumeliquidcharge).
i)Donotexceedthemaximumworkingpressureofthecylinder,eventemporarily.
j)Whenthecylindershavebeenlledcorrectlyandtheprocesscompleted,make
surethatthecylindersandtheequipmentareremovedfromsitepromptlyand
allisolationvalvesontheequipmentareclosedoff.
k)Recoveredrefrigerantshallnotbechargedintoanotherrefrigerationsystem
unlessithasbeencleanedandchecked.
11.Labelling
• Equipmentshallbelabelledstatingthatithasbeende-commissionedandemptied
ofrefrigerant.
• Thelabelshallbedatedandsigned.
• Ensurethattherearelabelsontheequipmentstatingtheequipmentcontainsam-
mablerefrigerant.
12.Recovery
• Whenremovingrefrigerantfromasystem,eitherforservicingordecommissioning,
itisrecommendedgoodpracticethatallrefrigerantsareremovedsafely.
• Whentransferringrefrigerantintocylinders,ensurethatonlyappropriaterefrigerant
recoverycylindersareemployed.
• Ensurethatthecorrectnumberofcylindersforholdingthetotalsystemchargeare
available.
• Allcylinderstobeusedaredesignatedfortherecoveredrefrigerantandlabelledfor
thatrefrigerant(i.e.specialcylindersfortherecoveryofrefrigerant).
• Cylindersshallbecompletewithpressurereliefvalveandassociatedshut-offvalves
ingoodworkingorder.
• Emptyrecoverycylindersareevacuatedand,ifpossible,cooledbeforerecovery
occurs.
• Therecoveryequipmentshallbeingoodworkingorderwithasetofinstructions
concerningtheequipmentthatisathandandshallbesuitablefortherecoveryof
ammablerefrigerants.
• Inaddition,asetofcalibratedweighingscalesshallbeavailableandingoodwork-
ingorder.
• Hosesshallbecompletewithleak-freedisconnectcouplingsandingoodcondition.
• Beforeusingtherecoverymachine,checkthatitisinsatisfactoryworkingorder,has
beenproperlymaintainedandthatanyassociatedelectricalcomponentsaresealed
topreventignitionintheeventofarefrigerantrelease.
Consultmanufacturerifindoubt.
• Therecoveredrefrigerantshallbereturnedtotherefrigerantsupplierinthecorrect
recoverycylinder,andtherelevantWasteTransferNotearranged.
• Donotmixrefrigerantsinrecoveryunitsandespeciallynotincylinders.
• Ifcompressorsorcompressoroilsaretoberemoved,ensurethattheyhavebeen
evacuatedtoanacceptableleveltomakecertainthatammablerefrigerantdoes
notremainwithinthelubricant.
• Theevacuationprocessshallbecarriedoutpriortoreturningthecompressortothe
suppliers.
• Onlyelectricheatingtothecompressorbodyshallbeemployedtoacceleratethis
process.
• Whenoilisdrainedfromasystem,itshallbecarriedoutsafely.
9379069946-02_IM.indd 3 7/8/2019 09:45:10
En-4
Explanationofsymbolsdisplayedontheindoorunitoroutdoorunit.
WARNING
Thissymbolshowsthatthisequipmentusesaammable
refrigerant.
Iftherefrigerantisleaked,togetherwithanexternaligni-
tionsource,thereisapossibilityofignition.
CAUTION
ThissymbolshowsthattheOperationManualshouldbe
readcarefully.
CAUTION
Thissymbolshowsthataservicepersonnelshouldbe
handlingthisequipmentwithreferencetotheInstallation
Manual.
CAUTION
Thissymbolshowsthatthereisinformationincludedinthe
OperationManualand/orInstallationManual.
2. PRODUCT SPECIFICATION
2.1. Installation tools
WARNING
ToinstallaunitthatusesR32refrigerant,usededicatedtoolsandpipingmaterialsthat
havebeenmanufacturedspecicallyforR32(R410A)use.BecausethepressureofR32
refrigerantisapproximately1.6timeshigherthanR22,failuretousededicatedpiping
materialorimproperinstallationcancauseruptureorinjury.Furthermore,itcancause
seriousaccidentssuchaswaterleakage,electricshock,orre.
Donotuseavacuumpumporrefrigerantrecoverytoolswithaseriesmotor,sinceit
mayignite.
Tool name Change from R22 to R32(R410A)
Gaugemanifold Pressureishighandcannotbemeasuredwithaconventional
(R22)gauge.Topreventerroneousmixingofotherrefrigerants,
thediameterofeachporthasbeenchanged.
Itisrecommendedthegaugewithseals–0.1to5.3MPa(-1to
53bar)forhighpressure.–0.1to3.8MPa(-1to38bar)forlow
pressure.
Charginghose Toincreasepressureresistance,thehosematerialandbase
sizewerechanged.(R32/R410A)
Vacuumpump Aconventionalvacuumpumpcanbeusedbyinstallinga
vacuumpumpadapter.
(Useofavacuumpumpwithaseriesmotorisprohibited.)
Gasleakagedetector SpecialgasleakagedetectorforHFCrefrigerantR410A.
Copper pipes
Itisnecessarytouseseamlesscopperpipesanditisdesirablethattheamountofresidual
oilislessthan40mg/10m.Donotusecopperpipeshavingacollapsed,deformedor
discoloredportion(especiallyontheinteriorsurface).Otherwise,theexpansionvalveor
capillarytubemaybecomeblockedwithcontaminants.
AsanairconditionerusingR32(R410A)incurspressurehigherthanwhenusing
conventionalrefrigerant,itisnecessarytochooseadequatematerials.
2.2. Accessories
WARNING
Forinstallationpurposes,besuretousethepartssuppliedbythemanufacturerorother
prescribedparts.Theuseofnon-prescribedpartscancauseseriousaccidentssuchas
theunitfalling,waterleakage,electricshock,orre.
Followinginstallationpartsaresupplied.Usethemasrequired.
Keepthismanualinasafeplace,anddonotdiscardanyotheraccessoriesuntilthe
installationworkhasbeencompleted.
Name and shape Q’ty Description
Installation
manual
1
Thismanual
Drainpipe
1
Foroutdoorunitdrainpipingwork
(Maynotbesupplied,dependingon
themodel.)
Draincap
2
One-touchbush
2
Forpowersupplycableand
connectioncableinstallation
PartslistfordemandcontrolPCBkit
Name and shape Q’ty Description
Cabletiewithclips
1
Forxingthesignaltransmission
cable.
Cableties(small)
1
ForxingtheEMIcoreandthesignal
transmissioncable.
EMIcore
1
Attachedtothesignaltransmission
cable.
Insulation
2
ForattachingtheEMIcore.
2.3. Pipe requirements
Selecting the pipe material
CAUTION
Donotuseexistingpipes.
Usepipesthathavecleanexternalandinternalsideswithoutanycontaminationwhich
maycausetroubleduringuse,suchassulfur,oxide,dust,cuttingwaste,oil,orwater.
Itisnecessarytouseseamlesscopperpipes.
Material:Phosphordeoxidizedseamlesscopperpipes.
Itisdesirablethattheamountofresidualoilislessthan40mg/10m.
Donotusecopperpipesthathaveacollapsed,deformed,ordiscoloredportion
(especiallyontheinteriorsurface).Otherwise,theexpansionvalveorcapillarytubemay
becomeblockedwithcontaminants.
Improperpipeselectionwilldegradeperformance.Asanairconditionerusing
R32(R410A)incurspressurehigherthanwhenusingconventionalrefrigerant,itis
necessarytochooseadequatematerials.
NOTE:
ThicknessesofcopperpipesusedwithR32(R410A)areasshowninthetable.
Neverusecopperpipesthinnerthanthoseindicatedinthetableeveniftheyareavailable
onthemarket.
Thicknesses of Annealed Copper Pipes
Pipe outside diameter
[mm (in.)]
Thickness
[mm]
9.52(3/8) 0.8
15.88(5/8) 1.0
Protection of pipes
Protectthepipestopreventtheentryofmoistureanddust.
Especially,payattentionwhenpassingthepipesthroughaholeorconnectingtheendof
apipetotheoutdoorunit.
Location Working period Protection method
Outdoor
1monthormore Pinchpipes
Lessthan1month Pinchortapepipes
Indoor - Pinchortapepipes
Refrigerant pipe size and allowable piping length
CAUTION
Keepthepipinglengthbetweentheindoorunitandoutdoorunitwithintheallowable
tolerance.
Themaximumlengthsofthisproductareshowninthetable.Iftheunitsarefurtherapart
thanthis,correctoperationcannotbeguaranteed.
Pipediameter<Liquid/Gas>[mm(in.)] 9.52(3/8)/15.88(5/8)
Max.pipinglength(L)[m] 75
*1
Max.heightdifference(H)
<Indoorunittooutdoorunit>[m]
30
View(Example)
H
L
*1:Forthestandardpipediameter.
9379069946-02_IM.indd 4 7/8/2019 09:45:16
En-5
2.4. Electrical requirements
CAUTION
Besuretoinstallabreakerwithspeciedcapacity.
Beforetheelectricalworking,conrmelectricalstandardsandregulationsineachcountry,
region,orinstallingplace.Thenselectappropriatecablesandbreakersthatcomplywiththem.
Voltage rating 1Φ240V(50Hz)
Operating range 198to264V
Cable Conductorsize[mm
2
]
*1
Type Remarks
PowerSupplyCable 2.5-4.0 Type60245IEC66
2Cable+Earth(Ground)
1Φ240V
ConnectionCable 1.5-2.5 Type60245IEC57
3Cable+Earth(Ground)
1Φ240V
Demandcontrol
signaltransmission
cable
0.5-1.5 AS/NZS5000.2
Doubleinsulated
(Max.length:30m)
*1
Selectedsample:Selectthecorrectcabletypeandsizeaccordingtothecountryor
region’sregulations.
Max.wirelength:Setalengthsothatthevoltagedropislessthan2%.Increasethewire
diameterwhenthewirelengthislong.
Breaker Specication
*2
Circuitbreaker(overcurrent) Current:20(A)
Earthleakagebreaker Leakagecurrent:30mA0.1secorless
*3
*2
Selecttheappropriatebreakerofthedescribedspecicationaccordingtothenationalor
regionalstandards.
*3
Selectthebreakerthatenoughloadcurrentcanpassthroughit.
• Beforestartingworkcheckthatpowerisnotbeingsuppliedtoallpolesoftheindoor
unitandoutdoorunit.
• Installallelectricalworksinaccordancetostandard.
• Installthedisconnectdevicewithacontactgapofatleast3mminallpolesnearbythe
units.(Bothindoorunitandoutdoorunit)
• Wiringsizemustcomplywiththeapplicablelocalandnationalcode.
•
2.5. Additional charge amount
For Pre-charge lengths
Piping length (L) *Pre-Charge [m]
30
If additional refrigerant is required
• WhenthepipingislongerthanPre-chargelength,additionalchargingisnecessary.
• Fortheadditionalamount,seethetablebelow.
Additional charging amount
Refrigerant pipe size
[mm (in.)]
Piping length (L)*
~30m
40m 50m 60m 70m 75m g/m
Liquid 9.52(3/8)
None 450g 900g 1350g 1800g 2025g 45g/m
Gas 15.88(5/8)
*Referto“Refrigerantpipesizeandallowablepipinglength”.
Maximum amount of refrigerant charge
4025g(2000g+2025g)
2.6. Optional parts
Parts name Model name
Externalconnectkit
(forExternalinput/output)
UTY-XWZXZ3
2.7. Operating range
Coolingmode
Drymode
Heatingmode
[Reversecyclemodelonly]
Outdoor
temperature
-10to46˚C
-15 to 24 ˚C
• Ifthisunitisoperatedoutsidetheoperatingtemperature,theprotectioncircuitsmaybe
activatedtostoptheunit.
3. INSTALLATION WORK
Makesuretoobtainthecustomer’sapprovalforselectingandinstallingtheoutdoorunit.
WARNING
Securelyinstalltheoutdoorunitatalocationthatcanwithstandtheweightoftheunit.
Otherwise,theoutdoorunitmayfallandcauseinjury.
Besuretoinstalltheoutdoorunitasprescribed,sothatitcanwithstandearthquakes
andtyphoonsorotherstrongwinds.Improperinstallationcancausetheunittotoppleor
fall,orotheraccidents.
Donotinstalltheoutdoorunitneartheedgeofabalcony.Otherwise,childrenmayclimb
ontotheoutdoorunitandfalloffofthebalcony.
CAUTION
Donotinstalltheoutdoorunitinthefollowingareas:
• Areawithhighsaltcontent,suchasattheseaside.Itwilldeterioratemetalparts,
causingthepartstofailortheunittoleakwater.
• Arealledwithmineraloilorcontainingalargeamountofsplashedoilorsteam,suchas
akitchen.Itwilldeteriorateplasticparts,causingthepartstofailortheunittoleakwater.
• Areathatgeneratessubstancesthatadverselyaffecttheequipment,suchassulfuric
gas,chlorinegas,acid,oralkali.Itwillcausethecopperpipesandbrazedjointsto
corrode,whichcancauserefrigerantleakage.
• Areacontainingequipmentthatgenerateselectromagneticinterference.Itwillcause
thecontrolsystemtomalfunction,preventingtheunitfromoperatingnormally.
• Areathatcancausecombustiblegastoleak,containssuspendedcarbonbersor
ammabledust,orvolatileinammablessuchaspaintthinnerorgasoline.Ifgas
leaksandsettlesaroundtheunit,itcancauseare.
• Areawheresmallanimalsmaylive.Itmaycausefailure,smokeorreifsmall
animalsenterandtouchinternalelectricalparts.
• Areawhereanimalsmayurinateontheunitorammoniamaybegenerated.
• Areathathasheatsources,vapors,ortheriskofleakageoraccumulationof
ammablegas.
Donottilttheoutdoorunitmorethan3degrees.
Installtheoutdoorunitinawell-ventilatedlocationawayfromrainordirectsunlight.
Iftheoutdoorunitmustbeinstalledinanareawithineasyreachofthegeneralpublic,
installasnecessaryaprotectivefenceortheliketopreventtheiraccess.
Installtheoutdoorunitinalocationthatwouldnotinconvenienceyourneighbors,as
theycouldbeaffectedbytheairowcomingoutfromtheoutlet,noise,orvibration.Ifit
mustbeinstalledinproximitytoyourneighbors,besuretoobtaintheirapproval.
Iftheoutdoorunitisinstalledinacoldregionthatisaffectedbysnowaccumulation,
snowfall,orfreezing,takeappropriatemeasurestoprotectitfromthoseelements.
Toensureastableoperation,installinletandoutletducts.
Installtheoutdoorunitinalocationthatisawayfromexhaustortheventportsthat
dischargevapor,soot,dust,ordebris.
Installtheindoorunit,outdoorunit,powersupplycable,connectioncable,andremote
controlcableatleast1mawayfromatelevisionorradioreceivers.Thepurposeofthis
istopreventTVreceptioninterferenceorradionoise.(Eveniftheyareinstalledmore
than1mapart,youcouldstillreceivenoiseundersomesignalconditions.)
Ifchildrenunder10yearsoldmayapproachtheunit,takepreventivemeasuressothat
theycannotreachtheunit.
Keepthelengthofthepipingoftheindoorandoutdoorunitswithintheallowablerange.
Formaintenancepurposes,donotburythepiping.
3.1. Installation dimensions
CAUTION
Theinstallationspaceshowninthefollowingexamplesisbasedonanambient
temperatureundercoolingoperationof35°C(DB)attheairintakeoftheoutdoorunit.
Providemorespacearoundtheairintakethanshownintheexamplesiftheambient
temperatureexceeds35°C(DB)orifthethermalloadofalloftheoutdoorunitsexceeds
thecapacity.
Considerthetransportationroute,installationspace,maintenancespace,andaccess,
andinstalltheunitinalocationwithsufcientspacefortherefrigerantpiping.
9379069946-02_IM.indd 5 7/8/2019 09:45:17
En-6
CAUTION
Observetheinstallationspacespecicationsthatareshowninthegures.
Providethesamespacefortheairintakeattherearoftheoutdoorunit.
Iftheinstallationisnotperformedaccordingtothespecications,itcouldcauseashort
circuitandresultinalackofoperatingperformance.Asaresult,theoutdoorunitmight
easilybestoppedbyhigh-pressureprotection.
Airintake
Rearview
3.1.1. Outdoor unit installation
When the upper space is open: (Unit:mm)
(1) Obstaclesattherearonly
150ormore
(2) Obstaclesattherearandsides
200
ormore
300
ormore
200
ormore
(3) Obstaclesatthefrontonly
1,000ormore
(4)Obstaclesatthefrontandrear
1,000ormore
150ormore
When an obstruction in the upper space: (Unit:mm)
(1) Obstaclesattherearandabove
300
ormore
Max.500
1,000
ormore
(2)Obstaclesattherear,sides,andabove
1,000
ormore
200
ormore
250
ormore
500
ormore
Max.500
3.1.2. Multiple outdoor unit installation
• Provideatleast250mmofspacebetweentheoutdoorunitsifmultipleunitsare
installed.
• Whenroutingthepipingfromthesideofanoutdoorunit,providespaceforthepiping.
When the upper space is open: (Unit:mm)
(1) Obstaclesattherearonly
300ormore
250ormore
(2)Obstaclesatthefrontonly
1,500ormore
250ormore
(3)Obstaclesatthefrontandrear
500ormore
1,500ormore
250ormore
When an obstruction in the upper space: (Unit:mm)
(1)Obstaclesattherearandabove
• Upto3unitscanbeinstalledsidebyside.
• When4unitsormorearearrangedinaline,providethespaceasshownbelow.
1,500
ormore
500ormore
250ormore
Max.300
1,500
ormore
3.1.3. Outdoor units installation in multi-row (Unit:mm)
(1)Singleparallelunitarrangement
500ormore
600ormore
1,500ormore
3,000ormore
(2)Multipleparallelunitarrangement
500ormore
600ormore
1,500ormore
250ormore
3,500ormore
250ormore
1,500ormore
500ormore
250ormore
CAUTION
Donotinstalltheoutdoorunitintwo-stagewherethedrainwatercouldfreeze.
Otherwisethedrainagefromtheupperunitmayformiceandcauseamalfunctionofthe
lowerunit.
NOTES:
• Ifthespaceislargerthanstatedabove,theconditionwillbethesameaswhenthere
isnoobstacle.
• Heightabovetheoorlevelshouldbe2in(50mm)ormore.
• Wheninstallingtheoutdoorunit,besuretoopenthefrontandleftsidetoobtainbetter
operationefciency.
9379069946-02_IM.indd 6 7/8/2019 09:45:33
En-7
3.2. Transporting the unit
WARNING
Donottouchthens.
Otherwise,personalinjurycouldresult.
CAUTION
Whencarryingtheunit,holdthehandlesontherightandleftsidesandbecareful.
Iftheoutdoorunitiscarriedfromthebottom,handsorngersmaybepinched.
• Besuretoholdthehandlesonthesidesoftheunit.Otherwise,thesuctiongrilleson
thesidesoftheunitmaybedeformed.
Handle
Handle
3.3. Mounting the unit
(Unit:mm)
166
AIR
650
154
50 50
16
410
• Install4anchorboltsatthelocationsindicatedwitharrowsintheabovegure.
• Toreducevibration,donotinstalltheunitdirectlyontheground.Installitonasecure
base(suchasconcreteblocks).
• Thefoundationshallsupportthelegsoftheunitandhaveawidthof50mmormore.
• Dependingontheinstallationconditions,theoutdoorunitmayspreaditsvibration
duringoperation,whichmaycausenoiseandvibration.Therefore,attachdamping
materials(suchasdampingpads)totheoutdoorunitduringinstallation.
• Installthefoundation,makingsurethatthereisenoughspaceforinstallingthe
connectionpipes.
• Securetheunittoasolidblockusingfoundationbolts.(Use4setsofcommercially
availableM10bolts,nuts,andwashers.)
• Theboltsshouldprotrude20mm.
(Refertothegurebelow.)
• Ifoverturningpreventionisrequired,purchasethenecessarycommerciallyavailable
items.
Bolt
20mm
Nut
Base
Fixsecurelywithboltsonasolidblock.(Use4setsofcommerciallyavailableM10bolt,
nutandwasher.)
•Donotinstalldirectlyontheground,thismayresultinequipmentfailure.
•Thedrainwaterisdischargedfromthebottomoftheequipment.Constructadrainditch
aroundthebaseanddischargethedrainwaterproperly.
•Provideamplespaceforicebuildupfromcondensatebetweenthebottomoftheunitand
theflatsurfaceonwhichitismounted.Otherwise,thereisriskthatthedrainagewater
willfreezebetweenthedeviceandthesurface,disablingdrainage.
50mmormore
CAUTION
Iftheunitisinstalledinaregionthatis
exposedtohighwinds,freezingconditions,
freezingrain,snowfallorheavysnow
accumulation,takeappropriatemeasures
toprotectitfromthoseelements.
Toensurestableoperation,theoutdoorunit
mustbeinstalledonaraisedstandorrack,
atorabovetheanticipatedsnowdepthfor
theregion.
Theinstallationofsnowhoodsanddrift
preventionfencingisrecommendedwhen
blowinganddriftingsnowiscommonto
theregion.
3.4. Drain installation
CAUTION
PerformdrainworkinaccordancewiththisManual,andensurethatthedrainwateris
properlydrained.Ifthedrainworkisnotcarriedoutcorrectly,watermaydripdownfrom
theunit,wettingthefurniture.
Whentheoutdoortemperatureis0°Corless,donotusetheaccessorydrainpipe
anddraincap.Ifthedrainpipeanddraincapareused,thedrainwaterinthepipemay
freezeinextremelycoldweather.(Reversecyclemodelonly)
• Ifyouareinstallingthedrainpipe,pleaseprovide
aworkingspaceunderthebaseoftheoutdoorunit.
• Asthedrainwaterowsoutoftheoutdoorunit
duringheatingoperation,installthedrainpipeand
connectittoacommercial16mmhose.(Reverse
cyclemodelonly)
• Wheninstallingthedrainpipe,plugalltheholes
otherthanthedrainpipemountingholeinthe
bottomoftheoutdoorunitwithputtysothereisno
waterleakage.(Reversecyclemodelonly)
(Unit:mm)
341
305
227
438
50
622
Draincapmountinghole×2
Drainpipemounting
hole×1
AIR
3.5. Pipe installation
3.5.1. Opening a knock out hole
CAUTION
Becarefulnottodeformorscratchthepanelwhileopeningtheknockoutholes.
Toprotectthepipinginsulationafteropeningaknockouthole,removeanyburrsfrom
theedgeofthehole.Itisrecommendedtoapplyrustpreventionpainttotheedgeofthe
hole.
• Pipescanbeconnectedfrom4directions,front,lateralside,rearsideandbottom.
(Fig.A)
• Whenconnectingatthebottom,removetheservicecoverandpipingcoveronthe
frontoftheoutdoorunit,andopentheknockoutholeprovidedatthebottomcornerof
thepipingoutlet.
• Itcanbeinstalledasshownon“Fig.B”cuttingoutthe2slitsasindicatedon“Fig.C”.
(Whencuttingslits,useasteelsaw.)
Fig. A
Servicecover
Front
connection
Bottom
connection
Lateral
connection
Rear
connection
Baseoftheoutdoorunit
Drainpipe
Drainpipemountinghole
9379069946-02_IM.indd 7 7/8/2019 09:45:36
En-8
Bending pipes
(1) Whenbendingthepipe,becarefulnottocrushit.
(2) Topreventbreakingofthepipe,avoidsharpbends.
Bendthepipewitharadiusofcurvatureof70mmorover.
(3) Ifthecopperpipeisbendthepipeorpulledtooften,itwillbecomestiff.Do not
bendthepipesmorethanthreetimesatoneplace.
Connection pipes
CAUTION
Besuretoinstallthepipeagainsttheportontheindoorunitandtheoutdoorunit
correctly.Ifthecentringisimproper,thearenutcannotbetightenedsmoothly.Ifthe
arenutisforcedtoturn,thethreadswillbedamaged.
Donotremovethearenutfromtheoutdoorunitpipeuntilimmediatelybefore
connectingtheconnectionpipe.
Afterinstallingthepiping,makesurethattheconnectionpipesdonottouchthe
compressororouterpanel.Ifthepipestouchthecompressororouterpanel,theywill
vibrateandproducenoise.
(1) Servicecoverremoval
• Removethetwomountingscrews.
• Removetheservicecoverbypushingdownwards.
Servicecover
Directionoftheservice
coverremoval
(2) Installtheoutdoorunitwallcap(suppliedwiththeoptionalinstallationsetorprocured
intheeld)tothewallholepipe.
(3) Connecttheoutdoorunitandindoorunitpiping.
(4) Aftermatchingthecentreofthearesurfaceandtighteningthenuthandtight,tighten
thenuttothespeciedtighteningtorquewithatorquewrench.
3-wayvalve(Liquid)
3-wayvalve(Gas)
Flarenut
Connectionpipe
(Liquid)
Flarenut
Connectionpipe
(Gas)
90°
Flarenut
Torque
wrench
Holding
wrench
Torquewrench
Topreventgasleakage,coatthe
aresurfacewithrefrigeratoroil.
Flare nut tightening torque
Flare nut Tightening torque
6.35mm(1/4in.)dia. 16to18N·m(160to180kgf·cm)
9.52mm(3/8in.)dia. 32to42N·m(320to420kgf·cm)
12.70mm(1/2in.)dia. 49to61N·m(490to610kgf·cm)
15.88mm(5/8in.)dia. 63to75N·m(630to750kgf·cm)
Fig. B Fig. C
Bottom
connection
Slit
Slit
3.5.2. Brazing
CAUTION
Ifairoranothertypeofrefrigerantenterstherefrigerationcycle,theinternalpressurein
therefrigerationcyclewillbecomeabnormallyhighandpreventtheunitfromexertingits
fullperformance.
Applynitrogengaswhilebrazingthepipes.Ifapipeisbrazedwithoutapplyingnitrogen
gas,anoxidationlmwillbecreated.
Thiscandegradeperformanceordamagethe
partsintheunit(suchasthecompressoror
valves).
Pressureregulatingvalve
Cap
Brazingarea
Nitrogengas
Nitrogengaspressure:0.02MPa
(=pressurefeltsufcientlyon
thebackofthehand)
Forbrazingmaterial,usephosphorcopperthatdoesnotrequireux.Donotuseuxto
brazepipes.Iftheuxisthechlorinetype,itwillcausethepipestocorrode.
Furthermore,iftheuxcontainsuoride,itwilladverselyaffecttherefrigerantpipe
systemsuchasbydegradingtherefrigerant.
Ifuorideiscontained,qualityofrefrigerantdeterioratesandaffectstherefrigerant
pipingsystem.
Ventilatetheareaappropriatelywhenbrazing,topreventrespread.
Whenbrazing,makesurethatthereisnohazardousorinammableobjectsinthe
surroundingareatoavoidriskofre.
3.5.3. Flare connection (pipe connection)
CAUTION
Donotusemineraloilonaaredpart.Preventmineraloilfromgettingintothesystem
asthiswouldreducethelifetimeoftheunits.
Flaring
(1) Cuttheconnectionpipetothenecessarylengthwithapipecutter.
(2) Holdthe pipe downwardso that cuttings will notenter the pipeand remove the
burrs.
(3) Insertthearenutontothepipeandarethepipewithaaringtool.
Insertthe flare nut(always use theflare nut attachedto the indoor andoutdoor units
respectively)ontothepipeandperformtheareprocessingwithaaretool.
UsethespecialR32(R410A)aretool,ortheconventional(forR22)aretool.
Whenusingtheconventionalaretool,always use an allowance adjustmentgaugeand
securetheAdimensionshowninthefollowingtable.
Checkif[L]isareduniformlyand
isnotcrackedorscratched.
Die
A
Pipe
Pipeoutside
diameter
A(mm)
Flaringtoolfor
R32orR410A,clutchtype
Conventional(R22)Flaringtool
Clutchtype Wingnuttype
ø9.52mm(3/8") 0to0.5 1.0to1.5 1.5to2.0
ø15.88mm(5/8") 0to0.5 1.0to1.5 1.5to2.0
9379069946-02_IM.indd 8 7/8/2019 09:45:39
En-9
Donotremovethecapfromtheconnectionpipebeforeconnectingthepipe.
CAUTION
Fastenaarenutwithatorquewrenchasinstructedinthismanual.Iffastenedtoo
tight,thearenutmaybebrokenafteralongperiodoftimeandcausealeakageof
refrigerant.
Duringinstallation,makesurethattherefrigerantpipeisattachedrmlybeforeyourun
thecompressor.Donotoperatethecompressorundertheconditionofrefrigerantpiping
notattachedproperlywith3-wayvalvesopen.Thismaycauseabnormalpressureinthe
refrigerationcyclethatleadstobreakageandeveninjury.
3.5.4. Handling precautions for the valves
• MountedpartofBlankcapissealedforprotection.
• Fastenblankcaptightlyafteropeningvalves.
Table A
Blank cap
[mm (in.)]
Tightening torque
[N·m (kgf·cm)]
6.35(1/4) 20to25(200to250)
9.52(3/8) 20to25(200to250)
12.70(1/2) 25to30(250to300)
15.88(5/8) 30to35(300to350)
19.05(3/4) 35to40(350to400)
Operating the valves
• Useahexagonwrench(size4mm).
• Opening (1) Insertthehexagonwrenchintothevalveshaft,andturnit
counterclockwise.
(2) Stopturningwhenthevalveshaftcannolongerbeturned.
(Openposition)
• Closing (1) Insertthehexagonwrenchintothevalveshaft,andturnitclockwise.
(2) Stopturningwhenthevalveshaftcannolongerbeturned.
(Closedposition)
Openingdirection
Hexagonwrench
Seal(blankcap
installationportion)
Liquidpipe
Gaspipe
Openingdirection
3.6. Sealing test
WARNING
Beforeoperatingthecompressor,installthepipesandsecurelyconnectthem.
Otherwise,ifthepipesarenotinstalledandifthevalvesareopenwhenthecompressor
operates,aircouldentertherefrigerationcycle.Ifthishappens,thepressureinthe
refrigerationcyclewillbecomeabnormallyhighandcausedamageorinjury.
Aftertheinstallation,makesurethereisnorefrigerantleakage.Iftherefrigerantleaks
intotheroomandbecomesexposedtoasourceofresuchasafanheater,stove,or
burner,itproducesatoxicgas.
Donotsubjectthepipestostrongshocksduringthesealingtest.Itcanrupturethe
pipesandcauseseriousinjury.
CAUTION
Donotblockthewallsandtheceilinguntilthesealingtestandthechargingofthe
refrigerantgashavebeencompleted.
Formaintenancepurposes,donotburythepipingoftheoutdoorunit.
• Afterconnectingthepipes,performasealingtest.
• Makesurethatthe3-wayvalvesareclosedbeforeperformingasealingtest.
• Pressurizenitrogengasto4.15MPatoperformthesealingtest.
• Addnitrogengastoboththeliquidpipesandthegaspipes.
• Checkallareconnectionsandwelds.Then,checkthatthepressurehasnot
decreased.
• Comparethepressuresafterpressurizingandlettingitstandfor24hours,andcheck
thatthepressurehasnotdecreased.
*Whentheoutdoorairtemperaturechanges5°C,thetestpressurechanges
0.05MPa.Ifthepressurehasdropped,thepipejointsmaybeleaking.
• Ifaleakisfound,immediatelyrepairitandperformthesealingtestagain.
• Aftercompletingthesealingtest,releasethenitrogengasfrombothvalves.
• Releasethenitrogengasslowly.
3.7. Vacuum process and drying process
CAUTION
Performarefrigerantleakagetest(airtightnesstest)tocheckforleaksusingnitrogen
gaswhileallvalvesintheoutdoorunitareclosed.(Usethetestpressureindicatedon
thenameplate.)
Besuretoevacuatetherefrigerantsystemusingavacuumpump.
Therefrigerantpressuremaysometimesnotrisewhenaclosedvalveisopenedafter
thesystemisevacuatedusingavacuumpump.Thisiscausedbytheclosureofthe
refrigerantsystemoftheoutdoorunitbytheelectronicexpansionvalve.Thiswillnot
affecttheoperationoftheunit.
Ifthesystemisnotevacuatedsufciently,itsperformancewilldrop.
Useacleangaugemanifoldandcharginghosethatweredesignedspecicallyforuse
withR32(R410A).Usingthesamevacuumequipmentfordifferentrefrigerantsmay
damagethevacuumpumportheunit.
Donotpurgetheairwithrefrigerants,butuseavacuumpumptoevacuatethesystem.
Always use a vacuum pump to purge the air.
Refrigerant for purging the air is not charged in the outdoor unit at the factory.
(1) Checkthatthevalvesareclosedbyremovingtheblankcapsfromthegasandliquid
pipes.
(2) Removethecap,andconnectthegaugemanifold and the vacuum pump to the
chargingvalvebytheservicehoses.
(3) Vacuumtheindoorunitandtheconnectingpipesuntilthepressuregaugeindicates
-0.1MPa(-76cmHg).[Forvacuumgauge:65Pa(500microns)]
(4) When -0.1 MPa (-76 cmHg)[For vacuumgauge: 65 Pa (500 microns)] is reached,
operatethevacuumpumpforatleast60minutes.
(5) Disconnect the servicehoses and tthe cap tothe charging valveto the specied
torque.
(6) Remove theblank caps,andfullyopenthe spindlesof the3-way valveswitha
hexagonwrench[Torque:6~7N·m(60to70kgf·cm)].
(7) Tightentheblankcapsofthe3-wayvalvetothespeciedtorque.
Tightening torque
Blank cap
9.52mm(3/8in.) 20to25N·m(200to250kgf·cm)
15.88mm(5/8in.) 30to35N·m(300to350kgf·cm)
Charging port cap 10to12N·m(100to120kgf·cm)
Servicehose
Servicehosewithvalvecore
Chargingport
Blankcap
Hexagonwrench
Connectingpipe
Gaugemanifold
Vacuumpump
Chargingportcap
3-wayvalve
Usea4mm
hexagon
wrench
CAUTION
Installinsulationaroundboththegasandliquidpipes.Failuretodosomaycausewater
leaks.
Useinsulationwithheatresistanceabove120°C.(Reversecyclemodelonly)
Inaddition,ifthehumiditylevelattheinstallationlocationoftherefrigerantpipingis
expectedtoexceed70%,installinsulationaroundtherefrigerantpiping.Iftheexpected
humiditylevelis70-80%,useinsulationthatis15mmorthicker,andiftheexpected
humiditylevelexceeds80%,useinsulationthatis20mmorthicker.
Ifinsulationisusedthatisnotasthickasspecied,condensationmayformonthe
surfaceoftheinsulation.
Inaddition,useinsulationwithheatconductivityof0.045W/(m·K)orless(at20°C).
9379069946-02_IM.indd 9 7/8/2019 09:45:40
En-10
3.8. Additional charging
WARNING
Whenmovingandinstallingtheairconditioner,donotmixgasotherthanthespecied
refrigerantR32insidetherefrigerantcycle.
Ifairorothergasenterstherefrigerantcycle,thepressureinsidethecyclewillrisetoan
abnormallyhighvalueandcausebreakage,injury,etc.
CAUTION
Aftervacuumingthesystem,addrefrigerant.
Donotreuserecoveredrefrigerant.
WhenchargingtherefrigerantR32,alwaysuseanelectronicscalesforrefrigerant
charging(tomeasuretherefrigerantbyweight).Addingmorerefrigerantthanthe
speciedamountwillcauseamalfunction.
Whenchargingtherefrigerant,takeintoaccounttheslightchangeinthecomposition
ofthegasandliquidphases,andalwayschargefromtheliquidphasesidewhose
compositionisstable.
Checkifthesteelcylinderhasasiphoninstalledornotbeforelling.(Thereisan
indication“withsiphonforllingliquid”onthesteelcylinder.)
Filling method for cylinder with siphon
R32
Gas
Liquid
Setthecylinderverticalandllwiththeliquid.
(Liquidcanbelledwithoutturningbottomupwiththe
siphoninside.)
Filling method for other cylinders
R32
Gas
Liquid
Turnbottomupandllwithliquid.
(Becarefultoavoidturningoverthecylinder.)
BesuretousethespecialtoolsforR32(R410A)forpressureresistanceandtoavoid
mixingofimpuresubstances.
Iftheunitsarefurtherapartthanthemaximumpipelength,correctoperationcannotbe
guaranteed.
Makesuretobackclosingvalveafterrefrigerantcharging.Otherwise,thecompressor
mayfail.
Minimizerefrigerantreleasetotheair.ExcessivereleaseisprohibitedundertheFreon
CollectionandDestructionLaw.
3.9. Electrical wiring
WARNING
Wiringconnectionsmustbeperformedbyaqualiedpersoninaccordancewiththe
specications.Thevoltageratingforthisproductis220-240Vat50Hz.Itshouldbe
operatedwithintherangeof198to264V.
Beforeconnectingthewires,makesurethepowersupplyisOFF.
Useadedicatedpowersupplycircuit.Insufcientpowercapacityintheelectricalcircuit
orimproperwiringmaycauseelectricshockorre.
Installabreakeratthepowersupplyforeachoutdoorunit.Improperbreakerselection
cancauseelectricshockorre.
Installaleakagecircuitbreakerinaccordancewiththerelatedlawsandregulations.An
improperlyinstalledelectricalboxcovercancauseseriousaccidentssuchaselectric
shockorrethroughexposuretodustorwater.
Acircuitbreakerisinstalledinthepermanentwiring.Alwaysuseacircuitthatcantrip
allthepolesofthewiringandhasanisolationdistanceofatleast3mmbetweenthe
contactsofeachpole.
Usedesignatedcablesandpowercables.Improperusemaycauseelectricshockorre
bypoorconnection,insufcientinsulation,orovercurrent.
Donotmodifypowercable,useextensioncableorbranchwiring.Improperusemay
causeelectricshockorrebypoorconnection,insufcientinsulationorovercurrent.
Connecttheconnectorcablesecurelytotheterminal.Checknomechanicalforcebears
onthecablesconnectedtotheterminals.Faultyinstallationcancauseare.
Useringterminalsandtightentheterminalscrewstothespeciedtorques,otherwise,
abnormaloverheatingmaybeproducedandpossiblycauseseriousdamageinsidethe
unit.
Makesuretosecuretheinsulationportionoftheconnectorcablewiththecableclamp.
Damagedinsulationcancauseashortcircuit.
Fixcablessothatcablesdonotmakecontactwiththepipes(especiallyonhigh
pressureside).Donotmakepowersupplycableandtransmissioncablecomein
contactwithvalves(Gas).
Neverinstallapowerfactorimprovementcondenser.Insteadofimprovingthepower
factor,thecondensermayoverheat.
Besuretoperformtheearthing(grounding)work.
Donotconnectearthing(grounding)wirestoagaspipe,waterpipe,lightningrodor
earthing(grounding)wireforatelephone.
• Connectiontoagaspipemaycauseareorexplosionifgasleaks.
• Connectiontoawaterpipeisnotaneffectiveearthing(grounding)methodifPVC
pipeisused.
• Connectiontotheearthing(grounding)wireofatelephoneortoalightningrodmay
causeadangerouslyabnormalriseintheelectricalpotentialiflightningstrikes.
Improperearthing(grounding)workcancauseelectricshocks.
Securelyinstalltheelectricalboxcoverontheunit.Animproperlyinstalledservicecover
cancauseseriousaccidentssuchaselectricshockorrethroughexposuretodustor
water.
CAUTION
Theprimarypowersupplycapacityisfortheairconditioneritself,anddoesnotinclude
theconcurrentuseofotherdevices.
Donotstartoperationuntiltherefrigerantischargedcompletely.Thecompressorwill
failifitisoperatedbeforetherefrigerantpipingchargingiscomplete.
Transmissioncablebetweenindoorunitandoutdoorunitis240V.
Besurenottoremovethermistorsensoretc.frompowerwiringandconnectionwiring.
Compressormayfailifoperatedwhileremoved.
Startwiringworkafterclosingbranchswitchandovercurrentbreaker.
Useanearthleakagebreakerthatiscapableofhandlinghighfrequencies.Becausethe
outdoorunitisinvertercontrolled,ahigh-frequencyearthleakagebreakerisnecessary
topreventamalfunctionofthebreakeritself.
Whenusinganearthleakagebreakerthathasbeendesignedsolelyforearth(ground)
faultprotection,besuretoinstallafuse-equippedswitchorcircuitbreaker.
DonotconnecttheACpowersupplytothetransmissionlineterminalboard.Improper
wiringcandamagetheentiresystem.
Donotusecrossoverpowersupplywiringfortheoutdoorunit.
Ifthetemperaturesurroundingthebreakeristoohigh,theamperageatwhichthe
breakercutsoutmaydecrease.
Becarefulnottogenerateasparkasfollowsforusingaammablerefrigerant.
• Donotremovethefusewhilepowerison.
• Donotdisconnectplugfromthewalloutletandthewiringwhilethepowerison.
• Itisrecommendedtopositiontheoutletconnectioninahighposition.Placethe
cordssothattheydonotgettangled.
Conrmtheindoorunitmodelnamebeforeconnecting.
IftheindoorunitisnotR32compatible,errorsignalwillbedisplayed,andtheunitwillbe
inoperable.
3.9.1. How to connect wiring to the terminal
Cautionwhenwiringcable
Whenstrippingoffthecoatingofaleadwire,alwaysuseaspecialtoolsuchasawire
stripper.Ifthereisnospecialtoolavailable,carefullystripthecoatingwithaknifeetc.
(1) Useringterminalswithinsulatingsleevesasshowninthegurebelowtoconnect
totheterminalblock.
(2) Securelyclamptheringterminalstothewiresusinganappropriatetoolsothatthe
wiresdonotcomeloose.
Sleeve
Strip:10mm
Ringterminal
(3) Usethespeciedwires,connectthemsecurely,andfastenthemsothatthereisno
stressplacedontheterminals.
(4) Useanappropriatescrewdrivertotightentheterminalscrews.Donotusea
screwdriverthatistoosmall,otherwise,thescrewheadsmaybedamagedand
preventthescrewsfrombeingproperlytightened.
(5) Donottightentheterminalscrewstoomuch,otherwise,thescrewsmaybreak.
Wire
Screwwithspecialwasher
Ringterminal
Terminalblocks

Screwwith
specialwasher
Wire
Ringterminal
(6) Seethetablebelowfortheterminalscrewtighteningtorques.
Tightening torque
[N·m (kgf·cm)]
M4screw 1.2to1.8(12to18)
M5screw 2.0to3.0(20to30)
9379069946-02_IM.indd 10 7/8/2019 09:45:41
En-11
3.9.2. Knock out holes for wiring
CAUTION
Becarefulnottodeformorscratchthecoverwhileopeningtheknockoutholes.
Whencablesareroutedfromtheunit,aprotectionsleevefortheconduitscanbe
insertedattheknockouthole.
Ifyoudonotuseawireconduit,besuretoprotectthewirestopreventtheedgeofthe
knockoutholefromcuttingthewires.
Itisrecommendedtoapplyanti-rustpainttotheedgeoftheknockouthole.
Installation method of One-touch bush
PleasextheOne-touchbush(accessory)asshowninthegurebelow.
(Pipecoverrear)
(Pipecoverfront)
One-touchbush
(Accessories)
One-touchbush
(Accessories)
Frontconnection
Lateralconnection
Rearconnection
3.9.3. Wiring method
Connection diagrams
N
L
3
3
2
2
1
1
EARTH
(GROUND)
POWERSUPPLY
Indoorunit
sideterminal
Outdoorunit
sideterminal
(GROUND)
EARTH
EARTH
(GROUND)
Earthing(Grounding)line
Powerline
Controlline
Connection cable preparation
Keeptheearth(ground)wirelongerthantheotherwires.
Earth(Ground)wire
30mm
Powersupplycableor
Transmissioncable
35mmormore
Wiring procedure
(1) •Removethetwomountingscrews.
•Removetheservicecoverbypushingdownwards.
Servicecover
Directionofthe
servicecover
removal
(2) Connectthepowersupplycableandtheconnectioncabletoterminal.
(3) Fastenthepowersupplycableandconnectioncablewithcableclamp.
NL321
Terminalblocks
Firmlysecure
cableclampso
wireterminations
willnotreceive
externalstress.
Usethespecied
wiretypeand
connectitsecurely.
Cableclamp
Cableclamp
Controlbox
Connectioncable
Powersupplycable
Indoor
unit
Terminalblocks
EARTH
(4) Securethecablesusingthecabletieundertheterminalblocks,andthensecurethe
cablesusingthecabletieattachedtothebaseofthevalves.
Cabletie
(5) Puttheservicecoverbackaftercompletionofthework.
Servicecover
Directionofthe
servicecover
removal
9379069946-02_IM.indd 11 7/8/2019 09:45:49
En-12
4. HOW TO OPERATE DISPLAY UNIT
4.1. Display unit position
WARNING
Nevertouchelectricalcomponentssuchastheterminalblocksexceptthebuttonon
thedisplayboard.Itmaycauseaseriousaccidentsuchaselectricshock.
CAUTION
Oncerefrigerantchargingiscompleted,besuretoopenthevalvepriorto
performingtheeldsetting.Otherwise,thecompressormayfail.
Dischargeanystaticelectricityfromyourbodybeforetouchingthepushbuttons.
Nevertouchanyterminalorpatternofanypartsonthecontrolboard.
• Thepositionsofthebuttonsontheoutdoorunitcontrolboardareshowninthegure
below.
• Varioussettingscanbeadjustedbychangingpushbuttonsontheboardoftheoutdoor
unit.
Push
button
s
LEDdisplay
Invertercover
• TheprintedcharactersfortheLEDdisplayareshownbelow.
6:
6:
6: 6: 6:





LEDdisplaypart
Buttonpart
4.2. Description of display and button
Display lamp Function or operation method
(1)POWER/MODE Green
Lightsonwhilepoweron.Fieldsettingin
outdoorunitorerrorcodeisdisplayedwith
blink.
(2)ERROR Red
Blinksduringabnormalairconditioner
operation.
(3)PUMPDOWN
(L1)
Orange Lightsonduringpumpdownoperation.
(4)LOWNOISE
MODE
(L2,L3)
Orange
Lightsonduring“Lownoise”functionwhen
eldsettingisactivated.(LightingpatternofL2
andL3indicateslownoiselevel)
*Referto“5.2.Functionsettings”.
(5)PEAKCUT
(L4,L5,L6)
Orange
Lightsonduring“Peakcut”functionwheneld
settingisactivated.(LightingpatternofL4,L5
andL6indicatespeakcutlevel)
*Referto“5.2.Functionsettings”.
Button Function or operation method
SW1 MODE
Toswitchbetween“Fieldsetting”and“Errorcode
display”.
SW2 SELECT
Toswitchbetweentheindividual“Fieldsetting”and
the“Errorcodedisplays”.
SW3 ENTER
Toxtheindividual“Localsettings”andthe“Error
codedisplays”.
SW4 EXIT Toreturnto“Operationstatusdisplays”.
SW5 PUMPDOWN Tostartthepumpdownoperation.
5. FIELD SETTING
CAUTION
Dischargethestaticelectricityfromyourbodybeforesettinguptheswitches.
Nevertouchtheterminalsorthepatternsonthepartsthataremountedonthe
board.
Wall mounted model cannot use this function.
5.1. Field setting buttons
• Removetheservicecoveroftheoutdoorunitaccesstheprintcircuitboardofthe
displayunit.
Printcircuitboard
button
sforvarioussettingsandLEDdisplaysareshowninthe
gure.
6:
6:
6: 6: 6:





LEDdisplaypart
Buttonpart
9379069946-02_IM.indd 12 7/8/2019 09:45:54
En-13
5.2. Function settings
• Variousfunctionscanbeset.Followthesettingmethoddescribedin5.2.1.tosetaspertherequirement.
Performthesesettingsaftertheindoorunitstops.
Table.SettingsList
No SettingItem
LEDdisplay
Factory
setting
Content
POWER/
MODE
ERROR
PUMP
DOWN
LOWNOISE PEAKCUT
(L1) (L2) (L3) (L4) (L5) (L6)
1
Lownoise
modesetting
Level1
Blink
(9times)
Thenoiselevelwhenoperatinginthelownoise
modecanbeset.Theoperationselectioncan
bedonebyexternalinputterminal(CN10).
Cooling/heatingperformancedecreasesby
loweringoperationnoiselevel.
Level2
Blink
(9times)
2
Peakcut
modesetting
Level1
Blink
(9times)
Thecapacitylimitcanbeselectedwhen
operatingwiththe“PeakCutmode”.
Theoperationselectioncanbedoneby
externalinputterminal(CN11).
Thelowerthelevel,themoretheeffect
ofenergysaving,butthecooling/heating
performancedecreases.
Level2
Blink
(9times)
Level3
Blink
(9times)
Level4
Blink
(9times)
Sign“
”:Lightsoff,“
”:Lightson
5.2.2. Setting for peak cut mode
(1)
Switchto“Fieldsettingmode”bypressing[MODE]button(SW1)for3secondsormore.
(2) Conrm(POWER/MODE)blinks9times,andpress
[
ENTER]button(SW3).
POWER/
MODE
ERROR
PUMP
DOWN
LOW
NOISE
PEAK
CUT
(L1) (L2) (L3) (L4) (L5) (L6)
Blink
(9times)
Sign“
”:Lightsoff,“
”:Lightson,():Numberofblinking
(3) Press
[
SELECT]button(SW2),andadjustLEDlampasshownbelow.(Current
settingisdisplayed)
LOW
NOISE
(L2) (L3)
PEAKCUT
MODE
Blink
Sign“
”:Lightsoff
(4) Press
[
ENTER]button(SW3).
LOW
NOISE
(L2) (L3)
PEAKCUT
MODE
Sign“
”:Lightsoff,“
”:Lightson
(5) Press
[
SELECT]button(SW2),andadjustLEDlampasshowninbelowgure.
PEAK
CUT
(L4) (L5) (L6)
Level1 0%ofratedinputratio
Blink
Level2 50%ofratedinputratio
Blink
Level3 75%ofratedinputratio
Blink Blink
Level4 100%ofratedinputratio Blink
Sign“
”:Lightsoff
(6) Press[ENTER]button(SW3)andxit.
PEAK
CUT
(L4) (L5) (L6)
Level1 0%ofratedinputratio
Level2 50%ofratedinputratio
Level3 75%ofratedinputratio
Level4 100%ofratedinputratio
Sign“
”:Lightsoff,“
”:Lightson
(7) Returnto“Operatingstatusdisplay(normaloperation)”bypressing[EXIT]button
(SW4).
• Whenpressednumberislostduringoperation,restartfromthebeginningofoperation
procedureafterreturningto“Operationstatusdisplay(normaloperation)”bypressing
[EXIT]buttononce.
5.2.1. Setting for low noise mode
(1) Switchto“Fieldsettingmode”bypressing[MODE]button(SW1)for3secondsor
more.
(2) Conrm(POWER/MODE)blinks9times,andpress[ENTER]button(SW3).
POWER/
MODE
ERROR
PUMP
DOWN
LOW
NOISE
PEAK
CUT
(L1) (L2) (L3) (L4) (L5) (L6)
Blink
(9times)
Sign“
”:Lightsoff,“
”:Lightson,():Numberofblinking
(3) Press[SELECT]button(SW2),andadjustLEDdisplayasshownbelow.(Current
settingisdisplayed)
LOW
NOISE
(L2) (L3)
LOWNOISE
MODE
Blink
Sign“
”:Lightsoff
(4) Press[ENTER]button(SW3).
LOW
NOISE
(L2) (L3)
LOWNOISE
MODE
Sign“
”:Lightsoff,“
”:Lightson
(5) Press[SELECT]button(SW2),andadjustLEDlampasshowninbelowgure.
PEAK
CUT
(L4) (L5) (L6)
Level1
Blink
Level2
Blink
Sign“
”:Lightsoff
ThenoiseofLevel2islowerthantheoneofLevel1.
(6) Press[ENTER]button(SW3)andxit.
PEAK
CUT
(L4) (L5) (L6)
Level1
Level2
Sign“
”:Lightsoff,“
”:Lightson
(7)Returnto“Operatingstatusdisplay(normaloperation)”bypressing[EXIT]button
(SW4).
• Incaseofmissinghowmanytimes[SELECT]and[ENTER]buttonsarepressed,
restartfromthebeginningofoperationprocedureafterreturningto“Operationstatus
display(normaloperation)”bypressing[EXIT]buttononce.
9379069946-02_IM.indd 13 7/8/2019 09:45:54
En-14
6. EXTERNAL INPUT AND OUTPUT
Wall mounted model cannot be used this function.
6.1. External input
6.1.1. Wiring of connector
ON/OFFofthe“Lownoisemode”,and“Peakcutmode”functionscanbeenabledwithan
externalelddevice.
Wheninstallingconnectioncable,speciedpart(optionalparts)mustbeused.
Refertosection5.2.Table.SettingsList,fortherequiredfunction.Thefunctionmustbe
setfortheexternalinputtowork.
Input ConnectorNo. Optionalparts
Lownoisemode CN10 Externalconnectkit
Peakcutmode CN11 Externalconnectkit
*MakethedistancefromthePCboardtotheconnectedunitwithin10m(33ft).
Contactcapacity:24VDCormore,10mAormore.
1
2
CN10
1
2
CN11
Circuitdiagramexample
Outdoorunitcontrol
PCboard
Connectedunit
(Fieldsupply)
Ex.)Switch
Connectioncable(option)
Signal
Connector
*10m(33ft)
Low noise mode (CN10)
•Thisfeaturesreducestheoperatingsoundoftheoutdoorunitfromthenormal
sound.Theairconditionerissettothe“Lownoisemode”whenclosingthecontact
inputofacommercialtimerorON/OFFswitchtoaconnectorontheoutdoorcontrol
PCboard.
*Performancemaydropdependingontheoutsideairtemperaturecondition,etc.
*Setthe“Lownoisemode”level,referto“5.2.Functionsettings”.
InputSignal···ON:Lownoisemode
···OFF:Normaloperation
InputSignal
Lownoisemode
ON
ON
OFF
OFF
Peak cut mode (CN11)
•Operationthatsuppressedthecurrentvaluecanbeperformedbymeansofthe
connectedunit.TheairconditionerissettothePeakcutmodebyapplyingthe
contactinputofacommercialON/OFFswitchtoaconnectorontheoutdoorcontrol
PCboard.
*Setthe“Peakcutmode”level,referto“5.2.Functionsettings”.
InputSignal···ON:Peakcutmode
···OFF:Normaloperation
InputSignal
Peakcutmode
ON
ON
OFF
OFF
6.2. External output
6.2.1. Wiring of connector
Wheninstallingconnectioncable,speciedpart(optionalparts)mustbeused.
Output ConnectorNo. Optionalparts
Errorstatus CN12 Externalconnectkit
Compressorstatus CN13 Externalconnectkit
*MakethedistancefromthePCboardtotheconnectedunitwithin10m(33ft).
1)Powersupply
•Voltage(Chartsign=Vcc):DC24Vorless
2)Load
•Load:DC500mAorless
1
2
Vcc
+
+
-
Vcc
1
2
CN12
CN13
Circuitdiagramexample
Outdoorunitcontrol
PCboard
Connectedunit
(Fieldsupply)
Connection
cable(option)
Signal
*10m(33ft)
Connector
Load
Power
supply
Error status output (CN12)
Anairconditionererrorstatussignalisproducedwhenamalfunctionoccurs.
Errorstatus
Outputsignal
Error
ON
Normal
OFF
Compressor status output (CN13)
Compressoroperationstatussignalisproducedwhenthecompressorisrunning.
Compressorstatus
Outputsignal
Operation
ON
Stop
OFF
6.3. Connection method
CAUTION
Donotroutetheconnectioncableoverlappingwiththepowersupplycable.
RemovetheInvertercoverbeforework.
CN13(Blue)
CN12(Black)
CN10(Yellow)
CN11(Green)
Fixtheconnectioncablewithotherwires.
Lettheconnectioncablepassintheknockouthole.
Toprotectthewiringafteropeningaknockouthole,
removeanyburrsfromedgeofthehole.
BesuretoinstalltheInvertercoverafterthewiring
complete.
9379069946-02_IM.indd 14 7/8/2019 09:45:57
En-15
7. DEMAND CONTROL
WARNING
• DonotturnONthepoweruntilallworkhasbeencompleted.TurningONthepower
beforetheworkiscompletedcancauseseriousaccidentssuchaselectricshockor
re.
• Ensurethatanyelectricalinstallationiscompletedbyaqualiedperson.
• EnsuretheelectricalinstallationisinstalledinaccordancewithAS/NZS3000.
(1)Removetheservicecoveroftheoutdoor
unit.
(2)Removetheinvertercoverofthemain
unitboard.
Invertercover
Servicecover
CAUTION
DonotdirectlypressorapplyanypressuretothedemandcontrolPCB.
Applicationofpressuremaycausedamageorfaultoftheboard.
(4)FixtheEMIcoretothesignal
transmissioncablewiththecabletie
(small).
(5)AttachtheInsulationtotheEMI
core.
(6)Fixthesignaltransmissioncable
withthecableclip.
Donotroutethesignaltransmission
cableoverlappingwiththepower
supplycable.Thenwirethecableto
theoutsideoftheoutdoorunit.
(7)Afteryoucompletethewiring,
reinstalltheprotectivecoverandthe
servicecoverrmly.
(3)Connectthesignaltransmissioncable(eld-supplied)
tothedemandcontrolsignalterminalblock.
NOTE:Conrmthateachwiresofthesignaltransmission
cablearermlyconnectedtocorresponding
terminaloftheterminalblock.
1 2 3 C
1:DRM1
2:DRM2
3:DRM3
C:COMMON
20
15
(mm)
Signaltransmissioncable
Attachtheone-touchbushtothe
knockouthole.
㻝㻞㻟㻯
30-35
(mm)
Cabletie
(small)
CAUTION
Routethesignaltransmissioncableawayfromthepowersupplycable.
Adjacentwiringofthosecablesmayleadtheproductmalfunctionscausedbygenerated
noise.
• Whentestingtheoperationofthedemandcontrolmodes,pleaseensuretheair
conditioneranddemandcontrolPCBhasbeeninstalledinaccordancewiththe
providedinstallationmanuals.
• EnquirieswhentestingtheoperationofthedemandcontrolPCB,ConsultFujitsu
CustomerServiceandyourenergyproviderifyouhaveanyoperationalissuesor
errorsarecaused.
8. TEST RUN
8.1. Pre-test run check items
Beforethetestoperation,refertothegureandcheckthefollowingitems.
Istheoutdoorunitsecurelyinstalled?
Haveyouperformedgasleakageinspection?
(Connectionjointsofvariouspipes(angeconnection,brazing))
Istheheatinsulationdonecompletely?
(Gaspipe,liquidpipe,drainhoseextensiononindoorunitside,etc.)
Isthewaterdischargingfromdrainwithoutanyproblems?
Arethecablesconnectedcorrectly?
Arethecablesasperspecications?
Istheearthwireconnectedaccurately?
Arethereanyobstaclesblockingthesuctiongate,andoutletof
theindoor/outdoorunits?
Haveyoulledthespeciedamountofrefrigerant?
Arethestopvalvesofgaspipeandliquidpipefullyopen?
Hasthepowerbeensuppliedtocrankcaseheaterformorethan6hours?
Aftercheckingthattheaboveitemsareallinorder,refer
to“8.2.Testoperationmethod”totestoperationtheunit.
Ifthereareproblems,adjustimmediatelyandrecheck.
8.2. Test operation method
Besuretoconguretestrunsettingsonlywhentheoutdoorunithasstopped
operating.
Testoperationsettingmethod(Itcanbeperformedinthefollowingtwoways)
• Setwithtestoperationsetting(refertoinstallationinstructionsmanualofindoorunit
forfurtherdetails)availableintheremotecontroller.
• “CoolingOperation”and“HeatingOperation”canbeset,using[SELECT]buttonand
[ENTER]buttonavailableontheboardofdisplayunit.
(*Makesuretoperformthersttestoperationwithcoolingoperation.)
Setaspertheproceduregivenbelow.
6:
6:
6: 6: 6:





LEDdisplaypart
Buttonpart
• Dependingonthecommunicationstatusbetweentheindoorandoutdoorunits,
itmaytakeseveralminutesforthesystemtostartoperatingaftersettingsforthe
testrunarecomplete.
• Afterthetestrunsettingsarecomplete,theoutdoorunitsandtheconnected
indoorunitswillstartoperating.Roomtemperaturecontrolwillnotactivateduring
testoperation(continuousoperation).
• Ifaknockingsoundcanbeheardintheliquidcompressionofthecompressor,
stoptheunitimmediatelyandthenenergizethecrankcaseheaterforasufcient
lengthoftimebeforerestartingtheoperation.
9379069946-02_IM.indd 15 7/8/2019 09:45:59
En-16
Setting method on outdoor unit board
(1) Turnonthepoweroftheoutdoorunitandenterstandbymode.
“POWER/MODE”Lamplightsup.
POWER/
MODE
ERROR
PUMP
DOWN
LOW
NOISE
PEAK
CUT
(L1) (L2) (L3) (L4) (L5) (L6)
Sign“
”:Lightsoff,“
”:Lightson
(2) Press[ENTER]buttonformorethan3seconds.
POWER/
MODE
ERROR
PUMP
DOWN
LOW
NOISE
PEAK
CUT
(L1) (L2) (L3) (L4) (L5) (L6)
Blink
Blink
Sign“
”:Lightsoff,“
”:Lightson
(3) Press[SELECT]button,LEDofthetestrunmodeswitchedbetween“COOL”and
“HEAT”.
Coolingtestmode
POWER/
MODE
ERROR
PUMP
DOWN
LOW
NOISE
PEAK
CUT
(L1) (L2) (L3) (L4) (L5) (L6)
Blink
Blink
Sign“
”:Lightsoff,“
”:Lightson
Heatingtestmode
POWER/
MODE
ERROR
PUMP
DOWN
LOW
NOISE
PEAK
CUT
(L1) (L2) (L3) (L4) (L5) (L6)
Blink
Blink
Sign“
”:Lightsoff,“
”:Lightson
(4) Afterconrmingtheoperationmode,press[ENTER]button.
Thedisplaychangesasfollows,andairconditionerstartsoperation.
Coolingtestmode
POWER/
MODE
ERROR
PUMP
DOWN
LOW
NOISE
PEAK
CUT
(L1) (L2) (L3) (L4) (L5) (L6)
Blink
Sign“
”:Lightsoff,“
”:Lightson
Heatingtestmode
POWER/
MODE
ERROR
PUMP
DOWN
LOW
NOISE
PEAK
CUT
(L1) (L2) (L3) (L4) (L5) (L6)
Blink
Sign“
”:Lightsoff,“
”:Lightson
(5) Press[ENTER]button.
Airconditionerstoppedoperation.
POWER/
MODE
ERROR
PUMP
DOWN
LOW
NOISE
PEAK
CUT
(L1) (L2) (L3) (L4) (L5) (L6)
Sign“
”:Lightsoff,“
”:Lightson
8.3. Check list
Checkitemsduringtestoperation.
Istheoutdoorunitmakinganyabnormalnoiseorvibratingsignicantly?
Isthecoldairorhotairblowingfromindoorunitaccordingtotheoperation
mode?
Checkthatthe“ERROR”LEDblinks.
Ifithasdisplayed,checktheerrorcontentasper10.2.describedlater.
Operatetheunitaccordingtotheoperatingmanualprovidedwiththeindoor
unit,andcheckthatitisoperatingnormally.
9. FINISHING
WARNING
Installtheinsulatedpipessothattheydonottouchthecompressor.
9.1. Installing insulation
• DeterminethethicknessoftheinsulationmaterialbyreferringtoTableA.
Table A, Selection of insulation
(for using an insulation material with equal heat transmission rate or below
0.040 W/(m·k))
Relative humidity
[mm (in.)]
Insulation material
Minimum thickness [mm]
70%
or more
75%
or more
80%
or more
85%
or more
Pipe
diameter
9.52(3/8) 9 11 14 18
15.88(5/8) 10 12 16 20
Iftheambienttemperatureandrelativehumidityexceed32°C,increasethelevelofheat
insulationfortherefrigerantpipes.
9.2. Filling with putty
WARNING
Fillthepipingholesandwiringholeswithputty(suppliedlocally)toavoidanygap
(FigA).Ifsmallanimalssuchasinsectsentertheexternalunit,ashortcircuitmaybe
causednearelectricalcomponentsintheservicecover.
• Iftheoutdoorunitisinstalledatalevelthatishigherthantheindoorunit,thewater
thathascondensedinthe3-wayvalveoftheoutdoorunitcouldtraveltotheindoor
unit.Therefore,useputtyinthespacebetweenthepipeandtheinsulationtoprevent
theentryofwatertotheindoorunits.
Fig.A
Putty
Insulation
10. ERROR CODE
YoucandeterminetheoperatingstatusbythelightingupandblinkingoftheLEDlamp.
6:
6:
6: 6: 6:





LEDdisplaypart
Buttonpart
10.1. Error display mode
Displaywhenanerroroccurs.
POWER/
MODE
ERROR
PUMP
DOWN
LOW
NOISE
PEAK
CUT
(L1) (L2) (L3) (L4) (L5) (L6)
Blink
(Hispeed)
Sign“
”:Lightsoff,“
”:Lightson
(1) Checkthatthe“ERROR”LEDblinks,thenpress[ENTER]buttononce.
(2) Fordetails,refertothefollowingtable.
9379069946-02_IM.indd 16 7/8/2019 09:46:00
En-17
10.2. Error code check table
LEDdisplay
DESCRIPTION REMARK
POWER/
MODE
ERROR
PUMP
DOWN
LOWNOISE PEAKCUT
(L1) (L2) (L3) (L4) (L5) (L6)
(2)
(1) (1)
Serialcommunicationerror
Serialforwardtransmissionerrorimmediatelyafter
operation
(2)
(1) (1)
Serialforwardtransmissionerrorduringoperation
(2)
(2) (2)
Indoorunitcapacityerror Indoorunitcapacityerror
(2)
(2) (3)
Combinationerror Differenttypeofrefrigerant
(2)
(5) (15)
Indooruniterror Indooruniterror
(2)
(6) (2)
OutdoorunitmainPCBerror OutdoorunitPCBmodelinformationerror
(2)
(6) (3)
InverterPCBerror Invertererror
(2)
(6) (5)
IPMerror TripterminalLerror
(2)
(7) (1)
Dischargetemp.sensorerror Dischargetemp.sensor1error
(2)
(7) (2)
Compressortemp.sensorerror Compressortemp.sensor1error
(2)
(7) (3)
OutdoorunitHeatEx.sensorerror
HeatEx.middletemp.sensorerror
(2)
(7) (3)
OutdoorunitHeatEx.liquidtemp.sensorerror
(2)
(7) (4)
Outdoortemp.sensorerror Outdoortemp.sensorerror
(2)
(7) (7)
Heatsinktemp.sensorerror Heatsinktemp.sensorerror
(2)
(8) (4)
Currentsensorerror Currentsensor1error(stoppagepermanently)
(2)
(8) (6)
Pressuresensorerror
Highpressureswitch1error
(2)
(8) (6)
Pressuresensorerror
(2)
(9) (4)
Tripdetection Tripdetection
(2)
(9) (5)
Compressormotorcontrolerror Rotorpositiondetectionerror(stoppagepermanently)
(2)
(9) (7)
Outdoorunitfanmotor1error Dutyerror
(2)
(9) (8)
Outdoorunitfanmotor2error Dutyerror
(2)
(9) (9)
4-wayvalveerror 4-wayvalveerror
(2)
(10) (1)
Dischargetemp.1error Dischargetemp.1error
(2)
(10) (3)
Compressortemp.error Compressor1temp.error
(2)
(10) (5)
Pressureerror2 Lowpressureerror
Displaymode
:Lightson
:Lightsoff
:Blink(0.5sLightson/0.5sLightsoff)
():Numberofashing
9379069946-02_IM.indd 17 7/8/2019 09:46:01
En-18
11. PUMP DOWN
WARNING
Nevertouchelectricalcomponentssuchastheterminalblocksexceptthebuttonon
thedisplayboard.Itmaycauseaseriousaccidentsuchaselectricshock.
Duringthepump-downoperation,makesurethatthecompressoristurnedoff
beforeyouremovetherefrigerantpiping.
Donotremovetheconnectionpipewhilethecompressorisinoperationwith3-way
valveopen.Thismaycauseabnormalpressureintherefrigerationcyclethatleads
tobreakageandeveninjury.
CAUTION
Performthepumpdownoperationbeforedisconnectinganyrefrigerantpipeor
electriccable.
Collectrefrigerantfromtheserviceportorthe3-wayvalveifpumpdowncannotbe
performed.
Incaseofgroupcontrolsysteminstallation,disconnectallremotecontrollercables
beforestartingthepumpdownoperation.
(Groupcontrolsysteminstallationisdescribedin“SPECIALINSTALLATION
METHODS”intheinstallationmanualoftheindoorunit.)
Pleasechecktherefrigerantcircuitforanyleaksbeforestartingthepumpdown
operation.
Donotproceedwiththepumpdownoperationifthereisnorefrigerantleftinthe
circuitduetobentorbrokenpiping.
• Operate[PUMPDOWN]buttononthedisplayboardinthemannerdescribed
below.
6:
6:
6: 6: 6:





LEDdisplaypart
Buttonpart
11.1. Preparation for pump down
• Conrmthatthepowerisoff,andthenopentheservicecover.
11.2. Pump down procedure
(1) Checkthe3-wayvalves(boththeliquidsideandgasside)areopened.
(2) Turnthepoweron.
POWER/
MODE
ERROR
PUMP
DOWN
LOW
NOISE
PEAK
CUT
(L1) (L2) (L3) (L4) (L5) (L6)
Sign“
”:Lightsoff,“
”:Lightson
(3) Press[PUMPDOWN]buttonfor3secondsormoreafter3minutesafterpoweron.
POWER/
MODE
ERROR
PUMP
DOWN
LOW
NOISE
PEAK
CUT
(L1) (L2) (L3) (L4) (L5) (L6)
Sign“
”:Lightsoff,“
”:Lightson
LEDdisplaylightsonasshownintheabovegure,andthefansandthe
compressorstartoperating.
• If[PUMPDOWN]buttonispressedwhilethecompressorisoperating,the
compressorwillstop,thenstartagaininabout3minutes.
(4) LEDdisplaywillchangeasshownbelowabout3minutesafterthecompressor
starts.Fullyclosethe3-wayvalveontheliquidpipesideatthisstage.
POWER/
MODE
ERROR
PUMP
DOWN
LOW
NOISE
PEAK
CUT
(L1) (L2) (L3) (L4) (L5) (L6)
Sign“
”:Lightsoff,“
”:Lightson
• Ifthevalveontheliquidpipesideisnotclosed,thepumpdowncannotbe
performed.
(5) WhenLEDdisplaychangesasshowninthebelowgure,closethe3-wayvalveon
thegaspipesidetightly.
POWER/
MODE
ERROR
PUMP
DOWN
LOW
NOISE
PEAK
CUT
(L1) (L2) (L3) (L4) (L5) (L6)
Sign“
”:Lightsoff,“
”:Lightson
• Ifthevalveonthegaspipesideisnotclosed,refrigerantmayowintothepiping
afterthecompressorstops.
Step(5)
Closingdirection
Step(4)
Hexagonwrench
Liquidpipe
Gaspipe
Closingdirection
(6) LEDdisplaychangesafter1minuteasshowninthegurebelow.
POWER/
MODE
ERROR
PUMP
DOWN
LOW
NOISE
PEAK
CUT
(L1) (L2) (L3) (L4) (L5) (L6)
Sign“
”:Lightsoff,“
”:Lightson
Fansandcompressorstopautomatically.
• Ifthepumpdownissuccessfullycompleted(theaboveLEDdisplayisshown),the
outdoorunitremainsstoppeduntilthepoweristurnedoff.
(7) Turnthepoweroff.
POWER/
MODE
ERROR
PUMP
DOWN
LOW
NOISE
PEAK
CUT
(L1) (L2) (L3) (L4) (L5) (L6)
Sign“
”:Lightsoff
PUMPDOWNiscompleted.
NOTES:
• Tostoppumpdown,press[PUMPDOWN]buttonagain.
• Tostartthepumpdownagainafterthecompressorisautomaticallystoppedduetoan
error,turnthepoweroffandopenthe3-wayvalves.Wait3minutes,turnthepoweron
andstartthepumpdownagain.
• Whenstartingtheoperationaftercompletionofthepumpdown,turnthepoweroff,
andthenopenthe3-wayvalves.Wait3minutes,turnthepoweronandperformatest
runinthe“COOL”operationmode.
• Ifanerroroccurs,recovertherefrigerantfromserviceport.
9379069946-02_IM.indd 18 7/8/2019 09:46:01
9379069946-02_IM.indd 19 7/8/2019 09:46:02
9379069946-02_IM.indd 20 7/8/2019 09:46:02
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20