Standard Horizon Wiring Lowrance HDS5 & 7 Owner's manual

Type
Owner's manual
STANDARD HORIZON 10900 Walker Street, Cypress CA 90630
www.standardhorizon.com [email protected] (800)767-2450
The MATRIX AIS can be connected to a HDS5 and 7 chart plotter, however a NMEA multiplexer is needed as the Lowrance has only one
NMEA port. Brookhouse, a company in New Zealand has designed a multiplexer (model AISC) that will work with the Lowrance chart
Plotters. The diagram below shows how to connect the multiplexer between the Lowrance chart plotter and the MATRIX AIS VHF radio.
After connections are made the Lowrance chart plotter, the communications port must be configured to 38400 baud. Refer to the
Lowrance owners manual for operation.
NMEA 0183 Combiner/
Multiplexer 4-channel
Pwr
AIS
38400bps
Yellow C-series NMEA Out+
Stat
(ST Shld-)
(ST Red+)
(ST Yellow sign.)
NMEA Ch1 In
NMEA Ch2 In
NMEA Ch3 In
NMEA Ch4 In
DC 12V
-
+
S
A
A
A
A
R
B
B
B
B
B
A
T
C
C-series NMEA Out -
C-series NMEA In –
C-series NMEA In +
www.brookhouseonline.com
TxD
Brown
Green
WhiteWhite
Bookhouse
Green
Brown
Orange
Green
Yellow
Blue
Gray
Lowrance
HDS5 & 7
MATRIX AIS
Blue
www.brookhouseonline.com/nmeamux_aisc.htm