J
J
u
u
n
n
i
i
p
p
e
e
r
r
N
N
e
e
t
t
w
w
o
o
r
r
k
k
s
s
N
N
e
e
t
t
S
S
c
c
r
r
e
e
e
e
n
n
-
-
5
5
0
0
0
0
((11))
R
R
A
A
D
D
I
I
U
U
S
S
A
A
c
c
c
c
o
o
u
u
n
n
t
t
i
i
n
n
g
g
R
ADIUS Start/Stop Yes
S
S
y
y
s
s
t
t
e
e
m
m
M
M
a
a
n
n
a
a
g
g
e
e
m
m
e
e
n
n
t
t
W
ebUI (HTTP and HTTPS) Yes
C
ommand Line Interface (console) Yes
Command Line Interface (telnet) Yes
Command Line Interface (SSH) Yes, v1.5 and v2.0 compatible
NetScreen-Security Manager Yes
A
ll management via VPN tunnel on any interface Yes
S
NMP Full Custom MIB Yes
R
apid deployment No
A
A
d
d
m
m
i
i
n
n
i
i
s
s
t
t
r
r
a
a
t
t
i
i
o
o
n
n
L
ocal administrators database 20
E
xternal administrator database RADIUS/LDAP/SecurID
R
estricted administrative networks 6
Root Admin, Admin, and Read Only user levels Yes
Software upgrades TFTP/WebUI/SCP/NSM
Configuration Roll-back Yes
T
T
r
r
a
a
f
f
f
f
i
i
c
c
M
M
a
a
n
n
a
a
g
g
e
e
m
m
e
e
n
n
t
t
Guara
nteed bandwidth Ye
s
Maximum bandwidth Yes
Ingress Tra
ffic Policing Yes
P
riority-bandwidth utilization Yes
DiffServ stamp Yes
E
E
x
x
t
t
e
e
r
r
n
n
a
a
l
l
F
F
l
l
a
a
s
s
h
h
PCMCIA (PC Card) Supports 96, 128, 440, and 512 MB
Event logs and alarms Yes
System config script Yes
NetScreen ScreenOS software Yes
D
D
i
i
m
m
e
e
n
n
s
s
i
i
o
o
n
n
s
s
a
a
n
n
d
d
P
P
o
o
w
w
e
e
r
r
Dimensions (H/W/L) 3.5/17.5/17 inches
Weight 27 lbs.
Rack mountable 19” standard, 23” optional
Power Supply (AC) 90 to 264 VAC, 100 watts
Power Supply (DC) -36 to -72 VDC, 100 watts
Licensing Options: The NetScreen-500 is available with two licensing options to provide
tw
o different levels of functionality and capacity.
Advanced Models: The A
dvanced software license provides all of the features and
capacities listed within this specsheet.
Baseline Models: The Baseline software license provides an entry-level solution for
customer environments where features such as Deep Inspection™, OSPF and BGP
dynamic routing, advanced High Availabilty, and full capacity are not critical
requirements. The following table shows the features and capacities that are different
than the Advanced models:
NetScreen-500 Baseline
Sessions 128,000
Concurrent VPN tunnels 1,000
Deep Inspection Firewall N/A
OSPF/BGP N/A
High Availability (HA) Active/Passive only
NetScreen Security Manager Supported
C
C
e
e
r
r
t
t
i
i
f
f
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
Safety Certifications
UL, CUL, CSA, CB
E
MC Certifications
F
CC class A, BSMI Class A, CE class A, C-Tick, VCCI class A
E
E
n
n
v
v
i
i
r
r
o
o
n
n
m
m
e
e
n
n
t
t
O
perational temperature: 32° to 122° F, 0° to 50° C
N
on-operational temperature: -4° to 158° F, -20° to 70° C
H
umidity: 10 to 90% non-condensing
M
M
T
T
B
B
F
F
(
(
B
B
e
e
l
l
l
l
c
c
o
o
r
r
e
e
m
m
o
o
d
d
e
e
l
l
)
)
6
.5 years
S
S
e
e
c
c
u
u
r
r
i
i
t
t
y
y
C
C
e
e
r
r
t
t
i
i
f
f
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
(
(
A
A
d
d
v
v
a
a
n
n
c
c
e
e
d
d
m
m
o
o
d
d
e
e
l
l
s
s
o
o
n
n
l
l
y
y
)
)
Common Criteria: EAL4
FIPS 140-2: Level 2
I
CSA Firewall and VPN
O
O
r
r
d
d
e
e
r
r
i
i
n
n
g
g
I
I
n
n
f
f
o
o
r
r
m
m
a
a
t
t
i
i
o
o
n
n
P
P
r
r
o
o
d
d
u
u
c
c
t
t
P
P
a
a
r
r
t
t
N
N
u
u
m
m
b
b
e
e
r
r
J
J
u
u
n
n
i
i
p
p
e
e
r
r
N
N
e
e
t
t
w
w
o
o
r
r
k
k
s
s
N
N
e
e
t
t
S
S
c
c
r
r
e
e
e
e
n
n
-
-
5
5
0
0
0
0
S
S
P
P
B
B
u
u
n
n
d
d
l
l
e
e
s
s
N
etScreen-500 System SX GBIC, AC power NS-500SP-GB1-AC
N
etScreen-500 System SX GBIC, DC power NS-500SP-GB1-DC
N
etScreen-500 System SX dual-GBIC, AC power NS-500SP-GB2-AC
N
etScreen-500 System SX dual-GBIC, DC power NS-500SP-GB2-DC
SP Systems include 25 Virtual Systems and 2 power supplies
J
J
u
u
n
n
i
i
p
p
e
e
r
r
N
N
e
e
t
t
w
w
o
o
r
r
k
k
s
s
N
N
e
e
t
t
S
S
c
c
r
r
e
e
e
e
n
n
-
-
5
5
0
0
0
0
E
E
S
S
B
B
u
u
n
n
d
d
l
l
e
e
s
s
NetScreen-500 System 2 SX GBIC modules,
2 AC power supplies NS-500ES-GB1-AC
NetScreen-500 System 2 SX GBIC modules,
2 DC power supplies NS-500ES-GB1-DC
NetScreen-500 System 2 SX dual-GBIC modules,
2 AC power supplies NS-500ES-GB2-AC
NetScreen-500 System 2 SX dual-GBIC modules,
2 DC power supplies NS-500ES-GB2-DC
NetScreen-500 System 3 dual-10/100 modules,
2 AC power supplies NS-500ES-FE1-AC
NetScreen-500 System 3 dual-10/100 modules,
2 DC power supplies NS-500ES-FE1-DC
NetScreen-500 System 2 dual-10/100 modules,
1 AC power supply NS-500ES-FE2-AC
NetScreen-500 System 2 dual-10/100 modules,
1 DC power supply NS-500ES-FE2-DC
ES Systems include 0 Virtual Systems.
J
J
u
u
n
n
i
i
p
p
e
e
r
r
N
N
e
e
t
t
w
w
o
o
r
r
k
k
s
s
N
N
e
e
t
t
S
S
c
c
r
r
e
e
e
e
n
n
-
-
5
5
0
0
0
0
B
B
a
a
s
s
e
e
l
l
i
i
n
n
e
e
S
S
y
y
s
s
t
t
e
e
m
m
s
s
NetScreen-500 System 2 dual-10/100 modules, 1 AC power supply NS-500B-FE2
NetScreen-500 System 2 SX GBIC modules, 1 AC power supply NS-500B-GB1
J
J
u
u
n
n
i
i
p
p
e
e
r
r
N
N
e
e
t
t
w
w
o
o
r
r
k
k
s
s
N
N
e
e
t
t
S
S
c
c
r
r
e
e
e
e
n
n
-
-
5
5
0
0
0
0
V
V
i
i
r
r
t
t
u
u
a
a
l
l
S
S
y
y
s
s
t
t
e
e
m
m
U
U
p
p
g
g
r
r
a
a
d
d
e
e
s
s
Upgrade to 5 Virtual Systems NS-500-VSYS-5
Upgrade from 5 to 10 Virtual Systems NS-500-VSYS-10
Upgrade from 10 to 25 Virtual Systems NS-500-VSYS-25
Ev
ery Virtual Sy
stem includes one virtual r
outer and 2 security zones, usable in the virtual
or r
oot sy
stem.
(1) Performance, capacity and features listed are based upon systems running ScreenOS 5.4 and are the measured maximums
under ideal testing conditions unless otherwise noted. Actual results may vary based on ScreenOS release and by
deployment.
(2)
Shar
ed among all Virtual Sy
stems
(3) Not available with Virtual Systems
(4) The following features are not supported in Layer 2 (transparent mode): NAT, PAT, policy based NAT, virtual IP, mapped IP,
virtual sy
stems
, virtual r
outer
s
, VLANs
, OSPF
, BGP, RIPv2, Active/Active HA, and IP address assignment.
(5) Requires purchase of virtual system key. Every virtual system includes one virtual router and two security zones, usable in
the virtual or root system.
Page 2
Copyright 2006, Juniper Networks, Inc. All rights reserved. Juniper Networks and the Juniper Networks logo are registered trademarks of Juniper
Networks, Inc. in the United States and other countries. All other trademarks, service marks, registered trademarks, or registered service marks in
this document are the property of Juniper Networks or their respective owners. All specifications are subject to change without notice. Juniper
Networks assumes no responsibility for any inaccuracies in this document or for any obligation to update information in this document. Juniper
Networks reserves the right to change, modify, transfer, or otherwise revise this publication without notice.
110005-007 July 2006
CCOORRPPOORRAATTEE HHEEAADDQQUUAARRTTEERRSS
AANNDD SSAALLEESS HHEEAADDQQUUAARRTTEERRSS
FFOORR NNOORRTTHH AANNDD SSOOUUTTHH AAMMEERRIICCAA
Juniper Networks, Inc.
1194 North Mathilda Avenue
Sunnyvale, CA 94089 USA
Phone: 888-JUNIPER (888-586-4737)
or 408-745-2000
Fax: 408-745-2100
wwwwww..jjuunniippeerr..nneett
EEAASSTT CCOOAASSTT OOFFFFIICCEE
Juniper Networks, Inc.
10 Technology Park Drive
Westford, MA 01886-3146 USA
Phone: 978-589-5800
Fax: 978-589-0800
AASSIIAA PPAACCIIFFIICC RREEGGIIOONNAALL
SSAALLEESS HHEEAADDQQUUAARRTTEERRSS
Juniper Networks (Hong Kong) Ltd.
Suite 2507-11, Asia Pacific Finance Tower
Citibank Plaza, 3 Garden Road
Central, Hong Kong
Phone: 852-2332-3636
Fax: 852-2574-7803
EEUURROOPPEE,, MMIIDDDDLLEE EEAASSTT,, AAFFRRIICCAA
RREEGGIIOONNAALL SSAALLEESS HHEEAADDQQUUAARRTTEERRSS
Juniper Networks (UK) Limited
Juniper House
Guildford Road
Leatherhead
Surrey, KT22 9JH, U. K.
Phone: 44(0)-1372-385500
Fax: 44(0)-1372-385501