Intelbras AMT 8000 LITE Monitored Alarm Center User guide

Category
Touch screen monitors
Type
User guide
Installation/User’s Guide
AMT 8000 LITE
AMT 8000 LITE
Alarm center
Congratulations, you have just purchased a product with Intelbras quality and safety.
The AMT 8000 LITE wireless alarm center features advanced technology and is easy to program. All 8000
series devices can be connected, exchanging encrypted information, for increased system security. The system
has differentials such as a high-performance wireless device communication (bidirectional) with a range of up
to 600 meters without barriers and direct sight, GPRS, GSM, and Ethernet type connections to provide easier
monitoring reporting to 2 IPs (monitoring companies) plus the Intelbras Cloud connection using initially the
random remote access password indicated along with the QR code label that also contains the MAC.
The AMT 8000 LITE center has remote software (rmware) updates, using Ethernet communication to download
the rmware version. In addition to this option, the center can also be updated using the BootLoader resource.
For this, it is necessary to have the Atualizador 8000 software previously installed on your computer.
ATTENTION: this product comes with a factory default password. For your safety, it is ESSENTIAL that you
change it as soon as you install the product and ask your technician about the congured passwords, which
users have access, and the recovery methods.
Care and Safety
» Follow all instructions in the manual to install and handle the product.
» Install in environments not susceptible to factors such as rain, fog and water splashes.
» Wireless communication technology, when exposed to environments with high power radiation, may suffer interference
and and have its performance impaired. Example: locations near TV towers, AM/FM radio stations, amateur radio sta-
tions, etc.
» Do not install the alarm center and its accessories near radio frequency equipment such as routers, repeaters, and/or
Wi-Fi signal ampliers. The center and its devices must maintain a minimum distance of 2 meters from this equipment.
» Do not install the alarm center in front of air conditioning or heating equipment.
» Do not expose to direct sunlight.
» Clean only the outside of the device, using a damp cloth (do not use chemical solvents).
» Do not subject the device to excessive pressure or shock/drops.
» Check that at the installation site, the LED indicator of the devices ashes green when activated.
» Avoid installation on metallic surfaces so as not to weaken the transmission signal between the system’s devices.
» The installation and conguration of the center and the other products that make up this system must be performed by
a qualied professional.
» Perform periodic tests on it, in order to validate weather conditions, battery level and other factors, so that the site
monitored by the system is always in proper operating condition.
» LGPD - General Personal Data Protection Act: Intelbras does not access, transfer, collect or otherwise process any perso-
nal data from this product.
Summary
1. Installation 5
2. Enter programming mode 7
2.1. Enter programming mode .....................................................................7
2.2. Exit programming mode .....................................................................7
3. Quick programming reference 7
3.1. Wireless devices ............................................................................7
3.2. Ethernet/GPRS connection ...................................................................14
3.3. Remote update ...........................................................................15
3.4. Passwords ...............................................................................15
3.5. Zone conguration .........................................................................16
3.6. Partition .................................................................................17
3.7. Timings .................................................................................17
3.8. Temporary conguration of the alarm center ......................................................18
3.9. Periodic testing ...........................................................................18
3.10. Auto-activation/Auto-Deactivation and Auto-activation/Auto-Deactivation by partitioning ...................18
3.11. Monitoring conguration ...................................................................19
3.12. Activation/deactivation of functions ...........................................................25
3.13. Failure sending time .......................................................................26
3.14. System reset ............................................................................26
3.15. Reset of the whole system ..................................................................26
3.16. Temporary reset of master and installer passwords ................................................26
4. Homologation 26
Warranty terms 27
5
1. Installation
1 3
4
2
5
6
7
8
9AMT 8000 LITE/PRO
Front view
1. Opening to pass the network cable (Ethernet).
2. Integrated siren connection.
3. Connector for Ethernet network cable.
4. Key for registration of wireless devices.
5. Input for power supply at cable.
6. Micro-USB connector to update the rmware of the alarm center.
7. Flat cable connector for XG 2G / XG 3G modules.
8. Connector for SIM card 1 and SIM card 2.
9. Input connector for the two-way battery cable.
Note:
the XG 2G and XG 3G modules are compatible with most national GSM operators with 2G and 3G technology.
6
1
3
2
AC AC
1. Tamper-proof key.
2. Integrated siren.
3. Connector for AC power supply.
Attention: be careful not to reverse the position of the ground wire.
Attention: The alarm center and AMT 8000 LITE do not have an auxiliary output to supply power to other devices and no
connection point on the center’s boards (center, GPRS card, or power supply) should be used for this functionality, since in addition
to damaging the alarm center and its accessories, the devices that are connected may be damaged because the alarm center
operates with variable voltages.
7
2. Enter programming mode
Note: to modify the technical parameters of your alarm center, it is recommended to contact a qualied technician.
2.1. Enter programming mode
To modify any of the center’s operating parameters, always enter the programming mode. To do this, enter the following
sequence:
Enter + Password (Master or Installer Password)
2.2. Exit programming mode
To exit programming mode, enter the master password or the installer password (the same password used to access
programming mode).
3. Quick programming reference
This quick reference assumes that the center is in programming mode and presumes that the entire manual has been read
and the result of each function is known.
Manual available on the website
www.intelbras.com.br.
When accessing the programming mode, editing or viewing some programming through the keyboard, if the sequence or
password is accepted, 2 conrmation beeps will be emitted, otherwise, a long error beep will be emitted, in which case
you must start entering the password or command again.
3.1. Wireless devices
Attention: If it is not possible to register the device to the alarm center, reset it by pressing the synchronization button
for approximately 10 seconds until the device LED indicator ashes red twice. This process ensures that the device will not
be linked to any other system, the keypad will display the message
Keypad not registered
and then the message
Register
keypad,
indicating that it can be registered again.
Registration by synchronization key
Press and release the synchronization key of the alarm center and wait until LED 3 lights up continuously, indicating that the
center is ready for registration of wireless devices. When you have nished registering all devices, press the synchronization
key of the alarm center again and check that LED 3 is out of Continuous mode (blinking indicating normal operation), showing
that the center has exited wireless device registration mode.
Maximum device capacity:
» Wireless keyboardss 16
» Remote controls 98
» Wireless sensors 64
» Wireless sirens 16
» Repeaters 04
» PGM actuators 16
Note: when physically deleting the devices, they must be deleted from the center’s memory through programming.
Otherwise, the wireless device supervision fault will be generated for these devices.
Keyboard commands for wireless devices
Keyboard
» Change the system language
Enter + 854 + I + Enter
» I = 0: Portuguese
» I = 1: Spanish
» I = 2: English
Note: function available as of version 1.0.1 of the XAT 8000 keyboard.
8
» Register the wireless keyboard
Enter + 620 + NT + Enter + Actuate the keypad by pressing the synchronization key.
NT = keyboard number from 01 to 16.
» Delete wireless keyboards
Enter + 720 + NT + Enter.
NT = keyboard number from 01 to 16.
» Keyboard rmware preview
Enter + 642 + TT + Enter
TT = 2-digit keypad number
Note:
function available for keyboards from version 2.0.0 onwards.
» Wireless keyboard partitioning
Enter + 223 + NT + PP + Enter.
NT = keyboard address from 01 to 16.
PP = partition from 00 to 16 (00 = common address for all zones and 01 to 16 the individual partitions of the center).
» Change messages
Enter + GM + Active + User, device, partition or zone + Enter.
GM = group of messages from 1 to 8.
User, device, partition or zone = in case of messages for zone 1 to 64, device from 01 to 16, partition from 01 to 16 and
in case of user from 00 to 99.
Description Message group User, device, partition
or zone
Alarm center name 100
Users 200 to 99
Zones 301 to 64
Partitions 401 to 16
PGM 501 to 16
Keyboards 601 to 16
Sirens 801 to 16
» Resetting messages
Enter + 1 + Disable + Enter.
Note:
resets all messages of the center to factory defaults for the selected language.
»Panic key
Enter + 540 + P + Enter.
» P = 0: Disabled.
» P = 1: Audible panic.
» P = 2: Silent panic.
» P = 3: Fire panic.
» P = 4: Medical emergency.
9
Remote control
» Remote control registration
Enter + 60 + NU + Enter + Actuate the control by pressing one of the keys
.
NU = user number from 00 to 97.
» Delete remote control
Enter + 70 + NU + Enter.
NU = user number from 00 to 97.
» Remote control key functions
Enter + 65 + T + NU + FC + Enter.
T = control key from 1 to 3.
NU = user number from 00 to 97.
FC = function of the key that will be linked to the selected key from 00 to 66.
00 Disabled
01 Atv/Dtv all partitions
02 Only activates all partitions
03 Only disables all partitions
04 Atv/Dtv all partitions in
Partial
mode
05 Only arms in Partial mode
06 Panic with siren
07 Silent panic
08 Fire panic
09 Medical emergency
10 N/A
11 Atv/Dtv only Partition 1
12 Atv/Dtv only Partition 2
13 Atv/Dtv only Partition 3
14 Atv/Dtv only Partition 4
15 Atv/Dtv only Partition 5
16 Atv/Dtv only Partition 6
17 Atv/Dtv only Partition 7
18 Atv/Dtv only Partition 8
19 Atv/Dtv only Partition 9
20 Atv/Dtv only Partition 10
21 Atv/Dtv only Partition 11
22 Atv/Dtv only Partition 12
23 Atv/Dtv only Partition 13
24 Atv/Dtv only Partition 14
25 Atv/Dtv only Partition 15
26 Atv/Dtv only Partition 16
27 N/A
28 N/A
29 N/A
30 N/A
31 Atv/Dtv partial mode only for Partition 1
32 Atv/Dtv partial mode only for Partition 2
33 Atv/Dtv partial mode only for Partition 3
34 Atv/Dtv partial mode only for Partition 4
35 Atv/Dtv partial mode only for Partition 5
36 Atv/Dtv partial mode only for Partition 6
37 Atv/Dtv partial mode only for Partition 7
38 Atv/Dtv partial mode only for Partition 8
39 Atv/Dtv partial mode only for Partition 9
10
40 Atv/Dtv partial mode only for Partition 10
41 Atv/Dtv partial mode only for Partition 11
42 Atv/Dtv partial mode only for Partition 12
43 Atv/Dtv partial mode only for Partition 13
44 Atv/Dtv partial mode only for Partition 14
45 Atv/Dtv partial mode only for Partition 15
46 Atv/Dtv partial mode only for Partition 16
51 PGM 01
52 PGM 02
53 PGM 03
54 PGM 04
55 PGM 05
56 PGM 06
57 PGM 07
58 PGM 08
59 PGM 09
60 PGM 10
61 PGM 11
62 PGM 12
63 PGM 13
64 PGM 14
65 PGM 15
66 PGM 16
Wireless sensors
» Register wireless sensors
Enter + 61 + ZZ + Enter + Actuate the sensor by pressing the synchronization key.
ZZ = zone to which the sensor will be linked from 01 to 64.
» Delete wireless sensors
Enter + 71 + ZZ + Enter.
ZZ = zone to which the sensor will be linked from 01 to 64.
»Adjustment of the wireless infrared sensors
Enter + 66 + ZZ + S + L + M + Enter.
Z = zone from 01 to 64.
S = Sensitivity from 0 to 3, where 0 = minimum sens. / 1 = normal sens. / 2 = intermediate sens. / 3 = maximum sens.
L = Sensor LED, where 0 = Off / 1 = On.
M = Sensor operating mode, where 0 = Economical / 1 = Continuous.
Note:
for the XAS 8000 and TX 8000 the Sensitivity, Sensor LED and Operation mode settings are allowed by the center,
but only the LED setting is accepted by the XAS 8000 and TX 8000
.
»Wireless sensor test
Enter + 52 + Enter + Actuate sensor.
»Disable sensor tamper
Enter + 78 + X + Enter.
X = Zone group 0 to 6
»Disable digital tamper of IVP 8000 EX sensor
Enter + 79 + X + Enter.
X = Zone group de 0 a 6
11
»Restoring the digital tamper of the IVP 8000 EX sensor
Enter + 543 + ZZ+ Enter.
ZZ= 2-digit zone number.
»Display of sensors rmware
Enter + 641 + ZZ + Enter.
ZZ = 2-digit zone number.
Note:
function is available for devices with version 2.0.0.0 and higher. For devices with a version lower than 2.0.0.0,
0.0.0.0 will be displayed.
Wireless sirens
» Register wireless sirens
Enter + 621 + NS + Enter + Actuate the siren by pressing the synchronization key.
NS = siren number from 01 to 16.
» Delete wireless sirens
Enter + 721 + NS + Enter.
NS = siren number from 01 to 16.
Note:
it is not possible to delete the position of the integrated siren.
» Partitioning of wireless sirens
Enter + 222 + NS + PP + Enter.
NS = siren number from 01 to 16.
PP = partition from 00 to 16 (00 = common address for all zones and 01 to 16 the individual partitions of the center).
» Enable/disable siren beep on system activation/deactivation
Enter + 510 + Enter + Key 3 + Enter.
»Enable/disable siren beep per partition
Enter + 224 + GP + Enter.
GP = group of partitions, with partitions 01 to 10 in group 0 and partitions 11 to 16 in group 1.
» Enable/disable integrated siren
Enter + 541 + Enter
After the command, use the 1 key on the keyboard to enable or disable the function and press the
Enter
key to conrm.
» Change siren time
Enter + 41 + TS + Enter.
TS = siren time from 01 to 99.
Note:
factory default 5 minutes, and if 00 is set in the command, an error beep will be emitted.
» Register RF range amplier (REP 8000 repeater)
Enter + 622 + NA + Enter + Actuate the amplier by pressing the synchronization key.
NA = amplier number from 01 to 04.
» Delete RF Range Amplier (REP 8000 Repeater)
Enter + 722 + NA + Enter
NA = amplier number from 01 to 04.
12
» Repeater rmware verication
Enter + 644 + RR + Enter.
RR = 2-digit repeater number.
Route change by command
» Search for new route sensors
Enter + 544 + ZZ + Enter.
ZZ = 2-digit zone number.
» XAT 8000 new route search
Enter + 545 + TT + Enter.
TT = 2-digit keypad number.
» PGM 8000 new route search
Enter + 547 + PP + Enter.
PP = 2-digit PGM number.
Note: function available for devices from version 2.0.0 onwards.
» Register Actuator PGM 8000
Enter + 623 + PGM + Enter + Actuate the Actuator by pressing the synchronization key.
PGM = Actuator number from 01 to 16.
» Delete PGM 8000 actuator
Enter + 723 + PGM + Enter.
PGM = Actuator number from 01 to 16.
Firmware verication of PGM 8000 actuators
Enter + 646 + PP + Enter.
PP = 2-digit PGM number.
Note: function available for devices from version 2.0.0.
» PGM 8000 actuator functions
Enter + 50 + PGM + Enter + M + E + Enter.
PGM = PGM number from 01 to 16.
M = PGM operation mode from 0 to 9 (0 = on/off, 1 to 8 = pulse and 9 = programmed time).
E = Event that actuates PGM from 00 to 13.
00 External actuation (applications)
01 Password actuation (passwords from 51 PGM01 to 66 PGM16)
02 System activation
03 System deactivation
04 Medical emergency:
05 Event communication failure
06 N/A
07 Siren problem:
08 Trigger
09 Trigger or silent panic
10 Fire zone triggering:
11 Zone 1 opening
12 Remote control
13 Activation / deactivation by time
» Time programmed for PGM 8000 to remain on
Enter + 560 + PGM + T + Enter.
PGM = PGM number from 01 to 16.
T = Time from 01 to 99 minutes.
13
» Days for Programmed auto-activation of PGM 8000 Actuator
Enter + 836 + PGM + Enter.
PGM = PGM number from 01 to 16.
After the command, with the keyboard keys, select the days of the week from 1 to 7, where 1 = Sunday, 2 = Monday, 3 =
Tuesday, 4 = Wednesday, 5 = Thursday, 6 = Friday, 7 = Saturday and 8 = holiday and conrm with Enter.
» Time of auto-activation of the PGM 8000 Actuator
Enter + 561 + PGM + D + HH + MM + Enter.
PGM = PGM number from 01 to 16.
D = day of the week from 1 to 7 (1 = Sunday, 2 = Monday, 3 = Tuesday, 4 = Wednesday, 5 = Thursday, 6 = Friday, 7 =
Saturday and 8 for holidays).
HH = hours from 00 to 23.
MM = minutes from 00 to 59.
» Days for programmed auto-deactivation of the PGM 800 Actuator
Enter + 837 + PGM + Enter.
PGM = PGM number from 01 to 16.
After the command, with the keyboard keys, select the days of the week from 1 to 7, where 1 = Sunday, 2 = Monday, 3 =
Tuesday, 4 = Wednesday, 5 = Thursday, 6 = Friday, 7 = Saturday and 8 = holiday and conrm with Enter.
» Time of auto-deactivation of the PGM 800 Actuator
Enter + 562 + PGM + D + HH + MM + Enter.
PGM = PGM number from 01 to 16.
D = day of the week from 1 to 7 (1 = Sunday, 2 = Monday, 3 = Tuesday, 4 = Wednesday, 5 = Thursday, 6 = Friday, 7 =
Saturday and 8 for holidays).
HH = hours from 00 to 23.
MM = minutes from 00 to 59.
» Holidays for auto-activation/auto-deactivation of the PGM 800 Actuator
Enter + 564 + PGM + F + DD + MM + Enter.
PGM = PGM number from 01 to 16.
F = holiday memory number 0 to 9.
DD = day from 01 to 31.
MM = month from 01 to 12.
» PGM 8000 actuator association for partitioning
Enter + 563 + PGM +PP + Enter.
PGM = PGM number from 01 to 16.
PP = partition from 01 to 16.
Reset wireless devices
» Delete all registered wireless devices
Enter + 7 + Disable + Enter.
1
All wireless devices in the switchboard will be unregistered, including the keypad that is being used.
» RF channel change
Enter + 630 + RF + Enter.
RF = channels from 08 to 11.
Attention: when changing the alarm center channel, all devices registered to the alarm center (except the remote control)
must have the synchronization key pressed to direct the device to the new channel, otherwise they will not communicate
with the alarm center.
14
3.2. Ethernet/GPRS connection
» Ethernet: An RJ45 type cable must be installed in the center with the Ethernet signal coming from a router, switch or
directly from the signal received at the installation site. Check with the Internet provider whether the port used allows
external access.
» GPRS: with the GPRS connection enabled in the alarm center, the reporting of events and connections will use this
channel, and for this purpose the XG 2G or XG 3G module must be implemented together with the center and chips
with access to a data packet must be installed. To communicate via GPRS, the chip (SIM card) must be enabled for a
packet data plan. It is not necessary to enable voice service. Consult the operator to acquire the most suitable plan for
the information trafc of the alarm center.
In order to establish the GPRS connection with the alarm center, the following congurations must be
made.
» Enable chips
Enter + 832 + Enter.
» After the command, use the keyboard keys to enable options 1 (chip 1) and 2 (chip 2).
Program login
Enter + 822 + O + Enter
, where O = 1 or 2 (Operator 1 or Operator 2)
After the command, type the user name (depending on the operator used) and then press the
Enter
key to conrm.
» Program password
Enter + 823 + O + Enter,
where O = 1 or 2 (Operator 1 or Operator 2)
After the command, type the password (depending on the operator used) and then press the
Enter
key to conrm.
» Program APN
Enter + 824 + O + Enter,
where O = 1 or 2 (Operator 1 or Operator 2)
After the command, type the APN (depending on the operator used) and then press the
Enter
key to conrm.
Program the PIN (Personal Identication Number)
If you want to use the PIN, perform the command in sequence, otherwise go to the next command.
If the PIN is wrong, the chip will be blocked.
Enter + 825 + O + PIN number with 4 digits +
where O = 1 or 2 (Operator 1 or Operator 2))
After selecting the type of connection to be used, it is necessary to carry out the following steps to verify/
congure some points of the connection, such as verifying the IP address that the center is operating
from.
IP address of the center
Enter + 8120 + Enter.
The IP address of the center will be displayed if DHCP is enabled, if DHCP is disabled you can manually enter the IP
address of the center.
» Program DHCP
If you do not have a DHCP server or do not want to use this option, proceed to the next step, otherwise, type the next
command and the following ones as well.
Enter + 831 + Enter.
After the command, using the keys on the keyboard, enable option 1 (dial 1) and press the Enter key to conrm. To
disable, leave option 1 unchecked.
Program the network mask
Enter + 8130 + Enter.
After the command, type the netmask number and press the
Enter
key to conrm.
Program the gateway
Enter + 8140 + Enter.
After the command, type the network gateway number and press the
Enter
key to conrm.
15
» Program DNS servers for Ethernet
Enter + 815 + S + Enter, where S = 1 or 2 (Server 1 or Server 2)
.
After the command, type the DNS1 server number and press the Enter key to conrm.
3.3. Remote update
To download/check out a new version
Enter + 9922 + Enter.
If there is a version available for download, the message Download Wait will appear and the download will start, which
will take between 3 and 5 minutes (depending on the network). If the center does not have a version to download, the
message
Download failed
will appear.
Install the download version
Enter + 9933 + Enter.
The newly downloaded version will be installed and the records and programming of the center will not be lost. To check
the software version of the center, access the Menu and using the arrow keys access the Version of the center to display it.
Note
: the center must be connected to the Ethernet. It is not possible to download/update the software through the GPRS
connection due to the download speed of the connection and the excessive consumption of the packet used.
3.4. Passwords
Password programming 1 (exclusive programming for the programmer user)
» Change passwords for users of positions 98 and 99
Enter + 20 + NU + PASSWORD + Enter.
NU = user number 98 or 99.
PASSWORD
= password to be programmed containing 4 or 6 digits.
» Delete the user’s password from position 98
Enter + 20 + 98 + Enter.
1
The password for position 99 cannot be deleted.
Password programming 2 (exclusive programming for the master user)
» Change/create passwords for users in positions 00 to 97.
Enter + 20 + NU + PASSWORD + Enter.
NU = user number from 00 to 97.
PASSWORD = 4 or 6 digit password to be programmed.
» Delete password for users in positions 01 to 97
Enter + 20 + NU + Enter.
NU = user number from 01 to 97.
1
The password for position 00 cannot be deleted.
Password permissions
» Dene permission for password partitioning
Enter + 21 + NU + GP + Enter.
NU = n user number from 01 to 96.
GP = group of partitions, with partitions 01 to 10 in group 0 and partitions 11 to 16 in group 1.
» Dene permission only for activation or permission for
bypassing
Enter + 2 + P + GS + Enter + Select password + Enter.
P = permission setting, 5 active only and 6
bypass
permission.
GS = group of passwords from 0 to 9, with group 0 going from 01 to 10, group 1 from 11 to 20 and so on closing with
group 9 from 91 to 97.
16
» Dene permission for partial mode
Enter + 221 + GS + Enter + Select password + Enter.
GS = group of passwords from 0 to 9, with group 0 going from 01 to 10, group 1 from 11 to 20 and so on closing with
group 9 from 91 to 97.
3.5. Zone conguration
Enable/disable zones
Enter + 30 + G + Enter.
G = group of zones from 0 to 6.
After entering the command, using the keyboard keys, enable/disable the corresponding zones for the group and press
the
Enter
key to conrm.
Enable partial mode
Enter + 02 + G + Enter.
G = group of zones from 0 to 6.
After entering the command, using the keyboard keys, enable/disable the corresponding zones for the group and press the
Enter
key to conrm. It is also necessary that the passwords have the
Stay
mode permission.
Zone functions
Enter + 3 + F + G + Enter.
F = functions of zones 1 to 6.
G = group of zones from 0 to 6.
After entering the command, using the keyboard keys, enable/disable the corresponding zones for the group and press
the
Enter
key to conrm.
Zone functions
1Timed
2Follower
324 hours
4Panic
5Medical emergency
6Fire
Zone operation mode
Enter + 0 + MP + G + Enter.
MP = mode of zones 7 or 8.
G = zone group 0 to 6.
After entering the command, using the keyboard keys, enable/disable the corresponding zones for the group and press
the
Enter
key to conrm.
MP Operation Mode
7Silent
8Normally open contact
Automatic Zone Cancellation
Enter + 53 + N + Enter.
N = number of triggers from 0 to 9.
On input
Enter + 09 + ZZ + Enter
ZZ= zones 01 to 64
17
On input partition
Enter + 516 + GP + Enter
GP = group of partitions, with partitions 01 to 10 in group 0 and partitions 11 to 16 in group 1.
Permission to activate and/or deactivate the oninput
Enter + 518 + Enter
Tecla 2 – Permission to activate
Tecla 3 – Permission to deactivate
3.6. Partition
Enable partition
Enter + 510 + Enter + Select option 1 + Enter.
Zone partitioning
Enter + 01 + ZZ + PP + Enter.
ZZ = zone from 01 to 64.
PP = partition from 01 to 16.
»Dene permission for password partitioning
Enter + 21 + NU + GP + Enter.
NU= user number from 01 to 96.
GP = group of partitions, with partitions 01 to 10 in group 0 and partitions 11 to 16 in group 1.
Attention: In addition to the programming points mentioned above, it is necessary to create/dene user passwords
(topic
3.4. Passwords)
as well as register wireless controls for access
(topic Remote Control)
. It is also necessary to dene the
partitioning of keyboards
(topic Keyboard)
and sirens
(topic Wireless Sirens).
3.7. Timings
Input timing
Enter + 42 + PP + TTS + Enter.
PP = partition from 01 to 16 (center without partition, use PP = 01).
TTS = time from 000 to 255 seconds.
»Beep adjustment on input timing
Enter + 542 + A + Enter.
A= 0 - Disabled
1. Low
2. Medium
3. High
Output timing
Enter + 44 + PP + TTS + Enter.
PP = partition from 01 to 16 (center without partition, use PP = 01).
TTS = tempo from 000 to 255 seconds (beeps will be emitted only through the keyboard and not through the integrated
siren).
18
Disable the output beep
Enter + 514 + Enter + Key 8 + Enter.
3.8. Temporary conguration of the alarm center
Clock
Enter + 400 + HH + MM + SS + Enter.
HH = hours from 00 to 23.
MM = minutes from 00 to 59.
SS = seconds from 00 to 59.
Calendar
Enter + 401 + DD + MM + AA + Enter.
DD = day from 01 to 31.
MM = month from 01 to 12.
YY = year from 00 to 99.
Setting the day of the week
Enter + 402 + D + Enter.
D = day of the week from 1 to 7 (1 = Sunday, 2 = Monday, 3 = Tuesday, 4 = Wednesday, 5 = Thursday, 6 = Friday, 7 = Saturday).
Time interval for time and date synchronization
Enter + 403 + HHH + Enter.
HHH = interval between synchronizations from 000 to 255 hours.
3.9. Periodic testing
Enable periodic testing by time schedule
Enter + 470 + HH + MM + Enter.
HH = hours from 00 to 23.
MM = minutes from 00 to 59.
Disable periodic test by time schedule
Enter + 470 + Disable + Enter.
Periodic testing by time interval
Enter + 471 + HHH + Enter.
HHH = hours from 000 to 255.
3.10. Auto Activation/Auto Deactivation and Auto Activation/Auto Deactivation by partitioning
Enable auto-activation on inactivity
Enter + 460 + TM + Enter.
TM = time from 00 to 99 minutes.
Selection of auto activation/auto deactivation by partitions
Enter + 464 + GP + Enter.
GP = Partition group 0 or 1 (0 = partition group 01 to 10 and 1 = partition group 11 to 16).
Dene Holidays
Enter + 404 + PP + F (0 a 9) +DD + MM + Enter
PP = Partition (center without partition, use PP = 01)
F = holiday memory number from 0 to 9.
DD = day of the month that will be holiday from 01 to 31.
MM = holiday month from 01 to 12.
19
Day of the week auto activation
Enter + 838 + PP + Enter.
PP = partition from 01 to 16 (center without partition, use PP = 01).
After the command, use the keyboard keys to select the days of the week from 1 to 7, where 1 = Sunday, 2 = Monday, 3
= Tuesday, 4 = Wednesday, 5 = Thursday, 6 = Friday, 7 = Saturday.
Auto activation schedule
Enter + 462 + PP + D + HH + MM + Enter.
PP = partition from 01 to 16 (center without partition, use PP = 01).
D = day of the week from 1 to 7 (1 = Sunday, 2 = Monday, 3 = Tuesday, 4 = Wednesday, 5 = Thursday, 6 =
Friday, 7 = Saturday).
HH = hours from 00 to 23.
MM = minutes from 00 to 59.
Day of the week auto deactivation
Enter + 839 + PP + Enter.
PP = partition from 01 to 16 (center without partition, use PP = 01).
After the command, use the keyboard keys to select the days of the week from 1 to 7, where 1 = Sunday, 2 = Monday, 3
= Tuesday, 4 = Wednesday, 5 = Thursday, 6 = Friday, 7 = Saturday.
Auto deactivation schedule
Enter + 463 + PP + D + HH + MM + Enter.
PP = partition from 01 to 16 (center without partition, use PP = 01).
D = day of the week from 1 to 7 (1 = Sunday, 2 = Monday, 3 = Tuesday, 4 = Wednesday, 5 = Thursday, 6 =
Friday, 7 = Saturday).
HH = hours from 00 to 23.
MM = minutes from 00 to 59.
Dene holidays for auto activation/auto deactivation
Enter + 404 + PP + F + DD + MM + Enter.
PP = partition from 01 to 16 (center without partition, use PP = 01).
F = holiday memory number from 0 to 9.
DD = day from 01 to 31.
MM = month from 01 to 12.
3.11. Monitoring conguration
» Program monitoring account
Enter + 15 + PP + Enter
, where PP = partition from 01 to 16. After the command: type the 4-digit monitoring account
number (0 to 9 or the letters B, C, D, E and F) and press the Enter key to conrm. If the center is not partitioned, use the
partition as
01.
» Event report mode
Enter + 17 + AAA + Enter.
AAA = indicates in which mode the alarm center will operate, where 000: disabled, 400: regular IP and 600: dual IP.
» Blocking the delivery of partition 00 to the monitoring company
Enter + 515 + Enter.
After the command, with the keyboard keys, enable option 8 ( mark 8) and press the Enter key to conrm.
» Reset of pending events
Enter + 16 + Enter.
20
Via Ethernet
» Program monitoring account
Enter + 15 + PP + Enter,
where PP = partition from 01 to 16. After the command: type the 4-digit monitoring account
number (0 to 9 or the letters B, C, D, E and F) and press the Enter key to conrm. If the center is not partitioned, use the
partition as
01.
» Program the report mode
Enter + 17 + AAA + Enter.
AAA = indicates in which mode the alarm center will operate, where 000: disabled, 400: regular IP and 600: dual IP.
» Program communication priority
Enter + 19 + 0 + Enter.
» Program destination IP
Enter + 801 + I + Enter,
where I = Destination IP 1 or 2.
After the command type the IP number of the monitoring company (example: 192.168.001.100) and press the
Enter
key
to conrm.
» Program IP network communication port
Port 1 = Enter + 802 + 1 + 4-digit port number + Enter.
Port 2 = Enter + 802 + 2 + 4-digit port number + Enter
» Program the destination domain name (DNS)
If you don’t want to use DNS, skip to the next command, otherwise type:
Enter + 803 + D + Enter, D = 1 or 2 (DNS 1 or DNS 2).
After the command type the DNS domain name and press the
Enter
key to conrm.
» Program IP monitoring options
Enter + 830 + Enter.
After the command, using the keys on the keyboard, enable the desired option from 1 to 4, where:
» 1 = enables the sending of events to the monitoring company 1.
» 2 = enables the sending of events to the monitoring company 2.
» 3 = Enables the domain name (DNS) of the monitoring company. 1.
» 4 = Enables the domain name (DNS) of the monitoring company. 2 and press the
Enter
key to conrm.
» Program DHCP
If you do not have a DHCP server or do not want to use this option, proceed to the next step, otherwise, type the next
command and also the following commands.
Enter + 831 + Enter.
After the command, with the keyboard keys, enable option 1 (dial 1) and press the
Enter
key to conrm.
» Center IP address
Enter + 8120 + Enter.
After the command, enter the IP address of the center.
Note: you will only be able to edit/enter the address manually if the DHCP function is disabled, otherwise, only the IP
address of the center will be displayed.
» Program the netmask
Enter + 8130 + Enter.
After the command, type the netmask number and press the
Enter
key to conrm.
» Program the gateway
Enter + 8140 + Enter.
After the command, type the Gateway and press the Enter key to conrm.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Intelbras AMT 8000 LITE Monitored Alarm Center User guide

Category
Touch screen monitors
Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI