Universal Tubs HD6247-FF-60375 Installation guide

Type
Installation guide

This manual is also suitable for

EXPLODED DRAWING
Notes For reference only. We reserve the right
to make changes without any notice.
:
Please read the followings before installing and usage.
[inch]For Reference only (unit = mm )
DIMENSIONS
RECOMMENDED TOOLS
FAUCET MAINTENANCE
CARE INSTRUCTIONS
To keep your faucet looking its best, please follow
these simple care instructions:
1. Remove as much surface dirt and film using
clear water and a soft cotton cloth.
2. Use any of the following to remove tough
surface film and build-up:
- Mild liquid detergent
- Non-acidic, non-abrasive gentle liquid cleanser
- Non-abrasive liquid polisher.
3. Once clean, rinse faucet with clear water to
thoroughly remove cleaner or polish and blot
dry with soft cotton cloth.
1. Use abrasive cleansers, cloths, or paper towels.
2. Use any cleaning agents containing acids, polish,
waxes, alcohol, ammonia, bleach, solvents or any
other corrosive or harsh chemical cleansers.
DO:
DO NOT:
NO.
Part No
Qty
CTCB0493
CTRR0117
CTST0057
CTWT0009
CTHB0195
CTHB0196
CTDB0312
CTDB0308
CTWP0208
CTMB0458
CTRR0085
CTCB0494
CTWR0207
CTCT0035
CTWQ0007
CTNP0046-XR
ATBQ0226
CTHB0208
CTMB0459
CTWP0209
ATBF0117
CTRR0009
CTRR0128
CTWP0221
CTWR0254
CTQP0029
CTPB0437
CTRR0118
CTXB0045
CTPB0436
CTRR0172
CTDB0307
CTRR0113
CTWR0053
CTNP0046-XD
ATBQ0225
CTPB0413
CTWR0217
CTWT0038
CTNB0059
CTHB0209
CTLB0095
CTCB0496
CTMB0461
CTNB0056
CTMB0515
CTBT0053
CTNB0240
CTWB0048
CTRR0138
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
22
23
24
25
26
27
28
29
30
31
32
33
3
4
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
21
2
2
2
2
2
2
2
2
4
2
3
2
2
2
2
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
2
Part Desc
COVER
O-RING
SCREW
WASHER
STEM
HANDLE
BASE
BASE
WASHER
SHANK
O-RING
STEM
WASHER
BASE SEAT
WASHER
NUT
VAVLE
STEM
SHANK
WASHER
SPOUT
O-RING
O-RING
WASHER
WASHER
AERATOR
SHANK
O-RING
SHANK
O-RING
BASE
O-RING
WASHER
NUT
VAVLE
SHANK
WASHER
WASHER
NUT
PULL ROB
STEM
STEM
SHANK
NUT
POLE
SPRING
NUT
WASHER
WASHER
AERATOR COVER
NO.
Part No
CTDB0133
CTRR0139
CTPB0415
CTWR0090
CTPB0404
CTRR0062
CTMB0452
ATBE0043
ATBA0274
CTDB0042
ATBA0100
CTWR0060
CTWR0061
CTNB0016
ATBP0071
ATBP0070
ATBP0013
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
Qty
Part Desc
STOP
O-RING
SHANK
WASHER
BODY
O-RING
ADAPTER
SHOWER
CHECK VALVE
BASE
CHECK VALVE
WASHER
WASHER
NUT
HOSE
HOSE
HOSE
FR-AZ376
Installation Guide
For more information visit
www.ANZZI.com or call
1-844-44-ANZZI
Step 1 Step 4
Handle installation
1
2
3
3
Disassemble the cold water handle
(identified by a blue nut).
Leave the bottom retainer ring as well as the
washer in place. From under the bathtub
insert the cold water valve (indentified by a C)
in the hole located on the right of the spout hole.
From the top, install the nut and washer.
Screw the nut to secure the valve, handle
flange and handle in place.
Repeat steps to install the handle and hot
water valve (identified by an H) in the hole
located on the left of the spout hole.
Step 2
1
Spout installation
Unscrew the Allen screw from behind the
spout. Pull apart the spout from its connector
Unscrew the nut of the spout shank. From the
top of the bathtub, put the gasket and the
washer on the bathtub, insert the shank in the
hole between the two handles. From
underneath the bathtub, install the washer,
metal washer and screw the nut to secure the
shank in place.
2
Tighten spout in place by screwing the Allen
screw behind the spout.
3
Step 3
1
1
Diverter installation
Unscrew the bottom nut and take off
rubber washer.
Insert the hand shower holder in the hole
making sure to place the washer underneath
the fix holder. From under, screw the rubber
washer, as well as the retainer ring to the
holder in place.
2
Connect the hose to the hand shower, making
sure that the rubber washer is in place. From
above, slide the hose through the holder to sit
the hand shower on its base.
Repeat steps to install the handle and
diverter in the hole located on the right of the
cold water handle.
Step 5
1
2
Valve and water supply connection
Using the flexible connectors included,
connect the valves to the diverter and diverter
to the spout. Use the extra flexible connector
to join the diverter to the hand shower hose.
Tighten using appropriate tool (ill. A&A1).
Connect hot and cold valves to the
corresponding water supply lines using
flexible connectors (not included) and
tighten (ill.B).
A1
B
A
1
Testing connections
Verify that there are no leaks by slowly
opening the hot and cold water. In case
of a leak, shut off the water supply and
tighten connectors 1 4 turn using the
appropriate tool. Repeat if necessary.
/
Turn on the faucet and leave both hot
and cold water running for at least one
minute to evacuate the air trapped in
the pipes. Turn off water.
WARNING: Remove aerator before
testing connections. Do not overtighten.
Assemble the aerator as illustrated and
insert into the spout, tightening by hand.
You can now turn on water supply.
2
3
Hand shower holder installation
Step 4
  • Page 1 1
  • Page 2 2

Universal Tubs HD6247-FF-60375 Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI