OPERATINGMANUAL
PROGRAMMABLECOUNTER
PC-3006
Page-1
PC-3006 www.multispanindia.com
TechnicalSpecification
WorkingPrinciple
1).Whenpulsecomesfromsensor,DisplayindicatesincreaseʻCOUNTʼ.
2).ForManualMode,settime=00.0sec.andforAutoResetMode,settime=00.1to99.9sec.
3).Whenprocessvalue=setpointvalue,Relayenergeis.RelayremainsONforAutoReset
TimeRelayturnsoffaftercompletionoftime.Iftimeissetat00.0sec.thenrelayremainsON
untilRSTkeyispressed.
4).IfthereisapowerfailurethelastreadingisstoredinthememoryandCounterstartsresume
countingfromthelaststoredvalue,whenpowerON.
5).TorestartCountingortoResetpressRSTkey.Upperdisplaywillshow000000andthe
countingwillrestart.
6).Theproximityswitchgivepulsetocountereverytimethemetalontherollerissensed.
1relay,1C/O,230VAC,5A
44X92mm
230VAC
PowerFailFacility
FrontResetKey&Resetatback
Model
PanelCutout
Dimension
Display
Output
Sensor
Supply
Memory
Reset
48X96X120mm
SingleDisplay:6digit,0.4ʼʼ,7segment,RedLED
PC-3006
ProximityPNP/NPNSwitchSelectableµswitch
RELAY T R
PC 3006
SET
ENT
RESET
RPM
BATCH
COUNTER