Epson RZ-TX0101N User guide

Category
Watches
Type
User guide

Epson RZ-TX0101N is a versatile device that combines printing, copying, and scanning functions. With its compact size and Wi-Fi connectivity, it's ideal for home or small office use. Print high-quality documents and photos with Epson's PrecisionCore technology, and easily copy or scan documents with the automatic document feeder. The RZ-TX0101N also supports mobile printing via the Epson iPrint app, making it convenient to print from smartphones or tablets.

Epson RZ-TX0101N is a versatile device that combines printing, copying, and scanning functions. With its compact size and Wi-Fi connectivity, it's ideal for home or small office use. Print high-quality documents and photos with Epson's PrecisionCore technology, and easily copy or scan documents with the automatic document feeder. The RZ-TX0101N also supports mobile printing via the Epson iPrint app, making it convenient to print from smartphones or tablets.

USERS GUIDE
Meaning of symbols used in this manual
Precautions
About the Product
Names and Functions of Individual Component Parts
Specifications
To Maintain Stable Operation
Estimated Required Charging Time
How to Set the Time
Stop watch 1/5-second
Charging Method
How to Set the Calendar
How to Use the Stopwatch
The watch charges when light hits the dial.
To operate the watch when it is stopped or if the battery level is
low, charge the watch in accordance with the estimated required
charging time.
○when you start using the watch
There may be insufficient energy. It does not have to be fully
charged but make sure that it is adequately charged.
○If the second hand moves in 2-second intervals:
Charging is insufficient. Charge the battery until the second hand
moves continuously in 1-second intervals.
Energy Depletion Warning Function
In order to prevent harm to users and third parties, as well as
damage to property, the following warning signs are used to indicate
that operation or handling involves danger.
Do not place the watch near light sources that generate heat
while
charging (such as lights for photography or incandescent lights).
The watch may overheat causing a fire, failure, or malfunction to
occur.
Do not charge near a light source with high illuminance (LED,
etc.).The watch and band may causing cause discoloration.
Charging for longer than the required time for full charge will not
damage the watch.The overcharging prevention function operates
automatically.
This is the time required to charge the watch from 2-second interval
movement to continuous 1-second interval movement when a
stopped watch is exposed to light. If the charging time is too short,
the second hand starts moving in 1-second intervals but may
immediately revert to 2-second interval movements.
Charge in accordance with the estimated required charging time.
The figures in the table are for reference only.
The actual required charging time may differ depending on the model.
1.Pull out the crown to the 2nd click position when the second
hand reaches the 60 seconds position.
2.Turn the crown to set the current time.
3.Push the crown in to the normal (0 click) position while listening to
a time signal.
1.Pull out the crown to the 1st click position.
Do not set the calendar while the hands are in the time range below.
9:00 p.m. to 1:00 a.m.
The calendar will switch in this time range.
If the calendar is set in this condition, the calendar may not
switch the next day.If you want to set the calendar, move the
hands out of this time range.
2.Turn the crown clockwise to set the date.
3.Push the crown in to the normal (0 click) position.
The date must be corrected for short months.
Set the date to the "1st" when the date becomes the 1st of the
next month.
(A short month is a month with fewer than 31 days.)
The stopwatch on this product can measure up to 60 minutes in
1/5-second units.
The measured stopwatch time is indicated by the stopwatch
1/5-second hand in the center and the minute hand at 6 o'clock position.
Offers split time measurements (measurement of time at
midpoints/measurement of timings for two people).
Automatically stops and resets when 60 minutes have elapsed.
Use the stopwatch while the watch is adequately charged.
The stopwatch is unavailable when the energy depletion warning function
has activated (2-second interval movement).
If 2-second interval movement starts during stopwatch operation, the
stopwatch hands are reset to the 0 minute 0 second position.
The stopwatch is operated by the S1 and S2 buttons.
Start measurement when the stopwatch hands indicate 0
minutes and 0 seconds. Reset the stopwatch if the hands
do not indicate 0 minutes and 0 seconds.
How to Reset the Stopwatch
Normal
1.
Start
2.
Stop
3.
Restart
Indicates that serious injury or death could occur if this
is ignored and this product is handled incorrectly.
Indicates that injury or damage to property could occur
if this is ignored and this product is handled incorrectly.
Provides supplementary explanations and reference
information.
When using the product, some points must be observed in order to
protect the product and ensure safety of the user.
attached to the product. The same can be
found on the following homepage.
Some points should be observed to ensure prolonged use of your
purchased product. Please see the homepage.
This product is a solar-charged watch.
Solar Powered
The light received by the solar cell is converted into electrical energy
to power the watch.
See hear Charging Method Estimated Required Charging Time
Energy Depletion Warning Function
This watch shows the date in addition to showing the time (hour,
minute, and second).
See hear How to Set the Time How to Set the Calendar
The stopwatch can measure up to 60 minutes in 1/5-second
units.
See hear How to Use the Stopwatch
Reference Position Adjustment of Stopwatch Hands
The solar cell is located below the dial.
The design of the dial and position of the crown may differ depending
on the model.
Drive system
Crystal frequency
Wearing accuracy
(average monthly deviation)
Watch display
Additional
functions
Operating
temperature range
Batteries used
Operation duration
from full charge
Magnetic
resistance
Water resistance
Stepper motor
32 ,168Hz oscillations per second
±20 seconds
(When worn on the arm at 5°C to 35°C.
Hours, minutes, and seconds(hand movement
in 1-second intervals)/24-hour hand/date
Stopwatch function
1/5-second hand (hand movement in
1/5-second intervals, 60 seconds/revolution)
Minute hand (hand movement in 1-minute
intervals, 60 minutes/revolution)
Energy depletion warning function
Overcharging prevention mechanism
-5°C to +50°C
1 secondary battery
Approx. 6 months
( When the stopwatch is used no more than 1 hour a day.)
The water resistance performance is indicated on the case back.
A watch with ANTIMAG. I indicated on it is a type 1 antimagnetic
watch that maintains performance when moved close (about 5 cm)
a device that generates a magnetic field.
The water resistance performance is indicated on the case back.
A watch with WATER RESISTANT indicated on it has enhanced
water resistance performance.
Product specifications are subject to change without notice for
Be sure to expose the dial to light (recharge the watch) on a regular
basis. This product is powered by solar charging.
Leaving the watch for a long time in a dark place where it is not
charging may result in a low energy level.
Charging Method
The energy level is low if the second hand does not move in
continuous 1-second intervals. Adequately charge the watch.
Energy Depletion Warning Function
Energy Depletion Warning Function
T
wo-second interval movement indicates movement of the second
hand in 2-second (2-unit) intervals.
The second hand moves in 2-second intervals when the energy level is low.
When the second hand moves like this, the watch is likely to stop within
about one week. Adequately charge in accordance with the estimated
required charging time.
See hear Reference Position Adjustment of Stopwatch Hands
The second hand stops.
If the stopwatch is operating, it is reset.
The stopwatch hands return to the 0
minute 0 second position.
The 24-hour hand is synchronized with the hour hand.
When setting the time on a watch with a calendar, take care not
to mistake a.m. and p.m. Turn the crown in the direction that the
hands move. It is "a.m." when the date switches.
To set the time accurately, advance the minute hand by about
4 or 5 minutes and then return it to the current time.
TIP
The position of the calendar may
differ depending on the model.
Date correction at end of month
TIP
Press S1.
The stopwatch hands start to
move. (Measurement)
Press S1 during measurement.
The stopwatch hands stop and
indicate the measured time.
Press S2 while the stopwatch
is stopped.
The stopwatch hands return to
the 0 minute 0 second position.
The crown of this watch
can be pulled out to two
Illumina
nce (lx)
700
3,000
10,000
100,000
Light source
Environment Full charge
Continuous
1-second interval
movement
One day's
operation
Required charging time
Fluorescent
light
Sunlight
General office
30 W 20
Cloudy
Clear sky
Approx. 65
hours
Approx. 5
hours
Approx. 35
hours
Approx. 8
hours
Approx. 2.5
hours
Approx. 1
hour
Approx. 90
minutes
Approx. 20
minutes
Approx. 6
minutes
Approx. 2
minutes
2
Approx. 18
hours
Caution
Fluorescent
light
Sunlight
Caution
Warinig
Caution
TIP
TIP
TIP
Reference Position Adjustment of Stopwatch Hands
System Reset
1.Start
2.Stop
5.Reset
3.Restart
4.Stop
Press S1 while the stopwatch
is stopped.
The stopwatch hands start to
move again. (Restarted
measurement)
Press S1.
The stopwatch hands start to
move. (Measurement)
Press S1 during measurement.
The stopwatch hands stop and
indicate the measured time.
Press S1 during the restarted
measurement.
The stopwatch hands stop and
indicate the cumulative measured
time.
Press S2 while the stopwatch
is stopped.
The stopwatch hands return to
the 0 minute 0 second position.
1.Start
2.Split
find out the time at the midpoint
5.Reset
3.Cancel split
while started
4.Stop
Press S2 again.
The stopwatch hands fast-forward
to the currently measured time
and then start to move again.
(Restarted measurement)
The stopwatch hands stop and
indicate the current elapsed time.
(Split time display)
The time measurement continues
internally.
Press S1 during the restarted
measurement.
The stopwatch hands stop and
indicate the measured time.
(Split time display)
Press S2 while the stopwatch
is stopped.
The stopwatch hands return to
the 0 minute 0 second position.
Step 3 (restart) and step 4 (stop) can be repeated as many times
as you want.
Measurement of timings for two
1.Start
2.Split
when first person reaches goal
5.Reset
3.Split stop
when second person reaches goal
4.Cancel split stop
while stopped
Press S1 during split measurement.
Internal time measurement stops.
The stopwatch hands continue to
indicate the time for the first
person.
Press S2 while the stopwatch is
in the split stop state.
The stopwatch hands fast-forward
and indicate the time for the
second person.
Press S2 while the stopwatch
is stopped.
The stopwatch hands return to
the 0 minute 0 second position.
How to Reset the Stopwatch
During measurement [stopwatch hands moving]
Press S1. → Stop
 2 Press S2. → Reset
During split time display (internal measurement) [stopwatch hands stopped]
Press
S2. Measurement starts again after the stopwatch
hands fast-forward
 2 Press S1. → Stop
 3. Press S2. → Reset
During split time display (measurement stopped)
[stopwatch hands stopped]
 1
Press S2. → Stops after the stopwatch hands
fast-forward
 2
Press S2. → Reset
If the stopwatch hands do not return to the 0 minute 0 second position
when the stopwatch is reset, reference position adjustment is required.
Reference Position Adjustment of Stopwatch Hands
Troubleshooting
To ensure accurate measurement, if the reference position of the
stopwatch hands is misaligned, adjust the reference position.
After the reference position adjustment,t is necessary to set the
time.
1.
Pull out the crown to the 2nd click position when the second
hand reaches the 60 seconds position.
2.
Press and hold S1 for about 2 seconds. (Reference
position
adjustment mode)
The second hand stops.
The stopwatch 1/5-second hand
and minute hand return to
The stopwatch minute hand
(hand being adjusted) turns one
revolution.
5.
Press S2 to set the stopwatch 1/5-second hand to the zero
position. The details are the same as in step 3.
If the watch operates abnormally or does not move continuously
in 1-second intervals even after adequate charging, perform the
following operations to restore normal movement.
After the system reset, adjust the reference position of the
stopwatch and the time and calendar before use.
1.Pull out the crown to the 2nd click position.
2.Press the S1 and S2 buttons at the same time for about
2 seconds and then release them.
3.
Push the crown in to the normal (0 click) position.
The second hand stops.
The second hand starts to
move.The second hand starts
to move.
Second hand has stopped
Second hand moves in
2-second intervals
Energy level is low Charge the battery
Charging Method
Second hand does not
move continuously in
1-second intervals after
charging
Incident light is
too weak
Charging time is
too short
Stopwatch hands
deviated from the
reference position
Adjust the reference position
Reference Position
Adjustment of Stopwatch Hands
Abnormal movement
Reset the system
System Reset
Symptom
Step 2 (split) and step 3 (cancel split) can be repeated as many
times as you want.
TIP
Press S1.
The stopwatch hands start to
move. (Measurement)
Press S2 during measurement.
The stopwatch hands stop and
indicate the time for the first person.
The time measurement continues
internally. (Split measurement)
Press S1.
The stopwatch hands start to
move. (Measurement)
Remedy and reference
Possible
If the reference position is misaligned,
the stopwatch hands will not return to
the 0 minute 0 second position.
TIP
3.Press S2 to set the stopwatch minute hand to the zero position.
Press S2 once to advance the
stopwatch minute hand by one step.
Press and hold S2 to fast-forward
the hand.
The stopwatch 1/5-second hand
(hand being adjusted) turns one
revolution.
4.
Press and hold S1 for about 2 seconds. (Switching of the
reference position adjustment mode)
By repeating steps 2 to 5, you can readjust the stopwatch
hands to the zero position as many times as you like.
6.
After adjusting the stopwatch hands to the zero position, set the
time. How to Set the Time
This initializes the watch
internal system and returns it
to the normal state.
The energy level is low if the second hand moves in 2-second
intervals after the system reset. Charge the battery until the second
hand moves continuously in 1-second intervals.
4.Once the second hand moves continuously in 1-second
intervals, adjust the stopwatch hands to the reference position.
Next, set the time and calendar.
Reference Position Adjustment of Stopwatch Hands
How to Set the Time
How to Set the Calendar
Stopped [stopwatch hands stopped]
  Press S2. Reset
©2023 Seiko Epson Corporation
U79905080 (Rev.1.1 EN)
Charge in accordance
with the estimated required
charging time
Estimated Required
Charging Time
If the problem persists,
reset the system.
System Reset
If resetting the system does not solve the problem, the watch may be
defective. Contact the customer service center (TEL: 042-847-3380).
The stopwatch reset procedure differs according to the time
measurement state. Press the S2 button while the stopwatch is
stopped to reset it.
The system inside
the watch has
become unstable
Hands do not return to
the 0 minute 0 second
position when the
stopwatch is reset
TIP
TIP
TIP
Caution
  • Page 1 1
  • Page 2 2

Epson RZ-TX0101N User guide

Category
Watches
Type
User guide

Epson RZ-TX0101N is a versatile device that combines printing, copying, and scanning functions. With its compact size and Wi-Fi connectivity, it's ideal for home or small office use. Print high-quality documents and photos with Epson's PrecisionCore technology, and easily copy or scan documents with the automatic document feeder. The RZ-TX0101N also supports mobile printing via the Epson iPrint app, making it convenient to print from smartphones or tablets.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI