3CCT Switch
BWSW14318 BWSW14324
BWSW14318 BWSW14324
Oct. 2022 2 Oct. 2022 3
Wall Plate
Driver
Mounting Screw
Wire Connector
Plastic Anchor
Junction Box
Ground Wire
Black wire
White wire
Fixture
Rubber Gasket
Anchor Screw
Junction Box
Screw
1. Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
3. Remove the mounting screw (B) and rubber gasket (C) from the xture.
4. The lamp can switch between three color temperatures (3000K-3500K-4000K), which can be adjusted toyour preference with the switch in the
xture (Fig.4).
5. Drill holes in the wall aligned with the key holes located on the wall plate,insert the plastic anchor(D).
6. Secure wall plate to the junction box using standard junction box screws that comes with the junction box, fasten it to the wall using
a
nchor Screw
(E).
(i) It is recommended to use only original junction box screws or replacements provided by junction box manufacturer.
(ii) The side of the mounting plate marked “GND” must face out.
7. Connect the driver’ s input wires to the junction box wires as shown in Fig. 2 using wire connectors (A) provided. Ensure wire connectors are secure.
Connect the xture’s ground wire to the ground in the junction box; this will be either a green wire or a bare copper wire. After xture is wired to
house wires, tuck wires carefully inside the junction box.
8. Place the xture over the mounting back plate and secure it with mounting screws (B) and the rubber gasket (C).
9. To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline the outside
of xture back plate where it meets the wall. Leave a space at the bottom to allow moisture to escape(Fig.4)
Coastal conditions may cause mineral and residue build-up on the xture. We recommend that customers in coastal
areas clean all external surfaces of the xture once every two weeks with a wet cloth.
B
A
D
E
C