INSTALLATION INSTRUCTIONS
20" (50.8 CM) FREESTANDING ELECTRIC RANGE
with Standard Clean Oven
INSTRUCCIONES DE INSTALACIÓN
ESTUFA ELÉCTRICA AUTÓNOMA DE 20" (50,8 CM)
con horno de limpieza estándar
Table of Contents/Índice
RANGE SAFETY .............................................................................2
INSTALLATION REQUIREMENTS................................................2
Tools and Parts ............................................................................2
Location Requirements................................................................3
Electrical Requirements ...............................................................4
INSTALLATION INSTRUCTIONS..................................................5
Unpack Range..............................................................................5
Install Anti-Tip Bracket.................................................................6
Electrical Connection ...................................................................7
Verify Anti-Tip Bracket Location ................................................12
Level Range................................................................................12
Complete Installation .................................................................12
Check Operation ........................................................................12
SEGURIDAD DE LA ESTUFA.......................................................13
REQUISITOS DE INSTALACIÓN.................................................14
Piezas y herramientas ................................................................14
Requisitos de ubicación.............................................................14
Requisitos eléctricos..................................................................15
INSTRUCCIONES DE INSTALACIÓN.........................................17
Desempaque la estufa ...............................................................17
Instalación del soporte anti-vuelco............................................17
Conexión eléctrica......................................................................19
Verificación de la ubicación del soporte anti-vuelco.................24
Nivelación de la estufa ...............................................................24
Complete la instalación..............................................................24
Verifique el funcionamiento........................................................24
IMPORTANT:
Save for local electrical inspector's use.
IMPORTANTE:
Guarde para tenerlas a disposición del inspector de electricidad local.
W10175654B
2
RANGE SAFETY
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Parts supplied
Check that all parts are included.
Anti-tip bracket must be securely mounted to subfloor. Thickness
of flooring may require longer screws to anchor bracket to
subfloor. Longer screws are available from your local hardware
store.
You can be killed or seriously injured if you don't immediately
You
can be killed or seriously injured if you don't
follow
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
follow instructions.
instructions.
DANGER
WARNING
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death or serious burns to children and adults.
Tape measure
Flat-blade screwdriver
Phillips screwdriver
Level
Hammer
Hand or electric drill
Wrench or pliers
Marker or pencil
Masking tape
Wire strippers
³⁄₈" nut driver
¹⁄₈" (3.2 mm) drill bit
(for wood floors)
³⁄₁₆" (4.8 mm) carbide-
tipped masonry drill bit
(for concrete/ceramic
floors)
A. Anti-tip bracket
B. Plastic anchors (2)
C. #10 x 1½" screws (2)
B
A
C
3
Parts needed
If using a power supply cord:
A UL listed power supply cord kit marked for use with ranges.
The cord should be rated at 250 volts minimum, 40 amps or
50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm)
diameter connection opening and must end in ring terminals
or open-end spade terminals with upturned ends.
A UL listed strain relief.
Check local codes. Check existing electrical supply. See
“Electrical Requirements” section.
It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
It is the installer's responsibility to comply with installation
clearances specified on the model/serial rating plate. The
model/serial rating plate is located on under the left front
burner bowl.
The range should be located for convenient use in the
kitchen.
Recessed installations must provide complete enclosure of
the sides and rear of the range.
To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets.
Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
The floor anti-tip bracket must be installed. To install the anti-
tip bracket shipped with the range, see “Install Anti-Tip
Bracket” section.
Grounded electrical supply is required. See “Electrical
Requirements” section.
Contact a qualified floor covering installer to check that the
floor covering can withstand at least 200°F (93°C).
Use an insulated pad or ¼" (0.64 cm) plywood under range if
installing range over carpeting.
IMPORTANT: To avoid damage to your cabinets, check with your
builder or cabinet supplier to make sure that the materials used
will not discolor, delaminate or sustain other damage. This oven
has been designed in accordance with the requirements of UL
and CSA International and complies with the maximum allowable
wood cabinet temperatures of 194°F (90°C).
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280). When such standard is not
applicable, use the Standard for Manufactured Home
Installations, ANSI A225.1/NFPA 501A or with local codes.
Mobile home installations require:
When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing
the range is adequate as long as it conforms to the standards
listed above.
Four-wire power supply cord or cable must be used in a
mobile home installation. The appliance wiring will need to be
revised. See “Electrical Connection” section.
Product Dimensions
A. Model/serial rating plate
A
A. 36" (91.5 cm)
B. 19½" (49.5 cm)
C. 24½" (62.2 cm)
D. 42" (106.7 cm)
A
B
C
D
4
Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64.0 cm)
countertop depth, 24" (61.0 cm) base cabinet depth and
36" (91.4 cm) countertop height.
If the cabinet depth is greater than 24" (61.0 cm), the oven frame
must extend beyond cabinet fronts by ½" (13.0 mm) minimum.
IMPORTANT: If installing a range hood or microwave hood
combination above the range, follow the range hood or
microwave hood combination installation instructions for
dimensional clearances above the cooktop surface.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal
cabinet is covered by not less than ¼" (0.64 cm) flame retardant
millboard covered with not less than No. 28 MSG sheet steel,
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an uncovered wood or metal cabinet.
Electrical Requirements
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate and wire gauge is in accordance
with local codes.
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
WARNING: Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check with a
qualified electrician or service technician if you are in doubt as to
whether the appliance is properly grounded. Do not modify the
power supply cord plug. If it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
Electrical Connection
To properly install your range, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
Range must be connected to the proper electrical voltage
and frequency as specified on the model/serial number rating
plate. The model/serial number rating plate is located under
the front left burner bowl. Refer to the figure in the “Location
Requirements” section.
This range is manufactured with the neutral terminal
connected to the cabinet. Use a 3-wire UL listed, 40- or 50-
amp power supply cord (pigtail) (see Range Rating chart
below). If local codes do not permit ground through the
neutral, use a 4-wire power supply cord rated at 250 volts,
40 or 50 amps and investigated for use with ranges.
*The NEC calculated load is less than the total connected load
listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with
kit. For 50-amp rated cord kits, use kits that specify use with a
nominal 1³⁄" (34.93 mm) diameter connection opening.
A circuit breaker is recommended.
The range can be connected directly to the circuit breaker
box (or fused disconnect) through flexible or nonmetallic
sheathed, copper or aluminum cable. See “Electrical
Connection.”
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that
the range can be moved if servicing is ever necessary.
A UL listed conduit connector must be provided at each end
of the power supply cable (at the range and at the junction
box).
Wire sizes and connections must conform with the rating of
the range (40 amps).
The wiring diagram is located on the underside of the storage
drawer or below the warming drawer in a clear plastic bag.
A. 18" (45.7 cm) min. clearance
upper side cabinet to
countertop
B. 13" (33.0 cm) max. upper
cabinet depth
C. 20" (50.8 cm) min. cabinet
opening width
D. 20
¹⁄₈
" (51.1 cm) opening width
E. 5" (12.7 cm) min. countertop
space to side wall or other
combustible material
F. For minimum clearance to top
of cooktop, see NOTE.
G. Wall receptacle - 8" (20.3 cm)
from either cabinet,
H. 5½" (14.0 cm) max. from floor.
Locate 120/240-volt
receptacle in shaded area.
A
B
C
D
E
F
G
H
G
Range Rating* Specified Rating of
Power Supply Cord Kit
and Circuit Protection
120/240 Volts 120/208 Volts Amps
8.0 - 16.5 KW
16.6 - 22.5 KW
6.0 - 12.5 KW
12.6 - 18.5 KW
40 or 50**
50
5
If connecting to a 4-wire system:
This range is manufactured with the ground connected to the
neutral by a link. The ground must be revised so the green
ground wire of the 4-wire power supply cord is connected to the
cabinet. See “Electrical Connection.”
Grounding through the neutral conductor is prohibited for new
branch-circuit installations (1996 NEC); mobile homes; and
recreational vehicles, or an area where local codes prohibit
grounding through the neutral conductor.
When a 4-wire receptacle of NEMA Type 14-50R is used, a
matching UL listed, 4-wire, 250-volt, 40-amp, range power
supply cord (pigtail) must be used. This cord contains 4 copper
conductors with ring terminals or open-end spade terminals with
upturned ends, terminating in a NEMA Type 14-50P plug on the
supply end.
The fourth (grounding) conductor must be identified by a green or
green/yellow cover and the neutral conductor by a white cover.
Cord should be Type SRD or SRDT with a UL listed strain relief
and be at least 4 ft (1.22 m) long.
The minimum conductor sized for the copper 4-wire power
cord are:
40-amp circuit
2 No.-8 conductors
1 No.-10 white neutral
1 No.-8 green grounding
If connecting to a 3-wire system:
Local codes may permit the use of a UL listed, 3-wire,
250 volt, 40-amp range power supply cord (pigtail). This cord
contains 3 copper conductors with ring terminals or open-end
spade terminals with upturned ends, terminating in a NEMA Type
10-50P plug on the supply end. Connectors on the appliance end
must be provided at the point the power supply cord enters the
appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.
INSTALLATION INSTRUCTIONS
Unpack Range
1. Do not use oven door handle to lift or move the range.
2. Remove shipping materials, tape and film from range. Keep
cardboard bottom under range. Remove oven racks and
parts package from inside oven.
3. Take 4 cardboard corners from the carton. Stack one
cardboard corner on top of another. Repeat with the other
2 corners. Place them lengthwise on the floor behind the
range to support the range when it is laid on its back. Using
2 or more people, firmly grasp the range and gently lay it on
its back on the cardboard corners.
4. Pull cardboard bottom firmly to remove.
5. Use a wrench or pliers to loosen the leveling legs. Adjust the
leveling legs to the correct height. Leveling legs can be
loosened to add up to a maximum of 1" (2.5 cm). A maximum
of ³⁄₁₆" (5.0 mm) is needed to engage the anti-tip bracket.
NOTE: If height adjustment is made when range is standing,
tilt the range back to adjust the front legs, then tilt forward to
adjust the rear legs.
6. Place cardboard or hardboard in front of range. Using 2 or
more people, stand range back up onto cardboard or
hardboard.
4-wire receptacle (14-50R)
3-wire receptacle (10-50R)
WARNING
Excessive Weight Hazard
Use two or more people to move and install range.
Failure to do so can result in back or other injury.
A. Cardboard shipping base
A
6
Install Anti-Tip Bracket
Contact a qualified floor covering installer for the best procedure
for drilling mounting holes through your type of floor covering.
Before moving range, slide range onto shipping base, cardboard
or hardboard.
1. Remove template from the anti-tip bracket kit (found inside
the oven cavity).
2. Place template on the floor in cabinet opening so that left
edge is against cabinet and top edge is against rear wall,
molding or cabinet. 3
3. Tape template into place.
4. If countertop is not flush with cabinet opening edge, align
template with overhang.
If cabinet opening is wider than that specified in the “Location
Requirements” section, adjust template so range will be
centered in cabinet opening.
5. To mount anti-tip bracket to wood floor, drill two ¹⁄₈" (3.2 mm)
holes at the positions marked on the bracket template.
Remove template from floor.
To mount the anti-tip bracket to a concrete or ceramic floor,
use a ³⁄₁₆" (4.8 mm) masonry drill bit to drill 2 holes at the
positions marked on the bracket template. Remove the
template from the floor.
6. Tap plastic anchors into holes with a hammer.
7. Align the anti-tip bracket holes with the holes in the floor.
Fasten the anti-tip bracket with the screws provided.
Depending on the thickness of your flooring, longer screws
may be necessary to anchor the bracket to the subfloor.
Longer screws are available from your local hardware store.
8. Move the range close to the opening to allow for electrical
connections to be made. Remove the shipping base,
cardboard or hardboard from under the range.
9. Use a wrench or pliers to lower the front leveling legs one-half
turn.
10. Adjust the leveling legs to the correct height. Leveling legs
can be loosened to add up to a maximum of 1" (2.5 cm). A
minimum of ³⁄₁₆" (5.0 mm) is needed to engage the anti-tip
bracket.
11. Move the range into final location making sure the rear
leveling leg slides into the anti-tip bracket.
12. If installing the range in a mobile home, you must secure the
range to the floor. The method of securing the range must
conform to the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280 (formerly the Federal
Standard for Mobile Home Construction and Safety, Title 24,
HUD Part 280). When such standard is not applicable, use
the Standard for Manufactured Home Installations, ANSI
A225.1/NFPA 501 A or with local codes.
13. Continue installing your range using the following installation
instructions.
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
A. Rear leveling leg
B. Front leveling leg
A
B
7
Electrical Connection
Power Supply Cord Direct Wire
1. Disconnect power
2. Remove the terminal block cover screws located on the back
of the range. Pull cover down and toward you to remove
cover.
3. Add strain relief.
Style 1: Power supply cord strain relief
Assemble a UL listed strain relief in the opening.
Feed the power supply cord through the strain relief on
the cord/conduit plate on bottom of range. Allow enough
slack to easily attach the wiring to the terminal block.
Tighten strain relief screw against the power supply cord.
Style 2: Direct wire strain relief
Use Phillips screwdriver to remove screws and rotate/
conduit plate 180º.
Position cord/conduit plate as shown in the following
illustration.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
A. Hold-down screws
B. Terminal block cover
A. UL listed strain relief - large opening
B. Small opening
A
B
A. Large opening
B. Small opening
A. Small opening
B. Large opening
A
B
A
B
8
Replace cord/conduit plate and insert screws.
Assemble a UL listed conduit connector in the opening.
Feed the flexible conduit through the strain relief, allowing
enough slack to easily attach wiring to the terminal block.
Tighten strain relief screw against the flexible conduit.
4. Replace back panel and screws on rear of range.
5. Complete installation following instructions for your type of
electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
Electrical Connection Options
4-wire connection: Power Supply Cord
Use this method for:
New branch-circuit installations (1996 NEC)
Mobile homes
Recreational vehicles
In an area where local codes prohibit grounding through the
neutral
1. Part of metal ground strap must be cut out and removed.
2. Use Phillips screwdriver to remove the ground-link screw
from the back of the range. Save the ground-link screw and
the end of the ground-link under the screw.
A. Small opening
B. Large opening
A. Removable retaining nut - small opening
B. Conduit connector
C. Large opening
A
B
A
B
C
If your home has: And you will be
connecting to:
Go to Section:
4-wire receptacle
(NEMA type 14-50R)
A UL listed,
250-volt
minimum,
40-amp, range
power supply
cord
4-wire connection:
Power supply cord
4-wire direct A circuit breaker
box or fused
disconnect
4-wire connection:
Direct wire
3-wire receptacle
(NEMA type 10-50R)
A UL listed,
250-volt
minimum,
40-amp, range
power supply
cord
3-wire connection:
Power supply cord
3-wire direct A circuit breaker
box or fused
disconnect
3-wire connection:
Direct wire
A. Metal ground strap
B. Discard
C. Ground-link screw
(12.7 cm)
5"
3"
(7.6 cm)
1"
(2.5 cm)
A
B
C
9
3. Feed the power supply cord through the strain relief on the
cord/conduit plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.
4. Use Phillips screwdriver to connect the green ground wire
from the power supply cord to the range with the ground-link
screw. The ground wire must be attached first.
5. Use ³⁄₈" nut driver to connect the neutral (white) wire to the
center terminal block post with one of the 10–32 hex nuts.
6. Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with 10-32 hex nuts.
7. Securely tighten hex nuts.
NOTE: For power supply cord replacement, only use a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 1³⁄₈" (3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges.
8. Replace terminal block access cover.
3-wire connection: Power Supply Cord
Use this method only if local codes permit connecting chassis
ground conductor to neutral wire of power supply cord.
1. Feed the power supply cord through the strain relief on the
cord/conduit plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.
2. Use ³⁄₈" nut driver to connect the neutral (white) wire to the
center terminal block post with one of the 10–32 hex nuts.
3. Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with 10-32 hex nuts.
4. Securely tighten hex nuts.
NOTE: For power supply cord replacement, only use a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 1³⁄₈" (3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges.
5. Replace terminal block access cover.
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Power supply cord wires - large opening
E. Small opening
A. 10–32 hex nut
B. Ground-link screw
C. Line 1 (black)
D. Green ground wire
E. Neutral (center) wire
F. Line 2 (red)
A
B
C
D
E
A
B
C
F
D
E
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Power supply cord wires - large opening
E. Small opening
A. 10–32 hex nut
B. Line 1 (black)
C. Ground-link screw
D. Neutral (white) wire
E. Line 2 (red)
A
B
C
D
E
A
B
C
D
E
10
Direct Wire Installation: Copper or Aluminum Wire
This range may be connected directly to the circuit breaker box
or fused disconnect. Depending on your electrical supply, make
the required 3-wire or 4-wire connection.
1. Strip outer covering back 3" (7.6 cm) to expose wires. Strip
the insulation back 1" (2.5 cm) from the end of each wire.
2. Allow enough slack in the wire to easily attach the wiring
terminal block.
3. Complete electrical connection according to your type of
electrical supply (4-wire or 3-wire connection).
4-wire Connection: Direct Wire
Use this method for:
New branch-circuit installations (1996 NEC)
Mobile homes
Recreational vehicles
In an area where local codes prohibit grounding through the
neutral
1. Part of metal ground strap must be cut out and removed.
2. Use Phillips screwdriver to remove the ground-link screw
from the back of the range. Save the ground-link screw and
the end of the ground-link under the screw.
3. Pull the conduit through the strain relief on cord/conduit plate
on bottom of range. Allow enough slack to easily attach
wiring to the terminal block.
4. Attach terminal lugs to line 1 (black), neutral (white), and line 2
(red) wires. Loosen (do not remove) the set screw on the front
of the terminal lug and insert exposed wire end through
bottom of terminal lugs. Securely tighten set screw to torque
as shown in the following Bare Wire Torque Specifications
chart.
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)
5. Use Phillips screwdriver to connect the bare (green) ground
wire to the range with the ground-link screw. The ground wire
must be attached first and must not contact any other
terminal.
A. Metal ground strap
B. Discard
C. Ground-link screw
3"
(7.6 cm)
1"
(2.5 cm)
A
B
C
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Line 2 (red) wire
E. Neutral (white) wire
F. Line 1 (black) wire
G. Bare (green) ground wire
A. Terminal lug
B. Set screw
C. Line 1 (black) wire
D. Neutral (white) wire
E. Line 2 (red) wire
Wire Awg Torque
8 gauge copper 25 lbs-in. (2.8 N-m)
6 gauge aluminum 35 lbs-in. (4.0 N-m)
A
B
C
D
E
G
F
A
B
C
DE
11
6. Use ³⁄₈" nut driver to connect the neutral (white) wire to the
center terminal block post with one of the 10–32 hex nuts.
7. Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with 10-32 hex nuts.
8. Securely tighten hex nuts.
9. Replace terminal block access cover.
3-wire connection: Direct Wire
Use this method only if local codes permit connecting ground
conductor to neutral supply wire.
1. Pull the conduit through the strain relief on cord/conduit plate
on bottom of range. Allow enough slack to easily attach the
wiring to the terminal block.
2. Attach terminal lugs to line 1 (black), bare (green) ground, and
line 2 (red) wires. Loosen (do not remove) the set screw on the
front of the terminal lug and insert exposed wire end through
bottom of terminal lugs. Securely tighten set screw to torque
as shown in the following Bare Wire Torque Specifications
chart.
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)
3. Use ³⁄₈" nut driver to connect the bare (green) ground wire to
the center terminal block post with one of the 10–32 hex nuts.
4. Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with 10-32 hex nuts.
5. Securely tighten hex nuts.
6. Replace terminal block access cover.
A. 10–32 hex nut
B. Line 1 (black)
C. Bare (green) ground wire
D. Ground-link screw
E. Neutral (white) wire
F. Line 2 (red)
G. Terminal lug
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Line 2 (red) wire
E. Bare (green) ground wire
F. Line 1 (black) wire
B
A
G
E
C
D
F
A
B
C
D
E
F
A. Terminal lug
B. Set screw
C. Line 1 (black) wire
D. Bare (green) ground wire
E. Line 2 (red) wire
Wire Awg Torque
8 gauge copper 25 lbs-in. (2.8 N-m)
6 gauge aluminum 35 lbs-in. (4.0 N-m)
A. 10–32 hex nut
B. Line 1 (black)
C. Ground-link screw
D. Bare (green) ground wire
E. Line 2 (red)
F. Te rmina l lu g
A
B
C
DE
B
F
A
E
D
C
12
Verify Anti-Tip Bracket Location
1. Make sure the anti-tip bracket is installed:
Look for the anti-tip bracket securely attached to the floor.
Slide the range back so the rear range foot is under the anti-
tip bracket.
Level Range
1. Place rack in oven.
2. Place level on rack and check levelness of range, first side to
side; then front to back.
3. If range is not level, pull range forward until rear leveling leg is
removed from the anti-tip bracket.
4. Use ³⁄₈" drive ratchet and slip-joint pliers to adjust leveling
legs up or down until range is level.
5. Push range back into position.
6. Check that rear leveling leg is engaged in anti-tip bracket.
NOTE: Range must be level for satisfactory baking performance.
Complete Installation
1. Check that all parts are now installed. If there is an extra part,
go back through the steps to see which step was skipped.
2. Check that you have all of your tools.
3. Dispose of/recycle all packaging materials.
4. Check that the range is level. See “Level Range.”
5. Use a mild solution of liquid household cleaner and warm
water to remove waxy residue caused by shipping material.
Dry thoroughly with a soft cloth.
6. For range use and cleaning, read the range Use and Care
Guide.
7. Turn on surface burners and oven.
If range does not operate, check the following:
Household fuse is intact and tight; or circuit breaker has not
tripped.
Electrical supply is connected.
See “Troubleshooting” in the Use and Care Guide.
Check Operation
Check the operation of the cooktop elements:
1. Push in and turn each surface element control knob to “HI”
position.
Check the operation of the cooktop elements and indicator
lights.
2. Turn the control knob to the “OFF” position.
Check operation of the oven elements:
1. Set the oven temperature control to 350°F.
The bottom element should glow red and the “OVEN ON”
indicator light should be on. The upper element should
become hot but not glow red. The “OVEN ON” indicator light
goes off when the oven is preheated.
2. Set the oven temperature control to “BROIL.”
The upper element should glow red and the “OVEN ON”
indicator light should be on.
3. Turn the control knob to the “OFF” position.
A. Surface indicator light
A. Oven indicator light
L
O
2
3
4
5
6
7
8
9
H
I
OFF
SURFACE
RIGHT REAR
RIGHT FRONT
L
O
2
3
4
5
6
7
8
9
H
I
OFF
A
L
O
2
3
4
5
6
7
8
9
H
I
OFF
OV EN
13
SEGURIDAD DE LA ESTUFA
Si no sigue las instrucciones de inmediato, usted puede
morir o sufrir una lesión grave.
Si no sigue las instrucciones, usted puede morir o sufrir
una lesión grave.
Todos los mensajes de seguridad le dirán el peligro potencial, le dirán cómo reducir las posibilidades de sufrir una lesión y lo que
puede suceder si no se siguen las instrucciones.
Su seguridad y la seguridad de los demás es muy importante.
Hemos incluido muchos mensajes importantes de seguridad en este manual y en su electrodoméstico. Lea y obedezca siempre
todos los mensajes de seguridad.
ADVERTENCIA
PELIGRO
Este es el símbolo de advertencia de seguridad.
Este símbolo le llama la atención sobre peligros potenciales que pueden ocasionar la muerte o una lesión a
usted y a los demás.
Todos los mensajes de seguridad irán a continuación del símbolo de advertencia de seguridad y de la palabra
“PELIGRO” o “ADVERTENCIA”. Estas palabras significan:
Peligro de Vuelco
Un niño o un adulto puede volcar accidentalmente la estufa y resultar muerto.
Conecte el soporte anti-vuelco a la pata trasera de la estufa.
Si traslada de lugar la estufa, vuelva a conectar el soporte anti-vuelco.
No seguir estas instrucciones puede ocasionar la muerte o quemaduras graves en niños y
adultos.
ADVERTENCIA
14
REQUISITOS DE INSTALACIÓN
Piezas y herramientas
Reúna las herramientas y piezas necesarias antes de comenzar
la instalación. Lea y siga las instrucciones provistas con
cualquiera de las herramientas enlistadas aquí.
Herramientas necesarias
Piezas suministradas
Verifique que estén todas las piezas.
El soporte anti-vuelco debe estar montado en el contrapiso
firmemente. Según el espesor del piso, es posible que sea
necesario utilizar tornillos más largos para sujetar el soporte al
contrapiso. Puede conseguir tornillos más largos en su ferretería
local.
Piezas necesarias
Si emplea un cable de suministro eléctrico:
Un cable de suministro de energía que esté en la lista de UL,
para ser usado con estufas. El cable deberá tener una
clasificación de 250 voltios como mínimo, 40 ó 50 amperios,
marcado para ser usado con una abertura de conexión
nominal con un diámetro de 1³⁄₈" (3,5 cm), y deberá terminar
en terminales de anillo o terminales de horquilla abiertas, con
los extremos hacia arriba.
Un protector de cables que esté en la lista de UL.
Verifique los códigos locales. Verifique el suministro eléctrico
existente. Vea la sección “Requisitos eléctricos”.
Es recomendable que todas las conexiones eléctricas sean
hechas por un instalador eléctrico competente autorizado.
Requisitos de ubicación
IMPORTANTE: Observe todos los códigos y reglamentos
aplicables.
Es la responsabilidad del instalador cumplir con los espacios
de instalación especificados en la placa con la clasificación
de modelo/serie. La placa indicadora de modelo/serie está
ubicada debajo del tazón del quemador delantero izquierdo.
Deberá colocarse la estufa en un lugar conveniente de la
cocina para su uso.
Las instalaciones empotradas deberán proveer un recinto
cerrado de los lados y la parte posterior de la estufa.
Para eliminar el riesgo de quemaduras o incendio al tocar
unidades con la superficie demasiado caliente, debe
evitarse el uso de armarios de almacenaje encima de las
unidades. Si van a proveerse armarios, puede reducir el
riesgo instalando una capota de ventilación que se proyecte
horizontalmente un mínimo de 5" (12,7 cm) sobresaliendo de
la base de los armarios.
Deben usarse las dimensiones de la abertura del armario que
se muestran. Las dimensiones proporcionadas son los
espacios mínimos.
Debe instalarse el soporte anti-vuelco del piso. Para instalar
el soporte anti-vuelco enviado con la estufa, vea la sección
“Instalación del soporte anti-vuelco”.
Se requiere un suministro eléctrico conectado a tierra. Vea la
sección “Requisitos eléctricos”.
Póngase en contacto con un instalador calificado de
revestimiento de pisos para cerciorarse de que el
revestimiento del piso puede soportar por lo menos
200°F (93°C).
Use una almohadilla aislante o una madera laminada de
¼" (0,64 cm) debajo de la estufa si va a instalar la estufa
sobre una alfombra.
IMPORTANTE: Para evitar daños a sus armarios, verifique con el
constructor o distribuidor de armarios para asegurarse de que
los materiales que se usen no se descoloren, astillen ni sufran
ningún otro tipo de daño. Este horno ha sido diseñado de
acuerdo a los requisitos de UL y CSA International, y cumple con
las temperaturas máximas permitidas para armarios de madera
de 90°C (194°F).
Cinta para medir
Destornillador de hoja
plana
Destornillador Phillips
Nivel
Martillo
Taladro manual o
eléctrico
Llave de tuercas o pinzas
Marcador o lápiz
Cinta adhesiva protectora
Pelacables
Llave para tuercas de ³⁄₈"
Broca de ¹⁄₈" (3,2 mm)
(para pisos de madera)
Broca para albañilería con
punta de carburo de
³⁄₁₆" (4,8 mm) (para pisos
de hormigón/cerámica)
A. Soporte anti-vuelco
B. Sujetadores de plástico (2)
C. Tornillos #10 x 1½" (2)
B
A
C
A. Placa de clasificación de modelo/serie
A
15
Requisitos de instalación adicionales para las casas
rodantes
La instalación de esta estufa debe ajustarse al Estándar de
seguridad y construcción de casas fabricadas, Título 24 CFR,
Parte 3280 (anteriormente conocido como Estándar federal para
la seguridad y construcción de casas rodantes, Título 24, HUD
Parte 280). Cuando no sea aplicable ese estándar, use el
Estándar para instalaciones en casas fabricadas, ANSI A225.1/
NFPA 501A u obedezca los códigos locales.
Las instalaciones en casas rodantes necesitan:
Cuando se instale la estufa en una casa rodante, deberá
asegurarse al piso durante el transporte. Cualquier método
de fijación es adecuado en tanto cumpla con las normas
indicadas arriba.
Para una instalación en casa rodante, deberá usarse un cable
de suministro de energía de cuatro hilos. Deberá revisarse el
cableado del aparato. Vea la sección “Conexión eléctrica”.
Medidas del producto
Dimensiones del armario
Las dimensiones de la abertura del armario que se muestra son
para una profundidad de mostrador de 25" (64,0 cm),
profundidad del armario de la base de 24" (61 cm) y altura del
mostrador de 36" (91,4 cm).
Si la profundidad del armario es mayor de 24" (61,0 cm), deberá
extenderse el marco del horno más allá de los frentes del armario
por un mínimo de ½" (13,0 mm).
IMPORTANTE: Si va a instalar una campana para estufa o una
combinación microondas campana sobre la estufa, siga las
instrucciones de instalación incluidas con la campana para
estufa o la combinación microondas campana para las medidas
de espacio sobre la superficie de cocción.
NOTA: 24" (61,0 cm) mínimo cuando la base del armario de
madera o de metal esté protegida por cartón retardante a las
llamas de no menos de ¼" (0,64 cm), cubierto de lámina de acero
de no menos de acero inoxidable N° 28 MSG de
0,015" (0,4 mm), aluminio de 0,024" (0,6 mm) o cobre de
0,020" (0,5 mm).
30" (76,2 cm) de espacio mínimo entre la parte superior de la
plataforma de la superficie de cocción y la base de un armario de
madera o metal desprotegido.
Requisitos eléctricos
Si los códigos lo permiten y se emplea un alambre de conexión a
tierra separado, es recomendable que un instalador eléctrico
competente determine si la trayectoria de conexión a tierra es la
correcta y el calibre del cable está de acuerdo con los códigos
locales.
No use un cable eléctrico de extensión.
Asegúrese de que la conexión eléctrica y el tamaño del hilo sean
adecuados y de conformidad con el Código Nacional Eléctrico,
ANSI/NFPA 70 - última edición y con todos los códigos y
ordenanzas locales.
A. 36" (9,5 cm)
B. 19½" (49,5 cm)
C. 24½" (62,2 cm)
D. 42" (106,7 cm)
A
B
C
D
A. 18" (45,7 cm) de espacio
mínimo del lado superior del
armario al mostrador
B. 13" (33,0 cm) máximo de
profundidad del armario
superior
C. Ancho mínimo de la abertura
del armario 20" (50,8 cm)
D. Ancho de la abertura
20
¹⁄₈
" (51,1 cm)
E. Espacio mínimo del mostrador a la
pared lateral u otro material
combustible 5" (12,7 cm)
F. Para ver el espacio mínimo hasta
la parte superior de la superficie
de cocción, vea la NOTA.
G. Contacto de pared - 8" (20,3 cm)
desde cualquier armario
H. " (14,0 cm) máx. desde el piso.
Coloque el contacto de 120/240
voltios en el área sombreada.
A
B
C
D
E
F
G
H
G
16
Usted puede obtener una copia de todas las normas arriba
indicadas en:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
ADVERTENCIA: La conexión inadecuada del conductor a tierra
para el equipo puede resultar en un riesgo de choque eléctrico.
Si no está seguro de que la conexión a tierra del aparato sea la
adecuada, verifíquela con un electricista o técnico de servicio
competente. No modifique el enchufe del cable de suministro de
energía. Si no encaja en el contacto, consulte con un electricista
competente para instalar un contacto adecuado.
Conexión eléctrica
Para instalar la estufa adecuadamente, usted debe determinar el
tipo de conexión eléctrica que va a usar y seguir las
instrucciones que aquí se proveen para el caso.
La estufa debe estar conectada al voltaje eléctrico y
frecuencia apropiados, según se especifica en la placa de
clasificación del modelo/serie. La placa indicadora del
número de modelo/serie está ubicada debajo del tazón del
quemador delantero izquierdo. Vea la ilustración en la
sección “Requisitos de ubicación”.
Esta estufa fue fabricada con el terminal neutro conectado a
la carcasa. Use un cable de suministro eléctrico de 3 hilos,
aprobado por UL, de 40 ó 50 amperios (cable de cola de
cochino flexible) (vea la tabla de voltaje de la estufa a
continuación). Si los códigos locales no permiten hacer la
conexión a tierra a través del terminal neutro, use un cable de
suministro eléctrico de 4 hilos, de 250 voltios, 40 ó
50 amperios y que haya sido investigado para ser usado con
estufas.
*La carga calculada de NEC (Código Nacional Eléctrico, por sus
siglas en inglés) es menor que la carga conectada total que se
indica en la placa de clasificación de modelo/serie.
**Si se conecta a un circuito de 50 amperios, use un cable con
clasificación de 50 amperios con el juego. Para los juegos de
cable que tengan una clasificación de 50 amperios, use los
juegos en los cuales se especifique usar con una abertura de
conexión nominal de 1³⁄₈" (34,93 mm).
Se recomienda usar un cortacircuitos.
Se puede conectar la estufa directamente a una caja de
cortacircuitos (o un desconectador con fusible) a través de un
cable flexible o con forro no metálico, de cobre o aluminio.
Vea “Conexión eléctrica”.
Deje de 2 a 3 pies (61,0 cm a 91,4 cm) extra en la línea para
que se pueda mover la estufa en el caso que alguna vez sea
necesario darle servicio.
Debe proveerse un conector de conducto aprobado por UL a
cada extremo del cable de suministro de energía (en la estufa
y en la caja de empalmes).
El tamaño de los hilos y las conexiones deben cumplir con la
clasificación de la estufa (de 40 amperios).
El diagrama de cableado está ubicado en la parte posterior
de la estufa o dentro del cajón de almacenamiento, en una
bolsa de plástico transparente.
Si se va a conectar a un sistema de 4 hilos:
Esta estufa ha sido fabricada con la puesta a tierra conectada al
neutro por medio de un enlace. La puesta a tierra debe revisarse
para verificar que el hilo verde de puesta a tierra del cable de
suministro eléctrico de 4 hilos esté conectado a la carcasa. Vea
“Conexión eléctrica”.
Está prohibido hacer la puesta a tierra a través del conductor
neutro para las nuevas instalaciones de circuito derivado (1996
NEC); casas rodantes; y vehículos de recreación, o un área
donde los códigos locales prohíben la conexión a tierra a través
del terminal neutro.
Cuando se usa un contacto de 4 hilos de NEMA Tipo 14-50R, se
debe usar un cable de suministro eléctrico igual listado por UL
(cola de cochino flexible) para estufa de 4 hilos, 250 voltios y
40 amperios. Este cable contiene 4 conductores de cobre con
terminales de anillo o de horquilla con extremos abiertos y hacia
arriba, el cual termina en un enchufe NEMA Tipo 14-50P en el
extremo de suministro de energía.
El cuarto conductor (de puesta a tierra) debe estar identificado
con una cubierta verde o verde/amarilla y el conductor neutral
debe estar identificado con una cubierta blanca. El cable debe
ser Tipo SRD o SRDT con un protector de cables incluido en la
lista de UL y de un largo mínimo de 4 pies (1,22 metros).
Los tamaños mínimos para el conductor de suministro de cobre
de 4 hilos son:
circuito de 40 amperios
2 conductores N° 8
1 hilo blanco neutro N° 10
1 hilo verde a tierra N° 8
Si se va a conectar a un sistema de 3 hilos:
Es posible que los códigos locales permitan el uso de un cable
de suministro de energía para estufa (cola de cochino flexible)
que esté en la lista de UL, de 3 hilos, 250 voltios, 40 amperios.
Este cable contiene 3 conductores de cobre con terminales de
anillo o de horquilla con extremos abiertos y hacia arriba, el cual
termina en un enchufe NEMA Tipo 10-50P en el extremo de
suministro de energía. Los conectores del extremo del aparato
deben estar en el punto en que el cable de suministro de energía
entre en el aparato. Para ello se usa un contacto de 3 hilos de
Tipo NEMA 10-50R.
Voltaje de la estufa* Voltaje especificado
del juego de cable de
suministro de energía y
protección del circuito
120/240 voltios 120/208 voltios Amperios
8,0 - 16,5 KW
16,6 - 22,5 KW
6,0 - 12,5 KW
12,6 - 18,5 KW
40 ó 50**
50
Contacto de 4 hilos (14-50R)
Contacto de 3 hilos (10-50R)
17
INSTRUCCIONES DE INSTALACIÓN
Desempaque la estufa
1. No use la agarradera de la puerta del horno para levantar o
mover la estufa.
2. Quite los materiales de envío, la cinta adhesiva y la película
de la estufa. Mantenga la base de cartón debajo de la estufa.
Saque las parrillas del horno y el paquete de piezas del
interior del horno.
3. Saque los 4 esquinales de cartón de la caja. Apile un esquinal
de cartón sobre el otro. Repita con los otros 2 esquinales.
Colóquelos a lo largo, sobre el piso, detrás de la estufa para
protegerla cuando se coloque sobre su parte posterior. Con
la ayuda de 2 o más personas, agarre la estufa con firmeza y
colóquela suavemente sobre su parte posterior, en los
esquinales de cartón.
4. Jale la base de cartón con firmeza para quitarla.
5. Use una llave de tuercas o unas pinzas para aflojar las patas
niveladoras. Ajuste las patas niveladoras para corregir la
altura. Las patas niveladoras pueden aflojarse para agregar
un máximo de 1" (2,5 cm). Se necesita un máximo de
³⁄₁₆" (5,0 mm) para encajar el soporte anti-vuelco.
NOTA: Si se ajusta la altura cuando la estufa está de pie,
inclínela hacia atrás para ajustar las patas delanteras y luego
inclínela hacia delante para ajustar las patas traseras.
6. Coloque el cartón o madera frente a la estufa. Con la ayuda
de 2 o más personas, coloque la estufa de pie nuevamente
sobre el cartón o madera.
Instalación del soporte anti-vuelco
Póngase en contacto con un instalador competente de
revestimiento de pisos para ver cuál es el mejor procedimiento
para perforar orificios de montaje a través del tipo de
revestimiento de pisos que usted tenga.
Antes de mover la estufa, deslícela sobre la base de transporte,
cartón o madera.
1. Saque la plantilla del juego del soporte anti-vuelco (que se
encuentra dentro de la cavidad del horno) o de la parte
posterior de este manual.
2. Coloque la plantilla sobre el piso, en la abertura del armario,
de manera que el extremo izquierdo esté contra el armario y
el extremo superior esté contra la pared posterior, moldura o
armario.
3. Pegue la plantilla con cinta adhesiva en el lugar.
4. Si el mostrador no está alineado con el extremo de la
abertura del armario, alinee la plantilla con la saliente.
Si la abertura del armario es más ancha que lo especificado
en la sección “Requisitos de ubicación”, ajuste la plantilla de
manera que la estufa esté centrada en la abertura del
armario.
A. Base de transporte de cartón
ADVERTENCIA
Peligro de peso excesivo
Use dos o más personas para mover e instalar
la estufa.
No seguir esta instrucción puede ocasionar una
lesión en la espalda u otro tipo de lesiones.
A
Peligro de Vuelco
Un niño o un adulto puede volcar accidentalmente
la estufa y resultar muerto.
Conecte el soporte anti-vuelco a la pata trasera de
la estufa.
Si traslada de lugar la estufa, vuelva a conectar
el soporte anti-vuelco.
No seguir estas instrucciones puede ocasionar
la muerte o quemaduras graves en niños y adultos.
ADVERTENCIA
18
5. Para montar el soporte anti-vuelco al piso de madera, perfore
dos orificios de ¹⁄₈" (3,2 mm) en las posiciones marcadas en la
plantilla del soporte. Saque la plantilla del piso.
Para montar el soporte anti-vuelco a un piso de hormigón o
de cerámica, use una broca de taladro de albañilería de
³⁄₁₆" (4,8 mm) para taladrar 2 orificios en las posiciones
marcadas sobre la plantilla del soporte. Saque la plantilla del
piso.
6. Martille los taquetes de plástico en los orificios.
7. Alinee los orificios del soporte anti-vuelco con los orificios en
el piso. Sujete el soporte anti-vuelco con los tornillos
provistos. Según el espesor del piso, es posible que necesite
tornillos más largos para sujetar el soporte al contrapiso.
Puede conseguir tornillos más largos en su ferretería local.
8. Mueva la estufa cerca de la abertura para permitir que se
hagan las conexiones eléctricas. Quite la base de transporte,
cartón o madera que se encuentra debajo de la estufa.
9. Use una llave de tuercas o unas pinzas para bajar las patas
niveladoras delanteras media vuelta.
10. Ajuste las patas niveladoras para corregir la altura. Las patas
niveladoras pueden aflojarse para agregar un máximo de
1" (2,5 cm). Se necesita un mínimo de ³⁄₁₆" (5,0 mm) para
encajar el soporte anti-vuelco.
11. Mueva la estufa a su ubicación final, asegurándose de que la
pata niveladora trasera se deslice en el soporte anti-vuelco.
12. Si instala la estufa en una casa rodante, deberá fijar la estufa
al piso. El método que se use para fijar esta estufa debe
ajustarse al Estándar de seguridad y construcción de casas
fabricadas, Título 24 CFR, Parte 3280 (anteriormente
conocido como Estándar federal para la seguridad y
construcción de casas rodantes, Título 24, HUD Parte 280).
Cuando no sea aplicable ese estándar, use el Estándar para
instalaciones en casas fabricadas, ANSI A225.1/NFPA 501 A
u obedezca los códigos locales.
13. Continúe instalando la estufa siguiendo las instrucciones de
instalación.
A. Pata niveladora trasera
B. Pata niveladora delantera
A
B
19
Conexión eléctrica
Cable de suministro de energía Cable directo
1. Desconecte el suministro de energía.
2. Quite los tornillos de la tapa del bloque de terminal ubicados
en la parte posterior de la estufa. Jale la tapa hacia abajo y
hacia usted para sacarla.
3. Agregue el protector de cables.
Estilo 1: Protector de cables del cable de suministro de
energía
Ensamble en la abertura un protector de cables que es
en la lista de UL.
Haga pasar el cable de suministro de energía a través del
protector de cables en la placa del cable/conducto, en la
base de la estufa. Deje el hilo lo suficientemente flojo para
poder conectar el cableado al bloque de terminal.
Apriete el tornillo del protector de cables contra el cable
de suministro eléctrico.
Estilo 2: Protector de cables para cable directo
Use un destornillador Phillips para quitar los tornillos y
gire la placa del conducto 180º.
Coloque la placa del cable/conducto, como se muestra
en la ilustración siguiente.
ADVERTENCIA
Peligro de Choque Eléctrico
Desconecte el suministro de energía antes de darle
mantenimiento.
Use un cable de suministro eléctrico nuevo de 40 amp.
Enchufe en un contacto con conexión a tierra.
No seguir estas instrucciones puede ocasionar
la muerte, incendio o choque eléctrico.
ADVERTENCIA
Peligro de Choque Eléctrico
Desconecte el suministro de energía antes de darle
servicio.
Use un alambre de cobre de calibre 8 o un alambre de
aluminio de calibre 6.
Conecte la estufa a tierra.
No seguir estas instrucciones puede ocasionar
la muerte, incendio o choque eléctrico.
A. Tornillos de sujeción
B. Tapa del bloque de terminal
A. Protector de cables que esté en la
lista de UL - abertura grande
B. Abertura pequeña
A
B
A. Abertura grande
B. Abertura pequeña
A. Abertura pequeña
B. Abertura grande
A
B
A
B
20
Vuelva a colocar la placa del cable/conducto e inserte los
tornillos.
Ensamble en la abertura un conector de conducto que
esté en la lista de UL.
Haga pasar el conducto flexible a través del protector de
cables, dejando que quede lo suficientemente flojo para
poder conectar el cableado al bloque de terminal.
Apriete el tornillo del protector de cables contra el
conducto flexible.
4. Vuelva a colocar el panel posterior y los tornillos en la parte
posterior de la estufa.
5. Complete la instalación siguiendo las instrucciones que
corresponden al tipo de conexión eléctrica que usted tiene:
4 hilos (recomendada)
3 hilos (si no existe conexión de 4 hilos)
Opciones de conexión eléctrica
Conexión de 4 hilos: Cable de suministro de energía
Use este método para:
Nuevas instalaciones de circuito derivado (1996 NEC)
Casas rodantes
Vehículos de recreación
En un área donde los códigos locales prohíben la conexión a
tierra a través del terminal neutro
1. Parte del fleje de metal a tierra debe cortarse y quitarse.
2. Use un destornillador Phillips para quitar el tornillo de puesta
a tierra, ubicado en la parte posterior de la estufa. Guarde el
tornillo de puesta a tierra y el extremo del hilo de conexión a
tierra, ubicado debajo del tornillo.
A. Abertura pequeña
B. Abertura grande
A. Tuerca de retención removible - abertura pequeña
B. Conector del conducto
C. Abertura grande
A
B
A
B
C
Si su casa tiene: Y usted va a
conectar con:
Vaya a la sección:
Un contacto de 4 hilos
(Tipo NEMA 14-50R)
Un cable de
suministro de
energía para
estufa, aprobado
de UL, de
250 voltios
mínimo y
40 amperios
Conexión de
4 hilos: Cable de
suministro de
energía
Un cable directo de
4 hilos
Un
desconectador
con fusible o una
caja de
cortacircuitos
Conexión de
4 hilos: Cable
directo
Un contacto de 3 hilos
(Tipo NEMA 10-50R)
Un cable de
suministro de
energía para
estufa, aprobado
de UL, de
250 voltios
mínimo y
40 amperios
Conexión de
3 hilos: Cable de
suministro de
energía
Un cable directo de
3 hilos
Un
desconectador
con fusible o una
caja de
cortacircuitos
Conexión de
3 hilos:
Cable directo
A. Fleje de metal a tierra
B. Deseche
C. Tornillo de puesta a tierra
(12,7 cm)
5"
3"
(7,6 cm)
1"
(2,5 cm)
A
B
C
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Amana AEP222VAW Installation Instruction (2107.06 KB)

Category
Ovens
Type
Installation Instruction (2107.06 KB)
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages