V-ZUG DEHMR 8 Operating Instructions Manual

Category
Cooker hoods
Type
Operating Instructions Manual

This manual is also suitable for

2
2
INHALTSVERZEICHNIS
EMPFEHLUNGEN UND HINWEISE ..................................................................................................................................... 4
CHARAKTERISTIKEN ........................................................................................................................................................... 7
MONTAGE ............................................................................................................................................................................. 8
BEDIENUNG ........................................................................................................................................................................ 10
WARTUNG ........................................................................................................................................................................... 11
INDEX
RECOMMENDATIONS AND SUGGESTIONS ................................................................................................................... 13
CHARACTERISTICS ........................................................................................................................................................... 16
INSTALLATION .................................................................................................................................................................... 17
USE ...................................................................................................................................................................................... 19
MAINTENANCE ................................................................................................................................................................... 20
SOMMAIRE
CONSEILS ET SUGGESTIONS .......................................................................................................................................... 22
CARACTERISTIQUES ......................................................................................................................................................... 25
INSTALLATION .................................................................................................................................................................... 26
UTILISATION ....................................................................................................................................................................... 28
ENTRETIEN ......................................................................................................................................................................... 29
INHOUDSOPGAVE
ADVIEZEN EN SUGGESTIES ............................................................................................................................................. 31
EIGENSCHAPPEN .............................................................................................................................................................. 34
INSTALLATIE ....................................................................................................................................................................... 35
GEBRUIK ............................................................................................................................................................................. 37
ONDERHOUD ...................................................................................................................................................................... 38
IÇERIKLER
TAVSİYELER VE ÖNERİLER .............................................................................................................................................. 40
ÖZELLIKLER ........................................................................................................................................................................ 43
MONTAJ ............................................................................................................................................................................... 44
KULLANIM ........................................................................................................................................................................... 46
BAKIM .................................................................................................................................................................................. 47
УКАЗАТЕЛЬ
СОВЕТЫ И РЕКОМЕНДАЦИИ .......................................................................................................................................... 49
ХАРАКТЕРИСТИКИ ............................................................................................................................................................ 52
УСТАНОВКА ........................................................................................................................................................................ 53
ЭКСПЛУАТАЦИЯ ................................................................................................................................................................ 55
УХОД .................................................................................................................................................................................... 56
DE
EN
FR
NL
TR
RU
EN
1
13
RECOMMENDATIONS AND SUGGESTIONS
The Instructions for Use apply to several versions of this appliance.
Accordingly, you may find descriptions of individual features that do not
apply to your specific appliance.
INSTALLATION
The manufacturer will not be held liable for any damages resulting from
incorrect or improper installation.
The minimum safety distance between the cooker top and the extractor hood
is 650 mm (some models can be installed at a lower height, please refer to
the paragraphs on working dimensions and installation).
Check that the mains voltage corresponds to that indicated on the rating
plate fixed to the inside of the hood.
For Class I appliances, check that the domestic power supply guarantees
adequate earthing.
Connect the extractor to the exhaust flue through a pipe of minimum
diameter 120 mm. The route of the flue must be as short as possible.
Do not connect the extractor hood to exhaust ducts
carrying combustion fumes (boilers, fireplaces, etc.).
If the extractor is used in conjunction with non-electrical
appliances (e.g. gas burning appliances), a sufficient
degree of aeration must be guaranteed in the room in
order to prevent the backflow of exhaust gas. The
kitchen must have an opening communicating directly
with the open air in order to guarantee the entry of clean air. When the
cooker hood is used in conjunction with appliances supplied with energy
other than electric, the negative pressure in the room must not exceed 0,04
mbar to prevent fumes being drawn back into the room by the cooker hood.
The air must not be discharged into a flue that is used for
exhausting fumes from appliances burning gas or other
fuels (not applicable to appliances that only discharge the
air back into the room).
In the event of damage to the power cable, it must be
replaced by the manufacturer or by the technical service
department, in order to prevent any risks.
EN
1
14
If the instructions for installation for the gas hob specify a greater distance
specified above, this has to be taken into account. Regulations concerning
the discharge of air have to be fulfilled.
Use only screws and small parts in support of the hood.
Warning: Failure to install the screws or fixing device in accordance with
these instructions may result in electrical hazards.
Connect the hood to the mains through a two-pole switch having a contact
gap of at least 3 mm.
USE
The extractor hood has been designed exclusively for domestic use to
eliminate kitchen smells.
Never use the hood for purposes other than for which it has been designed.
Never leave high naked flames under the hood when it is in operation.
Adjust the flame intensity to direct it onto the bottom of the pan only, making
sure that it does not engulf the sides.
Deep fat fryers must be continuously monitored
during use: overheated oil can burst into flames.
Do not flambè under the range hood; risk of fire.
This appliance can be used by children aged from
8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
EN
1
15
• “CAUTION: Accessible parts may become hot when used with cooking
appliances.”
MAINTENANCE
Switch off or unplug the appliance from the mains supply before carrying out
any maintenance work.
Clean and/or replace the Filters after the specified time period (Fire hazard).
The Grease filters must be cleaned every 2 months of operation, or more
frequently for particularly heavy usage, and can be washed in a dishwasher.
The Activated charcoal filter is not washable and cannot be regenerated,
and must be replaced approximately every 4 months of operation, or more
frequently for particularly heavy usage.
"Failure to carry out cleaning as indicated will result in a fire hazard".
Clean the hood using a damp cloth and a neutral liquid detergent.
The symbol
on the product or on its packaging indicates that this product
may not be treated as household waste. Instead it shall be handed over to the
applicable collection point for the recycling of electrical and electronic
equipment. By ensuring this product is disposed of correctly, you will help
prevent potential negative consequences for the environment and human
health, which could otherwise be caused by inappropriate waste handling of
this product. For more detailed information about recycling of this product,
please contact your local city office, your household waste disposal service or
the shop where you purchased the product.
EN
1
16
CHARACTERISTICS
Dimensions
Components
Ref. Q.ty Product Components
1 1 Hood Body, complete with :Controls, Light, Blower,
Filters
8 1 Directioned grid
9 1 Reducer Flange ø 150-120 mm
10 1 Damper ø 150 mm
Ref. Q.ty Installation Components
10 12a Screws
12e 2 Screws 2,9 x 9,5
Q.ty Documentation
1 I nstruction Manual
10
9
8
12e
EN
1
17
INSTALLATION
Fitting the Hood canopy
BEFORE FITTING THE HOOD TO THE WALL UNIT, PROCEED AS FOLLOWS:
Open the suction panel by turning the specific knob.
Disconnect the panel from the hood canopy by sliding the
fixing pin lever.
Remove grease filters.
Disconnect the wires to the Commands at the connectors.
Disconnect the wires to the Light at the connectors.
Remove the frame by un-
fastening
the 6 screws.
The Hood can be installed directly on the
underside of the wall unit (Minimum 650 mm
from the Cooker Hob).
Create an opening in the bottom of the wall
unit, as shown.
Insert the hood until the side supports snap into
place.
Fasten using the 10 screws 12a provided.
Lock in position by tightening the screws Vf
from underneath the hood.
Screw the Frame back into place using the 6 screws removed as described above, re-connect
the wires to the Commands and Light, replace the metal grease filter and the Panel.
0
260
13
495 - 675 -835
EN
1
18
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to
the chimney using either a flexible or rigid pipe ø 150
or 120mm, the choice of which is left to the installer.
To install a ø 150 pipe
To install the dumper 10
Fix the pipe in position using sufficient pipe clamps
(not supplied).
To install a ø 120 pipe
To install a ø 120 mm air exhaust connection, insert
the reducer flange 9 on the dumper 10.
Fix the pipe in position using sufficient pipe clamps
(not supplied).
Remove any activated charcoal filters.
ø 120
ø 150
10
10
9
RECIRCULATION VERSION AIR OUTLET
Cut a hole ø 125 mm in any shelf that may be posi-
tioned over the hood.
Insert the reducer flange 9 on the hood body outlet.
• Connect the flange to the outlet on the shelf over the
hood by using a flexible or rigid pipe ø120 mm.
Fix the pipe in position using sufficient pipe clamps
(not supplied).
• Fix the air outlet grid 8 on the recirculation air outlet
by using the 2 screws 12e (2,9 x 9,5) provided.
Ensure that the activated charcoal filters have been
inserted.
9
ø 125
8
12e
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch having a contact gap of at least 3
mm..
EN
1
19
USE
A B C D E F G H
Control panel
Button Function Display
A Turns the suction motor on and off at speed one. Displays the set speed
B Decreases the working speed. Displays the set speed
C Increases the working speed. Displays the set speed
D Activate intensive speed from any other speed,
including motor off. This speed is set to operate
for 6 minutes, after which the system returns to the
speed that was set before. Suitable to deal with
maximum levels of cooking fumes.
Displays HI and the time remaining once very second.
Press and hold the button for approximately 5
seconds, with all the loads turned off (Motor and
Lights), to turn the Activated Charcoal Filter
alarm On and Off.
FC+Punto (2 flashes)–Alarm On.
FC+Punto (1 flash)–Alarm Off.
E 24H function
Turns the suction motor on at speed one and
effects one 10 minute extraction every hour.
Displays 24 and the spot at the bottom right flashes once
every second, while the motor is running.
It is disabled by pressing the button.
When the filters alarm is triggered, the alarm can
be reset by pressing and holding this button for
approximately 3 seconds.
These indications are only visible when the motor
is turned off.
FF flashes three times.
When the procedure terminates, the indication shown
previously turns off:
FG indicates the need to wash the metal grease filters.
The alarm is triggered after the Hood has been in
operation for 100 working hours.
FC indicates the need to change the activated charcoal
filters, and also to wash the metal grease filters. The alarm
is triggered after the Hood has been in operation for 200
working hours.
F Delay function
Activate automatic switch-off with a 30’ delay.
Suitable to complete elimination of residual
odours. Can be activated from any position, and is
disabled by pressing the button or turning the
motor off.
Displays the operating speed and the spot at the bottom
right flashes once a second.
Press and hold the button for approximately 5
seconds, with all the loads turned off (Motor and
Lights), to turn the Remote Control On and Off.
IR+Punto (2 flashes)–Alarm On.
IR+Punto (1 flash)–Alarm Off.
G Turns the lighting system on and off at maximum
intensity.
H Turns the Courtesy Lighting on and off.
EN
2
20
MAINTENANCE
REMOTE CONTROL (OPTIONAL)
The appliance can be controlled using a remote control powered
by a 1.5 V carbon-zinc alkaline batteries of the standard LR03-
AAA type (not included).
Do not place the remote control near to heat sources.
Used batteries must be disposed of in the proper manner.
Opening Panel
Open the Panel by pulling it.
Clean the outside with a damp cloth and neutral detergent.
Clean the inside using a damp cloth and neutral detergent; do
not use wet cloths or sponges, or jets of water; do not use
abrasive substances.
Metal grease filters
They can be washed in the dishwasher, and need to be cleaned
whenever the FG sign appears on the display or at least once
every 2 months use, or more frequently if use is particularly
intensive.
Resetting the alarm signal
Turn the Lights and the Suction motor off, then disable the 24h
function, if enabled.
• Press button E (see the paragraph on Use).
Cleaning the Filters
Open the Comfort panels by pulling on the recess.
Remove the Filters one at a time, pushing them towards the
back of the unit and at the same time pulling downward.
Wash the Filters without bending them, and leave them to dry
completely before replacing. (If the surface of the filter
changes colour as time goes by, this will have absolutely no
effect on the efficiency of the filter itself.)
Replace, taking care to ensure that the handle faces forwards.
Close the Comfort panels.
EN
2
21
Activated Charcoal Filter (Recirculation Version)
Can be washed in the dishwasher. It must be washed when Led S1 flashes or at least once eve-
ry 4 months, or more frequently if use is particularly intense. Guaranteed to operate after
washing for up to a maximum of 5 times before requiring replacement. The Alarm signal, if it
has been activated, only appears when the Suction motor is turned on.
Activating the alarm signal
In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on
installation or at a later date.
Turn the Lights and the Suction Motor off.
• Press D and hold for approximately 5 Seconds:
• The message FC+Puntino flashes twice, A.C. Filter saturation alarm ACTIVATED
• The message FC+Puntino flashes once, A.C. Filter saturation alarm DEACTIVATED
CHANGING THE ACTIVATED CHARCOAL FILTER
Resetting the a
larm signal
Turn the Lights and the Suction motor off, then disable the 24h
function, if enabled.
• Press button E (see the paragraph on Use).
Changing the Filter
Open the Comfort panels by pulling on the recess.
Remove the Metal grease filters.
Remove the saturated Activated Charcoal Filters, as indicated
(A).
Fit the new Filters, as indicated (B).
Replace the Metal grease filters.
Close the Comfort panels.
A
B
Lighting unit
For replacement contact technical support ("To purchase
contact technical support").
Service & Support
The «Troubleshooting» chapter provides valuable information for dealing with
minor operating faults. This saves you the time, effort and potential cost of having
to call out a service technician.
Information on the V-ZUG warranty can be found at www.vzug.com →Service →Warranty in-
formation. Please read this information carefully.
Please register your V-ZUG appliance online immediately at www.vzug.com →Service
→Warranty registration. This will allow you to take advantage of the best possible support
in the event of an fault in the appliance during the warranty period. You will require the
serial number (FN) and appliance designation to complete the registration process. This
information can be found on the identification plate for your appliance.
My appliance information:
FN:
___________________
Appliance
: _____________________
Always have this appliance information to hand when you contact V-ZUG. Thank you.
Remove the metal grease filter.
The identification plate is located on the inside of the appliance.
Your repair order
At www.vzug.com →Service→Service number you will find the telephone number of your
nearest V‑ZUG service centre.
Technical questions, accessories, warranty extensions
V-ZUG is happy to help you with any general administrative or technical queries, to take
your orders for accessories and spare parts and to inform you about our progressive ser-
vice agreements.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84

V-ZUG DEHMR 8 Operating Instructions Manual

Category
Cooker hoods
Type
Operating Instructions Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages