Hunter Fan 44377W User manual

Category
Thermostats
Type
User manual
Form# 44045-01
20100224
©2010 Hunter Fan Co.
Set & $aveSet & $aveSet & $ave
Installation and
Operation Manual
Model
44377W
Programmable
Thermostat
English
2
3
Table of Contents
important information ............................................................................................................................ 5
tools ................................................................................................................................................................................ 6
uninstalling the existing unit ............................................................................................................. 9
wire labels ................................................................................................................................................................10
installing the thermostat .....................................................................................................................13
settings .......................................................................................................................................................................23
methods of operation................................................................................................................................27
default programs Chart ..........................................................................................................................36
iCons and features ..........................................................................................................................................43
important features ........................................................................................................................................54
wiring diagrams................................................................................................................................................55
troubleshooting .............................................................................................................................................58
warranty ..................................................................................................................................................................61
4
Congratulations!
Thank you for choosing a Hunter programmable thermostat. Your
new Hunter thermostat will provide years of reliable service and
year-round energy savings.
Please read this manual before beginning installation and save this
booklet for complete operation instructions.
The Hunter Technical Support Group is available from 7 am to 7 pm Monday
- Friday and 8:00 to 5:00 Saturdays CST. They may be reached toll-free at
1-888-830-1326.
Set & Save
Programmable Thermostat
Model 44377W
5
This thermostat is designed to work on the following
heating and cooling systems:
Gas – Standing Pilot
Gas – Electronic Ignition
Gas – Fired Boilers
Gas – Millivolt Systems
Oil – Fired Boilers
Oil – Fired Furnace
Electric Furnace
Electric Air Conditioning
Single-Stage Heat Pumps
This thermostat is not designed for multi-stage heat pump systems
or 110/220 V baseboard heating systems.
If you are unsure what kind of heating and cooling system you
have, please contact a qualied HVAC Technician for assistance.
important information
6
This thermostat includes two #8 slotted screws and two wall
anchors for mounting.
To install your new thermostat, you will need the following supplies:
Flat-head screwdriver
.............................................................................................
Small Phillips-head screwdriver
.............................................................................................
Hammer
.............................................................................................
Electric drill and 3/16” bit
.............................................................................................
Two 1.5 Volt (AA) size alkaline batteries
.............................................................................................
tools
7
NOTICE! Do not disconnect the wires from the existing
thermostat before reading these instructions. The wires
must be labeled prior to removal to ensure proper
reconnection.
Y
RC
G
W
w
Y
RC
G
W
8
Y
RC
G
W
Y
RC
G
W
9
1. Turn the system power OFF from the existing thermostat. Turn
the power to the HVAC system OFF at the main power panel or
at the furnace.
(Failure to turn off the power to the existing thermostat before
removal could damage your system.)
2. Remove the existing thermostat cover to access the wires from
the wall.
(Some thermostats may have multiple covers, screws or other
locking devices that must be removed or disengaged. See page
8 for common examples.)
3. Locate, but do not disconnect the wires.
(If wires are not visible, they may be connected to the back
of the wall plate. Some models may have doors that open to
expose the wires and mounting screws.)
uninstalling the existing unit
10
G RC RH Y W
if your existing thermostat
is marked...
label the wire with
this sticker:
G / F
G
G
W / H / B
W/B
W/B
Y / C* / M / O
Y/0
Y/0
RC / VC
RC
RC
RH / R / VR / 4
RH
RH
24 Volt
24 Volt cool
air conditioning
compressor
heating
fan
Y1
Y1
Y1
heat pump compressor
wire labels
11
4. Using the provided stickers, label each wire according to the
Wire Labels chart.
(If the terminals are not labeled,
contact a qualied HVAC technician.)
Note: Wire colors do not always comply with standards, so
wire color should be ignored. Refer to the existing terminal
designation for proper identication.
*If wires marked Y & C are both present, C may be a
Common wire and should not be used. If you have a wire
marked C, do not connect it to any terminal. This wire is used only
for non-battery powered thermostats.
5. Do not let the wires slip back into the wall during disconnection.
You may want to secure the wires to the wall as you disconnect
them. After all wires are labeled, disconnect each wire and
remove the existing wall plate.
(Any unused wires should be capped with an approved electrical connector,
such as electrical tape.)
uninstalling the existing unit, cont.
Y
RC
G
W
W
12
W/B
RC
G
Y/0
Y1
13
installing the thermostat
INSTALLING THE WALL PLATE
1. Remove the wall plate from the new thermostat by pressing the
release tab on the bottom of the thermostat.
2. Position the new wall plate on the wall and pull the labeled wires
through the opening.
3. If the existing holes do not match those on the Hunter wall plate,
or if there are no existing holes, visually level the wall plate and
mark the wall for two holes.
14
W
RC
Y
G
15
4. Remove the wall plate and drill two 3/16” holes where marked.
5. Tap the plastic anchors into the holes until they are ush with the
wall. (Do not use plastic anchors if you encounter a stud in the
wall.)
6. Reposition the wall plate on the wall, pulling the wires through
the opening. Insert the mounting screws through the wall plate
and into the anchors. Verify that the wall plate is visually level
and securely tighten both screws.
installing the thermostat, cont.
16
G
RC RH
Y/0
W/B
RC
G
Y1
Y/0
W/B
Y1
Terminal Shield
17
INSTALLING THE THERMOSTAT, CONT.
CONNECTING THE WIRES
1. Loosen, but do not remove, the terminal screws.
Note: A jumper wire has been provided, connecting the
RC and RH terminals for systems that do not provide both
an RH and RC wire. If you have both an RH and RC wire,
remove this jumper. If you do not have both an RH and RC
wire, leave the jumper in place.
2. Match and connect the wires from the wall to the
terminals as shown. Wires should be inserted behind the black
terminal shields. Tighten each screw after the connection has
been made.
(The ends of any extra wires should be individually wrapped in electrical
tape and carefully pushed back into the wall.)
3. Push any excess wire length back into the wall to prevent
interference.
G RC RH Y W
Jumper
18
DISABLE
ENABLE
RECOVERY
HG
HE
W/B Y/O RH RC G
SYSTEM TYPE
STD
HP
Y1
FAN OPTION
AM
HEAT
4
T
Thermostat
Cover
System
Switch
Fan
Switch
19
ATTACHING THE THERMOSTAT
Lift the thermostat cover and set the SYSTEM switch to OFF and
the FAN switch to AUTO.
1. Fan option - Locate the HE/HG switch on the back of the
thermostat. Set the switch to HG (default) for gas furnace and oil
burners. Set the switch to HE for electric furnaces. (The switch
has no effect when the system is set to cooling mode.)
2. Recovery - Locate the
AUTO REcOvERY
switch on the back of the
thermostat. If you wish to use the Auto Recovery feature, verify
that the switch is in the ENABLE position. If you do not wish
to use this feature, simply change the switch to the DISABLE
position. See pages 44-45 for more information.
3. System type - Locate the
SYSTEM TYpE
switch on the
back of the thermostat. Select either STD (Standard) or HP
(Heat Pump) to match your system.
installing the thermostat, cont.
20
1
2
front cover
Tab
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64

Hunter Fan 44377W User manual

Category
Thermostats
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI