Electrolux 9CHG584138 User manual

Category
Cookers
Type
User manual
thermaline S90
PASTA COOKER, GAS
-
PASTA COOKER POUR GAZ
Doc.
62.9680.01_UL
Edition 1
01.2006
US INSTALLATION- AND OPERATING INSTRUCTIONS page 3
FR INSTRUCTIONS D’INSTALLATION ET D’EMPLOI page 13
FOR YOUR SAFETY
Do not store or use gasoline or
other flammable vapors or liquids
in the vicinity of this or any other
appliance.
POUR VOTRE SÉCURITÉ
Ne déposez pas ou n'employez
pas l'essence ou d'autres vapeurs
ou liquides inflammables à pro-
ximité de ceci ou d'aucun autre
appareil.
WARNING
Improper installation, adjust-
ment, alteration, service or
maintenance can cause property
damage, injury or death. Read the
installation, operating and
maintenance instructions thorou-
ghly before installing or servicing
this equipment.
AVERTISSEMENT
L'installation inexacte, l'ajuste-
ment, le changement, le service
ou l'entretien peuvent causer des
blessures matériels, des domma-
ges ou la mort. Lisez les instruc-
tions d'installation, d'opération et
d'entretien complètement avant
d'installer ou entretenir cet
équipement.
INSTRUCTION
Post in a prominent location instructions to be followed if the user smells gas. Consult
the local gas supplier to obtain the information.
Présentez dans des instructions en avant d'un endroit d'être suivi si l'utilisateur sent le
gaz. Consultez le fournisseur local de gaz pour obtenir l'information.
Doc. 62.9680.01_UL
Against wall - contre une paroi
Free standing - isolé
Connections - Raccordement
Gas - Gaz
Fig.1 INSTALLATION DRAWINGS - PLANS D'INSTALLATION
GENERAL INFORMATION
62.9680.01_UL Page 3
I . GENERAL INFORMATION
1. INSTRUCTIONS FOR SAFETY AND USE
1.1 INSTALLATION AND INITIAL OPERATION
1.2 OPERATOR'S OBLIGATIONS
1.3 USE AS PRESCRIBED
1.4 SAFETY-CONSCIOUS WORKING
S The installation, adjustment and initial opera-
tion of the appliance must be carried out
according to the manufacturer's instructions
and may only be done by an authorised spe-
cialist.
S Installations for the supply of electricity and
gas must be carried out by approved special-
ists in compliance with specific national and
local regulations. They bear the responsibil-
ity.
S The installation must conform with local
codes, or in the absence of local codes, with
the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, or the Natural Gas and
Propane Installation Code, CSA B1 49.1.
S The appliance and its individual shutoff valve
must be disconnected from the gas supply
piping system during any pressure testing of
that system at pressures in excess of 1/2 psi
(3.5 kPA)
S The appliance must be isolated from the gas
supply piping system by closing its individual
manual shutoff valve during any pressure
testing of the gas supply piiping system at
test pressures equal to or less than 1/2 psi
(3.5 kPA)
S The manager is responsible for ensuring that
all components relevant to safety are in per-
fect working order at all times. The operating
condition of these components must be
examined by an authorised specialist at least
once a year and any defects remedied if
required.
S The operator of this appliance is responsible
for total observation of the national regula-
tions concerning operating safety.
S Remain the manual for future reference.
S Closed containers (jars, cans, bottles, tubes,
etc.) must not be heated owing to the danger
of bursting and injuries.
S Baskets filled with food must be placed
slowly in the full water trough, so the the hot
water does not overflow. - Danger of
burning!
S Ensure that no substances are put into the
water bath that could cause excess foaming
when boiling. - Danger of burning!
S The trough heating must not be switched on
if there is no water in the trough or the water
level has fallen below the minimum level. -
Risk of fire.
S The escape of burnable gases represents a
fire and explosion hazard. Action in the case
of a gas leak and a smell of gas:
- No smoking, no fire
- Do not operate electric switches or bells.
- Do not operate the piezo igniter
- Close gas cylinder valves and the main
gas valve on the appliance.
- Ventilate the room thoroughly
- Place the leaking gas cylinders upright in
the open with valves closed.
S The waste-gas outlets of the pasta cooker
become hot. Avoid touching them.
S The waste-gas outlets of the psta cooker are
not to be covered by any objects.
S Spraying the appliance or parts of it with a
high-pressure cleaning device may cause
malfunctions and is not to be done.
S Keep the appliance area free and clear from
combustibles
S Do not obstruct the flow of combustion and
ventilation air.
S For appliances with a downpipe, the hose
should lead into a drain opening which is cov-
ered by a grating such that it cannot be
kicked or tipped, or a drain gutter should run
underneath the appliance.
S Devices on wheels set up in block
configuration must be checked before each
start-up whether the potential equalization is
connected with the neighbour equipment.
The connection may be done only by
authorized technical personnel.
S Appliances on wheels must be fastened to
the building.
GENERAL INFORMATION
Page 4 62.9680.01_UL
1.5 AFTER-SALES SERVICE AND REPAIR 2. TECHNICAL DATA
3. PACKAGING
All the packaging materials used are environmentally friendly.
They may burnt at an incineration plant or sent for recycling.
4. TESTS / CERTIFICATES
All gas appliances are tested according to the standard ANSI
Z83.11-2002 and CSA 1.8-2002 of Gas Food Service Equip-
ment.
5. SPECIFICATION PLATE
The specification plate (E) is located in each case inside and
outside on the right of the operator panel (C) (Fig. 5).
The serial number is marked on the type plate. The 8 digits
give following information:
Y last digit of the year of production
WW week of production
XXXXX running number
S In the event of a permanent fault which inter-
feres with operation, the appliance must be
switched off and disconnected from the
power supply.
S To perform maintenance and repairs contact
the factory, the factory representative or a
local service company.
S Repair, maintenance work and other adjust-
ments are only to be carried out by an
authorised specialist. The valid local and
national regulations must be observed. This
applies especially to burners, ignition, safety
and control elements. Parts requiring
replacement are only to be replaced by origi-
nal spare parts. Periodic tests for gas leaks
must be carried out. A service contract is
therefore recommended.
S Cleaning and maintenance must be done
only when the heating surfaces are cold. Do
not use inflammable liquids to clean the
appliance.
S An obligatory service check is required
annually.
PNC Appliances Appliance type
Width
Depth
Height
Base
feet
height
Trough
capacity
Power
Gas
consumption
in mm in Liter
9CHG584138 WKGROFOOOO 500
900
700
200 1 x 40
14.3 kW
49000 BTU
9CHG584139 WKGROAOOOO
INSTALLATION INSTRUCTIONS
62.9680.01_UL Page 5
II . INSTALLATION INSTRUCTIONS
1. INSTALLATION
The appliance is designed for connection to fixed lines. The
appliances are suitable for setting up as single appliances or as
a group of appliances. They can be set up freely in the room,
side by side, at the side and/or at the back against a wall.
Gaps between two appliances or appliance and sidewall
should be filled with a FDA approved silicone such as Samco
RTV103.
1.1 DISTANCES
If an appliance is set up next to or against temperature-sensi-
tive furniture or similar, a safety gap of approximately 6“ (150
mm) should be maintained or some form of heat insulation fit-
ted.
The walls must be made up of non-combustible material like
tiles or steel.
1.2 HEIGHT ADJUSTMENT
Appliance on feet.
D Turn the lower part of the feed to adjust the appliance high.
The feet are adjustable from 4“ to 8“ (100 to 200 mm). A high
of 8“ (200 mm) can be recommended and results in an appli-
ance high of 35,4“ (900 mm).
Note:
Adjustment of the legs shall provide an unobstructed
clearance of minimal 6“ (150 mm) and maximal 8“ (200
mm) beneath the unit due to sanitary and stability
aspects.
The lower part of the foot must not be unscrewed too far.
The exposure of threads is prohibited.
1.3 ASSEMBLING TWO APPLIANCES
The assembly kit contains two of each of the following:
caged nuts (1 / Fig.1) pre-assembled on the right-hand side of
the appliance, hexagonal screws M8x25 (1 / Fig.1) and moun-
ting links (2 / Fig.1)
D Remove the control panels from both appliances as in 2.2
D Remove the front panels from both appliances as in 2.1
D Keeping the screw (1 / Fig.1) loose, turn it until it is approxi-
mately 5 mm deep in the caged nut.
Positioning the appliances:
D Place the appliances next to one other.
D Align for position and height.
Connect the appliances:
D Fit the mounting link (2 / Fig.1) into the inside of the second
appliance's left connecting plate.
D Tighten the screws.
Note
If required, the caged nuts can also be fitted on the other side
of the appliance.
Appliance on feet: Alignment is carried out by screwing the
lower foot parts in or out.
Appliance on
steel plinth:
Irregularities or differences in height can
be equalized by inserting one or several
strips of chrome nickel steel.
a
b
c
Fig.1 Lateral connection
(1)
(1)
(2)
(2)
(3b)
(3a)
(3c)
(1)
(2)
1
(3c)
INSTALLATION INSTRUCTIONS
Page 6 62.9680.01_UL
1.4 SIDEWALL (D)
The assembly kit contains two of each of the following:
hexagonal screws M8x25 (1 / Fig.1), bolts with retaining rings
(2 / Fig.1), mounting links (3 / Fig.1), hexagonal screws M8x16
with serrated washers and hexagonal nuts M8, hexagonal
screws M5 with serrated washers (4 / Fig.2)
and a fastening angle (5 / Fig.2).
D Insert the bolts with the retaining rings (2 / Fig.1a) from out-
side into the guide in the sidewall.
D Keeping the screw (1 / Fig.1a) loose, turn it until it is
approximately 5 mm deep in the pre-assembled caged
nuts in the sidewall.
D Attach the fastening angle (5 / Fig.2b) to the bottom of the
frame using the screws, serrated washers and nuts.
D (4 / Fig.2).
D Position the sidewall and screw it on from below using two
hexagonal screws and the serrated washers.
D Fit the mounting link (3 / Fig.1b) into the inside of the appli-
ance's connecting plate.
D Align the sidewall and firmly tighten all screws.
1.5 STEEL PLINTH
To assemble the plinth you will need:
Right and left side plinth (1 / Fig.3).
Plinth for the front and, for free-standing appliances, for the
rear also (2 / Fig.3).
D Push the side plinth (1 / Fig.3) onto the legs from front to
rear using the fastener. The larger gap (b / Fig.3) on the
fastener must be at the bottom.
D Affix the fasteners (3 / Fig.3) to the plinth (2 / Fig.3).
D The larger gap (b / Fig.3) on the fastener must be at the
bottom.
D Attach the plinth with the fasteners (3 / Fig.3) onto the feet.
1.6 ASSEMBLING ON CASTORS
The assembly kit for mounting on castors contains two cross
bars (2/Fig.4a) each with a fixed rear wheel (1/Fig.4a) and a
turnable front wheel (3/Fig.4a).
Mounting the castors:
D Put the appliance on supports.
D Remove the feet; each is tightened with four screws
(Fig.4b).
D Bring the two cross bars into the correct position below the
appliance and fasten it with 8 screws arrows (Fig.4a).
D Remove the supports.
D Fasten the appliance to the building. Use the hole to attach
a chain descending from the wall (arrow/Fig.4c). Making
sure the chain is shorter than the gas and electric connec-
tions.
Note:
Appliances on wheels must be secured by fasten it to the
building.
2. ACCESS TO INTERIOR
Note:
Only authorized technicians may access the interior.
a
b
Fig.2 Assemblage of sidewall
a
b
Fig. 3 Plinth assembly
1
()
(5)
(4)
1
(3c)
1
()
(5)
(4)
(1)
(2)
(3)
b
b
1
(3c)
(1)
(2)
(3)
a
b
c
Fig.4 Assemblage on castors
Fig. 5 General view
1
()
(5)
(4)
1
(3c)
1
(3c)
11
D
D
B
E
C
11
INSTALLATION INSTRUCTIONS
62.9680.01_UL Page 7
3. FRONT PANELS (A) and (B)
D Unscrew screws (1 or 3). Also, in the case of a built-in oven,
unscrew screws (2 and/or 4) on the inside of the oven.
D Pull the panel away forwards and downwards.
3.1 CONTROL PANEL (C)
D Remove the knob.
D Loosen the screws underneath (1 / Fig.7a) and remove the
base plate.
D Loosen the screws (2 / Fig.7b) and 3 / Fig.7c)
D Remove the panel.
3.2 OVEN, STORAGE SPACE, HOT CABINET
D Remove panels A, B and C.
D Undo screws (5).
D Pull out element.
4. DOWNPIPE
Work surfaces with a downpipe (Fig.8a) have the downpipe
opening on the right-hand side of the appliance. A flexible sili-
con hose when installed in the standard manner ends under-
neath and to the right, 20 mm behind the front of the appliance
(Fig.8b).
D Alternatively, the hose can be relocated to the rear and be
routed through other pre-cut openings (Fig.8c).
Fig.6 Front panel
ab
Fig. 7 Control panel
c
(1)
1
(3c)
(1)
1
(3c)
(2)
(3)
a
b
Fig. 8 Downpipe
c
1
(3c)
(1)
(3)
INSTALLATION INSTRUCTIONS
Page 8 62.9680.01_UL
5. GAS CONNECTION
The installation of the gas connection, as well as the laying of
the customer's gas line, is only to be carried out by an author-
ised specialist subject to the relevant national and local regula-
tions.
NOTE
The gas appliance may only be installed in an adequately
ventilated location.
Appliances are set up for natural gas. The type of gas, gas
pressure and gas category are entered on the specification
plate. Prior to connection, check that the appliance is set
up for the type of gas available on site. To do this, compare
the details on the specification plate with the existing gas
data.
If this is not the case, the appliance must be converted or
adapted by the service personnel responsible to suit local
conditions. The following points should be noted:
- Has the appliance been tested for the new gas data?
- Conversion in accordance with the Service Manual.
- A new specification plate or a durable marking with the
new gas data must be affixed to the appliance.
5.1 CONNECTION
Gas-only appliances as well as combination electric and gas
appliances require a gas connection.
The gas connection is located under the appliance on the right
hand side. For all types the gas connection is NPT 3/4“.
The installation of a dirt trap in the gas supply line by the owner
is recommended.
After connection, all lines carrying gas must be tested for leaks
at operating pressure by painting with non-corrosive foam-
forming media, (e.g. soapy water or leak spray).
5.2 GAS PRESSURE
The current gas pressure should be measured at the Mertik
regulator with a liquid U-tube manometer (scale at least 0.1
mbar = 1 mm water column).
D Remove the control panel. The measuring nipple is located
in downwards direction at the gas supply pipe before the
two gas valves.
D Close off the mains gas leading to the appliance.
D The measuring nipple is provided at the left side of the reg-
ulator. The incoming pressure is measured in front, the out-
going pressure behind.
D Loosen the slotted screw (1 turn) in the measuring nipple.
Then connect the pressure gauge by attaching a flexible
tube to the nipple (out-side diameter 8 mm).
D Open the main gas leading to the appliance.
D Run all burners on the appliance at full output.
D Check whether the connection pressure is in permitted tol-
erance.
D Turn off the appliance again.
D Close the main gas valve.
D Retighten the slotted screw in the measuring nipple. Gas
pressure deviation tolerances are laid down by EN 203. If
the existing gas pressure is outside the given tolerances,
correct combustion can no longer be ensured. Compulsory
measures: pressure adjustment by the gas works or con-
version of the range by the service personnel. Please refer
to "Conversion to another gas type".
Gas pressure tolerances
Gas pressure variation tolerances are as
follows: mbar
Gas type Normal
pressure
Min.
pressure
inch
water g.
mbar inch
water g.
mbar
Natural gas A 7 17.4 3.5 8.7
USA
Liquid gas E 11 27.4 8.0 20
Propane
USA
INSTALLATION INSTRUCTIONS
62.9680.01_UL Page 9
6. WATER CONNECTIONS
6.1 DRINKING WATER CONNECTION
Before connecting the appliance, flush the water pipes and
fittings and clean out any dirt.
The appliance is designed for connection to fixed lines.
Metal installation pipes may not protrude more than 3.9“
(10 cm) from the floor or the wall.
The maximum water pipe pressure must not exceed 87 psi
(600 kPa).
A mechanical filter, a shutoff valve and a non-return valve
should be built into the customer fresh water feed pipe.
In general, all national and local water regulations must be
observed.
The appliance is to be connected to the sanitation system
in accordance with the valid installation connection plans
and diagrams.
6.1.1 FREE-STANDING INSTALLATION
The water connections come up from the floor.
D Make corresponding openings in the base of the frame to
lead the hoses through.
D Remove front panel (B) (see Chapter 3. on page 7).
D Dismantle the storage space or hot cabinet if necessary.
D Connect the flexible hoses (5), with a G ½" inside thread,
with or without fitting a stop valve, to the customer-supplied
water pipes protruding from the floor.
6.1.2 FITTING AGAINST A WALL
The water connections come up from the floor or out of the
wall. For floor connection (see Chapter 6.1.1 on page 9).
D Pull the flexible hoses (5) out of the open rear wall and con-
nect to the customer-provided water pipes protruding from
the wall with a G ½" inside thread, with or without fitting a
stop valve.
D Position the appliance against the wall.
6.2 WASTE WATER
The appliance outlet pipe must be taken through a sufficiently
large waste water opening.
Note
Ensure accurate measurement of the waste water collecting
point and the exact positioning of the appliance.
OPERATING INSTRUCTIONS
Page 10 62.9680.01_UL
III . OPERATING INSTRUCTIONS
1. GENERAL
The Pasta Cooker is used for boiling pasta of all types, rice,
noodles, dumplings, vegetables and soups. The desired
temperature can be adjusted between 50 and 100 °C.
The water trough has a capacity of 40 litres and is operated by
a 13 kW output bar burner.
In the front part of the water trough there is a standing surface
for parking and draining off the baskets. Excess water or foam
can run off through a water overflow under the standing
surface.
The water trough is seamlessly integrated into the appliance
cover. Sharply rounded corners and edges facilitate easy
cleaning. All parts of the appliance are made of corrosion-
resistant stainless steel.
Recommended accessories:
- rectangular baskets, 1 x GN 1/1, 2 x GN 1/2 or
3 x GN 1/3
- round baskets, 3
- Base insert to stand round baskets on.
-Cover
2. OPERATION
D Turn on main gas tap (1/Fig.9).
0 = Off
1 = On
D For liquid gas operation also open the bottle or tank valve.
D Switch on gas burner (Chapters 2.1 and 2.2)
D Turn on the water supply tap (4/Fig.9) until the trough is
full.
D Switch on trough heating (Chapters 2.3 and 2.4).
D Water loss in the trough can be replaced by turning on the
tap (4/Fig.10).
The knob (2/ Fig.9) has four main settings:
2.1 IGNITING THE PILOT BURNER
D Push the knob (2/Fig.9) fully in.
D Turn it anti-clockwise to the pilot burner ignition ( )
position.
D Hold the knob (2/Fig.9) fully pressed in.
D At the same time, ignite the gas escaping at the pilot
burner with the piezo ignition device. The burner is ignited
by turning the knob (3) clockwise or anti-clockwise.
D After lighting the pilot burner, keep the rotary switch
pushed in for about 15 seconds.
It is only after this period of time that the pilot light will burn
after the rotary switch is released.
D If the pilot light extinguishes, repeat the whole process.
2.2 IGNITING THE MAIN BURNER
D Press the knob (2/Fig.9) in lightly and turn it from the pilot
burner ignition position ( ) anti-clockwise to the high ( )
position.
The high position ( ) equates to the maximum burner
power or rated thermal load.
2.3 TEMPERATURE SELECTION
The intensity of the flame can be adjusted between the "high
position" ( )and the "low position" ( ).
D Push the knob (2/Fig.9) fully in and turn it anti-clockwise
from the high setting ( ) towards the lowest ( ) setting.
The flame becomes smaller and smaller.
In the lowest setting ( ) the main burner has the lowest
output.
D To return from the lowest setting ( ) towards the highest
setting ( ), push the knob (2 / Fig.9) fully in and turn it
clockwise.
Note:
Do not switch on the trough heating or leave it switched on, if
the water level falls below the marking on the trough wall. Non-
observance of these instructions can cause severe damage to
the boiling trough and the appliance operating elements.
2.4 INITIAL OPERATION
Before initial operation of the appliance, the trough and the
baskets must be thoroughly cleaned of the protective industrial
grease by carrying out a boiling procedure without food and
with the addition of neutral soap.
2.4.1 STANDBY
The water must always be at the correct level, clean and
always able to be kept at the boil.
Check before each use:
D The water trough overflow must not be blocked.
D The operating elements must not be damaged.
1 Knob
2 Switch, Piezo ignition device
Fig.9 Control panel
Off
Igniting the pilot burner
High setting
Low setting
1
2
4 Water supply tap
5 Water drain valve
Fig.10 Front view
4
5
OPERATING INSTRUCTIONS
62.9680.01_UL Page 11
2.4.2 WORKING RULES
D Turn the switch (2/Fig.9) to the highest setting ( ).
D As soon as the water in the trough has reached boiling
point, add salt and ingredients. The use of fine salt is
recommended, to prevent corrosion of the trough base. If
this is not available, dissolve the salt beforehand in a sepa-
rate container of water.
D Place the baskets with the food to be cooked slowly in the
trough.
The overflow pipe ensures control of the maximum amount
of water and the escape of any foam that occurs during
cooking.
D Set the appropriate cooking temperature with the switch
(2/Fig.9), according to the quantity and quality of the food
to be cooked.
2.5 SWITCHING OFF THE OVEN
2.5.1 MAIN BURNER
D Turn the knob (2/Fig.9) back clockwise from the highest
setting ( ) to pilot burner ignition ( ).
The gas supply to the main burner is stopped and the main
flame is shut down. The flame of the pilot burner keeps on
burning and is available for further main burner ignitions.
2.5.2 PILOT BURNER FLAME
D Press the knob (2/Fig.9) lightly and turn it clockwise from
pilot burner ignition to Off.
The complete gas supply is cut off and the pilot light
extinguishs.
= Off
D Ignition can only start again when the heating element has
cooled down.
2.5.3 WATER DRAIN
D Drain the water from the trough by opening the water outlet
valve (5/Fig.10) (turn the handle anti-clockwise into the ver-
tical position).
D Clean any food residues from the trough and the baskets.
2.5.4 LONG SHUT-DOWNS
The following should be observed when shutting down for a
long period:
D When operating with liquid gas, also turn off the bottle or
tank valve.
D Never store the appliance where the temperature can drop
below 32°F (0 °C).
D Do not leave the troughs full of water, since this prevents
the normal passivation of the steel and the surfaces are
thus less resistant to corrosion.
D Rub all chrome nickel steel surfaces with a cloth soaked in
vaseline oil, to lay down a thin protective coating.
D Air the installation site regularly.
D Turn off the water supply.
3. CLEANING
The appliance should be cooled before every cleaning
operation.
Clean at least once daily after use:
D Shut off all the gas taps and control valves on the range.
D Drain water from the trough.
D Clean outlet nozzles with a brush.
D Remove the outlet strainer of the floor of the water trough
(snap fastening) and clean.
D Clean the outlet on the base of the trough as well as the
overflow (8) with a bottle brush.
D Using a brush, wash the water trough with hot soapy water
to which a fat-dissolving agent has been added.
D Then rinse with hot water and rub dry with a cloth or absor-
bent paper.
D Wash rust-resistant chrome nickel steel panels with hot
soapy water to which a fat-dissolving agent has been
added and rub them dry.
Water containing cooking salt or food should not dry in the boi-
ler, to prevent the danger of corrosion.
Note
D The appliance must not be sprayed with a water jet or
high-pressure cleaner.
D The floor directly in front of, near and behind the appliance
must be cleaned normally without a high-pressure cleaner.
D When cleaning the outlet pipe, do not use any sharp
objects that might damage the rubber hose.
D Never use inflammable liquids to clean the appliance
interior.
D Never use steel wool, spatulas or ordinary steel wire
brushes for cleaning the surfaces, since the deposition of
steel particles can lead to rust formation. Stainless steel
wool can possibly be used, but only in the grinding
direction.
D Never use chloric products (bleaching dye, hydrogen
chloride etc.) for cleaning chrome nickel steel, even if they
are diluted.
D Never use corrosive substances for cleaning the floor
under the appliance (e.g. hydrochloric acid). Clean the
appliance with commercial cleaning agents.
3.1 GAS BURNER
So far as is necessary, the pilot burner and main burner are
cleaned by after-sales service.
3.2 FLAME
In a visual check, the flames must be dark blue without any
upper yellow or orange tips; they must be stable and soot-free
and adhere firmly to the outlets.
If there is a lack of primary air, the flame has yellow streaks
and tips; if there is too much primary air, the flame is short,
transparent and tends to lift off the burner.
When the flame is correctly adjusted, it must not lift off or
backfire when the burner is cold as well as warm.
The flame will backfire into the inside of the burner when the
speed of the gas-air mixture through the burner outlets is too
low, particularly when the air passages are dirty.
The different ignition processes must also take place without
any delays. This concerns: ignition, arc-through and. extending
the flame over the whole burner area.
If the flame fails to meet all the requirements, cleaning or
maintenance is necessary.
OPERATING INSTRUCTIONS
Page 12 62.9680.01_UL
4. MALFUNCTION
Pasta Cooker overheats;
the power is too weak.
Water level too low. - Top up with water.
Flame smokes. Gas mix too rich.
Partially blocked burner
gaps.
- Inform Customer
Service.
Long yellow flame tips Mixing tube narrowed by
dirt.
- Inform Customer
Service.
Flame lifts off. Exit velocity too high due
to blocked burner gaps.
Pressure regulator on
gas cylinder not
operating correctly.
- Inform Customer
Service.
Flame flashes back. Mixture too lean.
Insufficient exit velocityat
burner gaps.
Soiled airways
Blocked nozzle.
- Inform Customer
Service.
No flame or flame too
small.
Blocked nozzle or mixer
tube
Blocked gas tap.
No gas.
Insufficient gas
pressure.
- Inform Customer
Service.
- Check gas tap setting.
No flame at low setting. Blocked low setting
nozzle.
- Inform Customer
Service.
No flame. Blocked burner gaps.
Blocked nozzle.
- Clean pilot burner cap.
Flame goes out after
control valve release.
Thermo-element
insufficiently heated
(dirty?)
Defective thermo-
element
Defective pilot burner
- Remove dirt; do not use
abrasive paper!
- Inform Customer
Service.
Flame too small or too
large.
Primary air ratio
adjusted.
Nozzle blocked.
- Inform Customer
Service.
Malfunction Possible cause Remedy
Pilot burner
62.8504.11 Table of nozzle - Tableau de gigleur
thermaline S90 Gas Pasta Cooker (14.3 kW)
Gas type
±1%
Nominal pres
-
sure with burner
in operation
±1%
Pressure after
the pressure
regulator with
burner in opera
-
tion
Category Main flame Small flame Ignitions burner
Air adjustment
Distance X
inch Water
Gauche
mbar
inch Water
Gauche
mbar in mm No. in mm No. No. No. in mm
Natural
gases
21
Natural
gas USA
7.0 17.4 6.0 15 A 0.116 2.95 72.7803.18 0.071 1.80 712 345064.36 0.98 25
1 106 1234
1.18 30
22
23
24
Liquid
gases
25
Propane
gas USA
11.0 27.4 10.0 25 E 0.079 2.00 72.7803.12 0.047 1.20 712 345064.21 0.94 24 1 106 1235 1.18 30
26
27
28
23
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25

Electrolux 9CHG584138 User manual

Category
Cookers
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages