Cooler Master RC-1010 Installation guide

Category
Split-system air conditioners
Type
Installation guide

This manual is also suitable for

SPLIT TYPE
ROOM AIR CONDITIONER
WALL MOUNTED
type
Models Indoor unit Outdoor unit
INVERTER
SERVICE
INSTRUCTION
R410A
ASU 9RLF
ASU12RLF
ASU15RLS
AOU 9RLFW
AOU12RLFW
AOU15RLS
CONTENTS
1. DESCRIPTION OF EACH CONTROL OPERATION
1. COOLING OPERATION................................................................................................
3. DRY OPERATION.........................................................................................................
2. HEATING OPERATION.................................................................................................
5. INDOOR FAN CONTROL..............................................................................................
4. AUTO CHANGEOVER OPERATION............................................................................
7. LOUVER CONTROL.....................................................................................................
6. OUTDOOR FAN CONTROL..........................................................................................
9. TIMER OPERATION CONTROL...................................................................................
8. COMPRESSOR CONTROL..........................................................................................
11. TEST OPERATION CONTROL...................................................................................
10. ELECTRONIC EXPANSION VALVE CONTROL........................................................
13. FOUR-WAY VALVE EXTENSION SELECT................................................................
12. PREVENT TO RESTART FOR 3 MINUTES ( 3 MINUTES ST ).................................
15. MANUAL AUTO OPERATION ( Indoor unit body operation ).....................................
14. AUTO RESTART.........................................................................................................
16. FORCED COOLING OPERATION..............................................................................
18.
MINIMUM HEAT OPERATION....................................................................................
17. COMPRESSOR PREHEATING..................................................................................
19. ECONOMY OPERATION............................................................................................
21. OFF DEFROST OPERATION CONTROL...................................................................
20.
DEFROST OPERATION CONTROL...........................................................................
01-01
01-02
01-02
01-03
01-04
01-06
01-07
01-08
01-09
01-11
01-11
01-11
01-11
01-12
01-12
01-12
01-12
01-12
01-13
01-15
22. VARIOUS PROTECTIONS.......................................................................................... 01-16
01-11
2. TROUBLE SHOOTING
2-1 ERROR DISPLAY.......................................................................................................
2-1-1 WIRED REMOTE CONTROLLER DISPLAY (OPTION)....................................
3. APPENDING DATA
2-1-2 OUTDOOR UNIT DISPLAY................................................................................
2-1-3 INDOOR UNIT DISPLAY....................................................................................
2-2 TROUBLE SHOOTING WITH ERROR CODE............................................................
2-3 TROUBLE SHOOTING WITH NO ERROR CODE.....................................................
02-01
02-01
02-02
02-03
3-1 FUNCTION SETTING.................................................................................................
3-1-1 INDOOR UNIT....................................................................................................
3-1-2 Procedures to change the Function Setting for wireless RC..............................
03-01
03-01
03-03
3-2 Thermistor Resistance Values.....................................................................................
3-2-1 INDOOR UNIT....................................................................................................
3-2-2 OUTDOOR UNIT................................................................................................
03-05
03-05
03-05
02-04
02-24
2-4 SERVICE PARTS INFORMATION.............................................................................. 02-29
1 . DESCRIPTION OF EACH
CONTROL OPERATION
R410A
WALL MOUNTED type
INVERTER
( Fig.1 : Limit of Maximum Frequency based on Outdoor Temperature )
1. COOLING OPERATION
1-1 COOLING CAPACITY CONTROL
A sensor (room temperature thermistor) built in the indoor unit body will usually perceive
difference or variation between a set temperature and present room temperature, and
controls the operation frequency of the compressor.
* If the room temperature is 4°F(2°C) higher than a set temperature, the compressor operation
frequency will attain to maximum performance.
minimum
frequency
maximum
frequency
ASU9RLF 22rps 79rps
ASU12RLF 18rps 96rps
ASU15RLS 15rps 80rps
Outside air Outside air
temperature temperature
96.8°F
(36°C)
A zone
93.2°F
(34°C)
89.6°F
(32°C)
B zone
86°F
(30°C)
69.8°F
(21°C)
C zone
66.2°F
(19°C)
D zone
Hi Me Lo Quiet
A zone 79rps 61rps 52rps 37rps
B zone 79rps 61rps 52rps 37rps
C zone 79rps 61rps 52rps 37rps
9RLF
D zone 52rps 43rps 37rps 28rps
E zone 64rps 55rps 49rps 36rps
F zone 64rps 55rps 49rps 36rps
96rps 61rps 51rps 33rps
96rps 61rps 51rps 33rps
96rps 61rps 51rps 33rps
57rps 42rps 36rps 27rps
57rps 42rps 36rps 27rps
57rps 42rps 36rps 27rps
A zone
B zone
C zone
12RLF
15RLS
D zone
E zone
F zone
80rps 45rps 37rps 29rps
80rps 45rps 37rps 29rps
80rps 45rps 37rps 29rps
47rps 37rps 31rps 22rps
47rps 37rps 31rps 22rps
47rps 37rps 31rps 22rps
A zone
B zone
C zone
D zone
E zone
F zone
( Table1 : Compressor Frequency Range )
01-01
E zone
F zone
50°F
(10°C)
32°F
(0°C)
53.6°F
(12°C)
35.6°F
(2°C)
* When the room temperature is between +4°F(+2°C) to -5°F(-2.5°C) of the setting temperature,
the compressor frequency is controlled within the range shown in Table1.
However, the maximum frequency is limited in the range shown in Figure1 based on the
fan speed mode and the outdoor temperature.
* If the room temperature is 5°F(2.5°C) lower than a set temperature, the compressor will be
stopped.
2. HEATING OPERATION
2-1 HEATING CAPACITY CONTROL
A sensor (room temperature thermistor) built in the indoor unit body will usually perceive
difference or variation between a set temperature and present room temperature, and
controls the operation frequency of the compressor.
* If the room temperature is lower by 6°F(3°C) than a set temperature, the compressor operation
frequency will attain to maximum performance.
* If the room temperature is higher 5°F(2.5°C) than a set temperatire, the compressor will be
stopped.
* When the room temperature is between +5°F(+2.5°C) to -6°F(-3°C) of the setting temperature,
the compressor frequency is controlled within the range shown in Table2.
( Table2 : Compressor Frequency Range )
01-02
minimum
frequency
maximum
frequency
ASU9RLF 22rps 99rps
ASU12RLF 18rps 130rps
ASU15RLS 15rps 119rps
3. DRY OPERATION
3-1 INDOOR UNIT CONTROL
The compressor rotation frequency shall change according to the temperature, set temperature,
and room temperature variation which the room temperature sensor of the indoor unit body has
detected as shown in the Table3.
However, after the compressor is driven, the indoor unit shall run at operation frequency of
64rps (9RLF), 61rps (12RLF), 51rps (15RLS), for a minute.
Ts+1°F
(Ts+0.5°C)
Ts-1°F
(Ts-0.5°C)
Ts-3°F
(Ts-1.5°C)
Ts+3°F
(Ts+1.5°C)
( Table3 : Compressor frequency )
( Fig.2 : Compressor Control based on Room Temperature )
Operating
frequency
37rps
28rps
0rps
9RLF
X zone
J zone
Y zone
Operating
frequency
J zone
Y zone
X zone
33rps
25rps
0rps
12RLF
Operating
frequency
J zone
Y zone
X zone
29rps
18rps
0rps
15RLS
Room Room
temperature temperature
X zone
J zone
Y zone
4. AUTO CHANGEOVER OPERATION
01-03
Operation flow chart
START
Room temp.
Room temp.
>Ts+4°F(2°C)?
COOLING OPERATION
HEATING OPERATION
YES
YES
NO
NO
NO
NO
YES
YES
TS : Setting temperature
<Ts- 4°F(2°C)?
Thermostat remains
in OFF state for 6 minutes or
longer?
System stops
or operation command other than
auto changeover operation?
NO
NO
Thermostat remains
in OFF state for 6 minutes or
longer?
System stops
or operation command other than
auto changeover operation?
YES
YES
When the air conditioner is set to the AUTO mode by remote control, operation starts in the optimum
mode from among the HEATING, COOLING, DRY and MONITORING modes. During operation, the
optimum mode is automatically switched in accordance with temperature changes. The temperature
can be set between 64°F(18°C) and 88°F(30°C) in 2°F(1°C) steps.
5. INDOOR FAN CONTROL
The airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH,
while the indoor fan only runs.
When Fan mode is set at (Auto), it operates on (MED) Fan Speed.
01-04
1. Fan speed
2. FAN OPERATION
( Table4 : Indoor Fan Speed )
Operation mode Air flow mode
Speed (rpm)
1330
1290
1160
980
Cooling/ Fan
Hi
Hi
710
600
480
1330
Me+
Me
Me
Heating
Lo
Lo
1160
930
Quiet
Quiet
680
Dry
S-Lo
X zone: 680
J zone: 660
1500
1360
1230
1050
770
600
480
1440
1230
1000
750
X zone: 750
J zone: 730
Cool air prevention
3. COOLING OPERATION
Switch the airflow [AUTO], and the indoor fan motor will run according to a room temperature,
as shown in Figure3.
On the other hand, if switched in [HIGH] [QUIET], the indoor motor will run at a constant airflow of [COOL]
operation modes QUIET, LOW, MED, HIGH,as shown in Table4.
( Fig.3 : Airflow change - over ( Cooling : AUTO ) )
When the room
temperature rises
When the room
temperature drops
TR : Room temperature
Ts : Setting temperature
TR-Ts > 4°F
(2°C)
2°F > TR-Ts
(1°C)
4°F > TR-Ts > 2°F
(2°C) (1°C)
=
TR-Ts > 5°F
(2.5°C)
=
3°F > TR-Ts
(1.5°C)
5°F > TR-Ts > 3°F
(2.5°C) (1.5°C)
=
HIGH mode
MED mode
LOW mode
ASU9RLF ASU12RLF ASU15RLS
4. DRY OPERATION
Refer to th
eT
a
ble4.
During the d
ry mode operation, the fan speed sett
ing c
an not be
c
hange
d
.
The maximum value of the indoor fan speed is set as shown in Figure5, based on the detected
temperature by the indoor heat exchanger sensor on heating mode.
(Fig.5 : Cool Air Prevention Control)
01-05
5. HEATING OPERATION
Switch the airflow [AUTO], and the indoor fan motor will run according to a room temperature,
as shown in Figure4.
Switch the airflow [AUTO] at cooling mode, and the indoor fan motor will run as shown in Figure6.
On the other hand, if switched in [HIGH] [QUIET], the indoor motor will run at a constant airflow
of [HEAT] operation modes QUIET, LOW, MED, HIGH, as shown in Table4.
6. COOL AIR PREVENTION CONTROL (Heating mode)
7. MOISTURE RETURN PREVENTION CONTROL (Cooling mode& Dry mode)
( Fig.4 : Airflow change - over ( Heating : AUTO ) )
TR-Ts > -3°F
(-1.5°C)
=
-5°F > TR-Ts
(-2.5°C)
-3°F > TR-Ts > -5°F
(-1.5°C) (-2.5°C)
=
TR-Ts > -2°F
(-1°C)
=
-4°F > TR-Ts
(-2°C)
-2°F > TR-Ts > -4°F
(-1°C) (-2°C)
=
When the room
temperature rises
When the room
temperature drops
TR : Room temperature
Ts : Setting temperature
LOW mode
MED mode
MED+ mode
107.6°F (42°C)
86°F (30°C)
93.2°F (34°C)
Indoor heat exchanger
temperature
Indoor heat exchanger
temperature
Hi
Me+
Lo
Cool air
prevention
102.2°F (39°C)
98.6°F (37°C)
98.6°F (37°C)
89.6°F (32°C)
75.2°F (24°C)
S-Lo
( Fig.6 : Indoor Fan Control )
Compressor
ON
OFF
Indoor fan
Setting air flow
Indoor fan
(as shown in Table 5)
S-Lo
OFF
10 30 60 180 60 180 60 10 30
(SEC)
( Table5 : Indoor fan speed )
X zone J zone
ASU9/ 12RLF 680rpm 660rpm
ASU15RLS 750rpm 730rpm
Y zone
0 480rpm
0 480rpm
480rpm
480rpm
Dry
Cooling
6. OUTDOOR FAN CONTROL
( Table7 : Outdoor fan speed )
*
The outdoor fan speed mentioned above depends on the compressor frequency.
(When the compressor frequency increases, the outdoor fan speed also changes to the higher
speed. When the compressor frequency decreases, the outdoor fan speed also changes to the
lower speed.)
*
After the defrost control is operated on the heating mode, the fan speed keeps at the higher speed
as table8 without relating to the compressor frequency.
01-06
( Table8 : Outdoor fan speed after the defrost )
1. Outdoor Fan Motor
2. Fan Speed
AC Motor DC Motor
ASU9/ 12RLF,15RLS
Following table shows the type of the outdoor fan motor. The control method is different
between AC motor and DC motor.
( Table6 : Type of Motor )
ASU9RLF 900rpm
Cooling Heating
ASU9RLF
ASU12RLF
ASU15RLS
Y
Z
Zone
860/ 780/ 760/ 470
900/ 760/ 720/ 680/ 470
950/ 850/ 750/ 680/ 550/ 450
1100/ 850/ 780/ 590/ 480
Refer to Fig.7
(rpm)
860/ 470/ 330
F
G
230
150
Y
Z
850/ 750/ 670/ 500
850/ 500/ 350
F
G
330
230
Y
Z
1050/ 1010/ 870/ 720/ 530
Dry
760/ 470
760/ 470
530
870/ 530/ 300
F
G
300/ 250
250/ 200
ASU12RLF 950rpm
ASU15RLS 1100rpm
( Fig.7 : Outside air temperature zone selection )
69.8°F (21°C)
50°F (10°C)
Outside air
temperature
Outside air
temperature
Z zone
Y zone
F zone
G zone
53.6°F (12°C)
35.6°F ( 2°C)
66.2°F (19°C)
32°F ( 0°C)
7. LOUVER CONTROL
1. VERTICAL LOUVER CONTROL
2. SWING OPERATION
Each time the button is pressed, the air direction range will change as follow:
(Function Range)
01-07
The vertical airflow direction is set automatically as shown, in accordance with the type of operation selected.
Cooling / Dry mode
Horizontal flow
Heating mode Downward flow
When the swing signal is received from the remote controller, the vertical louver starts to swing.
(Table9 : Swinging Range)
Air Direction RangeFig.8 :
Cooling / Dry mode
Fan mode ( )
1
2
3
4
5
6
Types of Air flow Direction Setting:
,,,,, :DuringHeating/Cooling/Drymodes
The Remote Controller's display does not change.
Use the air direction adjustments within the ranges shown above.
During AUTO mode operation, for the first a few minutes after beginning operation,
air-flow will be horizontal 1; the air direction cannot be adjusted during this period.
The air flow direction setting will temporarily become 1 when the temperature of the air -flow is
low at the start of the Heating mode.
Range
Heating mode
Fan mode ( )
The SWING operation may stop temporarily when the air conditioner’s fan is not operating,
or when operating at very low speeds.
8. COMPRESSOR CONTROL
1. OPEARTION FREQUENCY RANGE
The operation frequency of the compressor is different based on the operation mode as
shown in the table10.
Cooling Heating
Min Max Min Max Min Max
Dry
ASU9RLF
ASU12RLF
22rps 79rps 22rps 99rps 28rps 37rps
18rps 96rps 18rps 130rps 25rps 33rps
ASU15RLS 15rps 80rps 15rps 119rps 18rps 29rps
ASU9RLF
70rps 82rps 92rps 96rps 96rps 96rps
ASU12RLF
56rps 74rps 87rps 97rps 108rps 119rps
ASU15RLS
40rps 57rps 72rps 80rps 101rps 110rps
80sec 140sec 200sec 380sec 440sec 440sec
(Table10 : Compressor Operation Frequency Range)
2. OPEARTION FREQUENCY CONTROL AT START UP
The compressor frequency soon after the start-up is controlled as shown in the Figure9.
(Fig.9 : Compressor Control at Start-up)
Time
Time Time Time
Time
Time
(Frequency)
(Time)
Frequency
Frequency
Frequency Frequency
Frequency
Frequency
Time Time
Time Time Time Time
Frequency
Frequency
Frequency
Frequency
Frequency
Frequency
01-08
ASU9RLF
80sec 140sec 200sec 380sec 440sec 500sec
ASU12RLF
80sec 110sec 140sec 200sec 350sec 410sec
ASU15RLS
9. TIMER OPEARTION CONTROL
1. OPEARTION FREQUENCY RANGE
The table11 shows the available timer setting based on the product model.
ON TIMER / OFF TIMER PROGRAM TIMER SLEEP TIMER
ASU9/ 12RLF,15RLS
OFF timer : When the clock reaches the set time, the air conditioner will be turned off.
Operation mode
Stop mode
Set time of timer
ON timer : When the clock reaches the set time, the air conditioner will be turned on.
Operation mode
Stop mode
Set time of timer
The program timer allows the OFF timer and ON timer to be used in combination one time.
Operation mode
Operation will start from the timer setting (either OFF timer or ON timer) whichever is closest
to the clock's current timer setting.
The order of operations is indicated by the arrow in the remote control unit's display.
SLEEP timer operation cannot be combined with ON timer operation.
(Table11 : Timer Setting)
2. PROGRAM TIMER
Stop mode
Stop mode
Stop mode
Operation mode
Operation mode
Set time
Set time Set time Set time
01-09
3. SLEEP TIMER
If the sleep is set, the room temperature is monitored and the operation is stopped automatically.
If the operation mode or the set temperature is change after the sleep timer is set, the operation is
continued according to the changed setting of the sleep timer from that time ON.
Set temperature rises
( Ts : Set temperature )
Stop of operation
Set temperature lowers
( Ts : Set temperature )
Ts
Stop of operation
In the cooling operation mode
When the sleep timer is set, the setting temperature is increased 2°F(1°C).
It increases the setting temperature another 2°F(1°C) after 1 hour.
After that, the setting temperature is not changed and the operation is stopped at the time
of timer setting.
Ts
+2°F (1°C)
+4°F (2°C)
Set
60min
In the heating operation mode
When the sleep timer is set, the setting temperature is decreased 2°F(1°C).
It decreases the setting temperature another 2°F(1°C) every 30 minutes.
Upon lowering 8°F(4°C) the setting temperature is not changed and the operation stops at
the time of timer setting.
-8°F (-4°C)
-6°F (-3°C)
-4°F (-2°C)
-2°F (-1°C)
Set
30min
30min
30min
01-10
10. ELECTRONIC EXPANSION VALVE CONTROL
The most proper opening of the electronic expansion valve is calculated and controlled under the
present operating condition based on the Table12.
The compressor frequency, the temperatures detected by the discharge temperature sensor, the
indoor heat exchanger sensor, the outdoor heat exchanger sensor,
and the outdoor temperature sensor.
The expansion valve is set at 480 pulses after 110 seconds of stopping compressor.
At the time of supplying the power to the outdoor unit, the initialization of the electronic
expansion valve is operated (528 pulses are input to the closing direction).
11. TEST OPERATION CONTROL
Under the condition where the air conditioner runs, press the test run button of the remote
control, and the test operation control mode will appear. During test running, the operation lamp
and timer lamp of the air conditioner body twinkle simultaneously. Set the test operation mode,
and the compressor will continue to run regardless of whether the room temperature sensor detects.
The test operation mode is released if 60 minutes have passed after setting up the test operation.
The compressor won't enter operation status for 2 minutes and 20 seconds after the compressor is
stopped, even if any operation is given.
At the time when the air conditioner is switched from the cooling mode to heating mode, the
compressor is stopped, and the four-way valve is switched in 2 minutes and 20 seconds later after
the compressor stopped.
When the power was interrupted by a power failure, etc. during operation, the operation contents
at that time are memorized and when power is recovered, operation is automatically started with
the memorized operation contents.
When the power is interrupted and recovered during timer operation, since the timer operation time
is shifted by the time the power was interrupted, an alarm is given by blinking (7 sec ON/2 sec OFF)
the indoor unit body timer lamp.
[Operation contents memorized when the power is interrupted]
Operation mode
Set temperature
Set air flow
Timer mode and timer time
Set air flow Direction
Swing
ECONOMY operation
MINIMUM HEAT operation
12. PREVENT TO RESTART FOR 3 MINUTES ( 3 MINUTES ST )
13. FOUR-WAY VALVE EXTENSION SELECT
14. AUTO RESTART
01-11
Cooling / Dry mode
Heating mode
Cooling / Dry mode
Heating mode
ASU9/ 12RLF
ASU15RLS
Operation mode Pulse range
between 60 to 480 pulses.
between 60 to 480 pulses.
between 60 to 480 pulses.
between 45 to 480 pulses.
Table12 : The pulse range of the electronic expansion valve control
15. MANUAL AUTO OPERATION (Indoor unit body operation)
If MANUAL AUTO Button is set, the operation is controlled as shown in Table13.
If the remote control is lost or battery power dissipated, this function will work without the remote control.
OPERATION MODE Auto changeover
FAN CONT. MODE Auto
TIMER MODE Continuous
SETTING TEMP. 75.2°F (24°C)
SETTING LOUVER Standard
SWING
ECONOMY
OFF
OFF
When the outdoor temperature is lower than 68°F(20°C) and the heating operation has been
stopped for 30 minutes, power is applied to the compressor and the compressor is heated.
(By heating the compressor, warm air is quickly discharged when operation is started.)
When operation was started and when the outdoor temperature rises to 77°F(25°C) or greater,
preheating is ended.
(Table13)
(No timer setting available)
17. COMPRESSOR PREHEATING
01-12
Forced cooling operation
Cooling
16. FORCED COOLING OPERATION
Forced cooling operation is started when pressing MANUAL AUTO button for 10 seconds or more.
During the forced cooling operation, it operates regardless of room temperature sensor.
Operation LED and timer LED blink during the forced cooling operation. They blink for 1 second ON
and 1 second OFF on both operation LED and timer LED (same as test operation).
Forced cooling operation is released after 60 minutes of starting operation.
The FORCED COOLING OPERATION will start as shown in Table13.
Hi
Horizontal
OFF
Room Temp is not controlled
Manual auto operation
-
-
18. MINIMUM HEAT OPERATION
The MINIMUM HEAT operation functions by pressing MIN.HEAT button on the remote controller.
The MINIMUM HEAT operation is almost the same operation as below settings.
Mode Heating
Setting temperature 50°F (10°C)
Fan mode AUTO
( Table14 )
19. ECONOMY OPERATION
The ECONOMY operation functions by pressing ECONOMY button on the remote controller.
The ECONOMY operation is almost the same operation as below settings.
Mode Cooling/ Dry Heating
Target temperature Setting temp.+2°F Setting temp.-2°F
(+1°C) (-1°C)
( Table15 )
20. DEFROST OPERATION CONTROL
01-13
1. CONDITION OF STARTING THE DEFROST OPERATION
The defrost operation starts as shown in the following Table 16.
2. CONDITION OF THE DEFROST OPERATION COMPLETION
Release Condition
Outdoor heat exchanger temperature sensor value is higher than
+60.8°F (+16°C) or Compressor operation time has passed 15 minutes.
(Table 16 : Condition of starting Defrost Operation)
Defrost operation is released when the conditions become as shown in Table 17.
(Table 17 : Defrost Release Condition)
Integrating defrost
If the compressor continuous operation time is less than 10 minutes,
the OFF number of the compressor is counted.
If any defrost operated, the compressor OFF count is cleared.
Normal defrost
Compressor integrating operation time
Less than 25 minutes More than 25 minutes
Does not operate
Outdoor heat exchanger temp. < 1.4°F (-17°C)
(at outside air temp. > 14°F (-10°C))
Outdoor heat exchanger temp. < Outside air temp.- 12.6°F (7°C)
or Outdoor heat exchanger temp. < - 4°F (-20°C)
(at outside air temp. < 14°F (-10°C))
More than 240 minutes
(For continuous operation)
Less than 10 minutes
( For
intermittent operation )
Compressor integrating operation time
Outdoor heat exchanger temp.
below 26.6°F (-3°C)
OFF count of the compressor
40 times
=
=
=
=
01-14
Outdoor fan : OFF
Compressor speed:0rps
EEV : 480pulse
4-way valve : OFF
Compressor speed : 90rps (09/ 12)
70rps (15)
3. Defrost Flow Chart
The defrosting shall proceed by the integrating operation time, outdoor temperature
and outdoor heat exchanger temperature as follows.
(Not defrosted for 10 minutes)
Heating operation start : Compressor ON
Outdoor HEX temp.: Over 60.8°F(16°C)
or
Compressor ON time: Maximum 15 minutes
Defrost end
Outdoor HEX temp.
Below 1.4°F
(-17°C)
Outdoor HEX temp.
- Outside air temp.
Below - 12.6°F(7°C)
or
Outdoor HEX temp.
Below - 4°F(-20°C)
Compressor
integrating
operation:
Over 240 minutes
Integrating defrost
Defrost Indicator:
[Operation lamp]
7 sec ON / 2 sec OFF
Defrost start
Outdoor HEX temp.
Below 26.6°F(-3°C)
Compressor
OFF count :
40 times
Normal defrost
Outside air temp. > 14°F
(-10°C)
Outside air temp. < 14°F
(-10°C)
=
Intermittent operation Continuous operation
21. OFF DEFROST OPEARTION CONTROL
1. OFF DEFROST OPERATION CONDITION
When operation stops in the [Heating operation] mode, if frost is adhered to the outdoor unit heat
exchanger, the defrost operation will proceed automatically. In this time, if indoor unit defrost lamp
lighting, the outdoor unit will allow the heat exchanger to defrost, and then stop.
In heating operation, the outdoor heat exchanger temperature is less than 24.8°F (-4°C), and
compressor operation integrating time lasts for more than 30 minutes.
OFF Defrost Flow Chart
Heating operation stop
Outdoor heat exchanger temperature:
Below 24.8°F(-4°C)
and
Compressor integrating operation:
Over 30 minutes
Defrost start
Defrost Indicater:
[Defrost lamp]
Lighting
Outdoor heat exchanger temperature:
Over 60.8°F (16°C) or
Compressor ON time: Over 15 minutes
Defrost end
2. OFF DEFROST END CONDITION
Release Condition
Outdoor heat exchanger temperature sensor value is higher than 60.8°F (16°C)
or Compressor operation time has passed 15 minutes.
01-15
22. VARIOUS PROTECTIONS
1. DISCHARGE GAS TEMPERATURE OVERRISE PREVENSION CONTROL
The discharge gas thermosensor (discharge thermistor : Outdoor side) will detect discharge gas
temperature.
ASU9/ 12RLF,15RLS
219.2°F
(104°C)
213.8°F
(101°C)
230°F
(110°C)
When the discharge temperature becomes higher than Temperature ,the compressor frequency
is decreased 20rps, and it continues to decrease the frequency for 20rps every 120 seconds until
the temperature becomes lower than Temperature .
When the discharge temperature becomes lower than Temperature , the control of the control of
the compressor frequency is released.
When the discharge temperature becomes higher than Temperature ,the compressor is stopped
and the indoor unit LED starts blinking.
(Table18 : Discharge Temperature Over Rise Prevension Control / Release Temperature)
Temperature
Temperature
Temperature
2. CURRENT RELEASE CONTROL
The compressor frequency is controlled so that the outdoor unit input current does not exceeds
the current limit velue that was set up with the outdoor temperature.
The compressor frequency returns to the designated frequency of the indoor unit at the time
when the frequency becomes lower than the release value.
(Table19 : Current Release Operation Value / Release Value)
01-16
[ Heating ]
OT (Control / Release)
5.5A/ 5.0A
6.0A/ 5.5A
7.0A/ 6.5A
7.0A/ 6.5A
5.5A/ 5.0A
7.0A/ 6.5A
7.5A/ 7.0A
8.5A/ 8.0A
62.6°F(17°C)
53.6°F(12°C)
OT : Outdoor Temperature
41°F(5°C)
62.6°F(17°C)
53.6°F(12°C)
41°F(5°C)
62.6°F(17°C)
53.6°F(12°C)
41°F(5°C)
ASU9RLF
OT (Control / Release)
OT : Outdoor Temperature
ASU12RLF
OT (Control / Release)
3.5A/ 3.0A
4.0A/ 3.5A
5.5A/ 5.0A
4.0A/ 3.5A
5.0A/ 4.5A
6.0A/ 5.5A
114.8°F(46°C)
104°F(40°C)
114.8°F(46°C)
104°F(40°C)
114.8°F(46°C)
104°F(40°C)
OT : Outdoor Temperature
ASU9RLF
OT (Control / Release)
OT : Outdoor Temperature
ASU12RLF
[ Cooling ]
7.0A/ 6.5A
9.0A/ 8.5A
10.0A/ 9.0A
10.0A/ 9.5A
OT (Control / Release)
OT : Outdoor Temperature
ASU15RLS
4.5A/ 3.0A
6.0A/ 5.5A
8.5A/ 8.0A
OT (Control / Release)
OT : Outdoor Temperature
ASU15RLS
3. ANTIFREEZING CONTROL (Cooling and Dry mode)
The compressor frequency is decrease on cooling & dry mode when the indoor heat exchanger
temperature sensor detects the temperature lower than Temperature .
Then, the anti-freezing control is released when it becomes higher than Temperature .
(Table19 : Anti-freezing Protection Operation / Release Temperature)
4. COOLING PRESSURE OVERRISE PROTECTION
When the outdoor unit heat exchange sensor temperature rises to 152.6°F (67°C) or greater,
the compressor and the outdoor fan motor are stopped and trouble display is performed.
5. HIGH TEMPERATURE RELEASE CONTROL ( HEATING MODE )
On heating mode, the compressor frequency is controlled as following based on the
detection value of the indoor heat exchanger temperature sensor.
01-17
Indoor heat exchange
temperature
[ Control System ]
It returns to the normal operation
127.4°F
(53°C)
122°F
(50°C)
Outdoor temperature
Over than 50°F(10°C) *1
or 53.6°F(12°C) *2
Less than 50°F(10°C) *1
or 53.6°F(12°C) *2
*1. When the temperature rises.
*2. When the temperature drops.
39.2°F (4°C)
44.6°F (7°C)
55.4°F (13°C)
Temperature Temperature
The compressor frequency is
decreased 3rps every 60seconds.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Cooler Master RC-1010 Installation guide

Category
Split-system air conditioners
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI