Moffat E33D5 Operating instructions

Category
Microwaves
Type
Operating instructions
246963-1
Installation and Operation Manual
E 3 3 D 5 - 3 P h a s e M o d e l
2 Speed Fan
Moisture Mode
Multi-Stage Cooking
Optional Core Temp Probe
The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless authorized previously in writing
by the manufacturer.
In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change the specifications and design
without prior notice.
© Copyright Moffat Ltd. March 2019.
Moffat Limited
Rolleston 7675
New Zealand
AUSTRALIA
Moffat Pty Limited
Web: www.moffat.com.au
E.Mail: vsales@moffat.com.au
Main Office: (tel) +61 (03) 9518 3888
(fax) +61 (03) 9518 3838
Service: (tel): 1800 622 216
Spares: (tel): 1800 337 963
Customer Service: (tel): 1800 335 315
(fax): 1800 350 281
CANADA
Serve Canada
Web: www.servecanada.com
E.Mail: info@servecanada.com
Sales: (tel): 800 551 8795 (Toll Free)
Service: (tel): 800 263 1455 (Toll Free)
NEW ZEALAND
Moffat Limited
Web: www.moffat.co.nz
E.Mail: sales@moffat.co.nz
Main Office: (tel): 0800 663328
UNITED KINGDOM
Blue Seal
Web: www.blue-seal.co.uk
E.Mail: sales@blue-seal.co.uk
Sales: (tel): +44 121 327 5575
(fax): +44 121 327 9711
Spares: (tel): +44 121 322 6640
(fax): +44 121 327 9201
Service: (tel): +44 121 322 6644
(fax): +44 121 327 6257
UNITED STATES
Moffat
Web: www.moffat.com
Sales: (tel): 1-800 551 8795 (Toll Free)
(tel): 336 661 1556
(fax): 336 661 9546
Service: (tel): 866 673 7937 (Toll Free)
REST OF WORLD
Moffat Limited
Web: www.moffat.co.nz
Contents List
Safety Information
Installation Requirements
Unpacking
Location
Clearances
Stand Mounted Ovens
Electrical Connection
Water Connection
Recommended Water Specifications
Positioning and Levelling of Oven
Initial Start-Up
Commissioning
Operation Guide
Cooking in Manual Mode
Cooking in Manual Mode using Core Temp Probe
Cooking in Program Mode
Programs
Parameters
Programs Revision Numbering
Files
Changing Operator Settings
Operator Settings
Cleaning Guidelines
Oven Cleaning
Periodic Maintenance
Introduction
2
Before using your new oven, please read this instruction manual
carefully, pay particular attention to any information labelled
WARNING, CAUTION, IMPORTANTor NOTEin this manual.
Indicates a hazardous situation
which, if not avoided, will result in
death or serious injury.
Indicates a hazardous situation
which, if not avoided, will result in
minor or moderate injury.
If you are unsure of any aspect of the installation, instructions or
performance of your oven, contact your TURBOFAN dealer promptly.
In many cases a phone call could answer your question.
Should you contact your TURBOFAN dealer on any matter concerning
this oven, please have the information provided opposite, readily
available.
This manual must be kept by the owner for future reference.
A record of
Date of Purchase,
Date of Installation
and
Serial
Number of the oven
should be recorded in the area provided
below.
The serial number of this oven can be found on the
Technical Data Plate located on the front right hand side
panel, see diagram in Installation Section’.
For your safety, please pay attention to the following symbols
marked on the appliance.
- Risk of electric shock.
No user serviceable parts inside.
Qualified service person access only.
Disconnect from power before servicing.
Specifications
3
E33D5
Oven Power Ratings 380V, 50Hz, 3P+N+E, 6.0kW.
L1 : 0.7A, L2 : 13.2A, L3 : 13.2A
Oven Tray Details Tray Capacity 5 Shelf, 1/1 GN Pan.
Tray Spacing 85mm / 31/3”.
Water Connection Max Water Pressure 80psi / 550kPa.
Connection Size 3/4BSP.
NOTE: If the Moisture Mode cooking option is not required, the oven does not need to
be connected to a water supply.
Installation
4
1. Remove all packaging and transit protection including all
protective plastic coating from the exterior stainless steel
panels.
2. Check the oven and supplied parts for damage. Report any
damage immediately to the carrier and distributor.
3. Check that the following parts have been supplied with your
oven:-
4 x Leg Adjustable.
4. Report any deficiencies to the distributor who supplied your
oven.
5. Securely fit the 4 legs supplied with the oven.
6. Check that the available electrical supply is correct to that
shown on the Technical Data Plate located on the front right
hand side panel.
Also refer to Specificationssection, Oven
Specifications Tableon previous page.
1. Position the oven in its approximate working position.
2. The unit should be positioned so that the control panel
and oven shelves are easily reachable for loading and
unloading.
To ensure correct ventilation for the motor and controls, the
following minimum installation clearances are to be adhered to:-
Top 200mm / 8”.
Rear 50mm / 2”.
Left-hand side 50mm / 2”.
Right-hand side 75mm / 3”.
Clearance From Source of Heat.
A minimum distance of 300mm (12”) from the appliance
sides is required.
NOTE: Fixed installations require at least 500mm (20”)
clearance for service access.
For stand mounted ovens, the oven feet are used to level the oven
on the stand. Refer to the instructions supplied with separately
ordered stands for mounting details.
The vent located on the top of the oven must NOT be
obstructed.
Installation shall comply with local electrical, health and safety requirements.
It is most important that this oven is installed correctly and that oven operation is correct before use.
If you have any questions regarding the proper installation and / or operation of this oven, please contact your local
Turbofan distributor.
Technical Data Plate - Location
Oven Vent Location
Installation
5
RCD (Residual Current Device) / GFCI (Ground-Fault Circuit-
Interrupter) protection of the power supply to this appliance is
recommended.
Each oven should be connected to an adequately protected power
supply with an appropriate three wire power cord.
An isolation switch must be mounted adjacent to, but not behind
the oven and must be readily accessible to the operator. This
switch must be clearly marked and readily accessible in case of fire.
Check the electricity supply is correct to as shown on the Technical
Data Plate on the front right hand corner of the oven side panel.
NOTE: All electrical connections must only be carried out by
a suitably qualified person.
1. Remove oven right hand side panel.
2. Bring the supply cable up through the grommet at the back of
oven and through the compression gland on the electrical
switchgear panel.
3. Connect the mains supply to the appropriately marked
terminals on the terminal block.
NOTE: If the Moisture Mode cooking option is not required,
the oven does not need to be connected to a water
supply.
1. Tighten the 2 screws securing the
water connection to the rear of the
oven. (These have purposely been
left loose to prevent damage to the
water connection during transit).
2. Connect a cold water supply to the
water inlet (R ¾Connector) on the
oven.
NOTE:
For USA / Canada / Mexico, the supplied ¾ GHT Brass
Adaptor and Washer should be used to connect a water
supply to the oven water inlet.
- Max Inlet Pressure 80psi / 550kPa.
3. Turn On the water supply and check for leaks.
In order to prevent corrosion or scaling in the oven and water
system due to supplying water that is either too soft or too hard,
the following recommendations should be used as a guideline.
Hardness: Between 60 and 90ppm.
PH: Greater than 7.5.
Chlorides: Less than 30ppm.
This oven must be earthed / grounded.
1. Correctly locate the oven into its final operating position and
using a spirit level, adjust the oven feet so that the oven is level
and at the correct height.
Before using the new oven;
1. When using the oven for the first time, operate oven for about
1 hour at 200°C / 400°F to remove any fumes or odours which
may be present.
2. Please refer to the Operation Section of this manual for details
on how to correctly operate and shutdown the oven.
Before leaving the new installation;
1. Check the oven functions in accordance with the operating
instructions specified in the Operationsection of this manual.
2. Ensure that the operator has been instructed in the areas of
correct operation and shutdown procedure for the appliance.
NOTE: If it is not possible to get appliance to operate
correctly, turn Offpower at the mains supply and
contact supplier of this appliance.
Tighten Screws.
Operation
6
This oven is intended for use in a commercial kitchen and must only be put to the use for which it was intended, i.e. cooking food
product. To use this oven correctly please read the following sections carefully:-
Temperature Display -
Shows pre-set chamber temperature.
When used with the Tempkey,
display shows actual oven temperature for 5
seconds.
Shows cooking programs and error codes.
SteamKey and LED -
Used to set moisture level or to
provide a manual injection of moisture
when in Manual Moisture Mode.
LED is Onwhen automatic moisture injection is
set or when moisture is manually injected.
Temperature Adjustment Control
Time Display -
Shows cook time in full minutes only
from 180 - 10, and in minutes and seconds for
the final 10 minutes.
NOTE:
In Core Temp Mode, time display alternates
between CP and set core probe
temperature.
On-Off/LightKey and LED -
A dual-function key:
Press On-Off/Lightkey once to turn
the oven On
When oven is turned On’, press On-Off/Light
key to switch oven light On-Off’.
Press and hold On-Off/Lightkey for 1.5 seconds
to turn the oven Off’.
Time Adjustment Control
NOTE: In Core Temp Mode, Timerknob is
used to set core probe temperature.
ProgramKey and LED -
Used to select cooking programs, and
to set program parameters.
TempKey and LED -
Displays actual oven temperature for 5
seconds on Temperature Display. LED
Onwhen heating element is on
(heating indicator).
LED flashes when Upper Display is showing
actual temperature.
NOTE:
In Core Temp Mode, this key is used to
display Actual Oven Temperature (Upper
Display) and actual Core Probe Temperature
(Lower Display).
Fan LoSpeed Key and LED -
Switches oven fan from high to low
speed. LED is Onwhen fan is in Low
Speed Mode. When LED is Off’, fan is
in High Speed Mode.
Timer-Start/StopKey & LED -
The Timer-Start/Stopkey is used to
control the following functions:-
Cancelling Alarm (All Modes).
Starting Core Temp Mode (Core Temp
Mode).
Starting Timer (Manual Mode).
Re-Setting Timer (Manual Mode).
Starting Program (Program Mode).
Cancelling and Re-Setting Program
(Program Mode).
Core Probe Connection Point.
Operation
7
There are 6 levels of pre-set moisture injection.
Each level defines the number of moisture injection pulses per
moisture cycle during oven operation.
H-0 Manual Moisture Mode. Automatic Moisture Injection is Off’.
Pressing Steamkey in this mode will inject 1 shot of steam
into the oven, ie, no steam injection without user input.
H-1 Level 1. - Minimum automatic moisture injection setting. One
moisture pulse per moisture cycle.
H-2 Level 2.
H-3 Level 3.
H-4 Level 4.
H-5 Level 5. - Maximum automatic moisture injection setting.
Five moisture pulses per moisture cycle.
Selecting Moisture Mode
Press Steamkey to activate Moisture Mode. Steamkey
LED will illuminate when Moisture Mode is On’. Moisture
Mode will operate at the preset level during the cooking
cycle.
When Moisture Mode H-0 is selected, a shot of steam is
available whenever the oven is running, by pressing the
Steamkey.
When Moisture Mode H-1 to H-5 are selected, these
moisture modes will only operate when a program is run-
ning, Core Temp Probe Mode has been selected or when a
timer is running in Manual Mode.
When setting Moisture level, consider the Oven Set
Temperature. If set BELOW 100°C (212°F), water may pool
in oven as temperature will be too low to create steam.
Changing Moisture Mode Level
Press and hold the Steam Key until the H-Xlevel is
displayed and flashing in the upper display.
Rotate the Temp Knob -/+ to select Moisture Mode level
required.
Press the Steamkey to confirm setting.
The MoistureMode level can be changed at anytime during
operation by following the setting method as described above.
An Optional Core Temp Probe Kit #236060 is available for
this oven.
This allows use of the Core Probe Cooking feature of this oven.
When the core probe is fitted to the connection point on control
panel side, the timer function and display becomes the core temp
probe temperature setting and display. Cooking completion is then
determined by the core temp probe reaching the set core probe
temperature.
To enable Core Probe Cooking Mode plug in the Core Probe.
The Timer Display will then change to 'CP' (Core Probe).
The Timer Knob function will then be for Core Temp setting.
To disable Core Probe Cooking Mode, unplug the Core Probe.
The Timer Display and Knob will return to time function.
In Manual mode the ovens settings are.
- Temperature - 50-250C / 150-550F.
- Timer setting - 0-180min or Infinite.
- Fan Speed setting - Hi / Lo.
- Moisture Mode settings - Off / On-Level.
- Oven lights - Off / On.
An Optional Core Probe can also be used in Manual Mode.
In Program Mode 20 Programs are able to be used.
In each program the following settings are possible.
- Temperature - 50-250C / 150-550F.
- Time - 0-180min or Infinite.
- Fan Speed - Hi/ Lo.
- Moisture Mode - Off / On-level.
3 cooking stages can also be set in each of the 20 programs.
- All settings can be changed between cooking stages.
- At completion of each stage an end of stage alarm can also
be set.
Optional Core Probe can also be used in Program Mode.
Changing between Manual to Program Modes
Press Programkey to select Program Mode. The LED
will illuminate showing Program Mode now set.
Press ProgramKey to return to Manual mode.
This oven features a 2 speed fan.
Hi Speed - This is the default operating speed.
- Hi Fan should be used for most applications.
- Hi Fan provides the fastest cooking time and evenness
throughout oven.
Lo Speed - This is the optional setting.
- Lo Fan speed is selected using the Fan Lo key.
- Lo Fan provides slower cooking with less fan affect on
the product.
- Lo Fan should be used on delicate products such as
cake and muffin.
On start-up, the oven will always default to normal Hi speed fan.
In Manual Mode, fan speed can be changed at any time during use.
In Program Mode, fan speed can be pre-set and each cooking stage
can have a different fan speed.
Changing the Fan Speed
Press FAN LOkey to change to Lo Fan speed. LED will
illuminate showing Lo Fan speed is now set.
Press FAN LOkey to change back to Hi Speed fan.
Operation
8
On oven start-up the controller defaults to the following settings:-
Oven Temperature is set to 150°C (325°F). Refer Controller - Operator Settingssection to change this start-up temperature.
Oven Timer is not set, display shows - - -.
Moisture Setting is setting to Manual Injection.
Fan Speed is set to Hi Speed.
1. SET OVEN TEMPERATURE.
Rotate Tempknob to select temperature required.
+ to increase the temperature (Max. 260°C / 500°F).
- to decrease the temperature (Min. 60°C / 140°F).
The oven will commence heating to the displayed set temperature.
NOTE: The oven can be used without using the timer.
2. SET TIMER.
Rotate Timerknob to select time required.
+ to increase the time (Max. 180 minutes).
- to decrease the time (Min. 1 minute).
NOTE: Timer can be set to Infinity . If timer is set to Infinity’, timer will
count elapsed time to a max of 999 minutes and elapsed time will be
shown on the Lower Display.
3. SET MOISTURE MODE.
Press and hold Steamkey for 3 seconds.
Rotate Tempknob to select desired moisture level (H-0 to H-5).
Press Steamkey to confirm settings.
NOTE: Refer to Moisture Mode Settingsat start of this section for additional
explanation of moisture level adjustments.
4. SET FAN SPEED.
Press Fan Lokey, to change fan speed. Fan LoLED will illuminate when
fan low speed is selected.
5. STARTING TIMER.
Press Timer-Start/Stopkey to start timer operation. LED will illuminate to indicate the
timer is running.
Press and hold Timer-Start/Stopkey for 3 seconds to cancel timer.
6. CANCELLING TIME UPALARM (COOKING TIME COMPLETED).
When the set Cooking Time is completed, alarm will sound and Lower Display flashes.
- Press Timer-Start/Stopkey to cancel alarm, oven will continue cooking at Oven Set Temperature. Display will revert to Set
Temperature and Time.
- Alternatively, open oven door to cancel alarm and turn Offfan and heating. Close oven door to resume cooking at Oven
Set Temperature. Display will revert to Set Temperature and Time.
NOTE: Any of the above settings can be adjusted during the cooking operation by using the above controls and keys.
Viewing Actual Oven Temperature. Press Tempkey during cooking, Oven Actual Temperature will display on Upper
Display for 5 seconds and then will revert to displaying Oven Set Temperature.
SteamLED will
illuminate when
automated
Moisture Mode is
set (H-1-H-5) or
during each
moisture
injection in H-0.
Fan LoLED is
Onwhen oven
fan is operating
at low speed.
Timer-Start/
StopLED is
steady Onwhen
Timer is running.
TempLED will
remain Onuntil
oven reaches Set
Temperature.
Operation
9
On oven start-up the controller defaults to the following settings:-
Oven Temperature is set to 150°C (325°F). Refer Controller - Operator Settingssection to change this start-up temperature.
Oven Timer is not set, display shows - - -.
Moisture Setting is setting to Manual Injection.
Fan Speed is set to Hi Speed.
1. CONNECT CORE TEMP PROBE.
Connect Core Temp Probe to connector on lower right side of
control panel, will be displayed on Lower Display.
2. SET OVEN TEMPERATURE.
Rotate Tempknob to select temperature required.
+ to increase the temperature (Max. 260°C / 500°F).
- to decrease the temperature (Min. 60°C / 140°F).
The oven will commence heating to the displayed set temperature.
3. SET CORE PROBE TEMPERATURE.
Rotate Timer Knob to set the desired core probe temperature.
+ to increase temperature (Max. 90°C / 194°F).
- to decrease temperature (Min. 50°C / 122°F).
Once Core Probe Set Temperature is set, Lower Display will alternately flash
between and Core Probe Set Temperature.
Timer-Start/StopLED is Off’, indicating that cooking has not yet started.
4. SET MOISTURE MODE.
Press and hold Steamkey for 3 seconds.
Rotate Tempknob to select desired moisture level (H-0 to H-5).
Press Steamkey to confirm settings.
NOTE: Refer to Moisture Mode Settingsat start of this section for additional
explanation of moisture level adjustments.
5. SET FAN SPEED.
Press Fan Lokey, to change fan speed. Fan LoLED will illuminate when fan
low speed is selected.
6. START CORE TEMP MODE COOKING.
Press Timer-Start/Stopkey to start Core Temp Mode cooking. Timer-Start/StopLED is Onduring Core Temp Mode
cooking. Lower Display will alternately flash between and Core Probe Set Temperature during cooking.
7. CANCELLING CORE TEMP ALARM (CORE TEMP SETTING REACHED - COOKING COMPLETE).
When Core Probe Set Temperature is reached, an alarm will sound and the Lower Display will flash.
- Press Timer-Start/Stopkey to cancel alarm, oven will continue cooking at Oven Set Temperature. Display will show Oven
Set Temperature and Core Probe Set Temperature.
- Alternatively, open oven door to cancel alarm and turn Offfan and heating. Close oven door to resume cooking at Oven
Set Temperature. The display will revert to the Oven and Core Probe Set Temperatures.
NOTE: Any of the above settings can be adjusted during cooking operation by using the above controls and keys.
Viewing Actual Oven and Core Temperatures. During cooking, press Tempkey to check Oven Actual
Temperature (Upper Display) and Core Probe Actual Temperature (Lower Display). Actual temperatures will display for 5
seconds before display reverts to show Oven Set Temperature (Upper Display) and Core Probe Set Temp (Lower Display).
Exiting Core Temp Cooking Mode. Disconnect Core Probe from connector on low er right side of control
panel. Lower Display and Timerknob will revert to normal Timer Mode operation.
In Core Temp
Mode, the Lower
Display will
alternate
between CPand
the Core Probe
Set Temperature.
Timer-Start/
StopLED is On
when Cook Mode
in Progress.
In Core Temp
Mode, pressing
Tempkey will
also display Core
Probe Actual
Temperature on
Lower Display.
In Core Temp
Mode, the Timer
knob is used to
set Core Probe
Temperature.
Operation
10
The oven can be pre-programmed with up to 20 Programs; each program can contain a maximum of 3 stages. When you receive your oven,
the controller is not pre-programmed.
1. SELECTING A PROGRAM.
Press Programkey.
Upper Display will show program number selected.
+ to scroll forward through programs.
- to scroll backward through programs.
Lower Display will show , oven is Pre-Heating’.
Program cannot be started until pre-heating is completed.
2. OVEN READY.
Lower Display will show when oven is up to pre-heat temperature and an
alarm will sound.
Load product into oven.
3. CONNECT CORE TEMP PROBE (IF REQUIRED).
Connect Core Temp Probe to connector on lower right side of control panel,
will be displayed on Lower Display.
NOTE: A Core Temp Probe can be used as part of a multi-stage cooking program.
If a program reaches a Stage that requires a Core Temp Probe and no Core
Temp Probe is connected, an error alarm will sound and CPwill flash on
Lower Display. The program is automatically paused until the Core Temp
Probe is connected. Once the probe is connected to the control panel and
inserted into the food product, press the Timer-Start/Stopkey to resume
the program.
4. START PROGRAM.
Press Timer-Start/Stopkey to start cooking program.
Pressing and holding Timer-Start/Stopkey for 3 seconds will cancel the program and return to the Preset Program.
During Program Operation the Upper and Lower Displays will show the following:-
Upper Display shows Program Number, e.g.
Lower Display will show either,
- Total Time Remaining in Program.
OR
- Total Elapsed Time of Program (if any Program Stages are set to CP or InF).
OR
- Alternate between CPand Core Probe Set Temp (if presently in a Core Probe Stage).
5. CANCELLING PROGRAM TIME UPALARM (COOKING TIME COMPLETED).
When program is completed, the alarm will sound.
To cancel alarm, press Timer-Start/Stop’, oven will continue to cook at Oven Set Temperature. Display will revert to
Program Number (Upper Display) and Total Program Time (Lower Display).
Alternatively, open oven door to cancel alarm and turn Offfan and heating. Close oven door to resume cooking at Oven
Set Temperature. Display will revert to Program Number (Upper Display) and Total Program Time remaining (Lower
Display).
ProgramLED is
Onwhen Oven
operating in
Programs Mode.
Operation
11
NOTE: Adjustments made during cooking will not be saved to the program.
A. VIEWING STAGE NUMBER AND STAGE TIME REMAINING.
To view the Program and Stage numbers on the Upper Display, e.g. 3.1 = Program 3, Stage 1, and the Total Time Remaining in Stage
remaining on the Lower Display:
- Press Pkey during Program Cooking.
OR
- Turn Timer knob in either direction.
Upper Display will show Program and Stage, e.g.
Lower Display will show either,
- Total Time Remaining in Stage.
OR
- Total Elapsed Time of Stage (if Stage is set to InF’).
OR
- Core Probe Set Temp (if Stage is set to CP’).
OR
- Alternate between CPand Core Probe Set Temp (if presently in a Core Probe Stage).
Display will revert back to Overall Display after 5 seconds.
B. USING TEMPKNOB DURING PROGRAM COOKING.
VIEWING SET TEMPERATURE
Turn Tempknob (in either direction) to display Set Temperature of Current
Stage on Upper Display. Display will revert back to Overall Display after a
5-second delay.
ADJUSTING SET TEMPERATURE
Hold Tempknob in either direction for 3 seconds will enter Temp Edit Mode
where Tempknob can be used to temporarily adjust temperature for the current
stage. Controller will update the Temperature and exit Temp Edit Modeafter a
5-second delay.
C. USING TIMERKNOB DURING PROGRAM COOKING.
VIEWING STAGE NUMBER AND REMAINING TIME
Turn Timerknob (in either direction) to switch the display from Overall
(Program, Total Time remaining) to Current Stage-in-Progress (Stage, Stage
Time Remaining). Display will revert to Overall display after a 5-second delay.
ADJUSTING REMAINING TIME / ADJUSTING CORE PROBE SET TEMP
Hold the Timerknob in either direction for 3 seconds to enter Timer Edit Mode
where Timerknob can be used for temporary adjustment of either:
- Core Probe Set Temperature.
OR
- Stage Time remaining.
The controller will update the value and exit Timer Edit Modeafter a 5-second delay.
Time remaining can be adjusted between 0-180 minutes, but cannot be set to InFor
CP’.
Core Probe Set Temp can be set between 50-90°C (122-194°F).
NOTE: Any changes will only apply to the current stage. Any following stages will
revert to the programmed settings.
Here the Oven Set Temperature has been
increased from 150 to 175°C (325 to 350°F).
Here Core Probe Temperature has been
increased from 54 to 75°C (129 - 167°F).
Operation
12
D. CHANGING THE MOISTURE SETTING.
Press and hold Steamkey for 3 seconds.
Rotate Tempknob to select desired moisture level (H-0 to H-5).
Press Steamkey to confirm settings.
NOTE: Refer to Moisture Mode Settingsat start of this section for additional explanation of moisture level adjustments.
E. CHANGING FAN SPEED.
The pre-set fan speed can be changed by pressing Fan Lokey. Fan Loindicator will illuminate when fan low speed is
selected.
F. VIEWING ACTUAL OVEN TEMPERATURE / ACTUAL CORE PROBE TEMPERATURE.
Press Tempkey during cooking. Oven Set Temperature will display on Upper Display for 2 seconds, then Actual Temperature
will display on Upper Display for 2 seconds. At the same time, Actual Core Probe temperature will display on Lower Display
for 4 seconds. After 4 seconds, controller will revert to displaying the program number.
G. ADDING MORE TIME TO A STAGE WHEN THE END OF STAGE ALARM IS SOUNDING.
At the end of a stage, provided that ALr’=On, an end of stage alarm will sound for 1 minute before automatically progressing on to the
next stage of the program. While alarm is sounding, additional cooking time can be added to the stage that has just finished.
Rotate and hold Timerknob for 3 seconds to enter Timer Edit Mode and add time to the stage.
When the length of time required has been added, either;
- Press Timer-Start/Stopkey to resume the stage,
OR
- Wait for the auto-resume feature to progress the oven on to the next stage, 1 minute after alarm initially sounded.
When the additional time has run out, the end of stage alarm will sound for a second time. Either press Timer-Start/Stopkey
to progress on to the next stage, or let the program automatically progress on to the next stage after 1 minute of inactivity.
H. TURNING THE LIGHTS ON/OFF’.
Whenever the oven is On’, the On/Off-Lightkey is used to turn the oven lights On/Off’. Press On-Off/Lightkey to switch
oven light On-Off’.
To extend bulb life, an auto time-out can be pre-set to switch oven lights Offafter a set length of time. The factory default
for time-out is Off’ (‘0’, ie lights remain Onuntil light key is pressed again). This time-out can be activated by setting the
Controller - Operator Settings’, L-0 from 1-60 minutes.
NOTE: Any changes will only apply to the current stage. Following stages will revert to the programmed settings.
Programming
13
The oven can be pre-programmed with up to 20 Programs; each program can contain a maximum of 3 stages. When you receive your oven,
the controller is not pre-programmed. To set programs, carry out the following for each program required:
1. SELECT PROGRAMS MODE.
Press Programkey to enter Programs Mode.
ProgramLED will illuminate.
2. SELECT PROGRAM REQUIRED (P01 - P20).
Rotate Tempknob to the program required.
Upper Display will show program selected.
3. ENTER PROGRAMMING MODE.
Press and hold Programkey until a beep is heard, indicating entry into
Programming Mode. Upper Display shows program and stage numbers
eg
.
= Program 3, Stage 1.
ProgramLED will flash whilst in Programming Mode.
4. SELECT STAGE TO PROGRAM.
NOTE: If Multi-Stage Cooking is disabled, (Parameter StG - refer to section
Controller Operator Settings’) skip to Step 6 to continue
programming otherwise continue as below and overleaf.
All active stages and the first inactive stage are visible and can be accessed by
rotating the Tempknob to scroll through the stages. When editing a program for
the first time, only the first stage will be visible and it will be Offby default.
Setting parameters for a stage changes its state from Offto On(activates the
stage).
To Turn a Stage On’.
Either - Rotate Timerknob clockwise to
select On’.
Or - Press Pkey and program stage settings.
(Setting parameters for a stage automatically
changes its state to On’).
To Turn a Stage Off’.
Rotate Timerknob anti-clockwise to select Off’.
NOTE: Only the last active (‘On’) stage can
be turned Off’.
Rotate Tempknob:-
‘+’ to advance one stage.
-to go to the previous stage.
ProgramLED is On
when Oven is
operating in
Programs Mode.
In Program Mode,
Temp Knobis
used to select:-
Program.
Stage.
And to set:-
Cook Temperature.
Moisture Level.
Fan Speed Option.
In Program Mode,
TimerKnob is
used to select:-
Core Probe.
And to set:-
Program Time.
Core Probe
Temperature.
Program 3, Stage 1.
STATE: ON.
Program 3, Stage 2.
STATE: ON.
Program 3, Stage 3.
STATE: OFF (ie; Inactive).
Programming
14
5. CONFIRM STAGE TO EDIT.
Press Programkey to begin editing a program and stage displayed on the Upper Display.
6. SET OVEN TEMPERATURE.
*Upper Display flashing*
Rotate Tempknob to select temperature required.
+ to increase the temperature (Max. 260°C / 500°F).
- to decrease the temperature (Min. 60°C / 140°F).
Press Pkey to confirm temperature setting. Controller will step to Cook Time / Core Temp Probe setting.
7. SET COOK TIME / CORE TEMP PROBE.
*Lower Display flashing*
The Timerknob can be used to select Core Temp Probe or a Cook Time option.
By setting a Cook Time, the stage w ill be governed by Oven Tem perature, Timer, Moisture setting and Fan Speed.
Rotate Timerknob to select time required.
+ to increase Cook Time (Max. 180 minutes).
- to decrease Cook Time (Min. 1 minute).
Press Pkey to confirm Timer setting and advance to setting Moisture setting.
By setting Core Temp Probe (CP), the stage will run at a set Oven Temperature, Moisture Mode and Fan Speed until the actual
core temperature reaches the pre-set core probe temperature value. Refer to the Cooking in Manual Mode with Core Probe
Section for instructions on cooking with the Core Probe fitted. Turn and hold timer knob until lower display shows CP’.
Controller will step to setting Core Probe Temperature. Core Probe Temperature value is displayed on Lower Display.
Rotate Timerknob to select temperature required.
‘+’ to increase Core Probe Temperature (Max 90°C / 194°F).
-to decrease Core Probe Temperature. (Min 50°C / 122°F).
Press Pkey to confirm Core Probe Temp Setting. Controller will step to Moisture setting.
By setting Infinite Time setting (‘InF’), Oven counts time upwards up to a limit of 999 minutes. The Infinite (‘InF’) timer
option is only available as an option when setting the last stage of a program. If the InFtimer option is programmed, no stages
after the InFstage will be available / visible. Turn Offall stages that come after a given stage in order to set an InFtimer for
that stage.
Press Pkey to confirm infinite time InFsetting and advance to setting Moisture setting.
= Stage has been set toOFF.
= Infinity Time Setting.
= Core Temp Probe (optional extra).
Time = From 1 minute to 180 minutes.
Turn and Release Timer Knob to change
selection.
Hold Knob to Fast Forward Fast Reverse.
1 Min 180 Mins
Programming
15
8. SET MOISTURE OPTION (H-0 - H-5).
*Upper Display flashing*
Rotate Tempknob to select Moisture setting required.
‘+’ to increase moisture setting.
-to decrease moisture setting.
(Refer to Operation section, Moisture Mode Settings’, for additional explanation of moisture level adjustment).
Press Pkey to confirm Moisture setting. Controller will step to Fan Speed setting.
9. SET FAN SPEED (LO - HI).
Upper Display shows
*Lower Display Flashing with current Fan setting*
Rotate Timerknob to select desired fan option, shown on Lower Display.
Press Pkey to confirm fan speed setting. Controller will step to Alarm setting for End of Stage.
NOTE: If Multi-Stage Cooking is disabled, (Operator setting StG- set to no’), the controller will exit the Programming
Mode after the Pkey is pressed to confirm fan speed setting.
10.SET ALARM FOR END OF STAGE (‘ON-OFF’).
Upper Display shows
*Lower Display flashing with current alarm setting*
Rotate Timerknob to select desired alarm state which will be shown on the Lower Display.
ON- Alarm sounds at completion of the cooking stage, the program is paused awaiting user action. Without any input, the program
will automatically resume after 1 minute.
- Press Timer-Start/Stopkey to stop the alarm, resume cooking and to continue to the next cooking stage.
OR
- Open oven door to stop alarm. Close door and press Timer-Start/Stopkey to continue cooking and to continue on to the
next cooking stage.
OFF- Oven continues on to the next cooking stage without sounding an alarm.
NOTE: Regardless of the setting applied to the last stage of the program, a Cook Time Completed Alarm will sound to indicate the
end of the program.
Press Pkey to confirm alarm option. Alarm will sound to confirm that all stage parameters have been set.
Repeat Step 1 to Step 10 to program additional stages.
11.EXIT PROGRAMMING MODE.
Press and hold Pkey for 3 seconds until alarm sounds to exit the Programming Mode.
USB Export / Import
16
The Oven controller is equipped with USB connectivity, through the USB port located on the lower right hand side of the control panel.
The set of programs, P01 - P30, stored in the controller memory can be:
Written to a USB memory stick (Export).
Replaced with a set of programs located on the USB stick (Import).
1. To export the set of programs from the controller to the USB stick:
Ensure the oven is in Standby ModeOn / Off LED is lit.
Insert a USB memory stick into the USB port.
Upper display will show USBand lower display will show EPr(Export Programs).
Press Start / Stopbutton.
Lower display will alternate between rEvand ‘001’ (Revision Number e.g. 000 to 999).
(The set of programs can be given a different/new revision number at this point)
Rotate TimerKnob to select revision number required.
Press Start / Stopbutton to copy programs from controller to USB stick.
If an error message (Err, Er1 or Er2) appears in lower display, refer to
section Fault Finding
Lower display will show rUn, followed by dnEonce copying is done.
Remove USB memory stick from USB port.
Controller will go back to Standby Mode.
The export feature is useful for backing up the set of programs created in the controller,
creating a copy of the set of programs to apply to another oven, and for editing programs
externally.
2. To import the set of programs to the controller from the USB stick:
Ensure the oven is in Standby Mode-On / OffLED is lit.
Insert a USB memory stick, containing at least one MPRGRXXX.csvfile into the USB port
(See Section Import / Export Files).
Upper display will show USBand lower display will show EPr(Export Programs).
Rotate Timerknob to change to IPron lower display (Import Programs).
NOTE: IPr will not show on display if a MPRGRXXX.csvfile is not present.
Press Start / Stopbutton to copy programs from USB stick to controller.
If more than one file is present, i.e. MPRGR001, MPRGR002…, the option to select between
these will appear:
Lower display will alternate between rEvand ‘001’ (Revision Number e.g. 000 to 999).
Rotate TimerKnob to select revision number required.
(A maximum of 10 revisions on the USB Stick will be selectable).
Lower display will show rUn, followed by dnEonce copying is done.
Remove USB memory stick from USB port
Controller will go back to Standby Mode.
The import feature is useful for restoring a backed up set of programs, copying programs from another oven, and for loading
programs edited externally.
ON / OFFLED is On
when oven is in
Stand-ByMode.
Timer-Start / StopLED
is Onwhen oven is in
Stand-ByMode.
USB Export / Import
17
With the USB connectivity, it is also possible to export / import the parameters that determine the functions of the oven.
The export function described under USB EXPORT / IMPORT PROGRAMS, also exports the parameter file PARAM.csv, so the
process is almost identical:
1. To export the Parameters from the controller to the USB stick:
Ensure the oven is in Standby Mode-On / Off LED is lit.
Insert a USB memory stick into the USB port.
Upper display will show USBand lower display will show EPr (Export Programs).
Press Start / Stopbutton to copy programs from controller to USB stick.
Lower display will show rUn, followed by dnEonce copying is done.
Remove USB memory stick from USB port.
Controller will go back to Standby Mode.
The export feature is useful for backing up the parameters in the controller, or creating
a copy of the set of parameters to apply to another oven.
2. To import the set of parameters from the USB stick to the controller:
Ensure the oven is in Standby Mode-On/OffLED is lit.
Insert a USB memory stick, containing a PARAM.csvfile, into the USB port
(see Section Import / Export - Files’).
Upper display will show USBand lower display will show EPr(Export Programs).
Rotate Timerknob to change to IPron lower display (Import Programs).
Press Start/Stopbutton to copy parameters from USB stick to controller.
Lower display will show rUn, followed by dnEonce copying is done.
Remove USB memory stick from USB port.
Controller will go back to Standby Mode’.
The import feature is useful for restoring a backed up set of parameters, or applying a copy of parameters from another
oven.
ON/OFFLED is On
when oven is in Stand-
ByMode
Timer-Start / StopLED
is Onwhen oven is in
Stand-ByMode
USB Export / Import
18
The Set of Programs, P01-P30, in the controller, has a revision number attached to it, for the purpose of keeping track of changes and
updates to the set of programs stored in the controller or externally on USB Stick / PC.
1. To view the current Program Set Revision Number:
Enter into User Settings, as described under Controller - User Settings.
Quick Guide:-
Place the oven into Standby Mode-On / Off LED is lit.
Press and hold Steamand Start / Stopbuttons together until PASis
showing in upper display.
Rotate Timerknob until ‘123’ shows on lower display.
Press FAN LObutton.
Rotate Timerknob until parameter PrGshows in upper display.
Lower display will alternate between showing rEu, (for revision), and the revision
number, i.e. ‘001’.
The revision number can be edited, if required, in the same manner as other User Settings’.
(Refer to Controller - User Settings on the following pages)
Refer section USB Export / Import - Programsfor further information on using Programs Revision Numbering’.
ON/OFFLED is On
when oven is in Stand-
ByMode
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29

Moffat E33D5 Operating instructions

Category
Microwaves
Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI