INSTALLATION MANUAL
G2088
MANUAL BARRIER
FA00022-EN
E
ng
li
s
h
E
N
p.
2
2 - Manual code:
FA00022-EN
FA00022-EN v.
1
1- 07/2015 - © Came S.p.A. - The manual's contents may be edited at any time without notice.
LEGEND
This symbol shows which parts to read carefully.
This symbol shows which parts describe safety issues
This symbol shows which parts to tell users about.
DESCRIPTION
Manual barrier made of varnished galvanized steel.
Any installation and/or use other than that specified in this manual is forbidden.
Limits to use
Type G2088
Maximum width of passage width (m) 7.60
Danger of hand crushing
No transiting while the barrier is moving
WARNING!
important safety instructions for people:
READ CAREFULLY!
Technical data
Type G2088
Weight (Kg) 51.5
PREMISE
• THIS PRODUCT SHOULD ONLY BE USED FOR THE PURPOSE FOR WHICH IT
WAS EXPLICITLY DESIGNED. ANY OTHER USE IS DANGEROUS. CAME S.P.A.
IS NOT LIABLE FOR ANY DAMAGE CAUSED BY IMPROPER, WRONGFUL AND UN-
REASONABLE USE. • THE SAFETY OF THIS PRODUCT AND ITS PROPER FITTING
DEPENDS, THEREFORE, ON RESPECTING ITS TECHNICAL CHARACTERISTICS AND
PROPER FITTING, TO BE DONE IN STATE-OF-THE-ART FASHION, AND UNDER SAFE
CONDITIONS AS EXPRESSLY EXPLAINED IN THE LITERATURE THAT COMES WITH
THE PRODUCT. • STORE THESE WARNINGS WITH THE BARRIER'S INSTALLATION
MANUAL.
BEFORE INSTALLING
(CHECKING WHAT'S THERE: IF SOMETHING IS MISSING, DO NOT CONTINUE UNTIL
YOU HAVE COMPLIED WITH ALL SAFETY PROVISIONS)
• FITTING AND TESTING MUST BE BE ONLY PERFORMED BY QUALIFIED TECHNI-
CIANSCOMMISSIONING AND TESTING MUST BE CAREFULLY DONE IN STATE OF
THE ART FASHION AND IN COMPLIANCE WITH CURRENT LAWS • BEFORE BEGIN-
NING ANY OPERATION IT IS MANDATORY TO CAREFULLY READ ALL INSTRUCTIONS;
IMPROPER INSTALLATION MAY RESULT IN SERIOUS HARM TO PEOPLE AND THINGS.
• MAKE SURE THE BOOM IS IN A PROPER MECHANICAL STATE, BALANCED
AND ALIGNED, AND THAT IT OPENS AND CLOSES PROPERLY. ALSO INSTALL, IF
NECESSARY, SUITABLE PROTECTIONS • DO NOT FIT THE BARRIER UPSIDE DOWN
OR ONTO ELEMENTS THAT COULD BEND. IF NECESSARY, ADD SUITABLE REINFOR-
CEMENTS TO THE ANCHORING POINTS • DO NOT INSTALL ON SLOPES, THAT IS,
ON ANY SURFACES THAT ARE NOT PERFECTLY LEVEL.
INSTALLING
• SUITABLY SECTION OFF AND DEMARCATE THE ENTIRE INSTALLATION SITE TO
PREVENT UNAUTHORIZED PERSONS FROM ENTERING THE AREA, ESPECIALLY MI-
NORS AND CHILDRENBE CAREFUL WHEN HANDLING OPERATORS THAT WEIGH
OVER 20 KG. IF NEED BE, USE PROPER SAFETY-HOISTING EQUIPMENTLA-
BEL ANY CRUSHING, CONVEYING OR SHEARING POINTSTHE MANUFACTURER
DECLINES ANY LIABILITY FOR USING NON-ORIGINAL PRODUCTS; WHICH WOULD
RESULT IN WARRANTY LOSSAPPLY CLEARLY VISIBLE WARNING SIGNS WHERE
NECESSARY.
SPECIAL USER-INSTRUCTIONS AND RECOMMENDATIONS
KEEP BARRIER OPERATION AREAS CLEAN AND FREE OF ANY OBSTRUCTIONS. •
DO NOT ALLOW KIDS TO PLAY OR LOITER IN THE BARRIER'S MANEUVERING AREA.
CLEANING AND MAINTENANCE BY USERS MUST NOT BE DONE BY CHILDREN,
UNLESS PROPERLY SUPERVISEDFREQUENTLY CHECK THE SYSTEM FOR ANY
MALFUNCTIONING OR DAMAGED MOVING PARTS, AND FOR THE SOUNDNESS OF
ALL ANCHORING POINTS AND DEVICES. KEEP ANY HINGES, MOVING JOINTS AND
THE BOOM FLANGE CLEAN, FRICTION FREE AND PROPERLY LUBRICATED. • IS FOR
BIDDEN FOR USERS TO PERFORM ANY JOBS THAT ARE NOT EXPRESSLY STATED.
FOR ANY REPAIRS, SETTING MODIFICATIONS AND EXTRAORDINARY MAINTENANCE,
CALL TECHNICAL ASSISTANCE. .
FURTHER RECOMMENDATIONS FOR ALL
KEEP CLEAR OF THE BARRIER
AND ANY OF ITS MECHANICAL MOVING PARTSDO NOT ENTER
THE MOVING BARRIER'S REACHALWAYS PAY SPECIAL ATTENTION TO ANY
DANGEROUS POINTS, WHICH HAVE TO BE LABELED WITH SPECIFIC PICTOGRAMS
AND/OR BLACK AND YELLOW STRIPESIF THE SPRING BREAKS, THE BARRIER
COULD MOVE WITHOUT WARNING.
243 493
405
1305
7600
914
3
28
4
5
6
1
9
7
10
11
p.
3
3 - Manual code:
FA00022-EN
FA00022-EN v.
1
1- 07/2015 - © Came S.p.A. - The manual's contents may be edited at any time without notice.
Dimensions (mm) max
Description of parts
1. Dome
2. Plate
3. Mid plate
4. Boom-attachment cover
5. Protective casing shear proof
6. Cabinet
7. Lever arm
8. Boom adjustment buffer
9. Inspection hatch
10. Anchoring plate
11. Anchoring bracket
GENERAL INSTRUCTIONS FOR INSTALLING
Only skilled, qualified staff must install this product.
Preliminary checks
Before beginning, do the following:
• check the solidity of the plate-fastening point.
Tools and materials
Make sure you have all the tools and materials you will need for installing in total safety and in compliance with applicable regulations. The figure
shows some of the equipment installers will need.
690
360
450
240
460
p.
4
4 - Manual code:
FA00022-EN
FA00022-EN v.
1
1- 07/2015 - © Came S.p.A. - The manual's contents may be edited at any time without notice.
INSTALLATION
The following illustrations are mere examples. The space needed for fastening the barrier varies depending on where it is installed.
It is up to the installer to find the most suitable solution.
Warning! Use hoisting equipment to transport and position the barrier.
During the set up and installing stages the barrier could be unstable and tip over.
So, be careful and do not lean on it until it is fully fastened.
Preparing the fastening plate.
If the flooring does not allow for a sturdy fastening of the entry unit, you will have to set up a cement slab.
Dig a hole for the foundation frame.
Set up a foundation frame that is larger than the anchoring plate and sink it into the dug hole.
Fit an iron cage into the foundation frame to reinforce the concrete.
Assemble the four anchoring brackets to the anchoring plate.
Place the plate over the iron cage. Fill the foundation frame with concrete. The base must be perfectly level with the bolts which are entirely above
surface.
Wait at least 24 hrs for the concrete to solidify.
Remove the foundation frame.
Fill the hole with earth around the concrete block.
Remove the nut and washer from the bolts.
p.
5
5 - Manual code:
FA00022-EN
FA00022-EN v.
1
1- 07/2015 - © Came S.p.A. - The manual's contents may be edited at any time without notice.
Preparing the barrier
Fit the key into the lock and turn it counter-clockwise, lift the dome and remove the inspection hatch.
The barrier is set up for installing on the left.
When installing on the right, invert the boom's opening direction, as follows:
- remove the spring-attaching bracket from the lever arm ;
- turn the lever arm by 90°;
- fasten the spring-attachment bracket opposite the lever arm.
UNI5931 M8x20
UNI5931 M8x20
UNI5931 M8x12
p.
6
6 - Manual code:
FA00022-EN
FA00022-EN v.
1
1- 07/2015 - © Came S.p.A. - The manual's contents may be edited at any time without notice.
Assemble the barrier attachment-cover, the mid plate and the plate by using a screw . Leave the screw loosened to better fit the boom
later on.
Fit the boom into the attachment-cover and fasten it using the screws .
Installing the barrier
The cabinet should be installed with the inspection hatch on the most accessible side to make any adjusting easier.
Place the cabinet onto the anchoring plate and fasten it using nuts and washers.
=
=
UNI6954 Ø 2,9x13
UNI6954 Ø 3,9x19
p.
7
7 - Manual code:
FA00022-EN
FA00022-EN v.
1
1- 07/2015 - © Came S.p.A. - The manual's contents may be edited at any time without notice.
Cut the groove covering profiles to measure and fit them into either side.
Use the screws to fasten the boom endcap.
Boom endcap
Fit the anti-shearing protective cover onto the boom-attachment cover and fasten it with screws.
p.
8
8 - Manual code:
FA00022-EN
FA00022-EN v.
1
1- 07/2015 - © Came S.p.A. - The manual's contents may be edited at any time without notice.
400 mmPASSAGE WIDTH (max. 7.60 m)
Balancing the boom
Before proceeding, check that the spring you have chosen is suitable for the accessories and the clearance.
001G02802 It cannot be used for barriers with booms fitted with the 001G0465 skirt or 001G02808 swing-rest.
001G02808 For passage widths of up to 7 m max.
001G02807 It MUST be used for passage widths greater than 7 m.
001G0465 - 001G02808 They cannot be used together.
A 001G02040 spring
Ø 40 mm
B 001G04060 spring
Ø 50 mm
C 001G06080 spring
Ø 55 mm
BOOM DIMENSIONS (m)
2 ÷
2.5 2.5 ÷ 3 3 ÷ 3.5 3.5 ÷ 4 4 ÷ 4.5 4.5 ÷ 5 5 ÷ 5.5 5.5 ÷ 6 6 ÷ 6.5 6.5 ÷ 7 7 ÷ 7.6
Boom
A A A A A B A B A B B B B B B C C C
Boom with swing-leg 001G02808
A A A A A A A B A B B B B B B C C C
Boom with skirt 001G0465
A A A A B A B B B B B B C B C C C
The boom includes the transparent groove cover and end cap.


 
UNI5739
M12x70
p.
9
9 - Manual code:
FA00022-EN
FA00022-EN v.
1
1- 07/2015 - © Came S.p.A. - The manual's contents may be edited at any time without notice.
Manually turn the spring to increase or reduce the traction. The boom should stabilize at 45°. Fasten the counter-nut.
Check the proper working state of the spring.
With the boom raised vertically the spring is not taut.
With the boom lowered horizontally the spring is taut.
Position the boom vertically.
Install the spring into the barrier in the following way:
- fit a UNI5739 M12x70 screw into the attachment bracket and tighten the UNI5588 M12 nut to the screw .
- tighten the screw into the spring ;
- tighten the eyelet rod under the spring .
Hook the tie rod to the anchoring bracket.
Perform the same procedure for a possible second spring.
+-
~1°
~89°
~1°
~89°
+
-
p.
10
10 - Manual code:
FA00022-EN
FA00022-EN v.
1
1- 07/2015 - © Came S.p.A. - The manual's contents may be edited at any time without notice.
To correct the horizontal position:
- raise the boom;
- turn the mechanical closing stop clockwise to increase the boom travel or counter clockwise to reduce it .
Fasten the stop with a counter nut .
Establishing the limit-switch points
Close the inspection hatch and check that the boom is parallel to the road surface and closed and at about 89° when open.
The boom's opening and closing maneuvers must be performed with the inspection hatch closed.
To correct the boom's vertical position:
- lower the boom;
- open the inspection hatch;
- turn the opening mechanical stop clockwise to increase the boom's travel or counter clockwise to reduce it .
Fasten the stop with a counter nut .
p.
11
11 - Manual code:
FA00022-EN
FA00022-EN v.
1
1- 07/2015 - © Came S.p.A. - The manual's contents may be edited at any time without notice.
FINAL OPERATIONS
Replace the inspection hatch and the upper dome. Lock the hatch using the key.
DISMANTLING AND DISPOSAL
CAME S.p.A. applies a certified Environmental Management System at its premises, which is compliant with the UNI EN ISO 14001
regulations to ensure the environment is safeguarded.
Please continue safeguarding the environment. At CAME we consider it one of the fundamentals of our operating and market strategies. Simply
follow these brief disposal guidelines:
DISPOSING OF THE PACKAGING
The packaging materials (cardboard, plastic, and so on) should be disposed of as solid urban waste, and simply separated from other waste for
recycling.
Always make sure you comply with local laws before dismantling and disposing of the product.
DO NOT DISPOSE OF IN NATURE!
DISMANTLING AND DISPOSAL
Our products are made of various materials. Most of these (aluminum, plastic, iron) can be disposed as household waste. They can be recycled
by separating them before dumping at authorized city plants.
Before disposing, it is always advisable to check with the specific laws that apply in your area.
DO NOT DISPOSE OF IN NATURE!
www. came.com
www. came.com
Came S.p.A.
Came S.p.A.
Via Martiri Della Libertà, 15 Via Cornia, 1/b - 1/c
31030
Dosson di Casier
Dosson di Casier
Treviso
Treviso - Italy
33079
Sesto al Reghena
Sesto al Reghena
Pordenone
Pordenone - Italy
(+39) 0422 4940
(+39) 0422 4941
(+39) 0434 698111
(+39) 0434 698434
English
English - Manual code:
FA00022-EN
FA00022-EN v.
1
1 - 07/2015 - © Came S.p.A.
The contents of this manual may be changed at any time without prior notice.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

CAME GARD 8 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI