K nner S hnen KS6100HDE Heavy Duty Diesel Generator User manual

Type
User manual
2
COMMISSIONING
PROCEDURE FOR
DIESEL GENERATOR
345678910 11 12
Please read the operating manual
carefully before getting started!
1
1
COMMISSIONING
PROCEDURE FOR
DIESEL GENERATOR
345678910 11 12
Before the first start, fill the
crankcase with engine oil.
To do this, proceed as follows:
1. Unscrew the oil dipstick.
2. Use a funnel to fill the crankcase with engine oil (SAE 10W-30,
SAE 10W-40).
3. The oil level should be equal to the level in the filler neck.
2
COMMISSIONING
PROCEDURE FOR
DIESEL GENERATOR
45678910 11 12
1
Check the oil level in the crankcase.
To do this, proceed as follows:
1. Insert the dipstick without screwing it in.
2. Check the oil level by a mark on the oil dipstick. It must be between the
MIN and MAX marks.
3. Add fresh oil if its level is below the lower mark.
4. Tighten the oil dipstick.
23
12
COMMISSIONING
PROCEDURE FOR
DIESEL GENERATOR
35678910 11 12
Fill the fuel tank with diesel fuel.
Check the fuel level on the fuel level sensor.
Tighten the fuel cap securely.
The type of diesel fuel must comply with the operating season
4
12
COMMISSIONING
PROCEDURE FOR
DIESEL GENERATOR
34678910 11 12
Connect the terminals to the battery ensuring the
correct polarity
("plus" to "plus", "minus" to "minus").
5
12
COMMISSIONING
PROCEDURE FOR
DIESEL GENERATOR
34578910 11 12
Set the emergency engine
switch to START (ON).
6
12
COMMISSIONING
PROCEDURE FOR
DIESEL GENERATOR
34568910 11 12
During the first start-up, be sure to bleed
air from the fuel system.
To do this, proceed as follows:
1. Remove the protective rubber plug on the top of
the generator.
7
12
COMMISSIONING
PROCEDURE FOR
DIESEL GENERATOR
34567910 11 12
2.Hold down the compression release lever.
8
12
COMMISSIONING
PROCEDURE FOR
DIESEL GENERATOR
34567810 11 12
3. Turn the start key to the "START" position and hold it in
this position for several seconds.
4. After 2-3 seconds, release the compression release lever
without releasing the start key.
5. After the engine starts, release the start key for it to
return to the "ON" position.
9
12
COMMISSIONING
PROCEDURE FOR
DIESEL GENERATOR
345678911 12
Germany: DIMAX Int. GmbH,
An Sankt Germanus 13, 50389,
Wesseling
If the engine does not start, repeat steps 1-5 in two to
three minutes (see pages 7-9).
If the engine does not start after three successive
attempts, contact our after-sales and service support.
10
12
COMMISSIONING
PROCEDURE FOR
DIESEL GENERATOR
345678911 12
After starting the generator, wait 1-2 minutes before
connecting the load.
Then turn the safety switch on the generator panel to
the "ON" position.
10 11
12
COMMISSIONING
PROCEDURE FOR
DIESEL GENERATOR
345678910 12
To start the generator in winter, turn the start
key to the "START" position by holding the
"HEAT" heating button on the generator panel.
11 12
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

K nner S hnen KS6100HDE Heavy Duty Diesel Generator User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI