44
Installation
Placement
When choosing an installation place, consider
following points:
• Observe all safety warnings!
• Ensure the minimum surrounding distance
in every direction of 30 cm and 100 cm to
other electrical products.
• Keep a surrounding distance of minimum
50cm around the outside of the exhaust
wall outlet and protect it from entering
objects and moisture.
• Make sure the wall behind the product is
an exterior wall not a divider and the drill
holes can be made in a safe way, and are not
obstructed by hidden objects in the wall.
• Ensure that a suitable power outlet is within
reach at the desired location and remains
accessible after installation.
• Consider that during dehumidifying
operation water is collected inside the
product, which must be continuously drained
through a connected drainage hose into a
suitable container or a nearby drain.
• Ensure there are no obstacles obstructing
the airflow.
Note:
If the product has been transported in a
horizontal position, it must not be plugged
in for 24 hours, in order to avoid damages of
the cooling system.
Air exhaust
The exhaust hose and adaptor must be
installed or removed in accordance with the
usage mode:
• COOL, AUTO mode: install exhaust hose
• FAN, DEHUMIDFY mode: remove exhaust
hose
Wall mounting (Part: N, O, P)
Fig.
1
Screw the wall adapter and exhaust
adapter onto each side of the exhaust
hose. Connect the exhaust adapter to
the air exhaust of the product.
Fig.
2
Use the wall duct as pattern to mark the
hole spacing on the wall. Drill the holes
with a suitable power tool. Free the
holes from dust and mount the wall
duct using supplied screws and plugs.
Connect the wall connector to the wall
adaptor.
Note:
• The exhaust hose can be expanded and
compressed, but for optimal performance,
keep the exhaust length to a minimum.
• Do not extend the exhaust hose.
• Avoid over-bending.
• Observe the decommissioning instructions
in the respective section, if the product is
not to be used for a longer period of time.
• Material necessary for attachment and
sealing is not provided but must be
purchased in special shops
Drainage hose
The drainage hose is used to drain water from
the upper drain outlet.
Fig.
3
Remove the rubber plug from the upper
drainage outlet and slide the drainage
hose as far as possible onto the outlet.
Lead the other end of the drainage hose
into a suitable container or a nearby drain.
Note:
• Depending on the set modus the water
is either drained directly or collected in an
internal tank. Drain the water respectively.
• Attach the open end of the drainage hose
to the drainage hose holder, when not in
use.
• Always cover the drain outlets when not
in use.
• Observe the decommissioning
instructions in the respective section, if
the product is not to be used for a longer
period of time.
IM_KAC3232_KAC3352_181220_V04_HR.indb 44 20/12/18 4:15 pm